Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
 argus 1.3.6.1.4.1.7309
This MIB defines the information block(s) available in system controllers as defined by the following list: - dcPwrSysDevice: the SM-series of controllers
           dcpower 1.3.6.1.4.1.7309.4
               dcPwrSysDevice 1.3.6.1.4.1.7309.4.1
                   dcPwrSysVariable 1.3.6.1.4.1.7309.4.1.1
                       dcPwrSysChargeVolts 1.3.6.1.4.1.7309.4.1.1.1 integer read-only
Battery Charge Voltage. The integer value represent a two digit fix decimal (Value = real voltage * 100) in Volt
                       dcPwrSysDischargeVolts 1.3.6.1.4.1.7309.4.1.1.2 integer read-only
Battery Discharge Voltage. The integer value represent a two digit fix decimal (Value = real voltage * 100) in Volt
                       dcPwrSysChargeAmps 1.3.6.1.4.1.7309.4.1.1.3 integer read-only
Battery Charge Current. The integer value represent a two digit fix decimal (Value = real current * 100) in Amp
                       dcPwrSysDischargeAmps 1.3.6.1.4.1.7309.4.1.1.4 integer read-only
Battery Discharge Current. The integer value represent a two digit fix decimal (Value = real current * 100) in Amp
                       dcPwrSysMajorAlarm 1.3.6.1.4.1.7309.4.1.1.5 integer read-only
Major Alarm
                       dcPwrSysMinorAlarm 1.3.6.1.4.1.7309.4.1.1.6 integer read-only
Minor Alarm
                   dcPwrSysString 1.3.6.1.4.1.7309.4.1.2
                       dcPwrSysSiteName 1.3.6.1.4.1.7309.4.1.2.1 displaystring read-only
Site Name
                       dcPwrSysSiteCity 1.3.6.1.4.1.7309.4.1.2.2 displaystring read-only
Site City
                       dcPwrSysSiteRegion 1.3.6.1.4.1.7309.4.1.2.3 displaystring read-only
Site Region
                       dcPwrSysSiteCountry 1.3.6.1.4.1.7309.4.1.2.4 displaystring read-only
Site Country
                       dcPwrSysContactName 1.3.6.1.4.1.7309.4.1.2.5 displaystring read-only
Contact Name
                       dcPwrSysPhoneNumber 1.3.6.1.4.1.7309.4.1.2.6 displaystring read-only
Phone Number
                       dcPwrSysSiteNumber 1.3.6.1.4.1.7309.4.1.2.7 displaystring read-only
Site Number
                       dcPwrSysSystemType 1.3.6.1.4.1.7309.4.1.2.8 displaystring read-only
The type of system being monitored by the agent
                       dcPwrSysSystemSerial 1.3.6.1.4.1.7309.4.1.2.9 displaystring read-only
The serial number of the monitored system
                       dcPwrSysSystemNumber 1.3.6.1.4.1.7309.4.1.2.10 displaystring read-only
The number of the monitored system
                       dcPwrSysSoftwareVersion 1.3.6.1.4.1.7309.4.1.2.11 displaystring read-only
The version of software running on the monitored system
                       dcPwrSysSoftwareTimestamp 1.3.6.1.4.1.7309.4.1.2.12 displaystring read-only
The time stamp of the software running on the monitored system
                   dcPwrSysTraps 1.3.6.1.4.1.7309.4.1.3
                       dcPwrSysTrap 1.3.6.1.4.1.7309.4.1.3.0
                           dcPwrSysAlarmActiveTrap 1.3.6.1.4.1.7309.4.1.3.0.1
A trap issued when one of the alarms on the DC power system controller became active
                           dcPwrSysAlarmClearedTrap 1.3.6.1.4.1.7309.4.1.3.0.2
A trap issued when one of the active alarms on the DC power system controller is cleared
                           dcPwrSysRelayTrap 1.3.6.1.4.1.7309.4.1.3.0.3
A trap issued from a change in state in one of the relays on the DC power system controller
                           dcPwrSysComOKTrap 1.3.6.1.4.1.7309.4.1.3.0.4
A trap to indicate that communications with a DC power system controller has been established.
                           dcPwrSysComErrTrap 1.3.6.1.4.1.7309.4.1.3.0.5
A trap to indicate that communications with a DC power system controller has been lost.
