BENU-CHASSIS-MIB: View SNMP OID List / Download MIB

VENDOR: BENU NETWORKS


 Home MIB: BENU-CHASSIS-MIB
Download as:   

Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
 benuChassisMIB 1.3.6.1.4.1.39406.1.1
Initial creation MIB module for Benu Networks Chassis. Copyright (C) 2001, 2008 by Benu Networks, Inc. All rights reserved.
     benuChassisNotifObjects 1.3.6.1.4.1.39406.1.1.0
         benuChassisPowerFailure 1.3.6.1.4.1.39406.1.1.0.1
A chassisPowerFailureTrap is generated when a Power Failure is detected in the system
         benuChassisFanFailureTrap 1.3.6.1.4.1.39406.1.1.0.2
A chassisFanFailureTrap is generated when a Fan Failure is detected in the system
         benuLinkUpTrap 1.3.6.1.4.1.39406.1.1.0.3
A proprietary Link Up Notification for all interfaces. This notification contains more details than the standard 'linkUp' notification in RFC 2863.
         benuLinkDownTrap 1.3.6.1.4.1.39406.1.1.0.4
A proprietary Link Down Notification for all interfaces. This notification contains more details than the standard 'linkDown' notification in RFC 2863.
         benuSensorCritical 1.3.6.1.4.1.39406.1.1.0.5
This notification signifies the transition of the sensor state from normal to critical.
         benuSensorNormal 1.3.6.1.4.1.39406.1.1.0.6
This notification signifies the transition of the sensor state from critical to normal.
         benuChassisPowerFault 1.3.6.1.4.1.39406.1.1.0.7
A chassisPowerFaultTrap is generated when a Power Failure is detected in the system
         benuChassisPowerRecovery 1.3.6.1.4.1.39406.1.1.0.8
A chassisPowerRecoveryTrap is generated when a failed Power supply recovery is detected in the system
         benuChassisPowerPresent 1.3.6.1.4.1.39406.1.1.0.9
A chassisPowerPresentTrap is generated when a redundant Power supply is inserted in the system
         benuChassisPowerAbsent 1.3.6.1.4.1.39406.1.1.0.10
A chassisPowerAbsentTrap is generated when a redundant Power supply is removed from the system
     benuChassisMIBObjects 1.3.6.1.4.1.39406.1.1.1
         benuChassisInfo 1.3.6.1.4.1.39406.1.1.1.1
             benuChassisType 1.3.6.1.4.1.39406.1.1.1.1.1 integer read-only
Chassis type. Enumeration: 'meg1200': 3, 'meg100': 1, 'meg400': 2, 'xMEG100': 5, 'meg50': 4, 'xMEG10': 6.
             benuChassisHwVersion 1.3.6.1.4.1.39406.1.1.1.1.2 displaystring read-only
Chassis hardware revision level, or an empty string if unavailable.
             benuChassisId 1.3.6.1.4.1.39406.1.1.1.1.3 displaystring read-only
Unique ID string. Defaults to chassis serial number if available, otherwise empty
             benuChassisNumOfSlots 1.3.6.1.4.1.39406.1.1.1.1.4 integer32 read-only
Number of slots in this chassis, or -1 if neither applicable nor determinable.
             benuChassisPowerTrapEnable 1.3.6.1.4.1.39406.1.1.1.1.5 integer read-write
This object controls SNMP traps for chassis Power Failure. If its value is set to enabled(1), then traps are generated. If the value is disabled(2), then traps are not generated. By default, this object has the value enabled(1). Enumeration: 'disabled': 2, 'enabled': 1.
             benuChassisFanTrapEnable 1.3.6.1.4.1.39406.1.1.1.1.6 integer read-write
This object controls SNMP traps for chassis Fan Failure. If its value is set to enabled(1), then traps are generated. If the value is disabled(2), then traps are not generated. By default, this object has the value enabled(1). Enumeration: 'disabled': 2, 'enabled': 1.
             benuChassisSensorTrapEnable 1.3.6.1.4.1.39406.1.1.1.1.7 integer read-write
This object controls SNMP traps for chassis senor Failure. If its value is set to enabled(1), then traps are generated. If the value is disabled(2), then traps are not generated. By default, this object has the value enabled(1). Enumeration: 'disabled': 2, 'enabled': 1.
