Baytech-MIB-401-4: View SNMP OID List / Download MIB
VENDOR: BAY TECHNICAL ASSOCIATES
Home | MIB: Baytech-MIB-401-4 | |||
---|---|---|---|---|
Download as: |
Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
|
|||
Object Name | OID | Type | Access | Info |
baytech | 1.3.6.1.4.1.4779 | |||
btadevices | 1.3.6.1.4.1.4779.1 | |||
sBTAIdent | 1.3.6.1.4.1.4779.1.1 | |||
sBTAIdentFirmwareRev | 1.3.6.1.4.1.4779.1.1.1 | displaystring | read-only |
An 8 byte ID string identifying the DS72 firmware revision. This value is set at the factory. |
sBTAIdentSerialNumber | 1.3.6.1.4.1.4779.1.1.2 | integer | read-only |
A number identifying the serial number of the DS72. This value is set at the factory. |
sBTAIdentUnitName | 1.3.6.1.4.1.4779.1.1.3 | displaystring | read-write |
A 64-character string identifying the name (UnitID) of the DS72. This value is set at the factory to a default of DS72. |
sBTANetworkConfig | 1.3.6.1.4.1.4779.1.2 | |||
sBTANetworkConfigBootpEnable | 1.3.6.1.4.1.4779.1.2.1 | integer | read-write |
Enables/disables bootp. Bootp will not take effect until the unit is reseted. Enumeration: 'disabled': 0, 'enabled': 1. |
sBTANetworkConfigDHCPEnable | 1.3.6.1.4.1.4779.1.2.2 | integer | read-write |
Enables/disables DHCP. DHCP will not take effect until the unit is reseted. Enumeration: 'disabled': 0, 'enabled': 1. |
sBTANetworkConfigSSHEnable | 1.3.6.1.4.1.4779.1.2.3 | integer | read-write |
Enables/disables SSH logins. Disable/enable SSH will take effect after the unit is reseted. Enumeration: 'disabled': 0, 'enabled': 1. |
sBTANetworkConfigTelnetEnable | 1.3.6.1.4.1.4779.1.2.4 | integer | read-write |
Enables/disables telnet. Enumeration: 'disabled': 0, 'enabled': 1. |
sBTANetworkConfigActivityTimeout | 1.3.6.1.4.1.4779.1.2.5 | integer | read-write |
A value from 0 to 120. 0 disables activity timeouts. Value represents minutes of non-activity before telnet / SSH sessions are automatically logged out. Default is 0. |
sBTANetworkConfigDirectConnEnable | 1.3.6.1.4.1.4779.1.2.6 | integer | read-write |
Enables/disables direct port connection upon login. Enumeration: 'disabled': 0, 'enabled': 1. |
sBTANetworkConfigSNMP | 1.3.6.1.4.1.4779.1.2.8 | |||
sBTANetworkConfigSNMPReadOnlyCommunity | 1.3.6.1.4.1.4779.1.2.8.1 | displaystring | read-write |
The community name to use for read only access. Maximum len 16 bytes. |
sBTANetworkConfigSNMPReadWriteCommunity | 1.3.6.1.4.1.4779.1.2.8.2 | displaystring | read-write |
The community name to use for read-write access. Maximum len 16 bytes. |
sBTANetworkConfigSNMPNumTrapReceivers | 1.3.6.1.4.1.4779.1.2.8.3 | integer | read-only |
The maximum number of managers to send traps to. Currently 4. |
sBTANetworkConfigSNMPTrapReceiverTable | 1.3.6.1.4.1.4779.1.2.8.4 | no-access |
A list of managers to send traps to. The number of entries is given by the value of sBTANetworkConfigSNMPNumTrapReceivers. Maximum number of Trap Receivers is four. |
|
1.3.6.1.4.1.4779.1.2.8.4.1 | no-access |
Table of managers to send traps to. |
||
trapIndex | 1.3.6.1.4.1.4779.1.2.8.4.1.1 | integer | read-only |
The index to a trap receiver entry. |
receiverAddress | 1.3.6.1.4.1.4779.1.2.8.4.1.2 | ipaddress | read-write |
The IP address of the manager to send traps to. |
sBTANetworkConfigRadius | 1.3.6.1.4.1.4779.1.2.9 | |||
sBTANetworkConfigRadiusEnable | 1.3.6.1.4.1.4779.1.2.9.1 | integer | read-write |
Enables / disables RADIUS telnet logins. Enumeration: 'enable': 1, 'disable': 0. |
sBTANetworkConfigRadiusPrimaryServer | 1.3.6.1.4.1.4779.1.2.9.2 | ipaddress | read-write |
Ip address of the primary RADIUS server. |
sBTANetworkConfigRadiusSecondaryServer | 1.3.6.1.4.1.4779.1.2.9.3 | ipaddress | read-write |
Ip address of the back-up RADIUS server. |
sBTANetworkConfigRadiusLocalLogin | 1.3.6.1.4.1.4779.1.2.9.4 | integer | read-write |
Enables / disables the use of local (usernames stored in the DS72) logins in the case that both the primary and secondary RADIUS server are not available. Enumeration: 'enable': 1, 'disable': 0. |
sBTANetworkConfigWEB | 1.3.6.1.4.1.4779.1.2.10 | |||
sBTANetworkConfigWebEnable | 1.3.6.1.4.1.4779.1.2.10.1 | integer | read-write |
Enables WEB. Enumeration: 'disabled': 0, 'enabled': 1. |
sBTANetworkConfigWebSecureEnable | 1.3.6.1.4.1.4779.1.2.10.2 | integer | read-write |
Enables WEB Security. Enumeration: 'disabled': 0, 'enabled': 1. |
sBTANetworkConfigWebLoginEnable | 1.3.6.1.4.1.4779.1.2.10.3 | integer | read-write |
Enables WEB Login. Enumeration: 'disabled': 0, 'enabled': 1. |
sBTANetworkConfigWebActivityTimeout | 1.3.6.1.4.1.4779.1.2.10.4 | integer | read-write |
A value from 0 to 120. 0 disables WEB activity timeouts. Value represents minutes of non-activity before WEB sessions are automatically logged out. Default is 0. |
sBTAModules | 1.3.6.1.4.1.4779.1.3 | |||
sBTAModulesNumberOfModules | 1.3.6.1.4.1.4779.1.3.1 | integer | read-only |
Number of modules installed into the DS unit. |
