CIENA-CES-MODULE-MIB: View SNMP OID List / Download MIB
VENDOR: CIENA CORPORATION
Home | MIB: CIENA-CES-MODULE-MIB | |||
---|---|---|---|---|
Download as: |
Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
|
|||
Object Name | OID | Type | Access | Info |
cienaCesModuleMIB | 1.3.6.1.4.1.1271.2.1.2 |
This module defines the module configuration objects and also the objects required for module related notifications. |
||
cienaCesModuleMIBObjects | 1.3.6.1.4.1.1271.2.1.2.1 | |||
cienaCesModuleGlobal | 1.3.6.1.4.1.1271.2.1.2.1.1 | |||
cienaCesModuleGlobalPostState | 1.3.6.1.4.1.1271.2.1.2.1.1.1 | cienaglobalstate | read-only |
This object indicates the global POST state for the system. |
cienaCesModule | 1.3.6.1.4.1.1271.2.1.2.1.2 | |||
cienaCesModuleTable | 1.3.6.1.4.1.1271.2.1.2.1.2.1 | no-access |
The (conceptual) table listing the modules configured and detected. |
|
1.3.6.1.4.1.1271.2.1.2.1.2.1.1 | no-access |
An entry (conceptual row) in the cienaCesModuleTable. |
||
cienaCesModuleChassisIndx | 1.3.6.1.4.1.1271.2.1.2.1.2.1.1.1 | unsigned32 | no-access |
This object indicates the chassis index for the module. |
cienaCesModuleShelfIndx | 1.3.6.1.4.1.1271.2.1.2.1.2.1.1.2 | unsigned32 | no-access |
This object indicates the shelf index for the module. |
cienaCesModuleSlotIndx | 1.3.6.1.4.1.1271.2.1.2.1.2.1.1.3 | unsigned32 | no-access |
This object indicates the slot index for the module. |
cienaCesModuleModel | 1.3.6.1.4.1.1271.2.1.2.1.2.1.1.4 | displaystring | read-only |
This object indicates the module model. |
cienaCesModuleType | 1.3.6.1.4.1.1271.2.1.2.1.2.1.1.5 | integer | read-only |
This object indicates whether this is a single module, control timing module, I/O module or fabric module. Enumeration: 'unknown': 1, 'lm': 3, 'sm': 4, 'invalid': 0, 'ctm': 2. |
cienaCesModuleDescription | 1.3.6.1.4.1.1271.2.1.2.1.2.1.1.6 | displaystring | read-only |
This object indicates the description of the module. |
cienaCesModuleAdminState | 1.3.6.1.4.1.1271.2.1.2.1.2.1.1.7 | integer | read-only |
This object indicates the administrative state of the module. Enumeration: 'disabled': 2, 'enabled': 1, 'shutdown': 3. |
cienaCesModuleOperState | 1.3.6.1.4.1.1271.2.1.2.1.2.1.1.8 | integer | read-only |
This object indicates the operational state of the module. Enumeration: 'unequipped': 2, 'faulted': 6, 'fastReload': 10, 'krnDisable': 15, 'appFault': 16, 'powerdown': 18, 'enabled': 5, 'poweroff': 8, 'unsupported': 12, 'installing': 13, 'disabled': 4, 'failed': 14, 'init': 3, 'hitlessInit': 9, 'krnInit': 11, 'booting': 17, 'uninstalled': 1, 'hotswap': 7. |
cienaCesModuleProtectionRole | 1.3.6.1.4.1.1271.2.1.2.1.2.1.1.9 | integer | read-only |
This object indicates the redundant administrative state of the module. Enumeration: 'none': 1, 'primary': 2, 'secondary': 3. |
cienaCesModuleStandbyStatus | 1.3.6.1.4.1.1271.2.1.2.1.2.1.1.10 | integer | read-only |
This object indicates the standby status of the module. Enumeration: 'none': 0, 'warm': 2, 'cold': 1, 'protected': 4, 'hot': 3. |
cienaCesModuleLastRebootReason | 1.3.6.1.4.1.1271.2.1.2.1.2.1.1.11 | integer | read-only |
This object indicates the last reboot reason of the module. Enumeration: 'processorWarmRestart': 17, 'upgrade': 7, 'coldRestart': 18, 'cli': 8, 'communicationFailure': 12, 'bootFailure': 15, 'pwrFail': 3, 'unknown': 1, 'failOver': 10, 'unprotectedFailure': 14, 'snmp': 2, 'errorHandler': 5, 'softwareRevert': 16, 'primaryRestart': 19, 'resetButton': 9, 'watchdog': 6, 'configurationRevert': 13, 'appLoad': 4, 'faultManager': 11. |
cienaCesModuleAdminPostState | 1.3.6.1.4.1.1271.2.1.2.1.2.1.1.12 | cienaglobalstate | read-only |
This object sets the POST administrative state for the given module. |
cienaCesModuleOperPostState | 1.3.6.1.4.1.1271.2.1.2.1.2.1.1.13 | cienaglobalstate | read-only |
This object indicates the POST operational state for the given module. |
cienaCesModuleTrapState | 1.3.6.1.4.1.1271.2.1.2.1.2.1.1.16 | cienaglobalstate | read-write |
This object indicates whether the device generates notifications for this module. |
cienaCesModuleChassisNotifIndx | 1.3.6.1.4.1.1271.2.1.2.1.2.1.1.17 | unsigned32 | no-access |
This object indicates the chassis index for the module used in trap definition. |
cienaCesModuleShelfNotifIndx | 1.3.6.1.4.1.1271.2.1.2.1.2.1.1.18 | unsigned32 | no-access |
