CISCO-ENTITY-PFE-MIB: View SNMP OID List / Download MIB

VENDOR: CISCO


 Home MIB: CISCO-ENTITY-PFE-MIB
Download as:   

Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
 ciscoEntityPfeMib 1.3.6.1.4.1.9.9.265
The Packet Forwarding Engine technology are Cisco developed Network Processors, which accelerates certain features in order to provide better network performance. An agent uses this MIB to monitor the performance history on any active PFE pipeline listed in the ENTITY-MIB (RFC 2737) entPhysicalTable. This monitoring is via measurement periods of actual, 1-minute, 5-minutes and 15-minutes. For the 1-minute and 5-minute measurement periods, perfor- mance statistics are calculated and displayed based on pre- vious 1 minute and 5 minute respectively. For the 15-minute period, the performance statistics are accumulated in fifteen minute intervals. At any one time, an agent maintains one current (incomplete) interval and up to 96 completed intervals (24 hours worth). Fewer than 96 intervals of data will be available if the agent has been restarted within the last 24 hours. In addition, there is a rolling 24-hour total of each performance statistic. There is no requirement for an agent to ensure fixed rela- tionship between the start of a fifteen minute interval and any wall clock; however some agents may align the fifteen minute intervals with quarter hours.
         cePfeMIBNotifications 1.3.6.1.4.1.9.9.265.0
             cePfeHistThldEvent 1.3.6.1.4.1.9.9.265.0.1
This notification is generated when a threshold event has occurred and the cePfeHistNotifiesEnable is set to 'notify (3)' or 'logAndNotify(4)'. After generating this notification, another such notifica- tion will not be sent out until the sample value has fallen below the threshold value.
             cePfeHistRestartEvent 1.3.6.1.4.1.9.9.265.0.2
This notification is generated when a restart event has occurred and the cePfeHistNotifiesEnable is set to 'notifyp (3)' or 'logAndNotify(4)'.
         cePfeMIBObjects 1.3.6.1.4.1.9.9.265.1
             cePfePerformance 1.3.6.1.4.1.9.9.265.1.1
                 cePfePerfConfigTable 1.3.6.1.4.1.9.9.265.1.1.1 no-access
This table contains configuration information on a PFE pipeline.
                     cePfePerfConfigEntry 1.3.6.1.4.1.9.9.265.1.1.1.1 no-access
An entry will exist for each entry in the entPhysicalTable that correspond to an active PFE pipeline.
                         cePfePerfConfigTimeElapsed 1.3.6.1.4.1.9.9.265.1.1.1.1.1 unsigned32 read-only
The number of seconds that have elapsed since the beginning of the current 15 min interval. If for some reason, such as an adjustment in the system's time-of-day clock, the current interval exceeds the maximum value, the agent will return the maximum value.
                         cePfePerfConfigValidIntervals 1.3.6.1.4.1.9.9.265.1.1.1.1.2 unsigned32 read-only
The number of completed 15 min intervals for which valid PFE performance data has been collected. The value will be 96 unless the interface was brought online within the last 24 hours, in which case the value will be the number of completed 15 minute intervals since the PFE pipeline has been online.
                         cePfePerfConfigThldUtilization 1.3.6.1.4.1.9.9.265.1.1.1.1.3 percentage read-write
This object contains the threshold value for the cePfePerfCurrentUtilization object. If during the last 5 second measurement period the cePfePerfCurrentUtilization object becomes greater than or equal to this threshold value, an event of type 'thldUtilizationEvent' will be genera- ted. Value of zero indicates that no comparison is being made between the cePfePerfCurrentUtilization object value and the threshold value, therefore no event action will be gene- rated.
                         cePfePerfConfigThldEfficiency 1.3.6.1.4.1.9.9.265.1.1.1.1.4 percentage read-write
This object contains the threshold value for the cePfePerfCurrentEffciency object. If during the last 5 second measurement period the cePfePerfCurrentEfficiency object becomes less than or equal to this threshold value, an event of type 'thldEfficiencyEvent' will be genera- ted. Value of zero indicates that no comparison is being made between the cePfePerfCurrentEfficiency object value and the threshold value, therefore no event action will be gene- rated.
