Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
 bes 1.3.6.1.4.1.7501.1.2.114
         besCommon 1.3.6.1.4.1.7501.1.2.114.1
             besCommonNumberOfModules 1.3.6.1.4.1.7501.1.2.114.1.1 integer read-only
Number of modules in table.
             besCommonTable 1.3.6.1.4.1.7501.1.2.114.1.2 no-access
The table contains all modules of the BES-type in the NE
                 besCommonEntry 1.3.6.1.4.1.7501.1.2.114.1.2.1 no-access
Common-Values for a module.
                     besNESlot 1.3.6.1.4.1.7501.1.2.114.1.2.1.1 neslotvalue read-only
The slot number of the chassis for which this entry contains management information.
                     besCommonType 1.3.6.1.4.1.7501.1.2.114.1.2.1.2 displaystring read-only
The type of physical module. modSlotEmpty indicates an empty slot. A Value of modSlotUnknown indicates that the type of module is unknown.
                     besCommonDescr 1.3.6.1.4.1.7501.1.2.114.1.2.1.3 displaystring read-write
A textual description of the module. If not available, this Value should be set to a zero length string.
                     besCommonFirmwareId 1.3.6.1.4.1.7501.1.2.114.1.2.1.4 displaystring read-only
The firmware Id of the module.
                     besCommonModuleWidth 1.3.6.1.4.1.7501.1.2.114.1.2.1.5 modulewidthvalue read-only
The width of the module in multiples of slots (1, 2, ...)
         besStates 1.3.6.1.4.1.7501.1.2.114.2
             besStatesTable 1.3.6.1.4.1.7501.1.2.114.2.1 no-access
                 besStatesEntry 1.3.6.1.4.1.7501.1.2.114.2.1.1 no-access
Alarms for a module.
                     besStatesBootloader 1.3.6.1.4.1.7501.1.2.114.2.1.1.1 perceivedseverityvalue read-only
The device is running in bootloader mode without a legal application software.
                     besStatesCommLoss 1.3.6.1.4.1.7501.1.2.114.2.1.1.2 perceivedseverityvalue read-only
The NEC has lost the connection to the device. Reason may be a removed or defective device. Note that this state is set by the NEC and not by the device
                     besStatesTemperatureLow 1.3.6.1.4.1.7501.1.2.114.2.1.1.3 perceivedseverityvalue read-only
Device temperature low
                     besStatesTemperatureHigh 1.3.6.1.4.1.7501.1.2.114.2.1.1.4 perceivedseverityvalue read-only
Device temperature high
                     besStatesInputVoltageLow 1.3.6.1.4.1.7501.1.2.114.2.1.1.5 perceivedseverityvalue read-only
Input supply voltage low
                     besStatesInputVoltageHigh 1.3.6.1.4.1.7501.1.2.114.2.1.1.6 perceivedseverityvalue read-only
Input supply voltage high
         besConfiguration 1.3.6.1.4.1.7501.1.2.114.3
             besConfigurationTable 1.3.6.1.4.1.7501.1.2.114.3.1 no-access
                 besConfigurationEntry 1.3.6.1.4.1.7501.1.2.114.3.1.1 no-access
                     besConfigNESlotWrite 1.3.6.1.4.1.7501.1.2.114.3.1.1.1 neslotwritevalue read-write
By writing this variable a slot can be assigned for devices that dont support hardware slot detection. Reading '-1' means that the slot position is NOT writable.
                     besConfigConfigurationIndex 1.3.6.1.4.1.7501.1.2.114.3.1.1.2 integer read-write
Index of the active configuration (1..besDisplayNumberOfConfigs)
                     besConfigConfiguration 1.3.6.1.4.1.7501.1.2.114.3.1.1.3 displaystring read-only
Description of the active configuration
         besControl 1.3.6.1.4.1.7501.1.2.114.4
             besControlTable 1.3.6.1.4.1.7501.1.2.114.4.1 no-access
                 besControlEntry 1.3.6.1.4.1.7501.1.2.114.4.1.1 no-access
Alarms for a module.
                     besControlReset 1.3.6.1.4.1.7501.1.2.114.4.1.1.1 truthvalue read-write
Reset the module.