This object indicates the shelf index for the module used in trap definition. |
cienaCesModuleSlotNotifIndx | 1.3.6.1.4.1.1271.2.1.2.1.2.1.1.19 | unsigned32 | no-access |
This object indicates the slot index for the module used in trap definition. |
cienaCesModuleSlotName | 1.3.6.1.4.1.1271.2.1.2.1.2.1.1.20 | displaystring | read-only |
This object indicates the slot name that the module is installed in. |
cienaCesModuleDescriptionTable | 1.3.6.1.4.1.1271.2.1.2.1.2.2 | no-access |
The (conceptual) table listing the description of physical attributes of the modules. |
|
1.3.6.1.4.1.1271.2.1.2.1.2.2.1 | no-access |
An entry (conceptual row) in the cienaCesModuleDescriptionTable. |
||
cienaCesModuleDescriptionBoardName | 1.3.6.1.4.1.1271.2.1.2.1.2.2.1.1 | displaystring | read-only |
This object indicates the module name. |
cienaCesModuleDescriptionBoardPartNum | 1.3.6.1.4.1.1271.2.1.2.1.2.2.1.2 | displaystring | read-only |
This object indicates the board part number. |
cienaCesModuleDescriptionBoardSerialNum | 1.3.6.1.4.1.1271.2.1.2.1.2.2.1.3 | displaystring | read-only |
This object indicates the board serial number. |
cienaCesModuleDescriptionBoardDesc | 1.3.6.1.4.1.1271.2.1.2.1.2.2.1.4 | displaystring | read-only |
This object indicates the board description. |
cienaCesModuleDescriptionHwVersion | 1.3.6.1.4.1.1271.2.1.2.1.2.2.1.5 | displaystring | read-only |
This object indicates the module hardware version. |
cienaCesModuleDescriptionMfgDate | 1.3.6.1.4.1.1271.2.1.2.1.2.2.1.6 | displaystring | read-only |
This object indicates the module manufacturing date. |
cienaCesModuleDescriptionBaseMac | 1.3.6.1.4.1.1271.2.1.2.1.2.2.1.7 | macaddress | read-only |
This object indicates the module base MAC address. |
cienaCesModuleDescriptionUpTime | 1.3.6.1.4.1.1271.2.1.2.1.2.2.1.8 | timeticks | read-only |
This object indicates the module up time (in hundredths of a second) since the module was last re-initialized. |
cienaCesModuleDescriptionTotalNumPorts | 1.3.6.1.4.1.1271.2.1.2.1.2.2.1.9 | integer32 | read-only |
This object indicates the number of ports on this module. |
cienaCesModuleTempSensorTable | 1.3.6.1.4.1.1271.2.1.2.1.2.3 | no-access |
The (conceptual) table listing the temperature sensors of the modules. |
|
1.3.6.1.4.1.1271.2.1.2.1.2.3.1 | no-access |
An entry (conceptual row) in the cienaCesModuleTempSensorTable. |
||
cienaCesModuleSensorIndx | 1.3.6.1.4.1.1271.2.1.2.1.2.3.1.1 | integer32 | no-access |
This object indicates the unique index in the table along with cienaCesModuleIndx. |
cienaCesModuleSensorDescription | 1.3.6.1.4.1.1271.2.1.2.1.2.3.1.2 | displaystring | read-only |
This object indicates the sensor description. |
cienaCesModuleSensorCurrentTemp | 1.3.6.1.4.1.1271.2.1.2.1.2.3.1.3 | integer32 | read-only |
This object indicates the current temperature of the module. |
cienaCesModuleSensorHighTemp | 1.3.6.1.4.1.1271.2.1.2.1.2.3.1.4 | integer32 | read-only |
This object indicates the highest temperature this module has reached since the last reboot. |
cienaCesModuleSensorLowTemp | 1.3.6.1.4.1.1271.2.1.2.1.2.3.1.5 | integer32 | read-only |
This object indicates the lowest temperature this module has reached since the last reboot |
cienaCesModuleSensorHighTempThreshold | 1.3.6.1.4.1.1271.2.1.2.1.2.3.1.6 | integer32 | read-only |
This object indicates the high threshold for this module temperature. |
cienaCesModuleSensorLowTempThreshold | 1.3.6.1.4.1.1271.2.1.2.1.2.3.1.7 | integer32 | read-only |
This object indicates the low threshold for this module temperature. |
cienaCesModuleSensorNotifIndx | 1.3.6.1.4.1.1271.2.1.2.1.2.3.1.8 | integer32 | no-access |
This object indicates the unique index in the table used for trap definition. |
cienaCesSwModule | 1.3.6.1.4.1.1271.2.1.2.1.2.4 | |||
cienaCesGlobalSwState | 1.3.6.1.4.1.1271.2.1.2.1.2.4.1 | integer | read-only |
The global software state of the system. Enumeration: 'downloading': 2, 'installing': 3, 'reverting': 6, 'running': 7, 'validating': 5, 'idle': 1, 'activating': 4. |
cienaCesModuleSwTable | 1.3.6.1.4.1.1271.2.1.2.1.2.4.2 | no-access |
The (conceptual) table listing the software package attributes on the modules. |
|
1.3.6.1.4.1.1271.2.1.2.1.2.4.2.1 | no-access |
An entry (conceptual row) in the cienaCesModuleSwTable. |
||
cienaCesModuleSwState | 1.3.6.1.4.1.1271.2.1.2.1.2.4.2.1.1 | swmodulestate | read-only |
The software state on the module. |