             benuSysUpTimeAtLastChassisChange 1.3.6.1.4.1.39406.1.1.1.1.8 timeticks read-only
Time (in hundredths of a second) from the last cold start to the last change in the chassis' configuration. This value will be updated whenever the chassis experiences a change in the count, type, or slot position of a card in cardTable.
         benuCardInfo 1.3.6.1.4.1.39406.1.1.1.2
             benuCardTable 1.3.6.1.4.1.39406.1.1.1.2.1 no-access
Chassis card table.
                 benuCardEntry 1.3.6.1.4.1.39406.1.1.1.2.1.1 no-access
Chassis card table.
                     benuCardIndex 1.3.6.1.4.1.39406.1.1.1.2.1.1.1 unsigned32 no-access
Index into cardTable (not physical chassis slot number).
                     benuCardType 1.3.6.1.4.1.39406.1.1.1.2.1.1.2 integer read-only
Functional type of this card. Enumeration: 'rsm': 1, 'seFP': 4, 'inputOutputCard': 5, 'unknown': 0, 'shelfmgr': 3, 'switchMesh': 6, 'switchFabric': 2, 'xmeg': 7.
                     benuCardDescr 1.3.6.1.4.1.39406.1.1.1.2.1.1.3 displaystring read-only
Text description of this card.
                     benuCardSerial 1.3.6.1.4.1.39406.1.1.1.2.1.1.4 displaystring read-only
The serial number of this card, or zero if unavailable.
                     benuCardPartNumber 1.3.6.1.4.1.39406.1.1.1.2.1.1.5 displaystring read-only
The part number of this card, or an empty string if unavailable.
                     benuCardHwVersion 1.3.6.1.4.1.39406.1.1.1.2.1.1.6 displaystring read-only
Hardware revision level of this card, or an empty string if unavailable.
                     benuCardSwVersion 1.3.6.1.4.1.39406.1.1.1.2.1.1.7 displaystring read-only
Version of the firmware or microcode installed on this card, or an empty string if unavailable.
                     benuCardSlotNumber 1.3.6.1.4.1.39406.1.1.1.2.1.1.8 integer32 read-only
Slot number relative to the containing card or chassis, or -1 if neither applicable nor determinable.
                     benuCardRamSize 1.3.6.1.4.1.39406.1.1.1.2.1.1.9 integer32 read-only
Number of kilobytes of DRAM. A value -1 means not available / not applicable A value 0 means internal error.
                     benuCardPrimaryDiskSize 1.3.6.1.4.1.39406.1.1.1.2.1.1.10 integer32 read-only
Number of kilobytes of Disk Memory (SATA or Hard Disk). A value -1 means not available / not applicable. A value 0 means internal error.
                     benuCardSecondaryDiskSize 1.3.6.1.4.1.39406.1.1.1.2.1.1.11 integer32 read-only
Number of kilobytes of Disk Memory (SATA or Hard Disk). A value -1 means not available / not applicable. A value 0 means internal error.
                     benuCardOperStatus 1.3.6.1.4.1.39406.1.1.1.2.1.1.12 integer read-only
The operational status of the card. cardOperStatus is up when a card is recognized by the device and is enabled for operation. cardOperStatus is down if the card is not recognized by the device, or if it is not enabled for operation. cardOperStatus is standby if the card is enabled and acting as a standby slave. Intermediate stages (rom,flash,diag,boot,config) are also exposed. Enumeration: 'rom': 5, 'standby': 4, 'diag': 7, 'flash': 6, 'boot': 8, 'up': 2, 'down': 3, 'notSpecified': 1, 'config': 9.
         benuCardIfInfo 1.3.6.1.4.1.39406.1.1.1.3
             benuCardIfIndexTable 1.3.6.1.4.1.39406.1.1.1.3.1 no-access
Chassis card Interface table.
                 benuCardIfIndexEntry 1.3.6.1.4.1.39406.1.1.1.3.1.1 no-access
Chassis card table.
