Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
 neCommon 1.3.6.1.4.1.7501.1.1.1
     neType 1.3.6.1.4.1.7501.1.1.1.1 displaystring read-only
Type of NE
     neDescription 1.3.6.1.4.1.7501.1.1.1.2 displaystring read-only
The description of the NE.
     neLocationStreet 1.3.6.1.4.1.7501.1.1.1.3 displaystring read-write
Location Street of Network Element. Writable size depends on net element controller, default 32
     neLocationCity 1.3.6.1.4.1.7501.1.1.1.4 displaystring read-write
Location City of Network Element. Writable size depends on net element controller, default 32
     neObsolete_UsingAPS 1.3.6.1.4.1.7501.1.1.1.5 truthvalue read-only
This parameter is obsolete.
     neObsolete_APSMode 1.3.6.1.4.1.7501.1.1.1.6 integer read-write
This parameter is obsolete.
     neObsolete_CommonSubrackWidth 1.3.6.1.4.1.7501.1.1.1.8 integer read-only
This parameter is obsolete. (The width of the Subracks)
     neObsolete_CommonSubrackNumber 1.3.6.1.4.1.7501.1.1.1.9 integer read-only
This parameter is obsolete. (The number of Subracks)
     neObsolete_NumberModul 1.3.6.1.4.1.7501.1.1.1.10 integer read-only
This parameter is obsolete. (Current number of entries in the Modul table)
     neObsolete_UsingRevertiveMode 1.3.6.1.4.1.7501.1.1.1.11 truthvalue read-only
This parameter is obsolete.
     neObsolete_RevertiveMode 1.3.6.1.4.1.7501.1.1.1.12 integer read-write
This parameter is obsolete.
     neObsolete_InitPhase 1.3.6.1.4.1.7501.1.1.1.13 integer read-only
This parameter is obsolete.
     neObsolete_PredecessorRedundantPath 1.3.6.1.4.1.7501.1.1.1.14 ipaddress read-write
This parameter is obsolete.
     neObsolete_PredecessorNominalPath 1.3.6.1.4.1.7501.1.1.1.15 ipaddress read-write
This parameter is obsolete.
     neModuleTable 1.3.6.1.4.1.7501.1.1.1.16 no-access
Table containing information about each Module.
           neModuleEntry 1.3.6.1.4.1.7501.1.1.1.16.1 no-access
List of information about each Module.
               neModuleNESlot 1.3.6.1.4.1.7501.1.1.1.16.1.1 neslotvalue read-only
Slot number IMPORTANT NOTE: this is a not a physical slot within a module rack, but an assigned slot ID that uniquely identifies each module including non subrack based modules as 19 inch modules
               neModuleSubrack 1.3.6.1.4.1.7501.1.1.1.16.1.2 integer read-only
Subrack number in which the module is equiped (1 .. N). A value of 0 means: No subrack number
               neModuleModelName 1.3.6.1.4.1.7501.1.1.1.16.1.3 displaystring read-only
Module model name
               neModuleMibLink 1.3.6.1.4.1.7501.1.1.1.16.1.4 object identifier read-only
Defines the link to the OID of the equiped module
               neModuleSubrackSlot 1.3.6.1.4.1.7501.1.1.1.16.1.5 integer read-only
Slot number within subrack in which the module is equiped (1 .. N). A value of 0 means: No slot number
               neModuleSlotUnitsUsed 1.3.6.1.4.1.7501.1.1.1.16.1.6 integer read-only
For modules of type 'housing19inch(4)' this parameter specfifies the number of 19 inch height units used. For all other module types the number of slots within subrack which the module occupies.
               neModuleSlotRackDetection 1.3.6.1.4.1.7501.1.1.1.16.1.7 integer read-only
Reports the state of modules slot and rack hardware detection. Enumeration: 'supported': 2, 'notSupported': 1, 'detectionError': 3.
               neModuleHousingType 1.3.6.1.4.1.7501.1.1.1.16.1.8 integer read-only
Module housing type Enumeration: 'housing2G6': 3, 'housingBk': 2, 'housingUnknownOrDefault': 1, 'housing19inch': 4.