cienaCesModuleSwRunningRelease | 1.3.6.1.4.1.1271.2.1.2.1.2.4.2.1.2 | displaystring | read-only |
Software package version that is currently running on the module. |
cienaCesModuleSwRunningReleasePartition | 1.3.6.1.4.1.1271.2.1.2.1.2.4.2.1.3 | unsigned32 | read-only |
Release partition where the current running release is installed. |
cienaCesModuleSwReleasePartition0Pkg | 1.3.6.1.4.1.1271.2.1.2.1.2.4.2.1.4 | displaystring | read-only |
Release partition 0 software package version. |
cienaCesModuleSwReleasePartition0PkgStatus | 1.3.6.1.4.1.1271.2.1.2.1.2.4.2.1.5 | swpkgstatus | read-only |
Release partition 0 software package status. |
cienaCesModuleSwReleasePartition1Pkg | 1.3.6.1.4.1.1271.2.1.2.1.2.4.2.1.6 | displaystring | read-only |
Release partition 1 software package version. |
cienaCesModuleSwReleasePartition1PkgStatus | 1.3.6.1.4.1.1271.2.1.2.1.2.4.2.1.7 | swpkgstatus | read-only |
Release partition 1 software package status. |
cienaCesModuleSwReleasePartition2Pkg | 1.3.6.1.4.1.1271.2.1.2.1.2.4.2.1.8 | displaystring | read-only |
Release partition 2 software package version. |
cienaCesModuleSwReleasePartition2PkgStatus | 1.3.6.1.4.1.1271.2.1.2.1.2.4.2.1.9 | swpkgstatus | read-only |
Release partition 2 software package status. |
cienaCesModuleSwBank0KernelVersion | 1.3.6.1.4.1.1271.2.1.2.1.2.4.2.1.10 | displaystring | read-only |
Bank0 kernel version. |
cienaCesModuleSwBank0KernelStatus | 1.3.6.1.4.1.1271.2.1.2.1.2.4.2.1.11 | swpkgstatus | read-only |
Bank0 kernel software status. |
cienaCesModuleSwBank1KernelVersion | 1.3.6.1.4.1.1271.2.1.2.1.2.4.2.1.12 | displaystring | read-only |
Bank1 kernel version. |
cienaCesModuleSwBank1KernelStatus | 1.3.6.1.4.1.1271.2.1.2.1.2.4.2.1.13 | swpkgstatus | read-only |
Bank1 kernel status. |
cienaCesModuleSwBank0UbootVersion | 1.3.6.1.4.1.1271.2.1.2.1.2.4.2.1.14 | displaystring | read-only |
Bank0 U-boot version. |
cienaCesModuleSwBank0UbootStatus | 1.3.6.1.4.1.1271.2.1.2.1.2.4.2.1.15 | swpkgstatus | read-only |
Bank0 U-boot status. |
cienaCesModuleSwBank1UbootVersion | 1.3.6.1.4.1.1271.2.1.2.1.2.4.2.1.16 | displaystring | read-only |
Bank1 U-boot version. |
cienaCesModuleSwBank1UbootStatus | 1.3.6.1.4.1.1271.2.1.2.1.2.4.2.1.17 | swpkgstatus | read-only |
Bank0 U-boot status. |
cienaCesModuleSwUbootGoldVersion | 1.3.6.1.4.1.1271.2.1.2.1.2.4.2.1.18 | displaystring | read-only |
U-boot Gold version. |
cienaCesModuleSwUbootGoldStatus | 1.3.6.1.4.1.1271.2.1.2.1.2.4.2.1.19 | swpkgstatus | read-only |
U-boot Gold status. |
cienaCesModuleSwMIBVer | 1.3.6.1.4.1.1271.2.1.2.1.2.4.2.1.20 | displaystring | read-only |
This MIB object shows the MIB version currently supported. |
cienaCesModulePOSTErrorTable | 1.3.6.1.4.1.1271.2.1.2.1.2.5 | no-access |
The (conceptual) table for viewing POST error on the modules. |
|
1.3.6.1.4.1.1271.2.1.2.1.2.5.1 | no-access |
An entry (conceptual row) in the cienaCesModulePOSTErrorResultsTable. |
||
cienaCesModulePOSTErrorIndex | 1.3.6.1.4.1.1271.2.1.2.1.2.5.1.1 | integer | no-access |
Index of the POST error for the module. |
cienaCesModulePOSTErrorDescription | 1.3.6.1.4.1.1271.2.1.2.1.2.5.1.2 | octet string | read-only |
A description of the module POST error. |
cienaCesModulePOSTErrorSeverity | 1.3.6.1.4.1.1271.2.1.2.1.2.5.1.3 | integer | read-only |
Severity of the POST error for the module. Enumeration: 'unknown': 0, 'severe': 2, 'fatal': 1, 'warning': 3. |
cienaCesModulePOSTErrorScope | 1.3.6.1.4.1.1271.2.1.2.1.2.5.1.4 | integer | read-only |
Scope of the POST error for the module. Enumeration: 'blade': 2, 'unknown': 0, 'chassis': 1, 'port': 3. |
cienaCesModulePOSTScopeIndex | 1.3.6.1.4.1.1271.2.1.2.1.2.5.1.5 | integer | read-only |
When scope is a port this object identifies the port number. |
cienaCesModuleResourceHealthTable | 1.3.6.1.4.1.1271.2.1.2.1.2.6 | no-access |
Table listing the health information of dataplane resources. |
|
1.3.6.1.4.1.1271.2.1.2.1.2.6.1 | no-access |
An entry in the cienaCesModuleResourceHealthTable. |
||
cienaCesModuleResourceHealthSubCategory | 1.3.6.1.4.1.1271.2.1.2.1.2.6.1.1 | integer | no-access |
