BIANCA-X8000-MIBSYS-MIB: View SNMP OID List / Download MIB

VENDOR: BINTEC COMMUNICATIONS GMBH


 Home MIB: BIANCA-X8000-MIBSYS-MIB
Download as:   

Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
 bintec 1.3.6.1.4.1.272
         bibo 1.3.6.1.4.1.272.4
             sys 1.3.6.1.4.1.272.4.17
                   x8 1.3.6.1.4.1.272.4.17.3
                       sysX8Config 1.3.6.1.4.1.272.4.17.3.1
                           sysX8ConfigPowerSupply1State 1.3.6.1.4.1.272.4.17.3.1.1 integer read-only
This variable shows the state of the power supply. Enumeration: 'fail': 4, 'running': 3, 'off': 2, 'missing': 1.
                           sysX8ConfigPowerSupply1Temp 1.3.6.1.4.1.272.4.17.3.1.2 integer read-only
This variable shows the actual power supply temperature in the unit Celsius.
                           sysX8ConfigPowerSupply1TempAlarmThreshold 1.3.6.1.4.1.272.4.17.3.1.3 integer read-write
Power supply 1 temperature threshold.
                           sysX8ConfigPowerSupply1TempAlarmTrap 1.3.6.1.4.1.272.4.17.3.1.4 integer read-only
If the power supply temperature raises above the threshold, a alarm trap is generated every 60 seconds. Enumeration: 'critical': 2, 'normal': 1.
                           sysX8ConfigPowerSupply2State 1.3.6.1.4.1.272.4.17.3.1.5 integer read-only
This variable show the the state of the power supply. Enumeration: 'fail': 4, 'running': 3, 'off': 2, 'missing': 1.
                           sysX8ConfigPowerSupply2Temp 1.3.6.1.4.1.272.4.17.3.1.6 integer read-only
This variable shows the actual power supply temperature in the unit Celsius.
                           sysX8ConfigPowerSupply2TempAlarmThreshold 1.3.6.1.4.1.272.4.17.3.1.7 integer read-write
Power supply 2 temperature threshold.
                           sysX8ConfigPowerSupply2TempAlarmTrap 1.3.6.1.4.1.272.4.17.3.1.8 integer read-only
If the power supply temperature raises above the threshold, a alarm trap is generated every 60 seconds. Enumeration: 'critical': 2, 'normal': 1.
                           sysX8ConfigFanControl 1.3.6.1.4.1.272.4.17.3.1.9 integer read-write
This variable defines automatic fan control. In mode 'auto' the fans are automatically adjusted depending on the current temperature. In mode 'high' all fans remain at maximum speed. Enumeration: 'high': 2, 'auto': 1.
                           sysX8ConfigFanVersion 1.3.6.1.4.1.272.4.17.3.1.10 displaystring read-only
This variable shows the firmware version of the fan unit.
                           sysX8ConfigFan1 1.3.6.1.4.1.272.4.17.3.1.11 integer read-only
This variable shows the current turning speed.
                           sysX8ConfigFan2 1.3.6.1.4.1.272.4.17.3.1.12 integer read-only
This variable shows the current turning speed.
                           sysX8ConfigFan3 1.3.6.1.4.1.272.4.17.3.1.13 integer read-only
This variable shows the current turning speed.
                           sysX8ConfigFan4 1.3.6.1.4.1.272.4.17.3.1.14 integer read-only
This variable shows the current turning speed.
                       sysX8Traps 1.3.6.1.4.1.272.4.17.3.2
                             sysX8TrapPowerSupply1Missing 1.3.6.1.4.1.272.4.17.3.20.1
This trap signifies that the power supply 1 has been removed
                             sysX8TrapPowerSupply1PowerOff 1.3.6.1.4.1.272.4.17.3.20.2
This trap signifies that the power supply 1 has no power-good signal (no power input)
                             sysX8TrapPowerSupply1PowerFail 1.3.6.1.4.1.272.4.17.3.20.3
This trap signifies that the power supply 1 has been in the failure (bad DC output)
                             sysX8TrapPowerSupply1PowerGood 1.3.6.1.4.1.272.4.17.3.20.4
This trap signifies that the power supply 1 is running (supplying power)
                             sysX8TrapPowerSupply1TempCritical 1.3.6.1.4.1.272.4.17.3.20.5
This trap signifies that the power supply 1 temperature raises above the critical alarm-threshold
                             sysX8TrapPowerSupply1TempOk 1.3.6.1.4.1.272.4.17.3.20.6
A normal power supply 1 temperature has been restored.
                             sysX8TrapPowerSupply2Missing 1.3.6.1.4.1.272.4.17.3.20.7
This trap signifies that the power supply 2 has been removed
                             sysX8TrapPowerSupply2PowerOff 1.3.6.1.4.1.272.4.17.3.20.8
This trap signifies that the power supply 2 has no power-good signal (no power input)
                             sysX8TrapPowerSupply2PowerFail 1.3.6.1.4.1.272.4.17.3.20.9
This trap signifies that the power supply 2 has been in the failure (bad DC output)
                             sysX8TrapPowerSupply2PowerGood 1.3.6.1.4.1.272.4.17.3.20.10
This trap signifies that the power supply 2 is running (supplying power)
                             sysX8TrapPowerSupply2TempCritical 1.3.6.1.4.1.272.4.17.3.20.11
This trap signifies that the power supply 2 temperature raises above the critical alarm-threshold
                             sysX8TrapPowerSupply2TempOk 1.3.6.1.4.1.272.4.17.3.20.12
A normal power supply 2 temperature has been restored.