sBTAModulesModulesInstalled | 1.3.6.1.4.1.4779.1.3.2 | displaystring | read-only |
A character string listing the modules installed seperated by commas. Each module is identifed by a two digit number indicating the slot. For example 02,03,04,06 means modules 2,3,4 and 6 are installed. |
sBTAModulesResetModulesCmd | 1.3.6.1.4.1.4779.1.3.3 | integer | read-only |
This command is no longer supported. |
sBTAModulesNumberOfIntelligentModules | 1.3.6.1.4.1.4779.1.3.4 | integer | read-only |
The number of Intelligent Modules installed in the DS Unit. |
sBTAModulesRPC | 1.3.6.1.4.1.4779.1.3.5 | |||
sBTAModulesNumberOfRPCModules | 1.3.6.1.4.1.4779.1.3.5.1 | integer | read-only |
The number of DS30 Modules installed in the DS Unit. |
sBTAModulesRPCTable | 1.3.6.1.4.1.4779.1.3.5.2 | no-access |
Allows for control of individual outlets and individual RPC modules. |
|
1.3.6.1.4.1.4779.1.3.5.2.1 | no-access |
The RPCs to control and get status on. |
||
sBTAModulesRPCIndex | 1.3.6.1.4.1.4779.1.3.5.2.1.1 | integer | read-only |
The index into the RPC table. Indexes for rpcs attached to ds74 modules are calculate with the following formula: ((module - 2) * 4) + port. For example module 3 port 1 = index 5. |
sBTAModulesRPCName | 1.3.6.1.4.1.4779.1.3.5.2.1.2 | displaystring | read-write |
The name (unit id) of the rpc. |
sBTAModulesRPCFirmwareVersion | 1.3.6.1.4.1.4779.1.3.5.2.1.3 | displaystring | read-only |
The firware version of the rpc. |
sBTAModulesRPCCurrent | 1.3.6.1.4.1.4779.1.3.5.2.1.4 | integer | read-only |
The current reading for the power strip. If current measurement is not installed this value will always read 0. |
sBTAModulesRPCMaxCurrent | 1.3.6.1.4.1.4779.1.3.5.2.1.5 | integer | read-write |
The maximum detected current reading for the power strip. If current measurement is not installed this value will always read 0. Setting this value to 0 will clear the maximum current detected. |
sBTAModulesRPCVoltage | 1.3.6.1.4.1.4779.1.3.5.2.1.6 | integer | read-only |
The voltage reading for the power strip. If voltage measurement is not installed this value will always read 0. |
sBTAModulesRPCPower | 1.3.6.1.4.1.4779.1.3.5.2.1.7 | integer | read-only |
The power reading for the power strip. If power measurement is not installed this value will always read 0. |
sBTAModulesRPCTemperature | 1.3.6.1.4.1.4779.1.3.5.2.1.8 | integer | read-only |
The temperature reading for the power strip. Readings are in degrees C. If temperature measurement is not installed this value will always read 0. |
sBTAModulesRPCRebootTimeout | 1.3.6.1.4.1.4779.1.3.5.2.1.9 | integer | read-only |
The length of off time for automatic reboot sequences. Currently a read-only value set to the fixed reboot timeout. |
sBTAModulesRPCAllOutletsCmd | 1.3.6.1.4.1.4779.1.3.5.2.1.10 | integer | read-write |
Turns all outlets on, off or reboot. 0 = off 1 = on 2 = reboot A get will return unknown (6). Enumeration: 'on': 1, 'off': 0, 'unknown': 6, 'reboot': 2, 'lockon': 3, 'unlock': 5, 'lockoff': 4. |
sBTAModulesRPCAllOutletsStatus | 1.3.6.1.4.1.4779.1.3.5.2.1.11 | displaystring | read-only |
Reports status of outlets in a comma deliminated string. 0 = off 1 = on 2 = reboot 3 = locked on 4 = locked off |
sBTAModulesRPCCurrentAlarmThreshold | 1.3.6.1.4.1.4779.1.3.5.2.1.12 | integer | read-write |
The current alarm threshold level *10. A value of 105 will set the level to 10.5. |
sBTAModulesRPCOverVoltageThreshold | 1.3.6.1.4.1.4779.1.3.5.2.1.13 | integer | read-write |
The over voltage alarm threshold level *10. A value of 105 will set the level to 10.5. |
sBTAModulesRPCUnderVoltageThreshold | 1.3.6.1.4.1.4779.1.3.5.2.1.14 | integer | read-write |
The under voltage alarm threshold level *10. A value of 105 will set the level to 10.5. |
sBTAModulesRPCNumberOfOutlets | 1.3.6.1.4.1.4779.1.3.5.2.1.15 | integer | read-only |
Number of outlets for this RPC. This will be the size of outlet table for this RPC index. |
sBTAModulesRPCCircuitBreaker | 1.3.6.1.4.1.4779.1.3.5.2.1.16 | integer | read-only |
Status of circuit breaker in power strip. 0=off 1=on. Enumeration: 'on': 1, 'off': 0. |
sBTAModulesRPCOverTempThreshold | 1.3.6.1.4.1.4779.1.3.5.2.1.17 | integer | read-write |
The over temperature alarm threshold level *10. A value of 505 will set the level to 50.5. |
sBTAModulesRPCUnitVA | 1.3.6.1.4.1.4779.1.3.5.2.1.18 | integer | read-only |
Total Volt-Amps for this RPC. |
sBTAModulesRPCNumberOfBreakers | 1.3.6.1.4.1.4779.1.3.5.2.1.19 | integer | read-only |
Number of breakers for this RPC. |
sBTAModulesRPCLowCurrentThreshold | 1.3.6.1.4.1.4779.1.3.5.2.1.20 | integer | read-write |
Low current threshold for this RPC. |
sBTAModulesRPCVoltageSource | 1.3.6.1.4.1.4779.1.3.5.2.1.21 | integer | read-write |
Voltage source for this RPC. |
sBTAModulesRPCSourceSwitchCount | 1.3.6.1.4.1.4779.1.3.5.2.1.22 | integer | read-only |
Count of Voltage Source Switches for this RPC. |