                     besControlModuleLedBlink 1.3.6.1.4.1.7501.1.2.114.4.1.1.2 truthvalue read-write
Writing this variable to true(1) lets the device's modul LED blink green for 10 seconds. Writing this variable to false(2) stbes blinking at once. This variable always returns false(2) on read requests
         besMeasuringValues 1.3.6.1.4.1.7501.1.2.114.5
             besMeasuringValuesTable 1.3.6.1.4.1.7501.1.2.114.5.1 no-access
                 besMeasuringValuesEntry 1.3.6.1.4.1.7501.1.2.114.5.1.1 no-access
Common-Values for a module.
                     besTemperatureLoLo 1.3.6.1.4.1.7501.1.2.114.5.1.1.1 integer read-only
Device temperature low alarm threshold in 0.1 celsius degrees.
                     besTemperatureLo 1.3.6.1.4.1.7501.1.2.114.5.1.1.2 integer read-only
Device temperature low warning threshold in 0.1 celsius degrees.
                     besTemperatureValue 1.3.6.1.4.1.7501.1.2.114.5.1.1.3 integer read-only
Device temperature in 0.1 celsius degrees.
                     besTemperatureHi 1.3.6.1.4.1.7501.1.2.114.5.1.1.4 integer read-only
Device temperature high warning threshold in 0.1 celsius degrees.
                     besTemperatureHiHi 1.3.6.1.4.1.7501.1.2.114.5.1.1.5 integer read-only
Device temperature high alarm threshold in 0.1 celsius degrees.
                     besInputVoltageLoLo 1.3.6.1.4.1.7501.1.2.114.5.1.1.6 integer read-only
The input supply voltage low alarm threshold in steps of 0.1 Volts.
                     besInputVoltageLo 1.3.6.1.4.1.7501.1.2.114.5.1.1.7 integer read-only
The input supply voltage low warning threshold in steps of 0.1 Volts.
                     besInputVoltageValue 1.3.6.1.4.1.7501.1.2.114.5.1.1.8 integer read-only
The input supply voltage in steps of 0.1 Volts. Input supply voltage nominal value, see 'besDisplayInputVoltageNominal'
                     besInputVoltageHi 1.3.6.1.4.1.7501.1.2.114.5.1.1.9 integer read-only
The input supply voltage high warning threshold in steps of 0.1 Volts.
                     besInputVoltageHiHi 1.3.6.1.4.1.7501.1.2.114.5.1.1.10 integer read-only
The input supply voltage high alarm threshold in steps of 0.1 Volts.
         besDisplay 1.3.6.1.4.1.7501.1.2.114.6
             besDisplayTable 1.3.6.1.4.1.7501.1.2.114.6.1 no-access
                 besDisplayEntry 1.3.6.1.4.1.7501.1.2.114.6.1.1 no-access
                     besDisplayNumberOfPorts 1.3.6.1.4.1.7501.1.2.114.6.1.1.1 integer read-only
The number of ports
                     besDisplayInputVoltageNominal 1.3.6.1.4.1.7501.1.2.114.6.1.1.2 integer read-only
The nominal value of input voltage in 0.1 V units.