                           dcPwrSysAgentStartupTrap 1.3.6.1.4.1.7309.4.1.3.0.6
A trap to indicate that the agent software has started up.
                           dcPwrSysAgentShutdownTrap 1.3.6.1.4.1.7309.4.1.3.0.7
A trap to indicate that the agent software has shutdown.
                           dcPwrSysMajorAlarmActiveTrap 1.3.6.1.4.1.7309.4.1.3.0.8
A trap issued as a summary of DC power system status. It is sent when the system goes into in Major Alarm
                           dcPwrSysMajorAlarmClearedTrap 1.3.6.1.4.1.7309.4.1.3.0.9
A trap issued as a summary of DC power system status. It is sent when the system comes out of Major Alarm
                           dcPwrSysMinorAlarmActiveTrap 1.3.6.1.4.1.7309.4.1.3.0.10
A trap issued as a summary of DC power system status. It is sent when the system goes into in Minor Alarm
                           dcPwrSysMinorAlarmClearedTrap 1.3.6.1.4.1.7309.4.1.3.0.11
A trap issued as a summary of DC power system status. It is sent when the system comes out of Minor Alarm
                   dcPwrSysOutputsTbl 1.3.6.1.4.1.7309.4.1.4
                       dcPwrSysRelayTbl 1.3.6.1.4.1.7309.4.1.4.1
                           dcPwrSysRelayCount 1.3.6.1.4.1.7309.4.1.4.1.1 integer read-only
Number of relay variables in system controller relay table
                           dcPwrSysRelayTable 1.3.6.1.4.1.7309.4.1.4.1.2 no-access
A table of DC power system controller rectifier relay output variables
                               dcPwrSysRelayEntry 1.3.6.1.4.1.7309.4.1.4.1.2.1 no-access
An entry into the DC power system controller relay output group
                                   dcPwrSysRelayIndex 1.3.6.1.4.1.7309.4.1.4.1.2.1.1 integer read-only
The index of the relay variable in the power system controller relay output group
                                   dcPwrSysRelayName 1.3.6.1.4.1.7309.4.1.4.1.2.1.2 displaystring read-only
The description of the relay variable as reported by the DC power system controller relay output group
                                   dcPwrSysRelayIntegerValue 1.3.6.1.4.1.7309.4.1.4.1.2.1.3 integer read-only
The integer value of the relay variable as reported by the DC power system controller relay output group
                                   dcPwrSysRelayStringValue 1.3.6.1.4.1.7309.4.1.4.1.2.1.4 displaystring read-only
The string value of the relay variable as reported by the DC power system controller relay output group
                                   dcPwrSysRelaySeverity 1.3.6.1.4.1.7309.4.1.4.1.2.1.5 integer read-only
The integer value of relay severity level of the extra variable as reported by the DC power system controller relay output group
                       dcPwrSysAnalogOpTbl 1.3.6.1.4.1.7309.4.1.4.2
                           dcPwrSysAnalogOpCount 1.3.6.1.4.1.7309.4.1.4.2.1 integer read-only
Number of analog output variables in system controller analog output table
                           dcPwrSysAnalogOpTable 1.3.6.1.4.1.7309.4.1.4.2.2 no-access
A table of DC power system controller analog output variables
                               dcPwrSysAnalogOpEntry 1.3.6.1.4.1.7309.4.1.4.2.2.1 no-access
An entry into the DC power system controller analog output group
                                   dcPwrSysAnalogOpIndex 1.3.6.1.4.1.7309.4.1.4.2.2.1.1 integer read-only
The index of the analog variable in the power system controller analog output group
                                   dcPwrSysAnalogOpName 1.3.6.1.4.1.7309.4.1.4.2.2.1.2 displaystring read-only
The description of the analog variable as reported by the DC power system controller analog output group
                                   dcPwrSysAnalogOpIntegerValue 1.3.6.1.4.1.7309.4.1.4.2.2.1.3 integer read-only
The integer value of the analog variable as reported by the DC power system controller analog output group
                                   dcPwrSysAnalogOpStringValue 1.3.6.1.4.1.7309.4.1.4.2.2.1.4 displaystring read-only
The string value of the analog variable as reported by the DC power system controller analog output group
