Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
 ccpower 1.3.6.1.4.1.18642
             dcSystem 1.3.6.1.4.1.18642.1
                 readWriteObjects 1.3.6.1.4.1.18642.1.1
                     settings 1.3.6.1.4.1.18642.1.1.1
                         floatVoltage 1.3.6.1.4.1.18642.1.1.1.1 integer read-write
Rectifier DC Output Voltage. Return value is XXX representing XX.X volts.
                         overloadCurrent 1.3.6.1.4.1.18642.1.1.1.2 integer read-write
Current which when exceeded will cause an alarm. Return value is XXXX representing XXXX amps.
                         highVoltageAlarm 1.3.6.1.4.1.18642.1.1.1.3 integer read-write
Voltage which when exceeded will cause an alarm. Return value is XXX representing XX.X volts.
                         lowVoltageAlarm 1.3.6.1.4.1.18642.1.1.1.4 integer read-write
Voltage which when exceeded will cause an alarm. Return value is XXX representing XX.X volts.
                         disconnect1Voltage 1.3.6.1.4.1.18642.1.1.1.5 integer read-write
Voltage which when exceeded will cause a specific load to disconnect. Return value is XXX representing XX.X volts.
                         disconnect1Temperature 1.3.6.1.4.1.18642.1.1.1.6 integer read-write
Temperature which when exceeded will cause a specific load to disconnect. Return value is XX representing XX ?C.
                         disconnect1LoadShedSundayOff 1.3.6.1.4.1.18642.1.1.1.7 displaystring read-write
Time on Sunday which when reached will cause a specific load to disconnect. Return value is XX:XX representing HH:MM.
                         disconnect1LoadShedMondayOff 1.3.6.1.4.1.18642.1.1.1.8 displaystring read-write
Time on Monday which when reached will cause a specific load to disconnect. Return value is XX:XX representing HH:MM.
                         disconnect1LoadShedTuesdayOff 1.3.6.1.4.1.18642.1.1.1.9 displaystring read-write
Time on Tuesday which when reached will cause a specific load to disconnect. Return value is XX:XX representing HH:MM.
                         disconnect1LoadShedWednesdayOff 1.3.6.1.4.1.18642.1.1.1.10 displaystring read-write
Time on Wednesday which when reached will cause a specific load to disconnect. Return value is XX:XX representing HH:MM.
                         disconnect1LoadShedThursdayOff 1.3.6.1.4.1.18642.1.1.1.11 displaystring read-write
Time on Thursday which when reached will cause a specific load to disconnect. Return value is XX:XX representing HH:MM.
                         disconnect1LoadShedFridayOff 1.3.6.1.4.1.18642.1.1.1.12 displaystring read-write
Time on Friday which when reached will cause a specific load to disconnect. Return value is XX:XX representing HH:MM.
                         disconnect1LoadShedSaturdayOff 1.3.6.1.4.1.18642.1.1.1.13 displaystring read-write
Time on Saturday which when reached will cause a specific load to disconnect. Return value is XX:XX representing HH:MM.
                         disconnect2Voltage 1.3.6.1.4.1.18642.1.1.1.14 integer read-write
Voltage which when exceeded will cause a specific load to disconnect. Return value is XXX representing XX.X volts.
                         disconnect2Temperature 1.3.6.1.4.1.18642.1.1.1.15 integer read-write
Temperature which when exceeded will cause a specific load to disconnect. Return value is XX representing XX ?C.
                         disconnect2LoadShedSundayOff 1.3.6.1.4.1.18642.1.1.1.16 displaystring read-write
Time on Sunday which when reached will cause a specific load to disconnect. Return value is XX:XX representing HH:MM.
                         disconnect2LoadShedMondayOff 1.3.6.1.4.1.18642.1.1.1.17 displaystring read-write
Time on Monday which when reached will cause a specific load to disconnect. Return value is XX:XX representing HH:MM.
                         disconnect2LoadShedTuesdayOff 1.3.6.1.4.1.18642.1.1.1.18 displaystring read-write
Time on Tuesday which when reached will cause a specific load to disconnect. Return value is XX:XX representing HH:MM.
                         disconnect2LoadShedWednesdayOff 1.3.6.1.4.1.18642.1.1.1.19 displaystring read-write
Time on Wednesday which when reached will cause a specific load to disconnect. Return value is XX:XX representing HH:MM.
                         disconnect2LoadShedThursdayOff 1.3.6.1.4.1.18642.1.1.1.20 displaystring read-write
Time on Thursday which when reached will cause a specific load to disconnect. Return value is XX:XX representing HH:MM.
                         disconnect2LoadShedFridayOff 1.3.6.1.4.1.18642.1.1.1.21 displaystring read-write
Time on Friday which when reached will cause a specific load to disconnect. Return value is XX:XX representing HH:MM.
