BTI7800-EQUIPMENT-MIB: View SNMP OID List / Download MIB
VENDOR: BTI PHOTONIC SYSTEMS
Home | MIB: BTI7800-EQUIPMENT-MIB | |||
---|---|---|---|---|
Download as: |
Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
|
|||
Object Name | OID | Type | Access | Info |
bTI7800_EQUIPMENT_MIB | 1.3.6.1.4.1.18070.2.9.3.1 |
This YANG module provides the managed object definitions for operations, administration and management of the BTI Systems Atlas system. The current version of the Atlas module includes these sub-modules: types - definition of commonly used types system - configuration and status of system-wide attributes in addition to those defined by the ietf-system module equipment - configuration and status of provisioned and inventoried equipment logging - configuration of remote logging sinks, enabling the trace levels for the modules and actions pertaining to log notif - notification-related data conditions - retrieval of active alarms and conditions statistics - retrieval of current and historical statistics and performance monitoring counts and values debug - retrieval of debug information for all sub system |
||
chassisTable | 1.3.6.1.4.1.18070.2.9.3.1.1 | no-access |
System components (chassis, module, BIC, transceiver, preamplifier, etc) |
|
1.3.6.1.4.1.18070.2.9.3.1.1.1 | no-access | |||
chassisName | 1.3.6.1.4.1.18070.2.9.3.1.1.1.1 | string | no-access | |
chassisType | 1.3.6.1.4.1.18070.2.9.3.1.1.1.2 | chassistype | read-write |
Type of chassis based on [PamS] number of backplane slots |
chassisPEC | 1.3.6.1.4.1.18070.2.9.3.1.1.1.3 | string | read-write |
Product equipment code assigned by BTI |
chassisAdminStatus | 1.3.6.1.4.1.18070.2.9.3.1.1.1.4 | integer | read-write |
Administrative Status of the chassis Enumeration: 'down': 2, 'testing': 3, 'up': 1. |
chassisCustom1 | 1.3.6.1.4.1.18070.2.9.3.1.1.1.5 | string | read-write |
Customizable textual field for operator's use |
chassisCustom2 | 1.3.6.1.4.1.18070.2.9.3.1.1.1.6 | string | read-write |
Customizable textual field for operator's use |
chassisCustom3 | 1.3.6.1.4.1.18070.2.9.3.1.1.1.7 | string | read-write |
Customizable textual field for operator's use |
chassisOperationalStatus | 1.3.6.1.4.1.18070.2.9.3.1.1.1.8 | integer | read-only |
The operational status of the equipment item Enumeration: 'dormant': 5, 'lowerLayerDown': 7, 'unknown': 0, 'testing': 3, 'up': 1, 'down': 2, 'notPresent': 6. |
chassisLocation | 1.3.6.1.4.1.18070.2.9.3.1.1.1.9 | string | read-write |
The physical location of the chassis |
moduleTable | 1.3.6.1.4.1.18070.2.9.3.1.2 | no-access |
The module type and location |
|
1.3.6.1.4.1.18070.2.9.3.1.2.1 | no-access | |||
moduleName | 1.3.6.1.4.1.18070.2.9.3.1.2.1.1 | string | no-access | |
modulePEC | 1.3.6.1.4.1.18070.2.9.3.1.2.1.2 | string | read-write |
Product equipment code assigned by BTI |
moduleAdminStatus | 1.3.6.1.4.1.18070.2.9.3.1.2.1.3 | integer | read-write |
Administrative Status of the chassis Enumeration: 'down': 2, 'testing': 3, 'up': 1. |
moduleCustom1 | 1.3.6.1.4.1.18070.2.9.3.1.2.1.4 | string | read-write |
Customizable textual field for operator's use |
moduleCustom2 | 1.3.6.1.4.1.18070.2.9.3.1.2.1.5 | string | read-write |
Customizable textual field for operator's use |
moduleCustom3 | 1.3.6.1.4.1.18070.2.9.3.1.2.1.6 | string | read-write |
Customizable textual field for operator's use |
moduleOperationalStatus | 1.3.6.1.4.1.18070.2.9.3.1.2.1.7 | integer | read-only |
The operational status of the equipment item Enumeration: 'dormant': 5, 'lowerLayerDown': 7, 'unknown': 0, 'testing': 3, 'up': 1, 'down': 2, 'notPresent': 6. |
moduleType | 1.3.6.1.4.1.18070.2.9.3.1.2.1.8 | ufmtype | read-write |
Type of ufm based on msa and BIC and switching |
msaXcvrTable | 1.3.6.1.4.1.18070.2.9.3.1.3 | no-access |
The transceiver type and location |
|
1.3.6.1.4.1.18070.2.9.3.1.3.1 | no-access | |||
msaXcvrName | 1.3.6.1.4.1.18070.2.9.3.1.3.1.1 | string | no-access | |
msaXcvrPEC | 1.3.6.1.4.1.18070.2.9.3.1.3.1.2 | string | read-write |
Product equipment code assigned by BTI |
msaXcvrAdminStatus | 1.3.6.1.4.1.18070.2.9.3.1.3.1.3 | integer | read-write |
Administrative Status of the chassis Enumeration: 'down': 2, 'testing': 3, 'up': 1. |
msaXcvrCustom1 | 1.3.6.1.4.1.18070.2.9.3.1.3.1.4 | string | read-write |
Customizable textual field for operator's use |