                                   dcPwrSysAnalogOpSeverity 1.3.6.1.4.1.7309.4.1.4.2.2.1.5 integer read-only
The integer value of analog severity level of the extra variable as reported by the DC power system controller analog output group
                   dcPwrSysAlrmsTbl 1.3.6.1.4.1.7309.4.1.5
                       dcPwrSysRectAlrmTbl 1.3.6.1.4.1.7309.4.1.5.1
                           dcPwrSysRectAlrmCount 1.3.6.1.4.1.7309.4.1.5.1.1 integer read-only
Number of rectifier alarm variables in system controller alarm table
                           dcPwrSysRectAlrmTable 1.3.6.1.4.1.7309.4.1.5.1.2 no-access
A table of DC power system controller rectifier alarm variables
                               dcPwrSysRectAlrmEntry 1.3.6.1.4.1.7309.4.1.5.1.2.1 no-access
An entry into the DC power system controller rectifier alarm group
                                   dcPwrSysRectAlrmIndex 1.3.6.1.4.1.7309.4.1.5.1.2.1.1 integer read-only
The index of the alarm variable in the DC power system controller table rectifier alarm group
                                   dcPwrSysRectAlrmName 1.3.6.1.4.1.7309.4.1.5.1.2.1.2 displaystring read-only
The description of the alarm variable as reported by the DC power system controller rectifier alarm group
                                   dcPwrSysRectAlrmIntegerValue 1.3.6.1.4.1.7309.4.1.5.1.2.1.3 integer read-only
The integer value of the alarm variable as reported by the DC power system controller rectifier alarm group
                                   dcPwrSysRectAlrmStringValue 1.3.6.1.4.1.7309.4.1.5.1.2.1.4 displaystring read-only
The string value of the alarm variable as reported by the DC power system controller rectifier alarm group
                                   dcPwrSysRectAlrmSeverity 1.3.6.1.4.1.7309.4.1.5.1.2.1.5 integer read-only
The integer value of alarm severity level of the extra variable as reported by the DC power system controller rectifier alarm group
                       dcPwrSysDigAlrmTbl 1.3.6.1.4.1.7309.4.1.5.2
                           dcPwrSysDigAlrmCount 1.3.6.1.4.1.7309.4.1.5.2.1 integer read-only
Number of digital alarm variables in system controller alarm table
                           dcPwrSysDigAlrmTable 1.3.6.1.4.1.7309.4.1.5.2.2 no-access
A table of DC power system controller digital alarm variables
                               dcPwrSysDigAlrmEntry 1.3.6.1.4.1.7309.4.1.5.2.2.1 no-access
An entry into the DC power system controller digital alarm group
                                   dcPwrSysDigAlrmIndex 1.3.6.1.4.1.7309.4.1.5.2.2.1.1 integer read-only
The index of the alarm variable in the DC power system controller table digital alarm group
                                   dcPwrSysDigAlrmName 1.3.6.1.4.1.7309.4.1.5.2.2.1.2 displaystring read-only
The description of the alarm variable as reported by the DC power system controller digital alarm group
                                   dcPwrSysDigAlrmIntegerValue 1.3.6.1.4.1.7309.4.1.5.2.2.1.3 integer read-only
The integer value of the alarm variable as reported by the DC power system controller digital alarm group
                                   dcPwrSysDigAlrmStringValue 1.3.6.1.4.1.7309.4.1.5.2.2.1.4 displaystring read-only
The string value of the alarm variable as reported by the DC power system controller digital alarm group
                                   dcPwrSysDigAlrmSeverity 1.3.6.1.4.1.7309.4.1.5.2.2.1.5 integer read-only
The integer value of alarm severity level of the extra variable as reported by the DC power system controller digital alarm group
                       dcPwrSysCurrAlrmTbl 1.3.6.1.4.1.7309.4.1.5.3
                           dcPwrSysCurrAlrmCount 1.3.6.1.4.1.7309.4.1.5.3.1 integer read-only
Number of current alarm variables in system controller alarm table
                           dcPwrSysCurrAlrmTable 1.3.6.1.4.1.7309.4.1.5.3.2 no-access
A table of DC power system controller current alarm variables
                               dcPwrSysCurrAlrmEntry 1.3.6.1.4.1.7309.4.1.5.3.2.1 no-access
