CHASSISMGREXT-MIB: View SNMP OID List / Download MIB

VENDOR: ARROWPOINT COMMUNICATIONS INC.


 Home MIB: CHASSISMGREXT-MIB
Download as:   

Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
 chassisMgrExtMib 1.3.6.1.4.1.2467.1.34.1
This MIB module describes the ArrowPoint Communications enterprise MIB for the High Speed Serial Interface (HSSI) module.
 apChassisMgrExtChassisType 1.3.6.1.4.1.2467.1.34.2 integer read-only
This object specifies the type of chassis. Enumeration: 'ws150': 2, 'ws50': 3, 'unknown': 4, 'ws100': 0, 'ws800': 1.
 apChassisMgrExtChassisName 1.3.6.1.4.1.2467.1.34.3 displaystring read-only
This object specifies the name of the chassis.
 apChassisMgrExtChassisSerialNumber 1.3.6.1.4.1.2467.1.34.4 displaystring read-only
This object specifies the serial number of the chassis.
 apChassisMgrExtNumberSlots 1.3.6.1.4.1.2467.1.34.5 integer read-only
This object specifies the number of slots in the chassis.
 apChassisMgrExtNumberModules 1.3.6.1.4.1.2467.1.34.6 integer read-only
This object specifies the number of modules in the chassis.
 apChassisMgrExtNumberPowerSupplies 1.3.6.1.4.1.2467.1.34.7 integer read-only
This object specifies the number of power supplies in the chassis.
 apChassisMgrExtNumberFans 1.3.6.1.4.1.2467.1.34.8 integer read-only
This object specifies the number of fans in the chassis.
 apChassisMgrExtSoftwareVersionNumber 1.3.6.1.4.1.2467.1.34.9 displaystring read-only
This object specifies the version number of the running software in the chassis.
 apChassisMgrExtBootpState 1.3.6.1.4.1.2467.1.34.10 integer read-only
This object specifies the state of the BOOTP services at chassis boot time. Enumeration: 'bootp-enabled': 1, 'bootp-disabled': 0.
 apChassisMgrExtMgmtPortIpAddress 1.3.6.1.4.1.2467.1.34.11 ipaddress read-only
This object specifies the Ip Address of the management port on the chassis.
 apChassisMgrExtBaseEthernetAddress 1.3.6.1.4.1.2467.1.34.12 displaystring read-only
This object specifies the base ethernet address the unit.
 apChassisMgrExtCpuUtilization 1.3.6.1.4.1.2467.1.34.13 integer read-only
This object has been DEPRECATED. Use: apChassisMgrExtSubModuleCPUInstantaneous or apChassisMgrExtSubModuleCPUAverage
 apChassisMgrExtMajorHwVersion 1.3.6.1.4.1.2467.1.34.14 displaystring read-only
This object specifies the major hardware version of the chassis.
 apChassisMgrExtMinorHwVersion 1.3.6.1.4.1.2467.1.34.15 displaystring read-only
This object specifies the minor hardware version of the chassis.
 apChassisMgrExtModuleTable 1.3.6.1.4.1.2467.1.34.16 no-access
The Module Table for a given slot in the chassis.
       apChassisMgrExtModuleEntry 1.3.6.1.4.1.2467.1.34.16.1 no-access
An entry in the Chassis Module Table.
           apChassisMgrExtModuleSlotNumber 1.3.6.1.4.1.2467.1.34.16.1.2 integer read-only
This object specifies slot number of this module within the chassis.
           apChassisMgrExtModuleType 1.3.6.1.4.1.2467.1.34.16.1.3 integer read-only
This object specifies module type within the chassis. Enumeration: 'scm': 0, 'dual-hssi': 4, 'unknown': 9, 'fem': 5, 'scfm': 2, 'sfm': 1, 'gem': 8, 'fem-t1': 3, 'fenic': 6, 'genic': 7.
           apChassisMgrExtModuleName 1.3.6.1.4.1.2467.1.34.16.1.4 displaystring read-only
This object specifies module name within the chassis.
           apChassisMgrExtModuleSerialNumber 1.3.6.1.4.1.2467.1.34.16.1.5 displaystring read-only
This object specifies the serial number of the module within the chassis.
           apChassisMgrExtModuleOpStatus 1.3.6.1.4.1.2467.1.34.16.1.6 integer read-only
This object specifies the module's operational status within the chassis. Enumeration: 'unknown': 5, 'powered-on': 1, 'primary': 2, 'bad': 4, 'powered-off': 0, 'backup': 3.
           apChassisMgrExtModuleNumSubModules 1.3.6.1.4.1.2467.1.34.16.1.7 integer read-only
This object specifies the number of sub-modules on this module within the chassis.
           apChassisMgrExtModuleMajorHwVersion 1.3.6.1.4.1.2467.1.34.16.1.8 displaystring read-only
This object specifies the hardware major version of the module within the chassis.
           apChassisMgrExtModuleMinorHwVersion 1.3.6.1.4.1.2467.1.34.16.1.9 displaystring read-only
This object specifies the minor hardware version of the module within the chassis.
 apChassisMgrExtSubModuleTable 1.3.6.1.4.1.2467.1.34.17 no-access
The table describes sub-module(s) associated with a module in a slot in the chassis.
       apChassisMgrExtSubModuleEntry 1.3.6.1.4.1.2467.1.34.17.1 no-access
An entry in the sub-module table.
           apChassisMgrExtSubModuleSlot 1.3.6.1.4.1.2467.1.34.17.1.1 integer read-only
