CADANT-CMTS-NOTIFICATION-MIB: View SNMP OID List / Download MIB

VENDOR: CADANT INC.


 Home MIB: CADANT-CMTS-NOTIFICATION-MIB
Download as:   

Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
 cadNotificationMib 1.3.6.1.4.1.4998.1.1.6.1
This MIB defines object which are NOTIFICATION-TYPE and used to define the SNMP Traps generated from C4 CMTS.
     cadTrapMibObjects 1.3.6.1.4.1.4998.1.1.6.1.1
         cadTraps 1.3.6.1.4.1.4998.1.1.6.1.1.0
             aaaServerUnreachableTrap 1.3.6.1.4.1.4998.1.1.6.1.1.0.1
An event to report that the AAA (RADIUS or TACACS+) server is not responding
             aaaServerGroupUnreachableTrap 1.3.6.1.4.1.4998.1.1.6.1.1.0.2
An event to report that all the hosts in the AAA (RADIUS or TACACS+) server group are not responding
             aaaServerAuthFailTrap 1.3.6.1.4.1.4998.1.1.6.1.1.0.3
An event to report that AAA (RADIUS or TACACS+) server rejected the authentication request
             secuLocalAuthFailTrap 1.3.6.1.4.1.4998.1.1.6.1.1.0.4
An event to report that local password authentication failed
             secuLineAuthFailTrap 1.3.6.1.4.1.4998.1.1.6.1.1.0.5
An event to report that line password authentication failed
             rip2AuthFailTrap 1.3.6.1.4.1.4998.1.1.6.1.1.0.6
An event to report rip2 authentication failed.
             cadIpdrNoPrimaryCollector 1.3.6.1.4.1.4998.1.1.6.1.1.0.7
An event to report IPDR Streaming is enabled but there is no primary collector connected.
             cadIpdrStreamingDisabled 1.3.6.1.4.1.4998.1.1.6.1.1.0.8
An event to report IPDR Streaming function has been turned off.
             cadIpdrReportCycleMissed 1.3.6.1.4.1.4998.1.1.6.1.1.0.9
An event to report CMTS was not able to start the scheduled IPDR report cycle session on time. This may be due to system or network load or the lack of primary collector connection.
             cadLinkUp 1.3.6.1.4.1.4998.1.1.6.1.1.0.10
This is to expand standard linkUp trap to include ifDescr. A linkUp trap signifies that the SNMP entity, acting in an agent role, has detected that the ifOperStatus object for one of its communication links left the down state and transitioned into some other state (but not into the notPresent state). This other state is indicated by the included value of ifOperStatus.
         cadTrapsInfo 1.3.6.1.4.1.4998.1.1.6.1.1.1
             securityInfo 1.3.6.1.4.1.4998.1.1.6.1.1.1.1 displaystring no-access
The detail security failure information
             ipdrInfo 1.3.6.1.4.1.4998.1.1.6.1.1.1.2 displaystring no-access
The detail IPDR failure information