               neModuleFirmwareVersion 1.3.6.1.4.1.7501.1.1.1.16.1.9 displaystring read-only
Module firmware version
               neModuleHardwareVersion 1.3.6.1.4.1.7501.1.1.1.16.1.10 displaystring read-only
Module hardware version
               neModuleDateOfProduction 1.3.6.1.4.1.7501.1.1.1.16.1.11 displaystring read-only
Module date of production, possible formats: - empty string -> no data defined - YYYY -> only the year of production is defined - YYYY-MM-DD -> full date of production is defined
               neModuleSerialNumber 1.3.6.1.4.1.7501.1.1.1.16.1.12 displaystring read-only
Module serial number
               neModuleArticleNumber 1.3.6.1.4.1.7501.1.1.1.16.1.13 displaystring read-only
Module article number
               neModuleCustomerCode 1.3.6.1.4.1.7501.1.1.1.16.1.14 displaystring read-only
Customer specific article code
               neModuleAliasName 1.3.6.1.4.1.7501.1.1.1.16.1.15 displaystring read-write
Module alias name
               neModuleUserdata 1.3.6.1.4.1.7501.1.1.1.16.1.16 displaystring read-write
Module user data
               neModuleReset 1.3.6.1.4.1.7501.1.1.1.16.1.17 truthvalue read-write
Resets the module if this parameter is written to true(1).
               neModuleLedBlink 1.3.6.1.4.1.7501.1.1.1.16.1.18 truthvalue read-write
Writing this variable to true(1) lets the device's modul LED blink green for 10 seconds. Writing this variable to false(2) stops blinking at once. This variable always returns false(2) on read requests
 neStates 1.3.6.1.4.1.7501.1.1.2
     neStatesObsolete_TrapDisable 1.3.6.1.4.1.7501.1.1.2.1 perceivedseverityvalue read-only
This parameter is obsolete.
     neStatesObsolete_TerminalConnected 1.3.6.1.4.1.7501.1.1.2.2 perceivedseverityvalue read-only
This parameter is obsolete.
     neStatesObsolete_Isolated 1.3.6.1.4.1.7501.1.1.2.4 perceivedseverityvalue read-only
This parameter is obsolete.
     neStatesObsolete_ResetModullist 1.3.6.1.4.1.7501.1.1.2.5 perceivedseverityvalue read-only
This parameter is obsolete.
     neStatesObsolete_Redundant 1.3.6.1.4.1.7501.1.1.2.6 perceivedseverityvalue read-only
This parameter is obsolete.
     neStatesObsolete_ActivateRedundantPath 1.3.6.1.4.1.7501.1.1.2.7 perceivedseverityvalue read-only
This parameter is obsolete.
     neStatesObsolete_AutoOff 1.3.6.1.4.1.7501.1.1.2.8 perceivedseverityvalue read-only
This parameter is obsolete.
 neConfig 1.3.6.1.4.1.7501.1.1.3
     neConfigObsolete_NEtype 1.3.6.1.4.1.7501.1.1.3.1 integer read-write
This parameter is obsolete.
     neConfigObsolete_IPaddress 1.3.6.1.4.1.7501.1.1.3.2 ipaddress read-write
This parameter is obsolete.
     neConfigObsolete_Alarmdelay 1.3.6.1.4.1.7501.1.1.3.3 integer read-write
This parameter is obsolete.
     neConfigDeprecated_MinTrapInterval 1.3.6.1.4.1.7501.1.1.3.4 integer read-write
This parameter is deprecated. (The minimum waiting time between two traps. Only used for HMS070 over RS232 interface)
     neConfigDeprecated_MaxTrapLifetime 1.3.6.1.4.1.7501.1.1.3.5 integer read-write
This parameter is deprecated. (The maximum lifetime of a trap. Only used for HMS070 over RS232 interface)
 neControl 1.3.6.1.4.1.7501.1.1.4
     neControlTrapDisable 1.3.6.1.4.1.7501.1.1.4.1 truthvalue read-write
All traps and notifications for the whole NE are disabled: true(1) or enabled: false(2)
     neControlResetModullist 1.3.6.1.4.1.7501.1.1.4.2 truthvalue read-write
This command removes all disconnected (not responding) modules from the module list.
     neControlObsolete_SetDefaultAPS 1.3.6.1.4.1.7501.1.1.4.3 truthvalue read-write
This parameter is obsolete.
   neSynchronizeEvent 1.3.6.1.4.1.7501.1.10.1
The SNMP trap that is generated when data on LMT must get actualized.