sBTAModulesRPCNumberOfSensors | 1.3.6.1.4.1.4779.1.3.5.2.1.23 | integer | read-only |
Number of environmental sensors for this RPC. |
sBTAModulesRPCType | 1.3.6.1.4.1.4779.1.3.5.2.1.24 | displaystring | read-only |
The type of RPC installed at the indexed location. |
sBTAModulesRPCOutletTable | 1.3.6.1.4.1.4779.1.3.5.3 | no-access |
Allows for control of individual outlets. The number of entries is contained in the sBTAModulesRPCOutletTableSize OID. |
|
1.3.6.1.4.1.4779.1.3.5.3.1 | no-access |
The outlets to control and get status on. |
||
sBTAModulesRPCOutletModuleIndex | 1.3.6.1.4.1.4779.1.3.5.3.1.1 | integer | read-only |
The index to the outlet entry. |
sBTAModulesRPCOutletIndex | 1.3.6.1.4.1.4779.1.3.5.3.1.2 | integer | read-only |
The index to the outlet entry. |
sBTAModulesRPCOutletState | 1.3.6.1.4.1.4779.1.3.5.3.1.3 | integer | read-write |
Getting this variable will return the state of the outlet. Valid return states are unknown, on, off, lockon, lockoff. 0 = off 1 = on 2 = reboot 3 = lockon (outlet is on and no changes are allowed) 4 = lockoff (outlet is off and no changes are allowed) 5 = unlock. Enumeration: 'on': 1, 'off': 0, 'unknown': 6, 'reboot': 2, 'lockon': 3, 'unlock': 5, 'lockoff': 4. |
sBTAModulesRPCOutletName | 1.3.6.1.4.1.4779.1.3.5.3.1.4 | displaystring | read-write |
The name of the outlet. Maximum size is 16 characters. |
sBTAModulesRPCGroupCmd | 1.3.6.1.4.1.4779.1.3.5.4 | displaystring | read-write |
A character string listing the outlets that need to be controlled, turned off, or turn on as a group. Command is the first character followed by a space. Valid commads are 0=off,1=on, or 2=reboot. A list follows the command in the format module.outlet. For example 2 2.1,2.12,3.1 will reboot module 2 outlet 2&12 module 3 outlet 1. |
sBTAModulesRPCModPortTable | 1.3.6.1.4.1.4779.1.3.5.5 | no-access |
Allows for control of individual outlets and individual RPC modules. The number of entries is contained in the sBTAModulesNumberOfRPCModules OID. |
|
1.3.6.1.4.1.4779.1.3.5.5.1 | no-access |
The RPCs to control and get status on. |
||
sRPCModuleIndex | 1.3.6.1.4.1.4779.1.3.5.5.1.1 | integer | read-only |
The module number index into the RPC table. |
sRPCPortIndex | 1.3.6.1.4.1.4779.1.3.5.5.1.2 | integer | read-only |
The port number index into the RPC table. In the case of ds30 modules this number is always 1. |
sRPCType | 1.3.6.1.4.1.4779.1.3.5.5.1.3 | displaystring | read-only |
Type of RPC at the module, port index. |
sRPCName | 1.3.6.1.4.1.4779.1.3.5.5.1.4 | displaystring | read-write |
The name (unit id) of the rpc module. |
sRPCFirmwareVersion | 1.3.6.1.4.1.4779.1.3.5.5.1.5 | displaystring | read-only |
The firware version of the rpc module. |
sRPCCurrent | 1.3.6.1.4.1.4779.1.3.5.5.1.6 | integer | read-only |
The current reading for the power strip. If current measurement is not installed this value will always read 0. |
sRPCMaxCurrent | 1.3.6.1.4.1.4779.1.3.5.5.1.7 | integer | read-write |
The maximum detected current reading for the power strip. If current measurement is not installed this value will always read 0. Setting this value to 0 will clear the maximum current detected. |
sRPCVoltage | 1.3.6.1.4.1.4779.1.3.5.5.1.8 | integer | read-only |
The voltage reading for the power strip. If voltage measurement is not installed this value will always read 0. |
sRPCPower | 1.3.6.1.4.1.4779.1.3.5.5.1.9 | integer | read-only |
The power reading for the power strip. If power measurement is not installed this value will always read 0. |
sRPCTemperature | 1.3.6.1.4.1.4779.1.3.5.5.1.10 | integer | read-only |
The temperature reading for the power strip. Readings are in degrees C. If temperature measurement is not installed this value will always read 0. |
sRPCRebootTimeout | 1.3.6.1.4.1.4779.1.3.5.5.1.11 | integer | read-write |
The length of off time for automatic reboot sequences. Currently a read-only value set to the fixed reboot timeout. |
sRPCAllOutletsCmd | 1.3.6.1.4.1.4779.1.3.5.5.1.12 | integer | read-write |
Turns all outlets on, off or reboot. 0 = off 1 = on 2 = reboot 3 = lockon (will lock outlets to on state) 4 = lockoff (will lock outlets to off state) 5 = unlock (will unlock all outlets) A get will return unknown (6). Enumeration: 'on': 1, 'off': 0, 'unknown': 6, 'reboot': 2, 'lockon': 3, 'unlock': 5, 'lockoff': 4. |
sRPCAllOutletsStatus | 1.3.6.1.4.1.4779.1.3.5.5.1.13 | displaystring | read-only |
Reports status of outlets in a comma deliminated string. 0 = off 1 = on 2 = reboot 3 = locked on 4 = locked off |
sRPCCurrentAlarmThreshold | 1.3.6.1.4.1.4779.1.3.5.5.1.14 | integer | read-write |
The current alarm threshold level *10. A value of 105 will set the level to 10.5. |
sRPCOverVoltageThreshold | 1.3.6.1.4.1.4779.1.3.5.5.1.15 | integer | read-write |
The over voltage alarm threshold level *10. A value of 105 will set the level to 10.5. |
sRPCUnderVoltageThreshold | 1.3.6.1.4.1.4779.1.3.5.5.1.16 | integer | read-write |