msaXcvrCustom2 | 1.3.6.1.4.1.18070.2.9.3.1.3.1.5 | string | read-write |
Customizable textual field for operator's use |
msaXcvrCustom3 | 1.3.6.1.4.1.18070.2.9.3.1.3.1.6 | string | read-write |
Customizable textual field for operator's use |
msaXcvrOperationalStatus | 1.3.6.1.4.1.18070.2.9.3.1.3.1.7 | integer | read-only |
The operational status of the equipment item Enumeration: 'dormant': 5, 'lowerLayerDown': 7, 'unknown': 0, 'testing': 3, 'up': 1, 'down': 2, 'notPresent': 6. |
msaXcvrOpticalFormat | 1.3.6.1.4.1.18070.2.9.3.1.3.1.8 | integer | read-write |
Transceiver format fixed or tunable Enumeration: 'none': 7, 'tunableX2': 6, 'fixedX1': 0, 'tunableX1': 3, 'tunableX10': 5, 'tunableX4': 4, 'fixedX4': 1, 'fixedX10': 2. |
bicTable | 1.3.6.1.4.1.18070.2.9.3.1.4 | no-access |
A BTI interface card location |
|
1.3.6.1.4.1.18070.2.9.3.1.4.1 | no-access | |||
bicName | 1.3.6.1.4.1.18070.2.9.3.1.4.1.1 | string | no-access | |
bicPEC | 1.3.6.1.4.1.18070.2.9.3.1.4.1.2 | string | read-write |
Product equipment code assigned by BTI |
bicAdminStatus | 1.3.6.1.4.1.18070.2.9.3.1.4.1.3 | integer | read-write |
Administrative Status of the chassis Enumeration: 'down': 2, 'testing': 3, 'up': 1. |
bicCustom1 | 1.3.6.1.4.1.18070.2.9.3.1.4.1.4 | string | read-write |
Customizable textual field for operator's use |
bicCustom2 | 1.3.6.1.4.1.18070.2.9.3.1.4.1.5 | string | read-write |
Customizable textual field for operator's use |
bicCustom3 | 1.3.6.1.4.1.18070.2.9.3.1.4.1.6 | string | read-write |
Customizable textual field for operator's use |
bicOperationalStatus | 1.3.6.1.4.1.18070.2.9.3.1.4.1.7 | integer | read-only |
The operational status of the equipment item Enumeration: 'dormant': 5, 'lowerLayerDown': 7, 'unknown': 0, 'testing': 3, 'up': 1, 'down': 2, 'notPresent': 6. |
bicType | 1.3.6.1.4.1.18070.2.9.3.1.4.1.8 | bictype | read-write |
12x SFP+ or 1x CFP or 3x QSFP or 1x QSFP28 |
xcvrTable | 1.3.6.1.4.1.18070.2.9.3.1.5 | no-access |
The transceiver type and location |
|
1.3.6.1.4.1.18070.2.9.3.1.5.1 | no-access | |||
xcvrName | 1.3.6.1.4.1.18070.2.9.3.1.5.1.1 | string | no-access | |
xcvrPEC | 1.3.6.1.4.1.18070.2.9.3.1.5.1.2 | string | read-write |
Product equipment code assigned by BTI |
xcvrAdminStatus | 1.3.6.1.4.1.18070.2.9.3.1.5.1.3 | integer | read-write |
Administrative Status of the chassis Enumeration: 'down': 2, 'testing': 3, 'up': 1. |
xcvrCustom1 | 1.3.6.1.4.1.18070.2.9.3.1.5.1.4 | string | read-write |
Customizable textual field for operator's use |
xcvrCustom2 | 1.3.6.1.4.1.18070.2.9.3.1.5.1.5 | string | read-write |
Customizable textual field for operator's use |
xcvrCustom3 | 1.3.6.1.4.1.18070.2.9.3.1.5.1.6 | string | read-write |
Customizable textual field for operator's use |
xcvrOperationalStatus | 1.3.6.1.4.1.18070.2.9.3.1.5.1.7 | integer | read-only |
The operational status of the equipment item Enumeration: 'dormant': 5, 'lowerLayerDown': 7, 'unknown': 0, 'testing': 3, 'up': 1, 'down': 2, 'notPresent': 6. |
xcvrOpticalFormat | 1.3.6.1.4.1.18070.2.9.3.1.5.1.8 | integer | read-write |
Transceiver format fixed or tunable Enumeration: 'none': 7, 'tunableX2': 6, 'fixedX1': 0, 'tunableX1': 3, 'tunableX10': 5, 'tunableX4': 4, 'fixedX4': 1, 'fixedX10': 2. |
preamplifierTable | 1.3.6.1.4.1.18070.2.9.3.1.6 | no-access |
The pluggable preamplifier type and location |
|
1.3.6.1.4.1.18070.2.9.3.1.6.1 | no-access | |||
preamplifierName | 1.3.6.1.4.1.18070.2.9.3.1.6.1.1 | string | no-access | |
preamplifierPEC | 1.3.6.1.4.1.18070.2.9.3.1.6.1.2 | string | read-write |
Product equipment code assigned by BTI |
preamplifierAdminStatus | 1.3.6.1.4.1.18070.2.9.3.1.6.1.3 | integer | read-write |
Administrative Status of the chassis Enumeration: 'down': 2, 'testing': 3, 'up': 1. |
preamplifierCustom1 | 1.3.6.1.4.1.18070.2.9.3.1.6.1.4 | string | read-write |
Customizable textual field for operator's use |
preamplifierCustom2 | 1.3.6.1.4.1.18070.2.9.3.1.6.1.5 | string | read-write |
Customizable textual field for operator's use |
preamplifierCustom3 | 1.3.6.1.4.1.18070.2.9.3.1.6.1.6 | string | read-write |
Customizable textual field for operator's use |
preamplifierOperationalStatus | 1.3.6.1.4.1.18070.2.9.3.1.6.1.7 | integer | read-only |
The operational status of the equipment item Enumeration: 'dormant': 5, 'lowerLayerDown': 7, 'unknown': 0, 'testing': 3, 'up': 1, 'down': 2, 'notPresent': 6. |