An entry into the DC power system controller current alarm group
                                   dcPwrSysCurrAlrmIndex 1.3.6.1.4.1.7309.4.1.5.3.2.1.1 integer read-only
The index of the alarm variable in the DC power system controller table current alarm group
                                   dcPwrSysCurrAlrmName 1.3.6.1.4.1.7309.4.1.5.3.2.1.2 displaystring read-only
The description of the alarm variable as reported by the DC power system controller current alarm group
                                   dcPwrSysCurrAlrmIntegerValue 1.3.6.1.4.1.7309.4.1.5.3.2.1.3 integer read-only
The integer value of the alarm variable as reported by the DC power system controller current alarm group
                                   dcPwrSysCurrAlrmStringValue 1.3.6.1.4.1.7309.4.1.5.3.2.1.4 displaystring read-only
The string value of the alarm variable as reported by the DC power system controller current alarm group
                                   dcPwrSysCurrAlrmSeverity 1.3.6.1.4.1.7309.4.1.5.3.2.1.5 integer read-only
The integer value of alarm severity level of the extra variable as reported by the DC power system controller current alarm group
                       dcPwrSysVoltAlrmTbl 1.3.6.1.4.1.7309.4.1.5.4
                           dcPwrSysVoltAlrmCount 1.3.6.1.4.1.7309.4.1.5.4.1 integer read-only
Number of voltage alarm variables in system controller alarm table
                           dcPwrSysVoltAlrmTable 1.3.6.1.4.1.7309.4.1.5.4.2 no-access
A table of DC power system controller voltage alarm variables
                               dcPwrSysVoltAlrmEntry 1.3.6.1.4.1.7309.4.1.5.4.2.1 no-access
An entry into the DC power system controller voltage alarm group
                                   dcPwrSysVoltAlrmIndex 1.3.6.1.4.1.7309.4.1.5.4.2.1.1 integer read-only
The index of the alarm variable in the DC power system controller table voltage alarm group
                                   dcPwrSysVoltAlrmName 1.3.6.1.4.1.7309.4.1.5.4.2.1.2 displaystring read-only
The description of the alarm variable as reported by the DC power system controller voltage alarm group
                                   dcPwrSysVoltAlrmIntegerValue 1.3.6.1.4.1.7309.4.1.5.4.2.1.3 integer read-only
The integer value of the alarm variable as reported by the DC power system controller voltage alarm group
                                   dcPwrSysVoltAlrmStringValue 1.3.6.1.4.1.7309.4.1.5.4.2.1.4 displaystring read-only
The string value of the alarm variable as reported by the DC power system controller voltage alarm group
                                   dcPwrSysVoltAlrmSeverity 1.3.6.1.4.1.7309.4.1.5.4.2.1.5 integer read-only
The integer value of alarm severity level of the extra variable as reported by the DC power system controller voltage alarm group
                       dcPwrSysBattAlrmTbl 1.3.6.1.4.1.7309.4.1.5.5
                           dcPwrSysBattAlrmCount 1.3.6.1.4.1.7309.4.1.5.5.1 integer read-only
Number of battery alarm variables in system controller alarm table
                           dcPwrSysBattAlrmTable 1.3.6.1.4.1.7309.4.1.5.5.2 no-access
A table of DC power system controller battery alarm variables
                               dcPwrSysBattAlrmEntry 1.3.6.1.4.1.7309.4.1.5.5.2.1 no-access
An entry into the DC power system controller battery alarm group
                                   dcPwrSysBattAlrmIndex 1.3.6.1.4.1.7309.4.1.5.5.2.1.1 integer read-only
The index of the alarm variable in the DC power system controller table battery alarm group
                                   dcPwrSysBattAlrmName 1.3.6.1.4.1.7309.4.1.5.5.2.1.2 displaystring read-only
The description of the alarm variable as reported by the DC power system controller battery alarm group
                                   dcPwrSysBattAlrmIntegerValue 1.3.6.1.4.1.7309.4.1.5.5.2.1.3 integer read-only
The integer value of the alarm variable as reported by the DC power system controller battery alarm group
                                   dcPwrSysBattAlrmStringValue 1.3.6.1.4.1.7309.4.1.5.5.2.1.4 displaystring read-only