The under voltage alarm threshold level *10. A value of 105 will set the level to 10.5. |
sRPCNumberOfOutlets | 1.3.6.1.4.1.4779.1.3.5.5.1.17 | integer | read-only |
Number of outlets for this RPC. This will be the size of outlet table for this RPC index. |
sRPCCircuitBreaker | 1.3.6.1.4.1.4779.1.3.5.5.1.18 | integer | read-only |
Status of circuit breaker in power strip. 0=off 1=on. Enumeration: 'on': 1, 'off': 0. |
sRPCOverTempThreshold | 1.3.6.1.4.1.4779.1.3.5.5.1.19 | integer | read-write |
The over temperature alarm threshold level *10. A value of 505 will set the level to 50.5. |
sRPCUnitVA | 1.3.6.1.4.1.4779.1.3.5.5.1.20 | integer | read-only |
Number of outlets for this RPC. This will be the size of outlet table for this RPC index. |
sRPCNumberOfBreakers | 1.3.6.1.4.1.4779.1.3.5.5.1.21 | integer | read-only |
Number of breakers for this RPC. |
sRPCLowCurrentThreshold | 1.3.6.1.4.1.4779.1.3.5.5.1.22 | integer | read-write |
Low current threshold for this RPC. |
sRPCVoltageSource | 1.3.6.1.4.1.4779.1.3.5.5.1.23 | integer | read-write |
Voltage source for this RPC. |
sRPCSourceSwitchCount | 1.3.6.1.4.1.4779.1.3.5.5.1.24 | integer | read-write |
Voltage source switch count for this RPC. |
sRPCNumberOfSensors | 1.3.6.1.4.1.4779.1.3.5.5.1.25 | integer | read-only |
Number of sensors for this RPC. |
sBTAModulesRPCModPortOutletTable | 1.3.6.1.4.1.4779.1.3.5.6 | no-access |
Allows for control of individual outlets. The number of entries is contained in the sBTAModulesRPCOutletTableSize OID. |
|
1.3.6.1.4.1.4779.1.3.5.6.1 | no-access |
The outlets to control and get status on. |
||
sRPCOutletModuleIndex | 1.3.6.1.4.1.4779.1.3.5.6.1.1 | integer | read-only |
The module index to the outlet entry. |
sRPCOutletPortIndex | 1.3.6.1.4.1.4779.1.3.5.6.1.2 | integer | read-only |
The port index to the outlet entry. In the case of ds30s this number is always 1. |
sRPCOutletIndex | 1.3.6.1.4.1.4779.1.3.5.6.1.3 | integer | read-only |
The outlet index to the outlet entry. |
sRPCOutletState | 1.3.6.1.4.1.4779.1.3.5.6.1.4 | integer | read-write |
Getting this variable will return the state of the outlet. Valid return states are unknown, on, off, lockon, lockoff. 0 = off 1 = on 2 = reboot 3 = lockon (outlet is on and no changes are allowed) 4 = lockoff (outlet is off and no changes are allowed) 5 = unlock. Enumeration: 'on': 1, 'off': 0, 'unknown': 6, 'reboot': 2, 'lockon': 3, 'unlock': 5, 'lockoff': 4. |
sRPCOutletName | 1.3.6.1.4.1.4779.1.3.5.6.1.5 | displaystring | read-write |
The name of the outlet. Maximum size is 16 characters. |
sBTAModulesRPCModPortGroupCmd | 1.3.6.1.4.1.4779.1.3.5.7 | displaystring | read-write |
A character string listing the outlets that need to be rebooted, turned off, or turn on as a group. Command is the first character followed by a space. Valid commads are 0=off,1=on, or 2=reboot. A list follows the command in the format module.port.outlet. For example 2 2.1.1,2.1.12,3.4.1 will reboot module 2 port 1 outlet 2&12 module 3 port 4 outlet 1. |
sBTAModulesRPCCurrentGroupsCurrentTable | 1.3.6.1.4.1.4779.1.3.5.8 | no-access |
A list of total current for RPCs in each current group |
|
1.3.6.1.4.1.4779.1.3.5.8.1 | no-access |
Table of total current measurement by group |
||
groupCurrentIndex | 1.3.6.1.4.1.4779.1.3.5.8.1.1 | integer | read-only |
The index to a group total current. |
groupCurrent | 1.3.6.1.4.1.4779.1.3.5.8.1.2 | integer | read-only |
Current total for all RPCs in group. |
rpcGroup | 1.3.6.1.4.1.4779.1.3.5.8.1.3 | displaystring | read-write |
A character string listing the RPCs, by port index, that will be included in a measurement of total current. For each group, a sum will be periodically computed of currents of all listed RPCs, which will be compared to warning and emergency thresholds, generating appropriate traps as required by transit of a threshold. A maximum of 8 RPCs may be monitored within a group. The RPC must be connected and operating and the corresponding DS74 serial port must be configured for an RPC-SNMP device type to be allowed group membership. |
warningThreshold | 1.3.6.1.4.1.4779.1.3.5.8.1.4 | integer | read-write |
The current level, in tenths of an amp, that will cause a Current Level Warning trap to be sent if the total current for the associated group if exceeded. Conversely, a Current Level Warning Clear trap will be sent whent the total group current falls below the threshold. |
emergencyThreshold | 1.3.6.1.4.1.4779.1.3.5.8.1.5 | integer | read-write |
The current level, in tenths of an amp, that will cause a Current Level Emergency trap to be sent if the total current for the associated group if exceeded. Conversely, a Current Level Emergeny Clear trap will be sent whent the total group current falls below the threshold. |
sBTAModulesRPCBreakersTable | 1.3.6.1.4.1.4779.1.3.5.9 | no-access |
Allows monitoring of individual outlet strips on RPCs. |
|
1.3.6.1.4.1.4779.1.3.5.9.1 | no-access |