                     benuCardIfIndex 1.3.6.1.4.1.39406.1.1.1.3.1.1.1 unsigned32 no-access
matches RFC1213 ifTable IfIndex
                     benuCardIfName 1.3.6.1.4.1.39406.1.1.1.3.1.1.2 displaystring read-only
matches RFC1213 ifXTable IfName
                     benuCardIfPortNumber 1.3.6.1.4.1.39406.1.1.1.3.1.1.3 integer32 read-only
Chassis port number, unique per port on a given card if available.
                     benuCardIfSlotNumber 1.3.6.1.4.1.39406.1.1.1.3.1.1.4 integer32 read-only
Physical slot number of the card in the Chassis which contains this interface
                     benuCardIfLinkUpDownEnable 1.3.6.1.4.1.39406.1.1.1.3.1.1.5 integer read-write
This enables and disables the sending of the proprietary notifications 'benuLinkUpTrap' and 'benuLinkDownTrap' that provide more information than the standard link up and link down notifications. By default, these traps are disabled. Enumeration: 'disabled': 2, 'enabled': 1.
                     benuCardIfPortType 1.3.6.1.4.1.39406.1.1.1.3.1.1.6 integer read-only
This object is used to identify port types for a given card. Enumeration: 'ipGre': 5, 'bridge': 9, 'none': 0, 'lag': 15, 'gigaEthernet': 3, 'cable': 8, 'loopback': 13, 'tunnel': 4, 'ip': 10, 'vlan': 6, 'multiBindLastResort': 14, 'fastEthernet': 2, 'multiBind': 11, 'p2p': 12, 'l2tp': 7, 'max': 16, 'ethernet': 1.
                     benuCardIfBindName 1.3.6.1.4.1.39406.1.1.1.3.1.1.7 displaystring read-only
interface name which is bound to this port . This string will be empty if there is no interface bind to this port
                     benuCardIfEncapsulation 1.3.6.1.4.1.39406.1.1.1.3.1.1.8 displaystring read-only
The encapsulation method used by the port.
                     benuCardIfVirtualType 1.3.6.1.4.1.39406.1.1.1.3.1.1.9 integer read-only
This object is used to identify virtualized interfaces. Enumeration: 'virtual': 2, 'physical': 1.
         benuSensorInfo 1.3.6.1.4.1.39406.1.1.1.4
             benuSensorTable 1.3.6.1.4.1.39406.1.1.1.4.1 no-access
Chassis card table.
                 benuSensorEntry 1.3.6.1.4.1.39406.1.1.1.4.1.1 no-access
Chassis card table.
                     benuSensorCardIndex 1.3.6.1.4.1.39406.1.1.1.4.1.1.1 unsigned32 no-access
cardIndex of the card in the Chassis cardTable which contains this sensor.
                     benuSensorIndex 1.3.6.1.4.1.39406.1.1.1.4.1.1.2 unsigned32 no-access
Index into sensorTable.
                     benuSensorName 1.3.6.1.4.1.39406.1.1.1.4.1.1.3 displaystring read-only
Name of the sensor.
                     benuSensorType 1.3.6.1.4.1.39406.1.1.1.4.1.1.4 integer read-only
Type of the sensor. Enumeration: 'electicCurrent': 3, 'power': 5, 'temparature': 1, 'other': 0, 'fan': 4, 'voltage': 2.
                     benuSensorValue 1.3.6.1.4.1.39406.1.1.1.4.1.1.5 integer32 read-only
Current Value of this sensor. The unit types for different type of sensors: temparature -- celcius Fan -- rpm Volatage -- volts Electric Current -- amperes Power -- watts
                     benuSensorMinThresh 1.3.6.1.4.1.39406.1.1.1.4.1.1.6 integer32 read-only
Minimum threshold for this sensor.
                     benuSensorMaxThresh 1.3.6.1.4.1.39406.1.1.1.4.1.1.7 integer32 read-only
Maximum threshold for this sensor.
                     benuSensorState 1.3.6.1.4.1.39406.1.1.1.4.1.1.8 integer read-only
State of the sensor. Enumeration: 'other': 0, 'critical': 2, 'normal': 1.
                     benuSensorId 1.3.6.1.4.1.39406.1.1.1.4.1.1.9 integer32 read-only
Unique ID of the sensor.
         benuChassisGeneralInfo 1.3.6.1.4.1.39406.1.1.1.5
             benuSysUpTimeSinceLastConfigChange 1.3.6.1.4.1.39406.1.1.1.5.1 timeticks read-only
The time (in hundredths of a second) since the last configuration change in the system.