                         disconnect2LoadShedSaturdayOff 1.3.6.1.4.1.18642.1.1.1.22 displaystring read-write
Time on Saturday which when reached will cause a specific load to disconnect. Return value is XX:XX representing HH:MM.
                         disconnect3Voltage 1.3.6.1.4.1.18642.1.1.1.23 integer read-write
Voltage which when exceeded will cause a specific load to disconnect. Return value is XXX representing XX.X volts.
                         disconnect3Temperature 1.3.6.1.4.1.18642.1.1.1.24 integer read-write
Temperature which when exceeded will cause a specific load to disconnect. Return value is XX representing XX ?C.
                         disconnect3LoadShedSundayOff 1.3.6.1.4.1.18642.1.1.1.25 displaystring read-write
Time on Sunday which when reached will cause a specific load to disconnect. Return value is XX:XX representing HH:MM.
                         disconnect3LoadShedMondayOff 1.3.6.1.4.1.18642.1.1.1.26 displaystring read-write
Time on Monday which when reached will cause a specific load to disconnect. Return value is XX:XX representing HH:MM.
                         disconnect3LoadShedTuesdayOff 1.3.6.1.4.1.18642.1.1.1.27 displaystring read-write
Time on Tuesday which when reached will cause a specific load to disconnect. Return value is XX:XX representing HH:MM.
                         disconnect3LoadShedWednesdayOff 1.3.6.1.4.1.18642.1.1.1.28 displaystring read-write
Time on Wednesday which when reached will cause a specific load to disconnect. Return value is XX:XX representing HH:MM.
                         disconnect3LoadShedThursdayOff 1.3.6.1.4.1.18642.1.1.1.29 displaystring read-write
Time on Thursday which when reached will cause a specific load to disconnect. Return value is XX:XX representing HH:MM.
                         disconnect3LoadShedFridayOff 1.3.6.1.4.1.18642.1.1.1.30 displaystring read-write
Time on Friday which when reached will cause a specific load to disconnect. Return value is XX:XX representing HH:MM.
                         disconnect3LoadShedSaturdayOff 1.3.6.1.4.1.18642.1.1.1.31 displaystring read-write
Time on Saturday which when reached will cause a specific load to disconnect. Return value is XX:XX representing HH:MM.
                         reconnect1Voltage 1.3.6.1.4.1.18642.1.1.1.32 integer read-write
Voltage which when reached will cause a specific load to reconnect. Return value is XXX representing XX.X volts.
                         reconnect1LoadShedSundayOn 1.3.6.1.4.1.18642.1.1.1.33 displaystring read-write
Time which when reached will cause a specific load to reconnect. Return value is XX:XX representing HH:MM.
                         reconnect1LoadShedMondayOn 1.3.6.1.4.1.18642.1.1.1.34 displaystring read-write
Time on Monday which when reached will cause a specific load to reconnect. Return value is XX:XX representing HH:MM.
                         reconnect1LoadShedTuesdayOn 1.3.6.1.4.1.18642.1.1.1.35 displaystring read-write
Time on Tuesday which when reached will cause a specific load to reconnect. Return value is XX:XX representing HH:MM.
                         reconnect1LoadShedWednesdayOn 1.3.6.1.4.1.18642.1.1.1.36 displaystring read-write
Time on Wednesday which when reached will cause a specific load to reconnect. Return value is XX:XX representing HH:MM.
                         reconnect1LoadShedThursdayOn 1.3.6.1.4.1.18642.1.1.1.37 displaystring read-write
Time on Thursday which when reached will cause a specific load to reconnect. Return value is XX:XX representing HH:MM.
                         reconnect1LoadShedFridayOn 1.3.6.1.4.1.18642.1.1.1.38 displaystring read-write
Time on Friday which when reached will cause a specific load to reconnect. Return value is XX:XX representing HH:MM.
                         reconnect1LoadShedSaturdayOn 1.3.6.1.4.1.18642.1.1.1.39 displaystring read-write
Time on Saturday which when reached will cause a specific load to reconnect. Return value is XX:XX representing HH:MM.
                         reconnect2Voltage 1.3.6.1.4.1.18642.1.1.1.40 integer read-write
Voltage which when reached will cause a specific load to reconnect. Return value is XXX representing XX.X volts.
                         reconnect2LoadShedSundayOn 1.3.6.1.4.1.18642.1.1.1.41 displaystring read-write
Time on Sunday which when reached will cause a specific load to reconnect. Return value is XX:XX representing HH:MM.
                         reconnect2LoadShedMondayOn 1.3.6.1.4.1.18642.1.1.1.42 displaystring read-write
Time on Monday which when reached will cause a specific load to reconnect. Return value is XX:XX representing HH:MM.