Status organization by breaker. |
||
sBTAModulesRPCBreakersModulesIndex | 1.3.6.1.4.1.4779.1.3.5.9.1.1 | integer | read-only |
The index into the RPC table. |
sBTAModulesRPCBreakersBreakersIndex | 1.3.6.1.4.1.4779.1.3.5.9.1.2 | integer | read-only |
The index into the RPC breaker table. |
sBTAModulesRPCBreakersCircuitBreaker | 1.3.6.1.4.1.4779.1.3.5.9.1.3 | integer | read-only |
Status of circuit breaker in power strip. 0=off 1=on. Enumeration: 'on': 1, 'off': 0. |
sBTAModulesRPCBreakersCurrent | 1.3.6.1.4.1.4779.1.3.5.9.1.4 | integer | read-only |
The detected current reading for the power strip. If current measurement is not installed this value will always read 0. |
sBTAModulesRPCBreakersMaxCurrent | 1.3.6.1.4.1.4779.1.3.5.9.1.5 | integer | read-only |
The maximum detected current reading for the power strip. If current measurement is not installed this value will always read 0. |
sBTAModulesRPCBreakersVoltage | 1.3.6.1.4.1.4779.1.3.5.9.1.6 | integer | read-only |
The voltage reading for the power strip. If voltage measurement is not installed this value will always read 0. |
sBTAModulesRPCBreakersPower | 1.3.6.1.4.1.4779.1.3.5.9.1.7 | integer | read-only |
The power reading for the power strip. If voltage measurement is not installed this value will always read 0. |
sBTAModulesRPCBreakersVA | 1.3.6.1.4.1.4779.1.3.5.9.1.8 | integer | read-only |
The volt-amps reading for the power strip. If voltage measurement is not installed this value will always read 0. |
sBTAModulesRPCBreakersCurrentAlarmThreshold | 1.3.6.1.4.1.4779.1.3.5.9.1.9 | integer | read-write |
The current alarm threshold level *10. A value of 105 will set the level to 10.5. |
sRPCModPortBreakersTable | 1.3.6.1.4.1.4779.1.3.5.10 | no-access |
Allows monitoring of individual outlet strips on RPCs. |
|
1.3.6.1.4.1.4779.1.3.5.10.1 | no-access |
Status organization by breaker. |
||
sRPCBreakersModIndex | 1.3.6.1.4.1.4779.1.3.5.10.1.1 | integer | read-only |
The module index into the RPC breaker table. |
sRPCBreakersPortIndex | 1.3.6.1.4.1.4779.1.3.5.10.1.2 | integer | read-only |
The port index into the RPC breaker table. |
sRPCBreakersBreakersIndex | 1.3.6.1.4.1.4779.1.3.5.10.1.3 | integer | read-only |
The breaker index into the RPC breaker table. |
sRPCBreakersCircuitBreaker | 1.3.6.1.4.1.4779.1.3.5.10.1.4 | integer | read-only |
Status of circuit breaker in power strip. 0=off 1=on. Enumeration: 'on': 1, 'off': 0. |
sRPCBreakersCurrent | 1.3.6.1.4.1.4779.1.3.5.10.1.5 | integer | read-only |
The detected current reading for the power strip. If current measurement is not installed this value will always read 0. |
sRPCBreakersMaxCurrent | 1.3.6.1.4.1.4779.1.3.5.10.1.6 | integer | read-only |
The maximum detected current reading for the power strip. If current measurement is not installed this value will always read 0. |
sRPCBreakersVoltage | 1.3.6.1.4.1.4779.1.3.5.10.1.7 | integer | read-only |
The voltage reading for the power strip. If voltage measurement is not installed this value will always read 0. |
sRPCBreakersPower | 1.3.6.1.4.1.4779.1.3.5.10.1.8 | integer | read-only |
The power reading for the power strip. If voltage measurement is not installed this value will always read 0. |
sRPCBreakersVA | 1.3.6.1.4.1.4779.1.3.5.10.1.9 | integer | read-only |
The volt-amps reading for the power strip. If voltage measurement is not installed this value will always read 0. |
sRPCBreakersCurrentAlarmThreshold | 1.3.6.1.4.1.4779.1.3.5.10.1.10 | integer | read-write |
The current alarm threshold level x10. A value of 105 will set the level to 10.5. |
sBTAModulesSerial | 1.3.6.1.4.1.4779.1.3.6 | |||
sBTAModulesModem | 1.3.6.1.4.1.4779.1.3.7 | |||
sBTAControl | 1.3.6.1.4.1.4779.1.4 | |||
sBTAControlResetUnit | 1.3.6.1.4.1.4779.1.4.1 | integer | read-write |
Setting this value to 1 will cause the unit to reset. A get of this OID will return 0. Enumeration: 'reset': 1, 'noreset': 0. |
sBTAControlResetModules | 1.3.6.1.4.1.4779.1.4.2 | integer | read-write |
Setting this value to 1 will cause the unit to reset modules simular to the telnet RM command. A get of this OID will return 0. Enumeration: 'reset': 1, 'noreset': 0. |
sBTAControlNumOfLoggedUsers | 1.3.6.1.4.1.4779.1.4.3 | integer | read-only |
Number of users logged in via telnet or SSH. |
sBTAControlUserTable | 1.3.6.1.4.1.4779.1.4.4 | no-access |
A list of users and user information. The number of entries is contained in the sBTAControlNumOfLoggedUsers OID. |
|
1.3.6.1.4.1.4779.1.4.4.1 | no-access |
The users to get status on. |
||
sBTAControlUserIndex | 1.3.6.1.4.1.4779.1.4.4.1.1 | integer | read-only |
The index to the user entry. |
sBTAControlUserName | 1.3.6.1.4.1.4779.1.4.4.1.2 | displaystring | read-only |
The username of the user. |
sBTAControlUserAddress | 1.3.6.1.4.1.4779.1.4.4.1.3 | ipaddress | read-only |
The IP address of the user. |
sBTAControlUserConnection | 1.3.6.1.4.1.4779.1.4.4.1.4 | integer | read-only |
