BAY-STACK-SFF-MIB: View SNMP OID List / Download MIB

VENDOR: SYNOPTICS


 Home MIB: BAY-STACK-SFF-MIB
Download as:   

Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
 bayStackDdiSfpMib 1.3.6.1.4.1.45.5.29
Avaya SFF MIB Copyright 2012 Avaya, Inc. All rights reserved. This Avaya SNMP Management Information Base Specification embodies Avaya's confidential and proprietary intellectual property. Avaya retains all title and ownership in the Specification, including any revisions. This Specification is supplied 'AS IS,' and Avaya makes no warranty, either express or implied, as to the use, operation, condition, or performance of the Specification.
       bsDdiSfpNotifications 1.3.6.1.4.1.45.5.29.0
           bsDdiSfpTempAlarm 1.3.6.1.4.1.45.5.29.0.1
This notification is generated when a transceiver's temperature reaches an alarm level.
           bsDdiSfpTempWarn 1.3.6.1.4.1.45.5.29.0.2
This notification is generated when a transceiver's temperature reaches a warning level.
           bsDdiSfpTempNormal 1.3.6.1.4.1.45.5.29.0.3
This notification is generated when a transceiver's temperature reaches normal operating level. The notification is triggered after the transceiver's temperature has reached a warning or alarm level and then returns to normal level.
           bsDdiSfpVoltageAlarm 1.3.6.1.4.1.45.5.29.0.4
This notification is generated when a transceiver's voltage reaches an alarm level.
           bsDdiSfpVoltageWarn 1.3.6.1.4.1.45.5.29.0.5
This notification is generated when a transceiver's voltage reaches a warning level.
           bsDdiSfpVoltageNormal 1.3.6.1.4.1.45.5.29.0.6
This notification is generated when a transceiver's voltage reaches normal operating level. The notification is triggered after the transceiver's voltage has reached a warning or alarm level and then returns to normal level.
           bsDdiSfpBiasAlarm 1.3.6.1.4.1.45.5.29.0.7
This notification is generated when a transceiver's bias reaches an alarm level.
           bsDdiSfpBiasWarn 1.3.6.1.4.1.45.5.29.0.8
This notification is generated when a transceiver's bias reaches a warning level.
           bsDdiSfpBiasNormal 1.3.6.1.4.1.45.5.29.0.9
This notification is generated when a transceiver's bias reaches normal operating level. The notification is triggered after the transceiver's bias has reached a warning or alarm level and then returns to normal level.
           bsDdiSfpTxAlarm 1.3.6.1.4.1.45.5.29.0.10
This notification is generated when a transceiver's transmit power reaches an alarm level.
           bsDdiSfpTxWarn 1.3.6.1.4.1.45.5.29.0.11
This notification is generated when a transceiver's transmit power reaches a warning level.
           bsDdiSfpTxNormal 1.3.6.1.4.1.45.5.29.0.12
This notification is generated when a transceiver's transmit power reaches normal operating level. The notification is triggered after the transceiver's transmit power has reached a warning or alarm level and then returns to normal level.
           bsDdiSfpRxAlarm 1.3.6.1.4.1.45.5.29.0.13
This notification is generated when a transceiver's receive power reaches an alarm level.
           bsDdiSfpRxWarn 1.3.6.1.4.1.45.5.29.0.14
This notification is generated when a transceiver's receive power reaches a warning level.
           bsDdiSfpRxNormal 1.3.6.1.4.1.45.5.29.0.15
This notification is generated when a transceiver's receive power reaches normal operating level. The notification is triggered after the transceiver's receive power has reached a warning or alarm level and then returns to normal level.
       bsDdiSfpObjects 1.3.6.1.4.1.45.5.29.1
           bsDdiSfpTable 1.3.6.1.4.1.45.5.29.1.2 no-access
This table contains information about DDI SFPs. Entries will exist in this table only for DDI SFP ports.
               bsDdiSfpEntry 1.3.6.1.4.1.45.5.29.1.2.1 no-access
SFF interface settings.
                   bsDdiSfpIfIndex 1.3.6.1.4.1.45.5.29.1.2.1.1 interfaceindex no-access
Identifies the ifIndex of the SFF port.
                   bsDdiSfpCalibration 1.3.6.1.4.1.45.5.29.1.2.1.2 integer read-only
This object indicates whether the actual values read from EEPROM internally within an implementation are already calibrated to the appropriate units (Volts, mA, dB, etc), or whether these values are first converted to appropriate units. The value external(2) indicates that the values as read from EEPROM must be converted. Note that this is only an indication of what happens internally within an implementation, and does not have any effect on the values of other columns in this table. Enumeration: 'internal': 1, 'external': 2.