                         reconnect2LoadShedTuesdayOn 1.3.6.1.4.1.18642.1.1.1.43 displaystring read-write
Time on Tuesday which when reached will cause a specific load to reconnect. Return value is XX:XX representing HH:MM.
                         reconnect2LoadShedWednesdayOn 1.3.6.1.4.1.18642.1.1.1.44 displaystring read-write
Time on Wednesday which when reached will cause a specific load to reconnect. Return value is XX:XX representing HH:MM.
                         reconnect2LoadShedThursdayOn 1.3.6.1.4.1.18642.1.1.1.45 displaystring read-write
Time on Thursday which when reached will cause a specific load to reconnect. Return value is XX:XX representing HH:MM.
                         reconnect2LoadShedFridayOn 1.3.6.1.4.1.18642.1.1.1.46 displaystring read-write
Time on Friday which when reached will cause a specific load to reconnect. Return value is XX:XX representing HH:MM.
                         reconnect2LoadShedSaturdayOn 1.3.6.1.4.1.18642.1.1.1.47 displaystring read-write
Time on Saturday which when reached will cause a specific load to reconnect. Return value is XX:XX representing HH:MM.
                         reconnect3Voltage 1.3.6.1.4.1.18642.1.1.1.48 integer read-write
Voltage which when reached will cause a specific load to reconnect. Return value is XXX representing XX.X volts.
                         reconnect3LoadShedSundayOn 1.3.6.1.4.1.18642.1.1.1.49 displaystring read-write
Time on Sunday which when reached will cause a specific load to reconnect. Return value is XX:XX representing HH:MM.
                         reconnect3LoadShedMondayOn 1.3.6.1.4.1.18642.1.1.1.50 displaystring read-write
Time on Monday which when reached will cause a specific load to reconnect. Return value is XX:XX representing HH:MM.
                         reconnect3LoadShedTuesdayOn 1.3.6.1.4.1.18642.1.1.1.51 displaystring read-write
Time on Tuesday which when reached will cause a specific load to reconnect. Return value is XX:XX representing HH:MM.
                         reconnect3LoadShedWednesdayOn 1.3.6.1.4.1.18642.1.1.1.52 displaystring read-write
Time on Wednesday which when reached will cause a specific load to reconnect. Return value is XX:XX representing HH:MM.
                         reconnect3LoadShedThursdayOn 1.3.6.1.4.1.18642.1.1.1.53 displaystring read-write
Time on Thursday which when reached will cause a specific load to reconnect. Return value is XX:XX representing HH:MM.
                         reconnect3LoadShedFridayOn 1.3.6.1.4.1.18642.1.1.1.54 displaystring read-write
Time on Friday which when reached will cause a specific load to reconnect. Return value is XX:XX representing HH:MM.
                         reconnect3LoadShedSaturdayOn 1.3.6.1.4.1.18642.1.1.1.55 displaystring read-write
Time on Saturday which when reached will cause a specific load to reconnect. Return value is XX:XX representing HH:MM.
                         equalizeTime 1.3.6.1.4.1.18642.1.1.1.56 integer read-write
Number of hours the equalize voltage is to be applied. Return value is XXX representing XX.X hours.
                         equalizeVoltage 1.3.6.1.4.1.18642.1.1.1.57 integer read-write
Equalize voltage to be applied. Return value is XXX representing XX.X volts.
                         batteryResistancePercentChange 1.3.6.1.4.1.18642.1.1.1.58 integer read-write
Resistance percentange change that when reached will cause an alarm. Return value is XXX representing XXX %.
                         batteryResistanceTestInterval 1.3.6.1.4.1.18642.1.1.1.59 integer read-write
Battery resistance test interval. Return value is XX representing XX weeks.
                         loadShedTimeControl 1.3.6.1.4.1.18642.1.1.1.60 integer read-write
Load shed time control enabled/disabled status. Return value: 1 = time control enabled, 2 = time control disabled. Enumeration: 'disabled': 2, 'enabled': 1.
                         batteryFloatCurrent 1.3.6.1.4.1.18642.1.1.1.61 integer read-write
Battery float current. Return value is XXX representing XXX amps.
                 readOnlyObjects 1.3.6.1.4.1.18642.1.2
                     rectifiers 1.3.6.1.4.1.18642.1.2.1
                         rectifierFloatVoltage 1.3.6.1.4.1.18642.1.2.1.1 integer read-only
Rectifier float voltage. Return value is XXX representing XX.X volts. Valid ranges are 24.0 to 57.0 volts.
                         rectifierLoadCurrent 1.3.6.1.4.1.18642.1.2.1.2 integer read-only
Rectifier DC load current. Return value is XXXX representing XXXX amps. Valid ranges are 0000 to 5000 amps.
                     batteries 1.3.6.1.4.1.18642.1.2.2
                         batteryCurrent 1.3.6.1.4.1.18642.1.2.2.1 integer read-only
Battery current. Return value is XXXX representing XXXX amps. Valid ranges are 0000 to 1000 amps.