         benuFanInfo 1.3.6.1.4.1.39406.1.1.1.6
             benuFanTable 1.3.6.1.4.1.39406.1.1.1.6.1 no-access
Chassis Fan table.
                 benuFanEntry 1.3.6.1.4.1.39406.1.1.1.6.1.1 no-access
Chassis card table.
                     benuFanCardIndex 1.3.6.1.4.1.39406.1.1.1.6.1.1.1 unsigned32 no-access
cardIndex of the card in the Chassis cardTable which contains this Fan.
                     benuFanMaxSpeed 1.3.6.1.4.1.39406.1.1.1.6.1.1.2 unsigned32 read-only
Maximum expected speed of each Fan. This value is applicable to all Fans in the card. Units : The value range is from 0 to 100
                     benuFanCurSpeed 1.3.6.1.4.1.39406.1.1.1.6.1.1.3 unsigned32 read-only
Current speed of each Fan. This value is applicable to all Fans in the card. Units : The value range is from 0 to 100 and is less than or equal to benuFanMaxSpeed
                     benuFanStatus 1.3.6.1.4.1.39406.1.1.1.6.1.1.4 integer32 read-only
A value of -1 means Not available / Not applicable. The lower order 7 bits indicates status of 7 Fans. A bit value of one indicates FAN is non-operational. A bit value of zero indicates FAN is operational. Examples : (a) Value of 1 ( 0000 0001 ) indicates FAN #1 is non-operational. (b) Value of 9 ( 0000 1001 ) indicates FAN #1 and FAN #4 are non-operational. (c) Value of 73( 0100 1001 ) indicates FAN #1,FAN #4 and FAN #7 are non-operational.
         benuPowerSupplyInfo 1.3.6.1.4.1.39406.1.1.1.7
             benuPowerSupplyTable 1.3.6.1.4.1.39406.1.1.1.7.1 no-access
Benu power supply state information.
                 benuPowerSupplyEntry 1.3.6.1.4.1.39406.1.1.1.7.1.1 no-access
Power supply table.
                     benuPowerSupplyIndex 1.3.6.1.4.1.39406.1.1.1.7.1.1.1 integer no-access
This object is used to identify the power supply. Enumeration: 'powerB': 2, 'powerA': 1.
                     benuPowerSupplyName 1.3.6.1.4.1.39406.1.1.1.7.1.1.2 displaystring read-only
The name of the power supply.
                     benuPowerSupplyPresent 1.3.6.1.4.1.39406.1.1.1.7.1.1.3 integer read-only
Indicates whether or not the power supply is installed in the chassis. Enumeration: 'yes': 1, 'no': 2.
                     benuPowerSupplyType 1.3.6.1.4.1.39406.1.1.1.7.1.1.4 integer read-only
Indicates the type of the power supply. Enumeration: 'notApplicable': 3, 'ac': 1, 'dc': 2.
                     benuPowerSupplyPowered 1.3.6.1.4.1.39406.1.1.1.7.1.1.5 integer read-only
Indicates whether or not the power supply is actively supplying power. The value of notApplicable(3) will show if the entry for benuPowerSupplyPresent is no(2). Enumeration: 'notApplicable': 3, 'notPowered': 2, 'powered': 1.
     benuChassisNotifVariables 1.3.6.1.4.1.39406.1.1.2
         benuChassisPowerFailureInfo 1.3.6.1.4.1.39406.1.1.2.1 integer no-access
Indicates the location of the Power Failure. Enumeration: 'powerFailureA': 1, 'powerFailureB': 2, 'powerRestoredA': 3, 'powerRestoredB': 4.
         benuChassisFanFailureInfo 1.3.6.1.4.1.39406.1.1.2.2 displaystring no-access
Indicates the location of the Fan Failure.
         benuChassisPowerFailureCardInfo 1.3.6.1.4.1.39406.1.1.2.3 unsigned32 no-access
Indicates the Card Index Card Index starts from #1.
         benuChassisPowerInfo 1.3.6.1.4.1.39406.1.1.2.4 integer no-access
Indicates the location of the Power Failure or recovery. Enumeration: 'powerSupplyB': 2, 'powerSupplyA': 1.