The sub-category of the dataplane resource being monitored. - 'none' is an enumeration placeholder. Enumeration: 'pltfmBscp': 15, 'pltfmCLScheduler': 12, 'pbtTransit': 6, 'pltfmHighRateTokenBucket': 16, 'pltfmVOQ': 11, 'pltfmLowRateTokenBucket': 17, 'pltfmPpIngressL2Xform': 23, 'pltfmEgressTunnel': 8, 'pltfmNpProtectionGroup': 34, 'pltfmParentMeter': 18, 'pltfmNpFastTimer10msec': 29, 'pltfmFQScheduler': 13, 'accessFlow': 3, 'pltfmLmPowerBudget': 22, 'pltfmTokenBucket': 7, 'pltfmPpEgressL2Xform': 24, 'qosFlow': 2, 'pltfmNpMaintPoint': 26, 'subPort': 1, 'pltfmNpSlowTimer': 32, 'pltfmVirtTcamEntries': 9, 'pltfmEgressShapingCIR': 14, 'pltfmNpFastTimer1sec': 31, 'pltfmAclTcamEntries': 10, 'logicalInterfaces': 21, 'queueGroupInstance': 4, 'pltfmPpInternalTcam': 25, 'schedulerInstance': 5, 'pltfmNpMaintPointSession': 27, 'none': 0, 'pltfmNpFastTimer100msec': 30, 'pltfmNpWatchdogTimer': 33, 'pltfmNpFastTimer300Hz': 28, 'pltfmChildMeter': 19, 'pltfmL2UserTypes': 20. |
cienaCesModuleResourceDeviceIndx | 1.3.6.1.4.1.1271.2.1.2.1.2.6.1.2 | unsigned32 | no-access |
Index of the device being monitored. |
cienaCesModuleResourceHealthState | 1.3.6.1.4.1.1271.2.1.2.1.2.6.1.3 | tcehealthstatus | read-only |
Health state of the dataplane resource being monitored. |
cienaCesModuleResourceHealthCurrMeasurement | 1.3.6.1.4.1.1271.2.1.2.1.2.6.1.4 | unsigned32 | read-only |
Current value of the dataplane resource being monitored. |
cienaCesModuleResourceHealthMaxMeasurement | 1.3.6.1.4.1.1271.2.1.2.1.2.6.1.5 | unsigned32 | read-only |
The maximum recorded value of the dataplane resource being monitored. |
cienaCesModuleResourceHealthMaxThreshold | 1.3.6.1.4.1.1271.2.1.2.1.2.6.1.6 | unsigned32 | read-only |
The maximum possible value for the dataplane resource being monitored. |
cienaCesModuleIDPTable | 1.3.6.1.4.1.1271.2.1.2.1.2.8 | no-access |
The (conceptual) table listing the description of ID Prom contents of the modules. |
|
1.3.6.1.4.1.1271.2.1.2.1.2.8.1 | no-access |
An entry (conceptual row) in the cienaCesModuleIDPTable. |
||
cienaCesModuleIDPEthBaseMac | 1.3.6.1.4.1.1271.2.1.2.1.2.8.1.1 | macaddress | read-only |
This object indicates the module Ethernet Base MAC address stored in the module IDP. |
cienaCesModuleIDPEthBaseMacRange | 1.3.6.1.4.1.1271.2.1.2.1.2.8.1.2 | integer32 | read-only |
This object indicates the Ethernet MAC address range stored in the module IDP. |
cienaCesModuleIDPModuleSerialNumber | 1.3.6.1.4.1.1271.2.1.2.1.2.8.1.3 | displaystring | read-only |
This object indicates the Module Serial Number stored in the module IDP. |
cienaCesModuleIDPModelPartNumber | 1.3.6.1.4.1.1271.2.1.2.1.2.8.1.4 | displaystring | read-only |
This object indicates the Model Part Number stored in the module IDP. |
cienaCesModuleIDPModelRevision | 1.3.6.1.4.1.1271.2.1.2.1.2.8.1.5 | displaystring | read-only |
This object indicates the Model Revision stored in the module IDP. |
cienaCesModuleIDPProductID | 1.3.6.1.4.1.1271.2.1.2.1.2.8.1.6 | displaystring | read-only |
This object indicates the Module Product ID stored in the module IDP. |
cienaCesModuleIDPMfgDate | 1.3.6.1.4.1.1271.2.1.2.1.2.8.1.7 | displaystring | read-only |
This object indicates the Manufactured Date stored in the module IDP. |
cienaCesModuleIDPCleiCode | 1.3.6.1.4.1.1271.2.1.2.1.2.8.1.8 | displaystring | read-only |
This object indicates the CLEI Code stored in the module IDP. |
cienaCesModuleIDPBarcode | 1.3.6.1.4.1.1271.2.1.2.1.2.8.1.9 | displaystring | read-only |
This object indicates the Barcode stored in the module IDP. |
cienaCesModuleIDPSWCompat | 1.3.6.1.4.1.1271.2.1.2.1.2.8.1.10 | integer32 | read-only |
This object indicates the Software Compatibility Number stored in the module IDP. |
cienaCesModuleIDPFTC | 1.3.6.1.4.1.1271.2.1.2.1.2.8.1.11 | integer32 | read-only |
This object indicates the Functional Test Count stored in the module IDP. |
cienaCesModuleNotifAttrs | 1.3.6.1.4.1.1271.2.1.2.1.3 | |||
cienaCesModuleSystemProtectionMode | 1.3.6.1.4.1.1271.2.1.2.1.3.1 | integer | no-access |
This object indicates the protection mode of the system. Enumeration: 'unprotected': 1, 'warm': 3, 'cold': 2, 'hot': 4. |
cienaCesModuleSwitchOverReason | 1.3.6.1.4.1.1271.2.1.2.1.3.2 | integer | no-access |
This object indicates the reason the SwitchOver happened. The following combinations determine the value of this object: CTM failure - Deprov mode - Cold FailOver User Initiated - Deprov Mode - Cold SwitchOver CTM failure - Audit mode - Hot FailOver User initiated - Audit mode - Hot SwitchOver. Enumeration: 'hotFailOver': 4, 'coldFailOver': 1, 'hotSwitchOver': 3, 'coldSwitchOver': 2. |
cienaCesModuleNotifTable | 1.3.6.1.4.1.1271.2.1.2.1.3.3 | no-access |