                         batteryTemperature 1.3.6.1.4.1.18642.1.2.2.2 integer read-only
Battery temperature. Return value is XX representing XX ?C. Valid ranges are -40 to 99 ?C.
                         batteryResistanceReference 1.3.6.1.4.1.18642.1.2.2.3 integer read-only
Initial battery resistance. Return value is XXXXX representing X.XXXX ohms. Valid ranges are 0.0000 to 5.0000 ohms.
                         batteryResistanceReading 1.3.6.1.4.1.18642.1.2.2.4 integer read-only
Last battery resistance reading. Return value is XXXXX representing X.XXXX ohms. Valid ranges are 0.0000 to 5.0000 ohms.
                         batteryResistanceChange 1.3.6.1.4.1.18642.1.2.2.5 integer read-only
Percent change from last battery resistance reading. Return value is XXX representing XXX %. Valid ranges are 001 to 999 %.
                         batteryCycles1 1.3.6.1.4.1.18642.1.2.2.6 integer read-only
Number of discharge/recharge cycles less than 1 minute. Return value is XXX representing XXX cycles. Valid ranges are 000 to 255 cycles.
                         batteryCycles1to5 1.3.6.1.4.1.18642.1.2.2.7 integer read-only
Number of discharge/recharge cycles from 1 to 5 minutes. Return value is XXX representing XXX cycles. Valid ranges are 000 to 255 cycles.
                         batteryCycles5to15 1.3.6.1.4.1.18642.1.2.2.8 integer read-only
Number of discharge/recharge cycles from 5 to 15 minutes. Return value is XXX representing XXX cycles. Valid ranges are 000 to 255 cycles.
                         batteryCycles15 1.3.6.1.4.1.18642.1.2.2.9 integer read-only
Number of discharge/recharge cycles greater than 15 minutes. Return value is XXX representing XXX cycles. Valid ranges are 000 to 255 cycles.
                         batteryCycles15LastCycleDate 1.3.6.1.4.1.18642.1.2.2.10 displaystring read-only
Last cycle date of batteryCycles15. Return value is MM-DD-YY, HH-MM.
                         batteryCycles15LastDuration 1.3.6.1.4.1.18642.1.2.2.11 integer read-only
Duration of batteryCycles15 last cycle. Return value is XXXX representing XXXX minutes.
                         batteryTestFault 1.3.6.1.4.1.18642.1.2.2.12 integer read-only
Battery failure has occured during battery restistance test. Return value: 1 = Abort 1, 2 = Abort 2, 3 = Abort 3, 4 = None. Enumeration: 'none': 4, 'abort1': 1, 'abort2': 2, 'abort3': 3.
                     factorySettings 1.3.6.1.4.1.18642.1.2.3
                         floatVoltagePresets 1.3.6.1.4.1.18642.1.2.3.1 displaystring read-only
Float voltage factory setting range. Return value is XX.X volts min, XX.X volts max.
                         highVoltageAlarmPresets 1.3.6.1.4.1.18642.1.2.3.2 displaystring read-only
High voltage alarm factory setting range. Return value is XX.X volts min, XX.X volts max.
                         lowVoltageAlarmPresets 1.3.6.1.4.1.18642.1.2.3.3 displaystring read-only
Low voltage alarm factory setting range. Return value is XX.X volts min, XX.X volts max.
                         disconnect1VoltagePresets 1.3.6.1.4.1.18642.1.2.3.4 displaystring read-only
Disconnect voltage 1 factory setting range. Return value is XX.X volts min, XX.X volts max.
                         disconnect1TemperaturePreset 1.3.6.1.4.1.18642.1.2.3.5 displaystring read-only
Disconnect temperature 1 factory setting. Return value is XX ?C.
                         disconnect1LoadShedSundayPresets 1.3.6.1.4.1.18642.1.2.3.6 displaystring read-only
Disconnect 1 load shed Sunday time settings. Return value is XX:Xx off, XX:XX on.
                         disconnect1LoadShedMondayPresets 1.3.6.1.4.1.18642.1.2.3.7 displaystring read-only
Disconnect 1 load shed Monday time settings. Return value is XX:Xx off, XX:XX on.
                         disconnect1LoadShedTuesdayPresets 1.3.6.1.4.1.18642.1.2.3.8 displaystring read-only
Disconnect 1 load shed Tuesday time settings. Return value is XX:Xx off, XX:XX on.
                         disconnect1LoadShedWednesdayPresets 1.3.6.1.4.1.18642.1.2.3.9 displaystring read-only
Disconnect 1 load shed Wednesday time settings. Return value is XX:Xx off, XX:XX on.
