CERENT-ENVMON-MIB: View SNMP OID List / Download MIB
VENDOR: CERENT CORPORATION
Home | MIB: CERENT-ENVMON-MIB | |||
---|---|---|---|---|
Download as: |
Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
|
|||
Object Name | OID | Type | Access | Info |
cerentEnvMonMIB | 1.3.6.1.4.1.3607.1.10.120 |
This MIB module provides Environmental status information |
||
cerentEnvMonObjects | 1.3.6.1.4.1.3607.2.80 | |||
cerentEnvMonVoltageStatsTable | 1.3.6.1.4.1.3607.2.80.10 | no-access |
This table maintains the status info for all EnvMon related voltages picked up by the sensors in the device. |
|
1.3.6.1.4.1.3607.2.80.10.1 | no-access |
There will as many rows as there are sensors in the device. |
||
cerentEnvMonVoltageStatsIndex | 1.3.6.1.4.1.3607.2.80.10.1.10 | integer32 | no-access |
The value index uniquely indicates the voltage sensor in the device. |
cerentEnvMonVoltageStatsDescr | 1.3.6.1.4.1.3607.2.80.10.1.20 | displaystring | read-only |
Unique Name/Description of the voltage sensor. |
cerentEnvMonVoltageStatsCurrentValue | 1.3.6.1.4.1.3607.2.80.10.1.30 | integer32 | read-only |
Current voltage measurement at this voltage sensor. |
cerentEnvMonVoltageStatsThresholdVeryHigh | 1.3.6.1.4.1.3607.2.80.10.1.40 | integer32 | read-only |
If the current voltage value exceeds this threshold value, an alarm event will be raised by the device. The severity of this event may be provisionable. |
cerentEnvMonVoltageStatsThresholdHigh | 1.3.6.1.4.1.3607.2.80.10.1.50 | integer32 | read-only |
If the current voltage value exceeds this threshold value, a warning event will be raised by the device. The severity of this event may be provisionable. |
cerentEnvMonVoltageStatsThresholdLow | 1.3.6.1.4.1.3607.2.80.10.1.60 | integer32 | read-only |
If the current voltage value falls below this threshold value, a warning event will be raised by the device. The severity of this event may be provisionable. |
cerentEnvMonVoltageStatsThresholdVeryLow | 1.3.6.1.4.1.3607.2.80.10.1.70 | integer32 | read-only |
If the current voltage value falls below this threshold value, an alarm event will be raised by the device. The severity of this event may be provisionable. |
cerentEnvMonTemperatureStatsTable | 1.3.6.1.4.1.3607.2.80.20 | no-access |
This table provides ambient temperature information as measured by the temperature sensors. |
|
1.3.6.1.4.1.3607.2.80.20.1 | no-access |
Each temperature is represented by a row in the table. |
||
cerentEnvMonTemperatureStatsIndex | 1.3.6.1.4.1.3607.2.80.20.1.10 | integer32 | no-access |
The value index uniquely indicates the temperature sensor in the device. |
cerentEnvMonTemperatureStatsDescr | 1.3.6.1.4.1.3607.2.80.20.1.20 | displaystring | read-only |
Unique Name/Description of the temperature sensor. |
cerentEnvMonTemperatureStatsCurrentValue | 1.3.6.1.4.1.3607.2.80.20.1.30 | gauge32 | read-only |
Current Temperature measurement at this temperature sensor. |
cerentEnvMonTemperatureStatsThresholdHigh | 1.3.6.1.4.1.3607.2.80.20.1.40 | gauge32 | read-only |
If the current temperature value exceeds this threshold value, an alarm event will be raised by the device. The severity of this event may be provisionable. |
cerentEnvMonMibConformance | 1.3.6.1.4.1.3607.5.70 |
This node is created for compliance. Has objects as required by the RFCs |
||
cerentEnvMonMibCompliance | 1.3.6.1.4.1.3607.5.70.10 |
The compliance statements for Cisco ONS devices. |
||
cerentEnvMonMibBasicCompliance | 1.3.6.1.4.1.3607.5.70.10.10 |
The basic implementation requirements for all Cisco ONS network devices. |
||
cerentEnvMonMibGroups | 1.3.6.1.4.1.3607.5.70.20 |
All the objects and events are grouped under this for conformance |
||
cerentEnvMonMibObjectsGroup | 1.3.6.1.4.1.3607.5.70.20.10 |
All NMS accessible objects |