Type of connection. If unknown, user is logging out or the connection is invalid. Enumeration: 'unknown': 4, 'ssh': 2, 'telnet': 1, 'serialport': 0. |
sBTAControlUserConnModule | 1.3.6.1.4.1.4779.1.4.4.1.5 | integer | read-only |
If the user is connected to a module, this value will report the module number connected to. If the value is 0 the user is not connected to a module. |
sBTAControlUserConnPort | 1.3.6.1.4.1.4779.1.4.4.1.6 | integer | read-only |
The port number with in a module that the user is connected to. This usually only applies to connections to DS74 serial modules. Intelligent modules connections are always made on port 1. If value is 0 the user is not connected to a module. |
sBTAControlUserTerminateUser | 1.3.6.1.4.1.4779.1.4.4.1.7 | integer | read-write |
Settings this OID to anything but 0 will terminate (log out) the user. A get of this OID will return 0. Enumeration: 'terminate': 1. |
sBTAFileTransfer | 1.3.6.1.4.1.4779.1.5 | |||
sBTAFileTransferEnableUpgradeFTPFileTransfer | 1.3.6.1.4.1.4779.1.5.1 | integer | read-write |
Setting this OID to enableUpgradeFileTransferDownloadViaFTP (1) will start the FTP server and place the DS72 in upgrade mode. An FTP connection may then be established for the purpose of transmitting a firmware upgrade file. Enumeration: 'enableUpgradeFileTransferDownloadViaFTP': 1. |
sBTAEnvironmental | 1.3.6.1.4.1.4779.1.6 | |||
sBTAModulesEnvironmentalObjectsTable | 1.3.6.1.4.1.4779.1.6.1 | no-access |
Allows monitoring of individual outlet strips on RPCs. |
|
1.3.6.1.4.1.4779.1.6.1.1 | no-access |
Status organization by sensor. |
||
sBTAModulesEnvironmentalModulesIndex | 1.3.6.1.4.1.4779.1.6.1.1.1 | integer | read-only |
Module Index for Environemntal table |
sBTAModulesEnvironmentalSensorsIndex | 1.3.6.1.4.1.4779.1.6.1.1.2 | integer | read-only |
Sensor Index for Environemntal table |
sBTAModulesEnvironmentalType | 1.3.6.1.4.1.4779.1.6.1.1.3 | integer | read-only |
Environmental Object Type. |
sBTAModulesEnvironmentalName | 1.3.6.1.4.1.4779.1.6.1.1.4 | displaystring | read-write |
The name for the environmental object. |
sBTAModulesEnvironmentalMeasurement | 1.3.6.1.4.1.4779.1.6.1.1.5 | integer | read-only |
The measurement or state for the object. |
sBTAModulesEnvironmentalHiThreshold | 1.3.6.1.4.1.4779.1.6.1.1.6 | integer | read-write |
Hi threshold for object. |
sBTAModulesEnvironmentalLoThreshold | 1.3.6.1.4.1.4779.1.6.1.1.7 | integer | read-write |
Lo threshold for object. |
sBTAModulesEnvironmentalMax | 1.3.6.1.4.1.4779.1.6.1.1.8 | integer | read-write |
Max value recorded for object since last reset. |
sBTAModulesEnvironmentalMin | 1.3.6.1.4.1.4779.1.6.1.1.9 | integer | read-write |
Min value recorded for object since last reset. |
sBTAModulesEnvironmentalHiThresholdEn | 1.3.6.1.4.1.4779.1.6.1.1.10 | integer | read-write |
Hi threshold enable for object. |
sBTAModulesEnvironmentalLoThresholdEn | 1.3.6.1.4.1.4779.1.6.1.1.11 | integer | read-write |
Lo threshold enable for object. |
sBTAModulesEnvironmentalStateTrapEn | 1.3.6.1.4.1.4779.1.6.1.1.12 | integer | read-write |
Trap enable for environmental sensors with contacts. |
sRPCEnvironmentalObjectsTable | 1.3.6.1.4.1.4779.1.6.2 | no-access |
Allows monitoring of individual outlet strips on RPCs. |
|
1.3.6.1.4.1.4779.1.6.2.1 | no-access |
Status organization by sensor. |
||
sRPCEnvironmentalModuleIndex | 1.3.6.1.4.1.4779.1.6.2.1.1 | integer | read-only |
Module Index for Environemntal table |
sRPCEnvironmentalPortIndex | 1.3.6.1.4.1.4779.1.6.2.1.2 | integer | read-only |
Port Index for Environemntal table |
sRPCEnvironmentalSensorsIndex | 1.3.6.1.4.1.4779.1.6.2.1.3 | integer | read-only |
Sensor Index for Environemntal table |
sRPCEnvironmentalType | 1.3.6.1.4.1.4779.1.6.2.1.4 | integer | read-only |
Environmental Object Type. |
sRPCEnvironmentalName | 1.3.6.1.4.1.4779.1.6.2.1.5 | displaystring | read-write |
The name for the environmental object. |
sRPCEnvironmentalMeasurement | 1.3.6.1.4.1.4779.1.6.2.1.6 | integer | read-only |
The measurement or state for the object. |
sRPCEnvironmentalHiThreshold | 1.3.6.1.4.1.4779.1.6.2.1.7 | integer | read-write |
Hi threshold for object. |
sRPCEnvironmentalLoThreshold | 1.3.6.1.4.1.4779.1.6.2.1.8 | integer | read-write |
Lo threshold for object. |
sRPCEnvironmentalMax | 1.3.6.1.4.1.4779.1.6.2.1.9 | integer | read-write |
Max value recorded for object since last reset. |
sRPCEnvironmentalMin | 1.3.6.1.4.1.4779.1.6.2.1.10 | integer | read-write |
Min value recorded for object since last reset. |
sRPCEnvironmentalHiThresholdEn | 1.3.6.1.4.1.4779.1.6.2.1.11 | integer | read-write |
Hi threshold enable for object. |
sRPCEnvironmentalLoThresholdEn | 1.3.6.1.4.1.4779.1.6.2.1.12 | integer | read-write |
Lo threshold enable for object. |
sRPCEnvironmentalStateTrapEn | 1.3.6.1.4.1.4779.1.6.2.1.13 | integer | read-write |
Trap enable for environmental sensors with contacts. |
