Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
|
|||
Object Name | OID | Type | Access | Info |
emersonESNA | 1.3.6.1.4.1.885 | |||
bdfbMIB | 1.3.6.1.4.1.885.5 |
Emerson Energy Systems North America(ESNA) mini-BDFB MIB. revision 1.0.0.0 |
||
bdfbInformation | 1.3.6.1.4.1.885.5.1 | |||
bdfbMeterPanelVersionNumber | 1.3.6.1.4.1.885.5.1.1 | displaystring | read-only |
Meter Panel Firmware Version Number. |
bdfbEthernetCardVersionNumber | 1.3.6.1.4.1.885.5.1.2 | displaystring | read-only |
Ethernet Card Firmware Version Number. |
bdfbIdentifier | 1.3.6.1.4.1.885.5.1.3 | displaystring | read-only |
BDFB Identifier String. |
bdfbStatus | 1.3.6.1.4.1.885.5.2 | |||
bdfbMeasurement | 1.3.6.1.4.1.885.5.2.1 | |||
bdfbAverageBusVoltage | 1.3.6.1.4.1.885.5.2.1.1 | displaystring | read-only |
Average Bus Voltage. |
bdfbTotalBusCurrent | 1.3.6.1.4.1.885.5.2.1.2 | integer | read-only |
Ttotal Bus Current. |
bdfbAlarm | 1.3.6.1.4.1.885.5.2.1.3 | integer | read-only |
An Alarm Is Active. Enumeration: 'true': 1, 'false': 0. |
bdfbBusTable | 1.3.6.1.4.1.885.5.2.2 | no-access |
BDFB Bus Table. |
|
1.3.6.1.4.1.885.5.2.2.1 | no-access |
BDFB Bus Table Entry. |
||
bdfbBusIndex | 1.3.6.1.4.1.885.5.2.2.1.1 | integer | read-only |
BDFB Bus Number. |
bdfbBusIdentifier | 1.3.6.1.4.1.885.5.2.2.1.2 | displaystring | read-only |
BDFB Bus Identifier. |
bdfbBusVoltage | 1.3.6.1.4.1.885.5.2.2.1.3 | displaystring | read-only |
BDFB Bus Voltage. |
bdfbBusCurrent | 1.3.6.1.4.1.885.5.2.2.1.4 | integer | read-only |
BDFB Bus Current. |
bdfbRelayTable | 1.3.6.1.4.1.885.5.2.3 | no-access |
BDFB Relay Table. |
|
1.3.6.1.4.1.885.5.2.3.1 | no-access |
BDFB Relay Table Entry. |
||
bdfbRelayIndex | 1.3.6.1.4.1.885.5.2.3.1.1 | integer | read-only |
BDFB Relay Number. |
bdfbRelayIdentifier | 1.3.6.1.4.1.885.5.2.3.1.2 | displaystring | read-only |
BDFB Relay Identifier String. |
bdfbRelayStatus | 1.3.6.1.4.1.885.5.2.3.1.3 | integer | read-only |
BDFB Relay Status String. Enumeration: 'on': 1, 'off': 0. |
bdfbTraps | 1.3.6.1.4.1.885.5.3 | |||
bdfbSystemTraps | 1.3.6.1.4.1.885.5.3.0 | |||
alarmTrapBDFBRelay1 | 1.3.6.1.4.1.885.5.3.0.1 |
BDFB Relay 1 Typically Configured as Major Remote. |
||
alarmTrapBDFBRelay2 | 1.3.6.1.4.1.885.5.3.0.2 |
BDFB Relay 2 Typically Configured as Minor Remote. |
||
alarmTrapBDFBRelay3 | 1.3.6.1.4.1.885.5.3.0.3 |
BDFB Relay 3 Typically Configured as Custom Remote. |
||
alarmTrapBDFBRelay4 | 1.3.6.1.4.1.885.5.3.0.4 |
BDFB Relay 4 Typically Configured as Custom Remote. |
||
alarmTrapBDFBAuxABSFuse | 1.3.6.1.4.1.885.5.3.0.5 |
Auxillary ABS Fuse Trap. |
||
alarmTrapBDFBCommFail | 1.3.6.1.4.1.885.5.3.0.6 |
Communication failure between ethernet card and main board. |
||
bdfbBusTypeTraps | 1.3.6.1.4.1.885.5.3.1 | |||
bdfbBusTraps | 1.3.6.1.4.1.885.5.3.1.0 | |||
trapBusIdentifier | 1.3.6.1.4.1.885.5.3.1.0.2 | displaystring | no-access |
Bus Identifier. This object cannot be accessed. It is used to clarify the source of a Bus trap |
trapBDFBBusFuse | 1.3.6.1.4.1.885.5.3.1.0.3 |
BDFB Bus Fuse Alarm. |
||
trapBDFBBusLowVoltage | 1.3.6.1.4.1.885.5.3.1.0.4 |
BDFB Bus Low Voltage Alarm. |
||
trapBDFBBusPowerLost | 1.3.6.1.4.1.885.5.3.1.0.5 |
BDFB Bus Power Lost Alarm. |
||
trapBDFBBusHighCurrent1 | 1.3.6.1.4.1.885.5.3.1.0.6 |
BDFB Bus High Current 1 Alarm. |
||
trapBDFBBusHighCurrent2 | 1.3.6.1.4.1.885.5.3.1.0.7 |
BDFB Bus High Current 2 Alarm. |
||
bdfbGroups | 1.3.6.1.4.1.885.5.4 | |||
bdfbInformationGroup | 1.3.6.1.4.1.885.5.4.1 |
A collection of objects providing information to identify the BDFB plant and the version of monitoring software. |
||
bdfbMeasurementGroup | 1.3.6.1.4.1.885.5.4.2 |
A collection of objects providing BDFB Plant measurements and status. |
||
bdfbNotificationsGroup | 1.3.6.1.4.1.885.5.4.3 |
The notifications which indicate BDFB Plant alarms. |