                         cePfePerfConfigThld1MinUtilization 1.3.6.1.4.1.9.9.265.1.1.1.1.5 percentage read-write
This object contains the threshold value for the cePfePerfCurrent1MinUtilization object. If during the last 1 minute measurement period the cePfePerfCurrent1MinUtilization object becomes greater than or equal to this threshold value, an event of type 'thld1MinUtilizationEvent' will be genera- ted. Value of zero indicates that no comparison is being made between the cePfePerfCurrent1MinUtilization object value and the threshold value, therefore no event action will be gene- rated.
                         cePfePerfConfigThld1MinEfficiency 1.3.6.1.4.1.9.9.265.1.1.1.1.6 percentage read-write
This object contains the threshold value for the cePfePerfCurrent1MinEfficiency object. If during the last 1 minute measurement period the cePfePerfCurrent1MinEfficiency object becomes less than or equal to this threshold value, an event of type 'thld1MinEfficiencyEvent' will be genera- ted. Value of zero indicates that no comparison is being made between the cePfePerfCurrent1MinEfficiency object value and the threshold value, therefore no event action will be gene- rated.
                         cePfePerfConfigThld5MinUtilization 1.3.6.1.4.1.9.9.265.1.1.1.1.7 percentage read-write
This object contains the threshold value for the cePfePerfCurrent5MinUtilization object. If during the last 5 minute measurement period the cePfePerfCurrent5MinUtilization object becomes greater than or equal to this threshold value, an event of type 'thld5MinUtilizationEvent' will be genera- ted. Value of zero indicates that no comparison is being made between the cePfePerfCurrent5MinUtilization object value and the threshold value, therefore no event action will be gene- rated.
                         cePfePerfConfigThld5MinEfficiency 1.3.6.1.4.1.9.9.265.1.1.1.1.8 percentage read-write
This object contains the threshold value for the cePfePerfCurrent5MinEfficiency object. If during the last 5 minute measurement period the cePfePerfCurrent5MinEfficiency object becomes less than or equal to this threshold value, an event of type 'thld5MinEfficiencyEvent' will be genera- ted. Value of zero indicates that no comparison is being made between the cePfePerfCurrent5MinEfficiency object value and the threshold value, therefore no event action will be gene- rated.
                 cePfePerfCurrentTable 1.3.6.1.4.1.9.9.265.1.1.2 no-access
This table maintains PFE current running performance, which are collected at various measurement periods.
                     cePfePerfCurrentEntry 1.3.6.1.4.1.9.9.265.1.1.2.1 no-access
An entry containing performance information applicable to a particular PFE pipeline.
                         cePfePerfCurrentUtilization 1.3.6.1.4.1.9.9.265.1.1.2.1.1 currentutilization read-only
This object provides the actual PFE percentage utilization. It is determined by the number of new work contexts + feedback contexts divided by total number of contexts that can be supported by the PFE pipeline.
                         cePfePerfCurrentEfficiency 1.3.6.1.4.1.9.9.265.1.1.2.1.2 currentefficiency read-only
This object provides the actual PFE percentage efficiency. It is determined by the total number of contexts per second divided by maximum theoretical contexts per second supported by the PFE pipeline. Under normal conditions, this number will be 100 and when efficiency starts degrading, it will start going down until it reaches zero.
                         cePfePerfCurrent1MinUtilization 1.3.6.1.4.1.9.9.265.1.1.2.1.3 currentutilization read-only
This object provides the PFE percentage utilization over the previous 1 minute period. It is determined by the number of new work contexts + feedback contexts divided by total number of contexts that can be supported by the PFE pipeline.