sBTAEnvironmentalAllTemperatureSensorsHiThreshold | 1.3.6.1.4.1.4779.1.6.3 | integer | read-write |
Hi Threshold for all temperature sensors. |
sBTAEnvironmentalAllTemperatureSensorsLoThreshold | 1.3.6.1.4.1.4779.1.6.4 | integer | read-write |
Lo Threshold for all temperature sensors. |
sBTAEnvironmentalAllTemperatureSensorsHiThresholdTrapEnable | 1.3.6.1.4.1.4779.1.6.5 | integer | read-write |
Hi Threshold trap enable for all temperature sensors. |
sBTAEnvironmentalAllTemperatureSensorsLoThresholdTrapEnable | 1.3.6.1.4.1.4779.1.6.6 | integer | read-write |
Lo Threshold trap enable for all temperature sensors. |
sBTAEnvironmentalAllSensorsStateTrapEnable | 1.3.6.1.4.1.4779.1.6.7 | integer | read-write |
State change environmental sensor (ex: contact) trap enable. |
mtrapargs | 1.3.6.1.4.1.4779.3 | |||
mtrapargsInteger | 1.3.6.1.4.1.4779.3.1 | integer | read-only |
This OID allows baytech traps to be sent with an integer argument that may not be defined in the baytech MIB. A get of this OID will return 0. |
mtrapargsIpAddress | 1.3.6.1.4.1.4779.3.2 | ipaddress | read-only |
This OID allows bayteh traps to be sent with an IP address argument that may not be defined in the baytech MIB. A get of this OID will return 0.0.0.0. |
mtrapargsString | 1.3.6.1.4.1.4779.3.3 | displaystring | read-only |
This OID allows baytech traps to be sent with an octet string argument that may not be defined in the baytech MIB. A get of this OID will return a NULL string. |
mtrapargsGauge | 1.3.6.1.4.1.4779.3.4 | gauge | read-only |
This OID allows baytech traps to be sent with a Gauge argument that may not be defined in the baytech MIB. A get of this OID will return 0. |
mtrapargsTimeTicks | 1.3.6.1.4.1.4779.3.5 | timeticks | read-only |
This OID allows baytech traps to be sent with a TimeTicks argument that may not be defined in the baytech MIB. A get of this OID will return 0. |
sBTAModuleIndex | 1.3.6.1.4.1.4779.3.6 | integer | read-only |
This OID allows baytech traps to be sent with an integer argument that may not be defined in the baytech MIB. This is an index to a specific DS module. Value will equal the slot of the module. A get of this OID will return 0. |
sBTAOutletIndex | 1.3.6.1.4.1.4779.3.7 | integer | read-only |
This OID allows baytech traps to be sent with an integer argument that may not be defined in the baytech MIB. This is an index to a specific outlet in a DS module. Value is 1 to number of outlets controlled by the ds module. 0 represents all outlets. A get of this OID will return 0. |
sBTAPortIndex | 1.3.6.1.4.1.4779.3.8 | integer | read-only |
This OID allows baytech traps to be sent with an integer argument that may not be defined in the baytech MIB. This is an index to a specific outlet in a DS module. Value is 1 to number of outlets controlled by the ds module. 0 represents all outlets. A get of this OID will return 0. |
sBTAVoltageSource | 1.3.6.1.4.1.4779.3.9 | integer | read-write |
This OID allows baytech traps to be sent with an integer argument that may not be defined in the baytech MIB. This is the number associated with the voltage source in an RPC. Value is 1 or 2, depending on which voltage source is powering the RPC. A get of this OID will return 0. |
sBTASourceSwitchCount | 1.3.6.1.4.1.4779.3.10 | integer | read-only |
This OID allows baytech traps to be sent with an integer argument that may not be defined in the baytech MIB. This is the number associated with the number of voltage source transitions in an RPC. Value is 0 to 255, an 8-bit w/rollover count of number of times voltage source has been switched from one source to another. A get of this OID will return 0. |
sBTASensorIndex | 1.3.6.1.4.1.4779.3.11 | integer | read-only |
This OID allows baytech traps to be sent with an integer argument that may not be defined in the baytech MIB. This is an index to a specific sensor in a DS module. Value is 1 to number of sensors controlled by the ds module. A get of this OID will return 0. |
sBTABreakerIndex | 1.3.6.1.4.1.4779.3.12 | integer | read-only |
This is an object which is sent along with a trap to designate a breaker number pertinent to a particular trap. This value will range from 1 to the total number of breakers inside the particular RPC. A get of this OID will return 0. |
communicationLost | 1.3.6.1.4.1.47790.1 |
SEVERE: Communication to the unit has been lost. Steps to reestablish communication are in progress. Argument is timeTicks when communication was lost. |
||
communicationEstablished | 1.3.6.1.4.1.47790.2 |
INFORMATION: Communication with the unit has been established. Argument is timeTicks when communication was established. |
||
outletOn | 1.3.6.1.4.1.47790.3 |
WARNING: The specified RPC outlet has turned on. If sBTAOutletIndex equals zero, then all outlets have turned on. |
||
outletOff | 1.3.6.1.4.1.47790.4 |
WARNING: The specified RPC outlet has turned off. If sBTAOutletIndex equals zero, then all outlets have turned off. |
||