This object specifies the slot number associated with this sub-module within the chassis.
           apChassisMgrExtSubModuleSubSlot 1.3.6.1.4.1.2467.1.34.17.1.2 integer read-only
This object specifies sub-slot associated with this sub-module within the chassis.
           apChassisMgrExtSubModuleType 1.3.6.1.4.1.2467.1.34.17.1.3 integer read-only
This object specifies the type of sub-module. Enumeration: 'sfm-submodule': 1, 't1-submodule': 3, 'genic-2port-submodule': 10, 'scfm2-submodule': 9, 'genic-1port-submodule': 11, 'v35-submodule': 6, 'sfm2-submodule': 8, 'scm-submodule': 0, 'hssi-submodule': 4, 'epif-submodule': 5, 'scfm-submodule': 2, 'xpif-submodule': 7, 'unknown-submodule': 12.
           apChassisMgrExtSubModuleName 1.3.6.1.4.1.2467.1.34.17.1.4 displaystring read-only
This object specifies the name of the sub-module.
           apChassisMgrExtSubModuleOpStatus 1.3.6.1.4.1.2467.1.34.17.1.5 integer read-only
This object specifies the sub-module's operational status within the chassis. Enumeration: 'offline-bad': 1, 'offline-ok': 0, 'post-bad-comm': 10, 'going-offline': 5, 'any': 11, 'bad': 3, 'post-fail': 9, 'online': 2, 'post-ok': 8, 'going-online': 4, 'unknown-state': 12, 'inserted': 6, 'post': 7.
           apChassisMgrExtSubModuleSsCardType 1.3.6.1.4.1.2467.1.34.17.1.6 integer read-only
This object specifies the type of Special Services card for this sub-module within the chassis. Enumeration: 'hifen-t1': 0, 'hifen-hssi': 1, 'unknown': 2.
           apChassisMgrExtSubModuleSsCardOpStatus 1.3.6.1.4.1.2467.1.34.17.1.7 integer read-only
This object specifies the operational status of the Special Services card for this sub-module within the chassis. Enumeration: 'offline-bad': 1, 'offline-ok': 0, 'unknown-state': 3, 'online': 2.
           apChassisMgrExtSubModulePortName 1.3.6.1.4.1.2467.1.34.17.1.8 displaystring read-only
This object specifies the user visible port name.
           apChassisMgrExtSubModulePortNumber 1.3.6.1.4.1.2467.1.34.17.1.9 integer read-only
This object specifies the external port number of this sub-slot associated with this sub-module within the chassis.
           apChassisMgrExtSubModuleSystemHeapFree 1.3.6.1.4.1.2467.1.34.17.1.10 integer32 read-only
This object identifes the amount of available system heap memory.
           apChassisMgrExtSubModuleSystemHeapChainDepth 1.3.6.1.4.1.2467.1.34.17.1.11 integer32 read-only
This object specifies the chain depth of the system heap.
           apChassisMgrExtSubModuleInstalledMemory 1.3.6.1.4.1.2467.1.34.17.1.12 integer32 read-only
This object specifies the amount of memory present on the submodule.
           apChassisMgrExtSubModuleCPUInstantaneous 1.3.6.1.4.1.2467.1.34.17.1.13 integer32 read-only
This object specifies the instantaneous CPU utilization
           apChassisMgrExtSubModuleCPUAverage 1.3.6.1.4.1.2467.1.34.17.1.14 integer32 read-only
This object specifies the average CPU utilization
 apChassisMgrExtSubModuleBufferTable 1.3.6.1.4.1.2467.1.34.18 no-access
The table describes buffers for sub-module(s) associated with a module in a slot in the chassis.
       apChassisMgrExtSubModuleBufferEntry 1.3.6.1.4.1.2467.1.34.18.1 no-access
An entry in the sub-module buffer table.
           apChassisMgrExtSubModuleBufferPool 1.3.6.1.4.1.2467.1.34.18.1.1 integer read-only
This object specifies buffer pool associated with this sub-module within the chassis.
           apChassisMgrExtSubModuleBufferSlot 1.3.6.1.4.1.2467.1.34.18.1.2 integer read-only
This object specifies the slot number associated with this sub-module within the chassis.
           apChassisMgrExtSubModuleBufferSubSlot 1.3.6.1.4.1.2467.1.34.18.1.3 integer read-only
This object specifies sub-slot associated with this sub-module within the chassis.
           apChassisMgrExtSubModuleBufferSize 1.3.6.1.4.1.2467.1.34.18.1.4 integer32 read-only
This object specifies the buffer pool size.
           apChassisMgrExtSubModuleBufferCount 1.3.6.1.4.1.2467.1.34.18.1.5 integer32 read-only
This object specifies the buffer pool count.
           apChassisMgrExtSubModuleBufferAvailable 1.3.6.1.4.1.2467.1.34.18.1.6 integer32 read-only
This object specifies the number of available buffers in the buffer pool.
           apChassisMgrExtSubModuleBufferFailures 1.3.6.1.4.1.2467.1.34.18.1.7 integer32 read-only
This object specifies the number of buffer pool failures.
           apChassisMgrExtSubModuleBufferLowBufferCount 1.3.6.1.4.1.2467.1.34.18.1.8 integer32 read-only
This object specifies the buffer low threshold count.