                         cePfePerfCurrent1MinEfficiency 1.3.6.1.4.1.9.9.265.1.1.2.1.4 currentefficiency read-only
This object provides the PFE percentage efficiency over the previous 1 minute period. It is determined by the totalnumber of contexts per second divided by maximum theoretical contexts per second supported by the PFE pipeline. Under normal conditions, this number will be 100 and when efficiency starts degrading, it will start going down until it reaches zero.
                         cePfePerfCurrent5MinUtilization 1.3.6.1.4.1.9.9.265.1.1.2.1.5 currentutilization read-only
This object provides the PFE percentage utilization over the previous 5 minutes period. It is determined by the number of new work contexts + feedback contexts divided by total number of contexts that can be supported by the PFE pipeline.
                         cePfePerfCurrent5MinEfficiency 1.3.6.1.4.1.9.9.265.1.1.2.1.6 currentefficiency read-only
This object provides the PFE percentage efficiency over the previous 5 minutes period. It is determined by the total number of contexts per second divided by maximum theoretical contexts per second supported by the PFE pipeline. Under normal conditions, this number will be 100 and when efficiency starts degrading, it will start going down until it reaches zero.
                 cePfePerfIntervalTable 1.3.6.1.4.1.9.9.265.1.1.3 no-access
This table contains performance statistics for completed 15 minutes intervals, specifically up to 96 such intervals over a 24 hours of operation.
                     cePfePerfIntervalEntry 1.3.6.1.4.1.9.9.265.1.1.3.1 no-access
An entry containing performance information applicable to a particular PFE pipeline at a specific interval.
                         cePfePerfIntervalNumber 1.3.6.1.4.1.9.9.265.1.1.3.1.1 unsigned32 no-access
An interval number between 1 and 96, where 1 is the most recently completed 15 min interval and 96 is the 15 min interval completed 23 hours and 45 minutes prior to interval 1.
                         cePfePerfIntervalUtilization 1.3.6.1.4.1.9.9.265.1.1.3.1.2 intervalutilization read-only
The percentage of processor utilization by the PFE pipeline during this completed 15 min interval.
                         cePfePerfIntervalEfficiency 1.3.6.1.4.1.9.9.265.1.1.3.1.3 intervalefficiency read-only
The percentage of processor efficiency by the PFE pipeline during this completed 15 min interval. Under normal conditions, this number will be 100 and when efficiency starts degrading, it will start going down until it reaches zero.
                 cePfePerfTotalTable 1.3.6.1.4.1.9.9.265.1.1.4 no-access
This table contains the running utilization and efficiency of the PFE pipeline for the 24 hour period preceding the current interval. If the agent was restarted less than 24 hours ago, i.e., when there are less than 96 intervals in the cePfePerfIntervalTable, it will contain the running utiliza- tion and efficiency up to the last collected 15 minute inter- val.
                     cePfePerfTotalEntry 1.3.6.1.4.1.9.9.265.1.1.4.1 no-access
An entry containing performance information applicable to a particular PFE pipeline at the end of each interval in the cePfePerfIntervalTable.
                         cePfePerfTotalUtilization 1.3.6.1.4.1.9.9.265.1.1.4.1.1 totalutilization read-only
The running utilization by the PFE pipeline for the prece- ding 24 hrs.
                         cePfePerfTotalEfficiency 1.3.6.1.4.1.9.9.265.1.1.4.1.2 totalefficiency read-only
The running efficiency by the PFE pipeline for the preceding 24 hrs. Under normal conditions, this number will be 100 and when efficiency starts degrading, it will start going down until it reaches zero.
             cePfeHistory 1.3.6.1.4.1.9.9.265.1.2
                 cePfeHistNotifiesEnable 1.3.6.1.4.1.9.9.265.1.2.1 eventtype read-write
This object indicates what type of action should be taken by the agent when a event is generated.
                 cePfeHistTableSize 1.3.6.1.4.1.9.9.265.1.2.2 unsigned32 read-write
This object specifies the number of entries that the cePfeHistTable can contain. When a event is generated, and the capacity of the cePfeHistTable has reached the value specified by this object, then the agent deletes the oldest entity in order to accommodate the new entry. A value of '0' prevents any history from being retained.