outletReboot | 1.3.6.1.4.1.47790.5 |
WARNING: The specified RPC outlet has rebooted. If sBTAOutletIndex equals zero, then all outlets have rebooted. |
||
outletLocked | 1.3.6.1.4.1.47790.6 |
WARNING: The specified RPC outlet has been locked. If sBTAOutletIndex equals zero, then all outlets have been locked. |
||
outletUnlocked | 1.3.6.1.4.1.47790.7 |
WARNING: The specified RPC outlet has been unlocked. If sBTAOutletIndex equals zero, then all outlets have been unlocked. |
||
configChangeSNMP | 1.3.6.1.4.1.47790.8 |
WARNING: The SNMP configuration has been changed. |
||
configChangeOutlet | 1.3.6.1.4.1.47790.9 |
WARNING: The specified outlet has changed configuration. |
||
accessViolationConsole | 1.3.6.1.4.1.47790.10 |
WARNING: Someone has attempted to login via the console with the incorrect password. |
||
accessViolationNetwork | 1.3.6.1.4.1.47790.11 |
WARNING: Someone has attempted to login via the network with the incorrect password. |
||
userPasswordChange | 1.3.6.1.4.1.47790.12 |
WARNING: The password for the specified user has been changed. |
||
userAdded | 1.3.6.1.4.1.47790.13 |
WARNING: The specified user has been added. |
||
userLoggedIn | 1.3.6.1.4.1.47790.14 |
INFORMATIONAL: The specified user has logged in. |
||
temperatureThresholdViolation | 1.3.6.1.4.1.47790.15 |
WARNING: A temperature threshold has been violated. The argument is the rpc index. |
||
temperatureThresholdViolationCleared | 1.3.6.1.4.1.47790.16 |
INFORMATIONAL: A temperature threshold violated has been cleared. The argument is the rpc index. |
||
currentThresholdViolation | 1.3.6.1.4.1.47790.17 |
WARNING: The preset current threshold has been violated. The argument is the rpc index. |
||
currentThresholdViolationCleared | 1.3.6.1.4.1.47790.18 |
INFORMATIONAL: A current threshold violation has been cleared. The argument is the rpc index. |
||
resetModulesEvent | 1.3.6.1.4.1.47790.19 |
WARNING: A reset modules (RM) command has been executed. |
||
resetModulesComplete | 1.3.6.1.4.1.47790.20 |
WARNING: A reset modules (RM) command has been completed. |
||
errorExecutingSNMPCommand | 1.3.6.1.4.1.47790.21 |
WARNING: unable to execute SNMP command. String contains reason and command. |
||
fileTransferComplete | 1.3.6.1.4.1.47790.22 |
INFORMATIONAL: file transfer to unit complete. |
||
userTerminated | 1.3.6.1.4.1.47790.23 |
WARNING: user terminated. Argument specifies user. |
||
voltageOverThresholdViolation | 1.3.6.1.4.1.47790.24 |
WARNING: Over voltage. Argument specifies rpc. |
||
voltageOverThresholdViolationCleared | 1.3.6.1.4.1.47790.25 |
INFORMATIONAL: Over voltage cleared. Argument specifies rpc. |
||
voltageUnderThresholdViolation | 1.3.6.1.4.1.47790.26 |
WARNING: Under voltage. Argument specifies rpc. |
||
voltageUnderThresholdViolationCleared | 1.3.6.1.4.1.47790.27 |
INFORMATIONAL: Under voltage cleared. Argument specifies rpc. |
||
circuitBreakerAlarm | 1.3.6.1.4.1.47790.28 |
WARNING: Circuit breaker is blown. Argument specifies rpc. |
||
rpcFailureAlarm | 1.3.6.1.4.1.47790.29 |
WARNING: Unable to communicate to an RPC. Argument specifies port number of RPC. |
||
userDeleted | 1.3.6.1.4.1.47790.30 |
INFORMATIONAL: The specified user has logged in. |
||
warningThresholdViolation | 1.3.6.1.4.1.47790.31 |
|
||
warningThresholdViolationClear | 1.3.6.1.4.1.47790.32 |
|
||
emergencyThresholdViolation | 1.3.6.1.4.1.47790.33 |
|
||
emergencyThresholdViolationClear | 1.3.6.1.4.1.47790.34 |
|
||
circuitBreakerAlarmClearTrap | 1.3.6.1.4.1.47790.35 |
Circuit breaker has been reset. Argument specifies rpc. |
||
currentUnderThresholdViolation | 1.3.6.1.4.1.47790.36 |
WARNING: Low current. Argument specifies rpc. |
||
currentUnderThresholdViolationCleared | 1.3.6.1.4.1.47790.37 |
INFORMATIONAL: Low current cleared. Argument specifies rpc. |
||
voltageSourceChangeAlarm | 1.3.6.1.4.1.47790.38 |
WARNING: RPC voltage source has changed. Arguments specify modules index, current voltage source, and count of number of times source has been switched. |
||
sensorTempThreshHiAlarmTrap | 1.3.6.1.4.1.47790.39 |
WARNING: Hi threshold exceeded. Arguments specify module, sensor number |
||
sensorTempThreshHiAlarmClearedTrap | 1.3.6.1.4.1.47790.40 |
WARNING: Hi threshold alarm cleared. Arguments specify module, sensor number |
||
sensorTempThreshLoAlarmTrap | 1.3.6.1.4.1.47790.41 |
WARNING: Lo threshold alarm cleared. Arguments specify module, sensor number |
||
sensorTempThreshLoAlarmClearedTrap | 1.3.6.1.4.1.47790.42 |
WARNING: Lo threshold alarm cleared. Arguments specify module, sensor number |
||
sensorStateChangeTrap | 1.3.6.1.4.1.47790.43 |
WARNING: Sensor state (contact, detector, etc) has changed. Arguments specify module, sensor number |
||
configChangeSensor | 1.3.6.1.4.1.47790.44 |
WARNING: The specified environmental sensor has changed configuration. |
||
sensorTypeChange | 1.3.6.1.4.1.47790.45 |
WARNING: The specified environmental sensor is now a different type. |