                     besDisplayNumberOfConfigs 1.3.6.1.4.1.7501.1.2.114.6.1.1.3 integer read-only
The number of different configurations supplied
                     besDisplayConfiguration1 1.3.6.1.4.1.7501.1.2.114.6.1.1.4 displaystring read-only
Description of configuration no. #1
                     besDisplayConfiguration2 1.3.6.1.4.1.7501.1.2.114.6.1.1.5 displaystring read-only
Description of configuration no. #2
                     besDisplayConfiguration3 1.3.6.1.4.1.7501.1.2.114.6.1.1.6 displaystring read-only
Description of configuration no. #3
                     besDisplayConfiguration4 1.3.6.1.4.1.7501.1.2.114.6.1.1.7 displaystring read-only
Description of configuration no. #4
                     besDisplayConfiguration5 1.3.6.1.4.1.7501.1.2.114.6.1.1.8 displaystring read-only
Description of configuration no. #5
                     besDisplayConfiguration6 1.3.6.1.4.1.7501.1.2.114.6.1.1.9 displaystring read-only
Description of configuration no. #6
                     besDisplayConfiguration7 1.3.6.1.4.1.7501.1.2.114.6.1.1.10 displaystring read-only
Description of configuration no. #7
                     besDisplayConfiguration8 1.3.6.1.4.1.7501.1.2.114.6.1.1.11 displaystring read-only
Description of configuration no. #8
                     besDisplayConfiguration9 1.3.6.1.4.1.7501.1.2.114.6.1.1.12 displaystring read-only
Description of configuration no. #9
                     besDisplayConfiguration10 1.3.6.1.4.1.7501.1.2.114.6.1.1.13 displaystring read-only
Description of configuration no. #10
                     besDisplayConfiguration11 1.3.6.1.4.1.7501.1.2.114.6.1.1.14 displaystring read-only
Description of configuration no. #11
                     besDisplayConfiguration12 1.3.6.1.4.1.7501.1.2.114.6.1.1.15 displaystring read-only
Description of configuration no. #12
                     besDisplayConfiguration13 1.3.6.1.4.1.7501.1.2.114.6.1.1.16 displaystring read-only
Description of configuration no. #13
                     besDisplayConfiguration14 1.3.6.1.4.1.7501.1.2.114.6.1.1.17 displaystring read-only
Description of configuration no. #14
                     besDisplayConfiguration15 1.3.6.1.4.1.7501.1.2.114.6.1.1.18 displaystring read-only
Description of configuration no. #15
                     besDisplayConfiguration16 1.3.6.1.4.1.7501.1.2.114.6.1.1.19 displaystring read-only
Description of configuration no. #16
         besDisplayPorts 1.3.6.1.4.1.7501.1.2.114.56
               besDisplayPortsTable 1.3.6.1.4.1.7501.1.2.114.56.1 no-access
                   besDisplayPortsEntry 1.3.6.1.4.1.7501.1.2.114.56.1.1 no-access
                       besDisplayPortsPortIndex 1.3.6.1.4.1.7501.1.2.114.56.1.1.1 integer read-only
Port index (1..besDisplayNumberOfPorts)
                       besDisplayPortsPortName 1.3.6.1.4.1.7501.1.2.114.56.1.1.2 displaystring read-only
Port name
                       besDisplayPortsType 1.3.6.1.4.1.7501.1.2.114.56.1.1.3 porttype read-only
Port type
                       besDisplayPortsLinkState 1.3.6.1.4.1.7501.1.2.114.56.1.1.4 portlinkstate read-only
Port link status
                       besDisplayPortsStatus 1.3.6.1.4.1.7501.1.2.114.56.1.1.5 portstatus read-only
Port status
                       besDisplayPortsDuplexMode 1.3.6.1.4.1.7501.1.2.114.56.1.1.6 portduplexmode read-only
Port duplex mode
                       besDisplayPortsSpeed 1.3.6.1.4.1.7501.1.2.114.56.1.1.7 portspeed read-only
Port speed
                       besDisplayPortsFlowControl 1.3.6.1.4.1.7501.1.2.114.56.1.1.8 portflowcontrol read-only
Port speed
                       besDisplayPortsFiberTxDistance 1.3.6.1.4.1.7501.1.2.114.56.1.1.9 integer read-only
Port transmission distance in units of km (Fiber ports only)
                       besDisplayPortsFiberTxWavelen 1.3.6.1.4.1.7501.1.2.114.56.1.1.10 integer read-only
Port transmission wavelength in units of nm (Fiber ports only)
                       besDisplayPortsFiberRxWavelenMin 1.3.6.1.4.1.7501.1.2.114.56.1.1.11 integer read-only
Port minimum receive wavelength in units of nm (Fiber ports only)
                       besDisplayPortsFiberRxWavelenMax 1.3.6.1.4.1.7501.1.2.114.56.1.1.12 integer read-only
Port maximum receive wavelength in units of nm (Fiber ports only)
                       besDisplayPortsFiberSfpData 1.3.6.1.4.1.7501.1.2.114.56.1.1.13 displaystring read-only
Port SFP data text (Fiber ports only)