The (conceptual) table to define the notification variable bindings. |
|
1.3.6.1.4.1.1271.2.1.2.1.3.3.1 | no-access |
An entry (conceptual row) in the cienaCesModuleNotifEntryTable. |
||
cienaCesModuleHealthCategory | 1.3.6.1.4.1.1271.2.1.2.1.3.3.1.1 | tcehealthcategory | no-access |
This object indicates the health category that the Health Manager monitors on the module. |
cienaCesModuleHealthSubCategory | 1.3.6.1.4.1.1271.2.1.2.1.3.3.1.2 | unsigned32 | no-access |
This object indicates the health sub category that the Health Manager monitors on the module. |
cienaCesModuleHealthStatus | 1.3.6.1.4.1.1271.2.1.2.1.3.3.1.3 | tcehealthstatus | no-access |
This object indicates the current health status of health category and its sub category being monitored on the module. |
cienaCesModuleHealthStatusLast | 1.3.6.1.4.1.1271.2.1.2.1.3.3.1.4 | tcehealthstatus | no-access |
This object indicates the last known health status of health category and its sub category being monitored on the module. |
cienaCesModuleHealthOriginType | 1.3.6.1.4.1.1271.2.1.2.1.3.3.1.5 | healthorigintype | no-access |
This object indicates the origin of the health status notification. |
cienaCesModuleHealthOriginName | 1.3.6.1.4.1.1271.2.1.2.1.3.3.1.6 | displaystring | no-access |
This object indicates the origin name of the health status notification. |
cienaCesModuleHealthOriginUnitId | 1.3.6.1.4.1.1271.2.1.2.1.3.3.1.7 | unsigned32 | no-access |
This object indicates the origin id of the health notification. |
cienaCesModuleConformance | 1.3.6.1.4.1.1271.2.1.2.2 | |||
cienaCesModuleMIBCompliances | 1.3.6.1.4.1.1271.2.1.2.2.1 | |||
cienaCesModuleMIBGroups | 1.3.6.1.4.1.1271.2.1.2.2.2 | |||
moduleConfigGroup | 1.3.6.1.4.1.1271.2.1.2.2.2.1 |
A collection of objects providing information about configuration table. |
||
moduleDescriptionGroup | 1.3.6.1.4.1.1271.2.1.2.2.2.2 |
A collection of objects providing information about module capabilities. |
||
moduleSensorGroup | 1.3.6.1.4.1.1271.2.1.2.2.2.3 |
A collection of objects providing information of module temperature sensors. |
||
moduleNotifGroup | 1.3.6.1.4.1.1271.2.1.2.2.2.4 |
A collection of objects providing information about module notifications. |
||
modulePostErrorGroup | 1.3.6.1.4.1.1271.2.1.2.2.2.5 |
A collection of objects providing information of module POST errors. |
||
cienaCesModuleMIBNotificationPrefix | 1.3.6.1.4.1.1271.2.2.3 | |||
cienaCesModuleMIBNotifications | 1.3.6.1.4.1.1271.2.2.3.0 | |||
cienaCesModuleStateChangeNotification | 1.3.6.1.4.1.1271.2.2.3.0.1 |
A cienaCesModuleStateChange notification is sent when the operational state of the module is changed. To enable the device to send this notification: - cienaCesModuleAllModulesTrapState needs to be set to enabled. - cienaCesModuleTrapState for the module needs to be set to enabled. The above values are set to enabled by default. Variable bindings include: cienaGlobalSeverity, cienaGlobalMacAddress, cienaCesModuleChassisNotifIndx, cienaCesModuleShelfNotifIndx, cienaCesModuleSlotNotifIndx, cienaCesModuleAdminState, and cienaCesModuleOperState. |
||
cienaCesModuleHealthStatusUnknownNotification | 1.3.6.1.4.1.1271.2.2.3.0.2 |
This notification is sent whenever the Health Manager detects a status change to unknown. To enable the device to send this notification: - cienaCesModuleAllModulesTrapState needs to be set to enabled. - cienaCesModuleTrapState for the module needs to be set to enabled. - cienaCesModuleAllModulesHealthTrapState needs to be set to enabled. The above values are set to enabled by default. Variable bindings include: cienaGlobalSeverity, cienaGlobalMacAddress, cienaCesModuleChassisNotifIndx, cienaCesModuleShelfNotifIndx, cienaCesModuleSlotNotifIndx, cienaCesModuleHealthOriginType, cienaCesModuleHealthOriginName, cienaCesModuleHealthOriginUnitId, cienaCesModuleHealthCategory, cienaCesModuleHealthSubCategory, cienaCesModuleHealthStatus, and cienaCesModuleHealthStatusLast. |
||
cienaCesModuleHealthStatusWarningNotification | 1.3.6.1.4.1.1271.2.2.3.0.3 |