                         disconnect1LoadShedThursdayPresets 1.3.6.1.4.1.18642.1.2.3.10 displaystring read-only
Disconnect 1 load shed Thursday time settings. Return value is XX:Xx off, XX:XX on.
                         disconnect1LoadShedFridayPresets 1.3.6.1.4.1.18642.1.2.3.11 displaystring read-only
Disconnect 1 load shed Friday time settings. Return value is XX:Xx off, XX:XX on.
                         disconnect1LoadShedSaturdayPresets 1.3.6.1.4.1.18642.1.2.3.12 displaystring read-only
Disconnect 1 load shed Saturday time settings. Return value is XX:Xx off, XX:XX on.
                         reconnectVoltage1Presets 1.3.6.1.4.1.18642.1.2.3.13 displaystring read-only
Reconnect voltage 1 factory setting range. Return value is XX.X volts min, XX.X volts max.
                         disconnect2VoltagePresets 1.3.6.1.4.1.18642.1.2.3.14 displaystring read-only
Disconnect voltage 2 factory setting range. Return value is XX.X volts min, XX.X volts max.
                         disconnect2TemperaturePreset 1.3.6.1.4.1.18642.1.2.3.15 displaystring read-only
Disconnect temperature 2 factory setting. Return value is XX ?C.
                         disconnect2LoadShedSundayPresets 1.3.6.1.4.1.18642.1.2.3.16 displaystring read-only
Disconnect 2 load shed Sunday time settings. Return value is XX:Xx off, XX:XX on.
                         disconnect2LoadShedMondayPresets 1.3.6.1.4.1.18642.1.2.3.17 displaystring read-only
Disconnect 2 load shed Monday time settings. Return value is XX:Xx off, XX:XX on.
                         disconnect2LoadShedTuesdayPresets 1.3.6.1.4.1.18642.1.2.3.18 displaystring read-only
Disconnect 2 load shed Tuesday time settings. Return value is XX:Xx off, XX:XX on.
                         disconnect2LoadShedWednesdayPresets 1.3.6.1.4.1.18642.1.2.3.19 displaystring read-only
Disconnect 2 load shed Wednesday time settings. Return value is XX:Xx off, XX:XX on.
                         disconnect2LoadShedThursdayPresets 1.3.6.1.4.1.18642.1.2.3.20 displaystring read-only
Disconnect 2 load shed Thursday time settings. Return value is XX:Xx off, XX:XX on.
                         disconnect2LoadShedFridayPresets 1.3.6.1.4.1.18642.1.2.3.21 displaystring read-only
Disconnect 2 load shed Friday time settings. Return value is XX:Xx off, XX:XX on.
                         disconnect2LoadShedSaturdayPresets 1.3.6.1.4.1.18642.1.2.3.22 displaystring read-only
Disconnect 2 load shed Saturday time settings. Return value is XX:Xx off, XX:XX on.
                         reconnect2VoltagePresets 1.3.6.1.4.1.18642.1.2.3.23 displaystring read-only
Reconnect voltage 2 factory setting range. Return value is XX.X volts min, XX.X volts max.
                         disconnect3VoltagePresets 1.3.6.1.4.1.18642.1.2.3.24 displaystring read-only
Disconnect voltage 3 factory setting range. Return value is XX.X volts min, XX.X volts max.
                         disconnect3TemperaturePreset 1.3.6.1.4.1.18642.1.2.3.25 displaystring read-only
Disconnect temperature 3 factory setting. Return value is XX ?C.
                         disconnect3LoadShedSundayPresets 1.3.6.1.4.1.18642.1.2.3.26 displaystring read-only
Disconnect 3 load shed Sunday time settings. Return value is XX:Xx off, XX:XX on.
                         disconnect3LoadShedMondayPresets 1.3.6.1.4.1.18642.1.2.3.27 displaystring read-only
Disconnect 3 load shed Monday time settings. Return value is XX:Xx off, XX:XX on.
                         disconnect3LoadShedTuesdayPresets 1.3.6.1.4.1.18642.1.2.3.28 displaystring read-only
Disconnect 3 load shed Tuesday time settings. Return value is XX:Xx off, XX:XX on.
                         disconnect3LoadShedWednesdayPresets 1.3.6.1.4.1.18642.1.2.3.29 displaystring read-only
Disconnect 3 load shed Wednesday time settings. Return value is XX:Xx off, XX:XX on.
                         disconnect3LoadShedThursdayPresets 1.3.6.1.4.1.18642.1.2.3.30 displaystring read-only
Disconnect 3 load shed Thursday time settings. Return value is XX:Xx off, XX:XX on.