                 cePfeHistTableLastIndex 1.3.6.1.4.1.9.9.265.1.2.3 unsigned32 read-only
This object specifies the value of the cePfeHistIndex object corresponding to the last entry added to the table by the agent. It will return zero if there are no entries in the table. If the management client uses the notifications defined by this module, then it can poll this object to determine whether it has missed a notification sent by the agent.
                 cePfeHistTable 1.3.6.1.4.1.9.9.265.1.2.4 no-access
This table contains a history of events generated by the agent.
                     cePfeHistEntry 1.3.6.1.4.1.9.9.265.1.2.4.1 no-access
An entry will exist for each event that has occured while cePfeHistNotifiesEnable object is set to 'log(2)' or 'logAndNotify(4)'.
                         cePfeHistIndex 1.3.6.1.4.1.9.9.265.1.2.4.1.1 unsigned32 no-access
An integer value uniquely identifying the entry in the table. The value of this object starts at '1' and monotonically increases for each event condition transition monitored by the agent. If the value of this object is '4294967295', the agent will reset the index to '1' upon monitoring the next event condition transition.
                         cePfeHistEntPhysIndex 1.3.6.1.4.1.9.9.265.1.2.4.1.2 physicalindex read-only
The value in this object is equal to the value of the entPhysicalIndex, from the Physical Entity Table (RFC 2037), that is associated with the PFE pipeline that has caused this event.
                         cePfeHistType 1.3.6.1.4.1.9.9.265.1.2.4.1.3 histeventtype read-only
This object describes the type of event that has occurred.
                         cePfeHistThld 1.3.6.1.4.1.9.9.265.1.2.4.1.4 percentage read-only
The configured value of the specific threshold.
                         cePfeHistValue 1.3.6.1.4.1.9.9.265.1.2.4.1.5 percentage read-only
The actual value of the specific performance objects, at the time of the sample, which is related to the threshold event.
                         cePfeHistRestartReason 1.3.6.1.4.1.9.9.265.1.2.4.1.6 displaystring read-only
The reason for which the PFE pipeline has restarted.
                         cePfeHistTimeStamp 1.3.6.1.4.1.9.9.265.1.2.4.1.7 timestamp read-only
This object specifies the value of the sysUpTime object at the time the event was generated.
         cePfeMIBConformance 1.3.6.1.4.1.9.9.265.2
             cePfeMIBCompliances 1.3.6.1.4.1.9.9.265.2.1
                 cePfeMIBPerformanceCompliance 1.3.6.1.4.1.9.9.265.2.1.1
An Entity-MIB implementation can implement this module to provide PFE pipeline performance history.
             cePfeMIBGroups 1.3.6.1.4.1.9.9.265.2.2
                 cePfeMIBPerformanceGroup 1.3.6.1.4.1.9.9.265.2.2.1
The collection of objects which are used to manage the per- formance history of the PFE pipeline.
                 cePfeMIBCurrentGroup 1.3.6.1.4.1.9.9.265.2.2.2
The collection of objects which are used to maintain the PFE processor's performance history over a 24 hour of operation.
                 cePfeMIBIntervalGroup 1.3.6.1.4.1.9.9.265.2.2.3
The collection of objects which are used to maintain the PFE processor's performance history over a 24 hour of operation.
                 cePfeMIBTotalGroup 1.3.6.1.4.1.9.9.265.2.2.4
The collection of objects which are used to manage the threshold configuration for the PFE pipeline performance.
                 cePfeMIBHistGroup 1.3.6.1.4.1.9.9.265.2.2.5
The collection of objects which are used to manage the threshold configuration for the PFE pipeline performance.
                 cePfeMIBHistEventGroup 1.3.6.1.4.1.9.9.265.2.2.6
The collection of objects which are used to generate a threshold event for the PFE pipeline performance.