                   bsDdiSfpRxPowerMeasurement 1.3.6.1.4.1.45.5.29.1.2.1.3 integer read-only
This object indicates the measurement type used for the received power. A value of oma(1) indicates Optical Modulation Amplitude (OMA). Enumeration: 'oma': 1, 'averagePower': 2.
                   bsDdiSfpTempValue 1.3.6.1.4.1.45.5.29.1.2.1.4 integer32 read-only
The actual temperature value, measured in 1/10000 Celsius.
                   bsDdiSfpTempLowAlarmThreshold 1.3.6.1.4.1.45.5.29.1.2.1.5 integer32 read-only
The low alarm temperature threshold, measure in 1/10000 Celsius.
                   bsDdiSfpTempLowWarnThreshold 1.3.6.1.4.1.45.5.29.1.2.1.6 integer32 read-only
The low warn temperature threshold, measure in 1/10000 Celsius.
                   bsDdiSfpTempHighAlarmThreshold 1.3.6.1.4.1.45.5.29.1.2.1.7 integer32 read-only
The high alarm temperature threshold, measure in 1/10000 Celsius.
                   bsDdiSfpTempHighWarnThreshold 1.3.6.1.4.1.45.5.29.1.2.1.8 integer32 read-only
The high warn temperature threshold, measure in 1/10000 Celsius.
                   bsDdiSfpVoltageValue 1.3.6.1.4.1.45.5.29.1.2.1.9 integer32 read-only
The actual voltage value, measured in 1/10000 volts.
                   bsDdiSfpVoltageLowAlarmThreshold 1.3.6.1.4.1.45.5.29.1.2.1.10 integer32 read-only
The low alarm voltage threshold, measured in 1/10000 volts.
                   bsDdiSfpVoltageLowWarnThreshold 1.3.6.1.4.1.45.5.29.1.2.1.11 integer32 read-only
The low warn voltage threshold, measured in 1/10000 volts.
                   bsDdiSfpVoltageHighAlarmThreshold 1.3.6.1.4.1.45.5.29.1.2.1.12 integer32 read-only
The high alarm voltage threshold, measured in 1/10000 volts.
                   bsDdiSfpVoltageHighWarnThreshold 1.3.6.1.4.1.45.5.29.1.2.1.13 integer32 read-only
The high warn voltage threshold, measured in 1/10000 volts.
                   bsDdiSfpBiasValue 1.3.6.1.4.1.45.5.29.1.2.1.14 integer32 read-only
The actual bias value, measured in 1/10000 mA.
                   bsDdiSfpBiasLowAlarmThreshold 1.3.6.1.4.1.45.5.29.1.2.1.15 integer32 read-only
The low alarm bias threshold, measured in 1/10000 mA.
                   bsDdiSfpBiasLowWarnThreshold 1.3.6.1.4.1.45.5.29.1.2.1.16 integer32 read-only
The low warn bias threshold, measured in 1/10000 mA.
                   bsDdiSfpBiasHighAlarmThreshold 1.3.6.1.4.1.45.5.29.1.2.1.17 integer32 read-only
The high alarm bias threshold, measured in 1/10000 mA.
                   bsDdiSfpBiasHighWarnThreshold 1.3.6.1.4.1.45.5.29.1.2.1.18 integer32 read-only
The high warn bias threshold, measured in 1/10000 mA.
                   bsDdiSfpTxPowerValue 1.3.6.1.4.1.45.5.29.1.2.1.19 integer32 read-only
The actual transmit power value, measured in 1/10000 dBm.
                   bsDdiSfpTxPowerLowAlarmThreshold 1.3.6.1.4.1.45.5.29.1.2.1.20 integer32 read-only
The low alarm transmit power threshold, measured in 1/10000 dBm.
                   bsDdiSfpTxPowerLowWarnThreshold 1.3.6.1.4.1.45.5.29.1.2.1.21 integer32 read-only
The low warn transmit power threshold, measured in 1/10000 dBm.
                   bsDdiSfpTxPowerHighAlarmThreshold 1.3.6.1.4.1.45.5.29.1.2.1.22 integer32 read-only
The high alarm transmit power threshold, measured in 1/10000 dBm.
                   bsDdiSfpTxPowerHighWarnThreshold 1.3.6.1.4.1.45.5.29.1.2.1.23 integer32 read-only
The high warn transmit power threshold, measured in 1/10000 dBm.
                   bsDdiSfpRxPowerValue 1.3.6.1.4.1.45.5.29.1.2.1.24 integer32 read-only
The actual receive power value, measured in 1/10000 dBm.
                   bsDdiSfpRxPowerLowAlarmThreshold 1.3.6.1.4.1.45.5.29.1.2.1.25 integer32 read-only
The low alarm receive power threshold, measured in 1/10000 dBm.
                   bsDdiSfpRxPowerLowWarnThreshold 1.3.6.1.4.1.45.5.29.1.2.1.26 integer32 read-only
The low warn receive power threshold, measured in 1/10000 dBm.
                   bsDdiSfpRxPowerHighAlarmThreshold 1.3.6.1.4.1.45.5.29.1.2.1.27 integer32 read-only
The high alarm receive power threshold, measured in 1/10000 dBm.
                   bsDdiSfpRxPowerHighWarnThreshold 1.3.6.1.4.1.45.5.29.1.2.1.28 integer32 read-only
The high warn receive power threshold, measured in 1/10000 dBm.