                         disconnect3LoadShedFridayPresets 1.3.6.1.4.1.18642.1.2.3.31 displaystring read-only
Disconnect 3 load shed Friday time settings. Return value is XX:Xx off, XX:XX on.
                         disconnect3LoadShedSaturdayPresets 1.3.6.1.4.1.18642.1.2.3.32 displaystring read-only
Disconnect 3 load shed Saturday time settings. Return value is XX:Xx off, XX:XX on.
                         reconnect3VoltagePresets 1.3.6.1.4.1.18642.1.2.3.33 displaystring read-only
Reconnect voltage 3 factory setting range. Return value is XX.X volts min, XX.X volts max.
                         overloadCurrentPresets 1.3.6.1.4.1.18642.1.2.3.34 displaystring read-only
Overload current factory setting range. Return value is XXXX amps min, XXXX amps max.
                         maximumCurrentPreset 1.3.6.1.4.1.18642.1.2.3.35 displaystring read-only
Maximum current factory setting. Return value is XXXX amps.
                         batteryFloatCurrentPresets 1.3.6.1.4.1.18642.1.2.3.36 displaystring read-only
Battery float current factory settings. Return value is XXX amps min, XXX amps max.
                         equalizeTimePresets 1.3.6.1.4.1.18642.1.2.3.37 displaystring read-only
Equalize time factory setting range. Return value is 00.0 hours min, XX.X hours max.
                         equalizeVoltagePresets 1.3.6.1.4.1.18642.1.2.3.38 displaystring read-only
Equalize voltage factory setting range. Return value is XX.X volts min, XX.X volts max.
                         batteryResistancePresets 1.3.6.1.4.1.18642.1.2.3.39 displaystring read-only
Battery resistance percent change factory setting range. Return value is XXX % min, XXX % max.
                         batteryTestIntervalPresets 1.3.6.1.4.1.18642.1.2.3.40 displaystring read-only
Battery resistance test interval factory setting range. Return value is XX weeks min, XX weeks max.
                     alarmStatus 1.3.6.1.4.1.18642.1.2.4
                         highVoltageAlarmStatus 1.3.6.1.4.1.18642.1.2.4.1 integer read-only
High voltage alarm status. Return value 1 = alarm inactive, 2 = alarm active. Enumeration: 'active': 2, 'inactive': 1.
                         lowVoltageAlarmStatus 1.3.6.1.4.1.18642.1.2.4.2 integer read-only
Low voltage alarm status. Return value 1 = alarm inactive, 2 = alarm active. Enumeration: 'active': 2, 'inactive': 1.
                         overloadAlarmStatus 1.3.6.1.4.1.18642.1.2.4.3 integer read-only
Overload alarm status. Return value 1 = alarm inactive, 2 = alarm active. Enumeration: 'active': 2, 'inactive': 1.
                         breakerAlarmStatus 1.3.6.1.4.1.18642.1.2.4.4 integer read-only
Breaker alarm status. Return value 1 = alarm inactive, 2 = alarm active. Enumeration: 'active': 2, 'inactive': 1.
                         acFailureAlarmStatus 1.3.6.1.4.1.18642.1.2.4.5 integer read-only
AC failure alarm status. Return value 1 = alarm inactive, 2 = alarm active. Enumeration: 'active': 2, 'inactive': 1.
                         fanFailureAlarmStatus 1.3.6.1.4.1.18642.1.2.4.6 integer read-only
Fan failure alarm status. Return value 1 = alarm inactive, 2 = alarm active. Enumeration: 'active': 2, 'inactive': 1.
                         rectifierFailureAlarmStatus 1.3.6.1.4.1.18642.1.2.4.7 integer read-only
Rectifier failure alarm status. Return value 1 = alarm inactive, 2 = alarm active. Enumeration: 'active': 2, 'inactive': 1.
                         majorAlarmStatus 1.3.6.1.4.1.18642.1.2.4.8 integer read-only
Major alarm status. Return value 1 = alarm inactive, 2 = alarm active. Enumeration: 'active': 2, 'inactive': 1.
                         lowVoltageDisconnect1TemperatureAlarmStatus 1.3.6.1.4.1.18642.1.2.4.9 integer read-only
Low voltage disconnect 1 high temperature alarm status. Return value 1 = alarm inactive, 2 = alarm active. Enumeration: 'active': 2, 'inactive': 1.
                         lowVoltageDisconnect2TemperatureAlarmStatus 1.3.6.1.4.1.18642.1.2.4.10 integer read-only
Low voltage disconnect 2 high temperature alarm status. Return value 1 = alarm inactive, 2 = alarm active. Enumeration: 'active': 2, 'inactive': 1.
