BAS-SONET-MIB: View SNMP OID List / Download MIB

VENDOR: BROADBAND ACCESS SYSTEMS


 Home MIB: BAS-SONET-MIB
Download as:   

Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
 basSonetMib 1.3.6.1.4.1.3493.2.20.1
This MIB module defines the configuration and status MIB objects for a Broadband Access System SONET interface.
     basSonetObjects 1.3.6.1.4.1.3493.2.20.1.1
         basSonetPathTable 1.3.6.1.4.1.3493.2.20.1.1.1 no-access
A table containing SONET Path specific variables for this POS implementation.
             basSonetPathEntry 1.3.6.1.4.1.3493.2.20.1.1.1.1 no-access
Management information about a particular POS Link.
                 basSonetPathB3Err 1.3.6.1.4.1.3493.2.20.1.1.1.1.1 counter32 read-only
The number of packets received on this link with B3 bit errors. Bit Interleaved Parity 8 is calculated over all bits in the SPE of each frame.
                 basSonetPathG1Err 1.3.6.1.4.1.3493.2.20.1.1.1.1.2 counter32 read-only
The number of B3 errors that were detected by the remote terminal in its received signal.
                 basSonetPathPais 1.3.6.1.4.1.3493.2.20.1.1.1.1.3 counter32 read-only
The number of times a Path Alarm Indication Signal has been detected. A PAIS occurs if all the H1/H2 pointer bytes in the received SONET frame are 01.
                 basSonetPathPrdi 1.3.6.1.4.1.3493.2.20.1.1.1.1.4 counter32 read-only
The number of times a Path Remote Defect Indication has been detected. A PRDI occurs if bits 5,6 and 7 of the G1 byte received with the same value for 5 onsecutive frames.
                 basSonetPathPlop 1.3.6.1.4.1.3493.2.20.1.1.1.1.5 counter32 read-only
The number of times a Path Loss of Pointer has been detected. A PLOP occurs if all the H1/H2 pointer bytes in the received SONET frame are not all 01 indicating PRDI or the first pair equals 00 and all other pairs equaling 11 indicating normal operation.
                 basSonetPathB3Threshold 1.3.6.1.4.1.3493.2.20.1.1.1.1.6 integer32 read-write
The number of packets received with B3 errors hits this threshold issue an alarm.
                 basSonetPathRxJ1 1.3.6.1.4.1.3493.2.20.1.1.1.1.7 integer32 read-only
The first J1 byte received in last packet.
                 basSonetPathRxC2 1.3.6.1.4.1.3493.2.20.1.1.1.1.8 integer32 read-only
C2 byte received in last packet.
                 basSonetPathRxG1 1.3.6.1.4.1.3493.2.20.1.1.1.1.9 integer32 read-only
G1 byte received in last packet.
         basSonetLineTable 1.3.6.1.4.1.3493.2.20.1.1.2 no-access
A table containing SONET Line specific variables for this POS implementation.
             basSonetLineEntry 1.3.6.1.4.1.3493.2.20.1.1.2.1 no-access
Management information about a particular POS Link.
                 basSonetLineTxErr 1.3.6.1.4.1.3493.2.20.1.1.2.1.1 counter32 read-only
The sum of all transmit errors that caused the packet to not be transmitted. These errors consist of tx fifo error, link layer errors, minimum packet size violations, maximum packet size violations and tx parity errors.
                 basSonetLineB1Err 1.3.6.1.4.1.3493.2.20.1.1.2.1.2 counter32 read-only
The number of packets received on this link with B1 bit errors. Bit Interleaved Parity 8 is calculated over all bytes of each frame.
                 basSonetLineB2Err 1.3.6.1.4.1.3493.2.20.1.1.2.1.3 counter32 read-only
The number of packets received on this link with B2 bit errors. Bit Interleaved Parity 8 is calculated over all bytes of each frame except for the first three rows of the TOH
                 basSonetLineM1Err 1.3.6.1.4.1.3493.2.20.1.1.2.1.4 counter32 read-only
The number of B2 errors that were detected by the remote terminal in its received signal.
                 basSonetLineRxFifoOverflow 1.3.6.1.4.1.3493.2.20.1.1.2.1.5 counter32 read-only
The number of packets received on this link with an error detected in the receive fifo.
                 basSonetLineRxAbort 1.3.6.1.4.1.3493.2.20.1.1.2.1.6 counter32 read-only
The number of packets received on this link in which the abort sequence is detected.
                 basSonetLineRxRunts 1.3.6.1.4.1.3493.2.20.1.1.2.1.7 counter32 read-only
The number of packets received on this link which are smaller than the minimum packet size.
                 basSonetLineLoc 1.3.6.1.4.1.3493.2.20.1.1.2.1.8 counter32 read-only
The number of times a loss of clock has been detected. LOC occurs if no transitions are detected on the receive SONET clock for 16 periods of the transmit clock..
                 basSonetLineLof 1.3.6.1.4.1.3493.2.20.1.1.2.1.9 counter32 read-only
The number of times a loss of frame has been detected. LOF occurs if RX_OOF (out-of-frame) is active continuously for 24 consecutive frames (3 ms).
                 basSonetLineLos 1.3.6.1.4.1.3493.2.20.1.1.2.1.10 counter32 read-only
The number of times a loss of signal has been detected. A LOS indicates to the framer that there is no signal present from the optical receiver.
                 basSonetLineLais 1.3.6.1.4.1.3493.2.20.1.1.2.1.11 counter32 read-only
The number of times a Line Alarm Indication Signal has been detected. A LAIS occurs if the 3 LSBs of K2 are received as '111' for 5 consecutive frames
                 basSonetLineLrdi 1.3.6.1.4.1.3493.2.20.1.1.2.1.12 counter32 read-only
The number of times a Line Remote Defect Indication has been detected. A LRDI occurs if the 3 LSBs of K2 are not received as '110' for 5 consecutive frames.
                 basSonetLineB1Threshold 1.3.6.1.4.1.3493.2.20.1.1.2.1.13 integer32 read-write
The number of packets received with B1 errors hits this threshold issue an alarm.
                 basSonetLineB2Threshold 1.3.6.1.4.1.3493.2.20.1.1.2.1.14 integer32 read-write
The number of packets received with B2 errors hits this threshold issue an alarm.
                 basSonetLineSFThreshold 1.3.6.1.4.1.3493.2.20.1.1.2.1.15 integer32 read-write
The number of packets received with B2 errors hits this threshold issue a signal fail alarm.
                 basSonetLineSDThreshold 1.3.6.1.4.1.3493.2.20.1.1.2.1.16 integer32 read-write
The number of packets received with B2 errors hits this threshold issue a signal degrade alarm.
                 basSonetLineLastCleared 1.3.6.1.4.1.3493.2.20.1.1.2.1.17 timestamp read-only
The value of sysUpTime when these Counter32s were last cleared.
                 basSonetLineRxK1 1.3.6.1.4.1.3493.2.20.1.1.2.1.18 integer32 read-only
K1 byte received in last packet.
                 basSonetLineRxK2 1.3.6.1.4.1.3493.2.20.1.1.2.1.19 integer32 read-only
K2 byte received in last packet.
                 basSonetLineRxGiants 1.3.6.1.4.1.3493.2.20.1.1.2.1.20 counter32 read-only
The number of packets received on this link which are larger than the maximum packet size.