This notification is sent whenever the Health Manager detects a status change to warning. To enable the device to send this notification: - cienaCesModuleAllModulesTrapState needs to be set to enabled. - cienaCesModuleTrapState for the module needs to be set to enabled. - cienaCesModuleAllModulesHealthTrapState needs to be set to enabled. The above values are set to enabled by default. Variable bindings include: cienaGlobalSeverity, cienaGlobalMacAddress, cienaCesModuleChassisNotifIndx, cienaCesModuleShelfNotifIndx, cienaCesModuleSlotNotifIndx, cienaCesModuleHealthOriginType, cienaCesModuleHealthOriginName, cienaCesModuleHealthOriginUnitId, cienaCesModuleHealthCategory, cienaCesModuleHealthSubCategory, cienaCesModuleHealthStatus, and cienaCesModuleHealthStatusLast. |
||
cienaCesModuleHealthStatusFaultedNotification | 1.3.6.1.4.1.1271.2.2.3.0.4 |
This notification is sent whenever the Health Manager detects a status change to faulted. To enable the device to send this notification: - cienaCesModuleAllModulesTrapState needs to be set to enabled. - cienaCesModuleTrapState for the module needs to be set to enabled. - cienaCesModuleAllModulesHealthTrapState needs to be set to enabled The above values are set to enabled by default. Variable bindings include: cienaGlobalSeverity, cienaGlobalMacAddress, cienaCesModuleChassisNotifIndx, cienaCesModuleShelfNotifIndx, cienaCesModuleSlotNotifIndx, cienaCesModuleHealthOriginType, cienaCesModuleHealthOriginName, cienaCesModuleHealthOriginUnitId, cienaCesModuleHealthCategory, cienaCesModuleHealthSubCategory, cienaCesModuleHealthStatus, and cienaCesModuleHealthStatusLast. |
||
cienaCesModuleHealthStatusDegradedNotification | 1.3.6.1.4.1.1271.2.2.3.0.5 |
This notification is sent whenever the Health Manager detects a status change to degraded. To enable the device to send this notification: - cienaCesModuleAllModulesTrapState needs to be set to enabled. - cienaCesModuleTrapState for the module needs to be set to enabled. - cienaCesModuleAllModulesHealthTrapState needs to be set to enabled The above values are set to enabled by default. Variable bindings include: cienaGlobalSeverity, cienaGlobalMacAddress, cienaCesModuleChassisNotifIndx, cienaCesModuleShelfNotifIndx, cienaCesModuleSlotNotifIndx, cienaCesModuleHealthOriginType, cienaCesModuleHealthOriginName, cienaCesModuleHealthOriginUnitId, cienaCesModuleHealthCategory, cienaCesModuleHealthSubCategory, cienaCesModuleHealthStatus, and cienaCesModuleHealthStatusLast. |
||
cienaCesModuleHealthStatusGoodNotification | 1.3.6.1.4.1.1271.2.2.3.0.6 |
This notification is sent whenever the Health Manager detects a status change to normal. To enable the device to send this notification: - cienaCesModuleAllModulesTrapState needs to be set to enabled. - cienaCesModuleTrapState for the module needs to be set to enabled. - cienaCesModuleAllModulesHealthTrapState needs to be set to enabled The above values are set to enabled by default. Variable bindings include: cienaGlobalSeverity, cienaGlobalMacAddress, cienaCesModuleChassisNotifIndx, cienaCesModuleShelfNotifIndx, cienaCesModuleSlotNotifIndx, cienaCesModuleHealthOriginType, cienaCesModuleHealthOriginName, cienaCesModuleHealthOriginUnitId, cienaCesModuleHealthCategory, cienaCesModuleHealthSubCategory, cienaCesModuleHealthStatus, and cienaCesModuleHealthStatusLast. |
||
cienaCesModuleSensorHighTempNotification | 1.3.6.1.4.1.1271.2.2.3.0.7 |
This notification is sent when the cienaCesModuleSensor temperature exceeds the high temperature threshold for the module. To enable the device to send this notification: - cienaCesModuleAllModulesTrapState needs to be set to enabled. - cienaCesModuleSensorTrapState needs to be set to enabled. The above values are set to enabled by default. Variable bindings include: cienaGlobalSeverity, cienaGlobalMacAddress, cienaCesModuleChassisNotifIndx, cienaCesModuleShelfNotifIndx, cienaCesModuleSlotNotifIndx, cienaCesModuleSensorNotifIndx, cienaCesModuleSensorDescription, cienaCesModuleSensorCurrentTemp, and cienaCesModuleSensorHighTempThreshold. |
||
cienaCesModuleSensorLowTempNotification | 1.3.6.1.4.1.1271.2.2.3.0.8 |
This notification is sent when the cienaCesModuleSensor falls below the low temperature threshold for the module. To enable the device to send this notification: - cienaCesModuleAllModulesTrapState needs to be set to enabled. - cienaCesModuleSensorTrapState needs to be set to enabled. The above values are set to enabled by default. Variable bindings include: cienaGlobalSeverity, cienaGlobalMacAddress, cienaCesModuleChassisNotifIndx, cienaCesModuleShelfNotifIndx, cienaCesModuleSlotNotifIndx, cienaCesModuleSensorNotifIndx, cienaCesModuleSensorDescription, cienaCesModuleSensorCurrentTemp, and cienaCesModuleSensorLowTempThreshold. |