                         lowVoltageDisconnect3TemperatureAlarmStatus 1.3.6.1.4.1.18642.1.2.4.11 integer read-only
Low voltage disconnect 3 high temperature alarm status. Return value 1 = alarm inactive, 2 = alarm active. Enumeration: 'active': 2, 'inactive': 1.
                         lowVoltageDisconnect1VoltageAlarmStatus 1.3.6.1.4.1.18642.1.2.4.12 integer read-only
Low voltage disconnect 1 low voltage alarm status. Return value 1 = alarm inactive, 2 = alarm active. Enumeration: 'active': 2, 'inactive': 1.
                         lowVoltageDisconnect2VoltageAlarmStatus 1.3.6.1.4.1.18642.1.2.4.13 integer read-only
Low voltage disconnect 2 low voltage alarm status. Return value 1 = alarm inactive, 2 = alarm active. Enumeration: 'active': 2, 'inactive': 1.
                         lowVoltageDisconnect3VoltageAlarmStatus 1.3.6.1.4.1.18642.1.2.4.14 integer read-only
Low voltage disconnect 3 low voltage alarm status. Return value 1 = alarm inactive, 2 = alarm active. Enumeration: 'active': 2, 'inactive': 1.
                         batteryResistanceAlarmStatus 1.3.6.1.4.1.18642.1.2.4.15 integer read-only
Battery resistance alarm status. Return value 1 = alarm inactive, 2 = alarm active. Enumeration: 'active': 2, 'inactive': 1.
                         batteryCurrentAlarmStatus 1.3.6.1.4.1.18642.1.2.4.16 integer read-only
Battery resistance alarm status. Return value 1 = alarm inactive, 2 = alarm active. Enumeration: 'active': 2, 'inactive': 1.
                         batteryTestAbortCondition1AlarmStatus 1.3.6.1.4.1.18642.1.2.4.17 integer read-only
Battery test abort condition 1 alarm status. Return value 1 = alarm inactive, 2 = alarm active. Enumeration: 'active': 2, 'inactive': 1.
                         batteryTestAbortCondition2AlarmStatus 1.3.6.1.4.1.18642.1.2.4.18 integer read-only
Battery test abort condition 2 alarm status. Return value 1 = alarm inactive, 2 = alarm active. Enumeration: 'active': 2, 'inactive': 1.
                         batteryTestAbortCondition3AlarmStatus 1.3.6.1.4.1.18642.1.2.4.19 integer read-only
Battery test abort condition 3 alarm status. Return value 1 = alarm inactive, 2 = alarm active. Enumeration: 'active': 2, 'inactive': 1.
                         batteryDisconnectAlarmStatus 1.3.6.1.4.1.18642.1.2.4.20 integer read-only
Battery disconnect alarm status. Return value 1 = alarm inactive, 2 = alarm active. Enumeration: 'active': 2, 'inactive': 1.
                         fuseAlarmStatus 1.3.6.1.4.1.18642.1.2.4.21 integer read-only
Fuse alarm status. Return value 1 = alarm inactive, 2 = alarm active. Enumeration: 'active': 2, 'inactive': 1.
                     digitalSensorAlarms 1.3.6.1.4.1.18642.1.2.5
                     systemAlarms 1.3.6.1.4.1.18642.1.2.6
                     digitalSensorAlarmClears 1.3.6.1.4.1.18642.1.2.7
                     systemAlarmClears 1.3.6.1.4.1.18642.1.2.8
               breakerTrap 1.3.6.1.4.1.186420.0
Breaker has tripped.
               fuseTrap 1.3.6.1.4.1.186420.1
Fuse has opened.
               batteryDisconnectTrap 1.3.6.1.4.1.186420.2
Battery disconnect has operated.
               programmableTrap 1.3.6.1.4.1.186420.3
Programmable alarm has occurred.
               highVoltageTrap 1.3.6.1.4.1.186420.4
Float voltage has exceeded preset value. Return value: High voltage alarm XX.X volts.
               lowVoltageTrap 1.3.6.1.4.1.186420.5
Float voltage is below preset value. Return value: Low voltage alarm XX.X volts.
               loadOverCurrentTrap 1.3.6.1.4.1.186420.6
Load current has exceeded preset value. Return value: Load over current alarm XXXX amps.
               batteryFloatCurrentTrap 1.3.6.1.4.1.186420.7
Battery float current has exceeded preset value. Return value: Battery float current alarm XXXX amps.
               loadDisconnect1VoltageTrap 1.3.6.1.4.1.186420.8
Load disconnect 1 voltage has dropped below preset value. Return value: Load disconnect 1 voltage XX.X volts.
               loadDisconnect2VoltageTrap 1.3.6.1.4.1.186420.9
Load disconnect 2 voltage has dropped below preset value. Return value: Load disconnect 2 voltage XX.X volts.
