Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
       cerentOpticalMonitorMIB 1.3.6.1.4.1.3607.1.10.70
This MIB module defines objects to monitor optical characteristics and set corresponding thresholds, on the optical interfaces in a network element. This module is an adaptation of CISCO-OPTICAL-MONITOR-MIB.
 cerentOpticalMonitorMIBObjects 1.3.6.1.4.1.3607.2.30
       cerentOpticalMonGroup 1.3.6.1.4.1.3607.2.30.1
           cOpticalMonTable 1.3.6.1.4.1.3607.2.30.1.1 no-access
This table provides objects to monitor optical parameters in a network element. It also provides objects for setting high and low threshold levels, with configurable severities, on these monitored parameters.
               cOpticalMonEntry 1.3.6.1.4.1.3607.2.30.1.1.1 no-access
An entry in the cOpticalMonTable provides objects to monitor an optical parameter and set threshold levels on that parameter, at an optical interface. Note that the set of monitored optical parameters may vary based on interface type and direction. Examples of interfaces that can have an entry in this table include optical transceivers optical amplifiers, and optical attenuators.
                   cOpticalMonDirection 1.3.6.1.4.1.3607.2.30.1.1.1.1 opticalifdirection no-access
This object is an index into the cOpticalMonTable and indicates the direction monitored for the optical interface, in this entry.
                   cOpticalMonParameterType 1.3.6.1.4.1.3607.2.30.1.1.1.2 opticalparametertype no-access
This object is an index into the cOpticalMonTable and specifies the optical parameter that is being monitored, in this entry.
                   cOpticalParameterValue 1.3.6.1.4.1.3607.2.30.1.1.1.3 opticalparametervalue read-only
This object gives the value measured for the particular optical parameter specified by the cOpticalMonParameterType object.
                   cOpticalParamHighAlarmThresh 1.3.6.1.4.1.3607.2.30.1.1.1.4 opticalparametervalue read-write
This object is used to set a high alarm threshold on the optical parameter being monitored. If the measured value of the parameter,is greater than the value configured in this object, an alarm will be raised. When the cOpticalMonParameterType object is set to 'power' for the receive direction at a transceiver, this object specifies the receiver saturation level.
                   cOpticalParamHighWarning15MinThresh 1.3.6.1.4.1.3607.2.30.1.1.1.5 opticalparametervalue read-write
This object is used to set a high warning 15 minute threshold on the optical parameter being monitored. If the measured value of the parameter,is greater than the value configured in this object, an alarm may be raised.
                   cOpticalParamHighWarning1DayThresh 1.3.6.1.4.1.3607.2.30.1.1.1.6 opticalparametervalue read-write
This object is used to set a high warning 1 day threshold on the optical parameter being monitored. If the measured value of the parameter,is greater than the value configured in this object, an alarm may be raised.
                   cOpticalParamLowAlarmThresh 1.3.6.1.4.1.3607.2.30.1.1.1.7 opticalparametervalue read-write
This object is used to set a low alarm threshold on the optical parameter being monitored. If the measured value of the parameter,goes lower than the value configured in this object, an alarm will be raised. When the cOpticalMonParameterType object is set to 'power' for the receive direction and when the interface supports alarms based on loss of light, this object specifies the optical power threshold for declaring loss of light. Also, when optical amplifiers are present in the network, in the receive direction, this value may need to be configured, since the noise floor may be higher than the minimum sensitivity of the receiver.
                   cOpticalParamLowWarning15MinThresh 1.3.6.1.4.1.3607.2.30.1.1.1.8 opticalparametervalue read-write
This object is used to set a low warning 15 minute threshold on the optical parameter being monitored. If the measured value of the parameter,goes lower than the value configured in this object, an alarm will be raised.
                   cOpticalParamLowWarning1DayThresh 1.3.6.1.4.1.3607.2.30.1.1.1.9 opticalparametervalue read-write
This object is used to set a low warning 1 day threshold on the optical parameter being monitored. If the measured value of the parameter,goes lower than the value configured in this object, an alarm will be raised.
                   cOpticalParamLowDegradeThresh 1.3.6.1.4.1.3607.2.30.1.1.1.10 opticalparametervalue read-write
This object is used to set a low degrade threshold on the optical parameter being monitored. If the measured value of the parameter,goes lower than the value configured in this object, a degrade alarm will be raised.
                   cOpticalParamHighDegradeThresh 1.3.6.1.4.1.3607.2.30.1.1.1.11 opticalparametervalue read-write
This object is used to set a high degrade threshold on the optical parameter being monitored. If the measured value of the parameter,goes lower than the value configured in this object, a degrade alarm will be raised.
       cerentOpticalPMGroup 1.3.6.1.4.1.3607.2.30.2
           cOpticalPMCurrentTable 1.3.6.1.4.1.3607.2.30.2.1 no-access
This table stores performance monitoring data for the various optical parameters, collected over the current interval.
               cOpticalPMCurrentEntry 1.3.6.1.4.1.3607.2.30.2.1.1 no-access
An entry in the cOpticalPMCurrentTable. It contains performance monitoring data for an optical parameter, collected over the current interval. Note that the set of monitored optical parameters may vary based on interface type and direction. Examples of interfaces that can have an entry in this table include optical transceivers, optical amplifiers, and optical attenuators.