||
cienaCesModuleSensorNormalTempNotification | 1.3.6.1.4.1.1271.2.2.3.0.9 |
This notification is sent if the cienaCesModule temperature changes from previously reported high or low temperature exceeding thresholds to normal temperature. To enable the device to send this notification: - cienaCesModuleAllModulesTrapState needs to be set to enabled. - cienaCesModuleSensorTrapState needs to be set to enabled. The above values are set to enabled by default. Variable bindings include: cienaGlobalSeverity, cienaGlobalMacAddress, cienaCesModuleChassisNotifIndx, cienaCesModuleShelfNotifIndx, cienaCesModuleSlotNotifIndx, cienaCesModuleSensorNotifIndx, cienaCesModuleSensorDescription, cienaCesModuleSensorCurrentTemp, cienaCesModuleSensorLowTemp, and cienaCesModuleSensorHighTemp. |
||
cienaCesModuleHASwitchOverNotification | 1.3.6.1.4.1.1271.2.2.3.0.10 |
This notification is sent for CTM switchover. To enable the device to send this notification: - cienaCesModuleAllModulesTrapState needs to be set to enabled. - cienaCesModuleHATrapState needs to be set to enabled. The above values are set to enabled by default. Variable bindings include: cienaGlobalSeverity, cienaGlobalMacAddress, cienaCesModuleChassisNotifIndx, cienaCesModuleShelfNotifIndx, cienaCesModuleSlotNotifIndx, cienaCesModuleSwitchOverReason, cienaCesModuleAdminState, and cienaCesModuleOperState. |
||
cienaCesModuleProtectionModeColdNotification | 1.3.6.1.4.1.1271.2.2.3.0.11 |
This notification is sent when the protection mode of the system changes to cold. A COLD protection level is the lowest level of protection. It implies that the secondary CTM is ready to assume the function of the primary CTM but a failure causing a failover would be service impacting. The secondary CTM has been synchronized with the same software package, configuration files, etc such that it will return the same state as the previous primary CTM. The protection state of the primary CTM shall not transition from NONE to PROTECTED until the secondary CTM has completed the synchronization. In the case of a failure on the primary CTM, the secondary CTM will immediately assume primary status, finish its initialization and reboot the PSLMs. The primary CTM will reapply the configuration to the PSLMs after they have booted. Any unsaved configuration changes will NOT be lost on a failover as configuration changes are propagated to the secondary CTM configuration. To enable the device to send this notification: - cienaCesModuleAllModulesTrapState needs to be set to enabled. - cienaCesModuleProtectionModeTrapState needs to be set to enabled. The above values are set to enabled by default. Variable bindings include: cienaGlobalSeverity, cienaGlobalMacAddress, and cienaCesModuleSystemProtectionMode. |
||
cienaCesModuleProtectionModeWarmNotification | 1.3.6.1.4.1.1271.2.2.3.0.12 |
This notification is sent when the protection mode of the system changes to warm. This state is not supported on the 5410 platform. To enable the device to send this notification: - cienaCesModuleAllModulesTrapState needs to be set to enabled. - cienaCesModuleProtectionModeTrapState needs to be set to enabled. The above values are set to enabled by default. Variable bindings include: cienaGlobalSeverity, cienaGlobalMacAddress, and cienaCesModuleSystemProtectionMode. |
||
cienaCesModuleProtectionModeUnprotectedNotification | 1.3.6.1.4.1.1271.2.2.3.0.13 |
This notification is sent when the protection mode of the system changes to unprotected. A protection level of unprotected implies that there is no secondary CTM present in the system or that the current secondary CTM is not in a state to provide any protection. In the case of the CTM failure, the primary CTM will reboot and subsequently reboot all the PSLMs, causing loss of existing switched traffic patterns. To enable the device to send this notification: - cienaCesModuleAllModulesTrapState needs to be set to enabled. - cienaCesModuleProtectionModeTrapState needs to be set to enabled. The above values are set to enabled by default. Variable bindings include: cienaGlobalSeverity, cienaGlobalMacAddress, and cienaCesModuleSystemProtectionMode. |
||
cienaCesModuleProtectionModeHotNotification | 1.3.6.1.4.1.1271.2.2.3.0.14 |