               loadDisconnect3VoltageTrap 1.3.6.1.4.1.186420.10
Load disconnect 3 voltage has dropped below preset value. Return value: Load disconnect 3 voltage XX.X volts.
               loadDisconnect1TemperatureTrap 1.3.6.1.4.1.186420.11
Load disconnect 1 temperature has exceeded preset value. Return value: Load disconnect 1 temperature alarm XX ?C.
               loadDisconnect2TemperatureTrap 1.3.6.1.4.1.186420.12
Load disconnect 2 temperature has exceeded preset value. Return value: Load disconnect 2 temperature alarm XX ?C.
               loadDisconnect3TemperatureTrap 1.3.6.1.4.1.186420.13
Load disconnect 3 temperature has exceeded preset value. Return value: Load disconnect 3 temperature alarm XX ?C.
               rectifierFailureTrap 1.3.6.1.4.1.186420.14
Rectifier failure. Return value: Rectifier failure.
               fanFailureTrap 1.3.6.1.4.1.186420.15
Rectifier fan has failed. Return value: Fan failure.
               acFailureTrap 1.3.6.1.4.1.186420.16
Rectifier has lost AC input power. Return value: AC failure.
               majorFailureTrap 1.3.6.1.4.1.186420.17
Multiple failures of AC, rectififers, fans or a programmed alarm. Return value: Multiple AC, fan, rectifier or optional alarm failures has occurred.
               batteryResistanceTrap 1.3.6.1.4.1.186420.18
Battery resistance has increased by a programmed percentage. Return value: Battery resistance alarm X.XXXX ohms, XXX %.
               batteryTestAbort1Trap 1.3.6.1.4.1.186420.19
Battery failure abort 1 has occured during battery resistance test. Return value: Battery test failure: Abort 1.
               batteryTestAbort2Trap 1.3.6.1.4.1.186420.20
Battery failure abort 2 has occured during battery resistance test. Return value: Battery test failure: Abort 2.
               batteryTestAbort3Trap 1.3.6.1.4.1.186420.21
Battery failure abort 3 has occured during battery resistance test. Return value: Battery test failure: Abort 3.
               breakerTrapClear 1.3.6.1.4.1.186420.100
Breaker alarm has been cleared.
               fuseTrapClear 1.3.6.1.4.1.186420.101
Fuse alarm has been cleared.
               batteryDisconnectTrapClear 1.3.6.1.4.1.186420.102
Battery disconnect alarm has been cleared.
               programmableTrapClear 1.3.6.1.4.1.186420.103
Programmable alarm has been cleared.
               highVoltageTrapClear 1.3.6.1.4.1.186420.104
High voltage alarm has been cleared.
               lowVoltageTrapClear 1.3.6.1.4.1.186420.105
Low voltage alarm has been cleared.
               loadOverCurrentTrapClear 1.3.6.1.4.1.186420.106
Load over current alarm has been cleared.
               batteryFloatCurrentTrapClear 1.3.6.1.4.1.186420.107
Battery float current alarm has been cleared.
               loadDisconnect1VoltageTrapClear 1.3.6.1.4.1.186420.108
Load disconnect 1 voltage alarm has been cleared.
               loadDisconnect2VoltageTrapClear 1.3.6.1.4.1.186420.109
Load disconnect 2 voltage alarm has been cleared.
               loadDisconnect3VoltageTrapClear 1.3.6.1.4.1.186420.110
Load disconnect 3 voltage alarm has been cleared.
               loadDisconnect1TemperatureTrapClear 1.3.6.1.4.1.186420.111
Load disconnect 1 temperature alarm has been cleared.
               loadDisconnect2TemperatureTrapClear 1.3.6.1.4.1.186420.112
Load disconnect 2 temperature alarm has been cleared.
               loadDisconnect3TemperatureTrapClear 1.3.6.1.4.1.186420.113
Load disconnect 3 temperature alarm has been cleared.
               rectifierFailureTrapClear 1.3.6.1.4.1.186420.114
Rectififer failure alarm has been cleared.
               fanFailureTrapClear 1.3.6.1.4.1.186420.115
Fan failure alarm has been cleared.
               acFailureTrapClear 1.3.6.1.4.1.186420.116
AC failure alarm been cleared.
               majorFailureTrapClear 1.3.6.1.4.1.186420.117
Major failure alarm has been cleared.
               batteryResistanceTrapClear 1.3.6.1.4.1.186420.118
Battery resistance alarm has been cleared.
               batteryTestAbort1TrapClear 1.3.6.1.4.1.186420.119
Battery test abort 1 alarm has been cleared.
               batteryTestAbort2TrapClear 1.3.6.1.4.1.186420.120
Battery test abort 2 alarm has been cleared.
               batteryTestAbort3TrapClear 1.3.6.1.4.1.186420.121
Battery test abort 3 alarm has been cleared.