BARCO-CLICKSHARE-MIB: View SNMP OID List / Download MIB

VENDOR: BARCO CONTROL ROOMS


 Home MIB: BARCO-CLICKSHARE-MIB
Download as:   

Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
 barco 1.3.6.1.4.1.7312
           clickShare 1.3.6.1.4.1.7312.2468
This MIB module defines a set of event triggers and actions for network management of ClickShare devices
                     events 1.3.6.1.4.1.7312.2468.0
                         alarmCpuTemperature 1.3.6.1.4.1.7312.2468.0.1
An alarmCpuTemperature trap idicates that the CPU temperature exceeded the threshold.
                         alarmCaseFanSpeed 1.3.6.1.4.1.7312.2468.0.2
An alarmCaseFanSpeed trap idicates that the case fan is spinning too slow.
                         alarmProcessNotRunning 1.3.6.1.4.1.7312.2468.0.3
An alarmProcessNotRunning trap idicates that one of the monitored processes is not running.
                     baseUnit 1.3.6.1.4.1.7312.2468.1
                         deviceInfo 1.3.6.1.4.1.7312.2468.1.1
                             diRoomName 1.3.6.1.4.1.7312.2468.1.1.1 displaystring read-only
Name of the meeting room where the Base Unit is located. This string will be visible on the Base Unit's screen.
                             diWelcomeMessage 1.3.6.1.4.1.7312.2468.1.1.2 displaystring read-only
A welcome message visible on the Base Unit's screen.
                             diLocation 1.3.6.1.4.1.7312.2468.1.1.3 displaystring read-only
Name of the location where the Base Unit is located.
                             diArticleCode 1.3.6.1.4.1.7312.2468.1.1.4 displaystring read-only
The Base Unit article code.
                             diSerialNumber 1.3.6.1.4.1.7312.2468.1.1.5 displaystring read-only
The Base Unit serial number.
                             diUptime 1.3.6.1.4.1.7312.2468.1.1.6 unsigned32 read-only
The Base Unit current uptime.
                             diTotalUptime 1.3.6.1.4.1.7312.2468.1.1.7 unsigned32 read-only
The Base Unit total uptime.
                         sensors 1.3.6.1.4.1.7312.2468.1.2
                             sensorCaseFanSpeed 1.3.6.1.4.1.7312.2468.1.2.1 displaystring read-only
Indicates the current speed of the case fan.
                             sensorCpuFanSpeed 1.3.6.1.4.1.7312.2468.1.2.2 displaystring read-only
Indicates the current speed of the CPU fan.
                             sensorCpuTemperature 1.3.6.1.4.1.7312.2468.1.2.3 displaystring read-only
Indicates the current CPU temperature.
                             sensorCpuTemperatureThreshold 1.3.6.1.4.1.7312.2468.1.2.4 displaystring read-only
The CPU temperature limit. If the current temperature exceeds this setting, the Base Unit will shut down itself
           clickShareMIB 1.3.6.1.4.1.7312.2469
                     clickShareMIBCompliances 1.3.6.1.4.1.7312.2469.1
                         clickShareMIBCompliance 1.3.6.1.4.1.7312.2469.1.1
The compliance statement for ClickShare Base Unit devices.
                     clickShareMIBGroups 1.3.6.1.4.1.7312.2469.2
                         deviceInfoGroup 1.3.6.1.4.1.7312.2469.2.1
The group of Device Info objects.
                         sensorsGroup 1.3.6.1.4.1.7312.2469.2.2
The group of sensor objects.
                         eventsGroup 1.3.6.1.4.1.7312.2469.2.99
The group of SNMP trap objects.