This notification is sent when the protection mode of the system changes to hot. A HOT protection level is the highest level of protection. It implies that the secondary CTM is ready to assume the function of the primary CTM and a failure causing a failover would NOT be service impacting. The secondary CTM has been synchronized with the same software package, configuration files, etc such that it will return the same state as the previous primary CTM. The protection state of the primary CTM shall not transition from NONE to PROTECTED until the secondary CTM has completed the synchronization. In the case of a failure on the primary CTM, the secondary CTM will immediately assume primary status, finish its initialization and audit the PSLMs. All current established traffic patterns will be maintained with a minimal loss of traffic. Any unsaved configuration changes will NOT be lost on a failover as configuration changes are propagated to the secondary CTM configuration. To enable the device to send this notification: - cienaCesModuleAllModulesTrapState needs to be set to enabled. - cienaCesModuleProtectionModeTrapState needs to be set to enabled. The above values are set to enabled by default. Variable bindings include: cienaGlobalSeverity, cienaGlobalMacAddress, and cienaCesModuleSystemProtectionMode. |
||
cienaCesModulePostErrorNotification | 1.3.6.1.4.1.1271.2.2.3.0.15 |
This notification is sent when a module POST error is detected. To enable the device to send this notification: - cienaCesModuleAllModulesTrapState needs to be set to enabled. - cienaCesModulePOSTErrorTrapState needs to be set to enabled. The above values are set to enabled by default. Variable bindings include: cienaGlobalSeverity, cienaGlobalMacAddress, cienaCesModuleChassisNotifIndx, cienaCesModuleShelfNotifIndx, cienaCesModuleSlotNotifIndx, and cienaCesModulePOSTErrorDescription. |
||
cienaCesModuleFastReloadUnsuccessfulNotification | 1.3.6.1.4.1.1271.2.2.3.0.16 |
This notification is sent when the deprov (cold switchover or failover) fails. To enable the device to send this notification: - cienaCesModuleAllModulesTrapState needs to be set to enabled. - cienaCesModuleHATrapState needs to be set to enabled. The above values are set to enabled by default. Variable bindings include: cienaGlobalSeverity, cienaGlobalMacAddress, cienaCesModuleChassisNotifIndx, cienaCesModuleShelfNotifIndx, cienaCesModuleSlotNotifIndx, cienaCesModuleAdminState, and cienaCesModuleOperState. |
||
cienaCesModuleHitlessModeUnsuccessfulNotification | 1.3.6.1.4.1.1271.2.2.3.0.17 |
This notification is sent when the audit (hot failover or switchover) fails. To enable the device to send this notification: - cienaCesModuleAllModulesTrapState needs to be set to enabled. - cienaCesModuleHATrapState needs to be set to enabled. The above values are set to enabled by default. Variable bindings include: cienaGlobalSeverity, cienaGlobalMacAddress, cienaCesModuleChassisNotifIndx, cienaCesModuleShelfNotifIndx, cienaCesModuleSlotNotifIndx, cienaCesModuleAdminState, and cienaCesModuleOperState. |
||
cienaCesModuleSwitchFabricDisruptedUnrecoverableNotification | 1.3.6.1.4.1.1271.2.2.3.0.18 |
This notification is sent when the switch fabric detects a game-over failure and the system cannot automatically correct without resetting certain fabric subsystems. This kind of a disruption can cause a major service interruption. To enable the device to send this notification: - cienaCesModuleAllModulesTrapState needs to be set to enabled - cienaCesModuleSwitchFabricDisruptedTrapState needs to be set to enabled. The above values are set to enabled by default. Variable bindings include: cienaGlobalSeverity, cienaGlobalMacAddress, cienaCesModuleChassisNotifIndx, cienaCesModuleShelfNotifIndx, and cienaCesModuleSlotNotifIndx. |
||
cienaCesModuleSwitchFabricDisruptedRecoverableNotification | 1.3.6.1.4.1.1271.2.2.3.0.19 |
This notification is sent when the switch fabric detects game-over failure and the system can automatically correct it. To enable the device to send this notification: - cienaCesModuleAllModulesTrapState needs to be set to enabled - cienaCesModuleSwitchFabricDisruptedTrapState needs to be set to enabled. The above values are set to enabled by default. Variable bindings include: cienaGlobalSeverity, cienaGlobalMacAddress, cienaCesModuleChassisNotifIndx, cienaCesModuleShelfNotifIndx, and cienaCesModuleSlotNotifIndx. |