                   cOpticalPMCurrentDirection 1.3.6.1.4.1.3607.2.30.2.1.1.1 opticalifdirection no-access
This object is an index into the cOpticalPMCurrentTable and indicates the direction monitored for the optical interface, in this entry.
                   cOpticalPMCurrentParamType 1.3.6.1.4.1.3607.2.30.2.1.1.2 opticalparametertype no-access
This object is an index into the cOpticalPMCurrentTable and specifies the optical parameter that is being monitored, in this entry.
                   cOpticalPMCurrentPeriod 1.3.6.1.4.1.3607.2.30.2.1.1.3 cerentperiod no-access
This object is an index into the cOpticalPMCurrentTable and indicates whether the optical parameter values given in this entry, are collected over a period of 15 minutes or 24 hours.
                   cOpticalPMCurrentMaxParam 1.3.6.1.4.1.3607.2.30.2.1.1.4 opticalparametervalue read-only
This object gives the maximum value measured for the optical parameter, in the current 15 minute or 24 hour interval.
                   cOpticalPMCurrentMinParam 1.3.6.1.4.1.3607.2.30.2.1.1.5 opticalparametervalue read-only
This object gives the minimum value measured for the optical parameter, in the current 15 minute or 24 hour interval.
                   cOpticalPMCurrentMeanParam 1.3.6.1.4.1.3607.2.30.2.1.1.6 opticalparametervalue read-only
This object gives the average value of the measured optical parameter, in the current 15 minute or 24 hour interval.
           cOpticalPMIntervalTable 1.3.6.1.4.1.3607.2.30.2.2 no-access
This table stores performance monitoring data for the various optical parameters, collected over current and previous intervals. This table can have entries for up to 96 complete 15 minute intervals.
               cOpticalPMIntervalEntry 1.3.6.1.4.1.3607.2.30.2.2.1 no-access
An entry in the cOpticalPMIntervalTable. It contains performance monitoring data for an optical parameter, collected over current and previous intervals. Note that the set of monitored optical parameters may vary based on interface type and direction. Examples of interfaces that can have an entry in this table include optical transceivers, optical amplifiers, and optical attenuators.
                   cOpticalPMIntervalDirection 1.3.6.1.4.1.3607.2.30.2.2.1.1 opticalifdirection no-access
This object is an index into the cOpticalPMIntervalTable and indicates the direction monitored for the optical interface, in this entry.
                   cOpticalPMIntervalParamType 1.3.6.1.4.1.3607.2.30.2.2.1.2 opticalparametertype no-access
This object is an index into the cOpticalPMIntervalTable and specifies the optical parameter that is being monitored, in this entry.
                   cOpticalPMIntervalPeriod 1.3.6.1.4.1.3607.2.30.2.2.1.3 cerentperiod no-access
This object is an index into the cOpticalPMIntervalTable and indicates whether the optical parameter values given in this entry, are collected over a period of 15 minutes or 24 hours.
                   cOpticalPMIntervalNumber 1.3.6.1.4.1.3607.2.30.2.2.1.4 integer32 no-access
This object is an index into the cOpticalPMIntervalTable. It is a number between 1 and 96, which identifies the interval for which the set of optical parameter values is available. The interval identified by 1 is the most recent 15 minute or 24 hour interval, and the interval identified by N is the interval immediately preceding the one identified by N-1.
                   cOpticalPMIntervalMaxParam 1.3.6.1.4.1.3607.2.30.2.2.1.5 opticalparametervalue read-only
This object gives the maximum value measured for the optical parameter, in a particular 15 minute or 24 hour interval.
                   cOpticalPMIntervalMinParam 1.3.6.1.4.1.3607.2.30.2.2.1.6 opticalparametervalue read-only
This object gives the minimum value measured for the optical parameter, in a particular 15 minute or 24 hour interval.
                   cOpticalPMIntervalMeanParam 1.3.6.1.4.1.3607.2.30.2.2.1.7 opticalparametervalue read-only
This object gives the average value of the measured optical parameter, in a particular 15 minute or 24 hour interval.
                   cOpticalPMIntervalValidData 1.3.6.1.4.1.3607.2.30.2.2.1.8 truthvalue read-only
This variable indicates if the data for this interval is valid.
 cerentOpticalMonitorMIBConformance 1.3.6.1.4.1.3607.5.20
       cerentOpticalMonitorMIBCompliances 1.3.6.1.4.1.3607.5.20.1
           cerentOpticalMonitorMIBCompliance 1.3.6.1.4.1.3607.5.20.1.1
The compliance statement for network elements that monitor optical characteristics and set thresholds on the optical interfaces in a network element.
       cerentOpticalMonitorMIBGroups 1.3.6.1.4.1.3607.5.20.2
           cerentOpticalMIBMonGroup 1.3.6.1.4.1.3607.5.20.2.1
A mandatory object that provides monitoring of optical characteristics.
           cerentOpticalMIBThresholdGroup 1.3.6.1.4.1.3607.5.20.2.2
A collection of objects that support thresholds on optical parameters and provide status information when the thresholds are exceeded or cleared.
           cerentOpticalMIBPMGroup 1.3.6.1.4.1.3607.5.20.2.3
A collection of objects that provide optical performance monitoring data for 15 minute and 24 hour intervals.
           cerentOpticalDwdmNetworkMIBThresholdGroup 1.3.6.1.4.1.3607.5.20.2.4
A collection of objects that support thresholds on optical DWDM Network parameters and provide status information when the thresholds are exceeded or cleared.