The string value of the alarm variable as reported by the DC power system controller battery alarm group
                                   dcPwrSysBattAlrmSeverity 1.3.6.1.4.1.7309.4.1.5.5.2.1.5 integer read-only
The integer value of alarm severity level of the extra variable as reported by the DC power system controller battery alarm group
                       dcPwrSysTempAlrmTbl 1.3.6.1.4.1.7309.4.1.5.6
                           dcPwrSysTempAlrmCount 1.3.6.1.4.1.7309.4.1.5.6.1 integer read-only
Number of temperature alarm variables in system controller alarm table
                           dcPwrSysTempAlrmTable 1.3.6.1.4.1.7309.4.1.5.6.2 no-access
A table of DC power system controller temperature alarm variables
                               dcPwrSysTempAlrmEntry 1.3.6.1.4.1.7309.4.1.5.6.2.1 no-access
An entry into the DC power system controller temperature alarm group
                                   dcPwrSysTempAlrmIndex 1.3.6.1.4.1.7309.4.1.5.6.2.1.1 integer read-only
The index of the alarm variable in the DC power system controller table temperature alarm group
                                   dcPwrSysTempAlrmName 1.3.6.1.4.1.7309.4.1.5.6.2.1.2 displaystring read-only
The description of the alarm variable as reported by the DC power system controller temperature alarm group
                                   dcPwrSysTempAlrmIntegerValue 1.3.6.1.4.1.7309.4.1.5.6.2.1.3 integer read-only
The integer value of the alarm variable as reported by the DC power system controller temperature alarm group
                                   dcPwrSysTempAlrmStringValue 1.3.6.1.4.1.7309.4.1.5.6.2.1.4 displaystring read-only
The string value of the alarm variable as reported by the DC power system controller temperature alarm group
                                   dcPwrSysTempAlrmSeverity 1.3.6.1.4.1.7309.4.1.5.6.2.1.5 integer read-only
The integer value of alarm severity level of the extra variable as reported by the DC power system controller temperature alarm group
                       dcPwrSysCustomAlrmTbl 1.3.6.1.4.1.7309.4.1.5.7
                           dcPwrSysCustomAlrmCount 1.3.6.1.4.1.7309.4.1.5.7.1 integer read-only
Number of custom alarm variables in system controller alarm table
                           dcPwrSysCustomAlrmTable 1.3.6.1.4.1.7309.4.1.5.7.2 no-access
A table of DC power system controller custom alarm variables
                               dcPwrSysCustomAlrmEntry 1.3.6.1.4.1.7309.4.1.5.7.2.1 no-access
An entry into the DC power system controller custom alarm group
                                   dcPwrSysCustomAlrmIndex 1.3.6.1.4.1.7309.4.1.5.7.2.1.1 integer read-only
The index of the alarm variable in the DC power system controller table custom alarm group
                                   dcPwrSysCustomAlrmName 1.3.6.1.4.1.7309.4.1.5.7.2.1.2 displaystring read-only
The description of the alarm variable as reported by the DC power system controller custom alarm group
                                   dcPwrSysCustomAlrmIntegerValue 1.3.6.1.4.1.7309.4.1.5.7.2.1.3 integer read-only
The integer value of the alarm variable as reported by the DC power system controller custom alarm group
                                   dcPwrSysCustomAlrmStringValue 1.3.6.1.4.1.7309.4.1.5.7.2.1.4 displaystring read-only
The string value of the alarm variable as reported by the DC power system controller custom alarm group
                                   dcPwrSysCustomAlrmSeverity 1.3.6.1.4.1.7309.4.1.5.7.2.1.5 integer read-only
The integer value of alarm severity level of the extra variable as reported by the DC power system controller custom alarm group
                       dcPwrSysMiscAlrmTbl 1.3.6.1.4.1.7309.4.1.5.8
                           dcPwrSysMiscAlrmCount 1.3.6.1.4.1.7309.4.1.5.8.1 integer read-only
Number of misc alarm variables in system controller alarm table
                           dcPwrSysMiscAlrmTable 1.3.6.1.4.1.7309.4.1.5.8.2 no-access
A table of DC power system controller misc alarm variables
                               dcPwrSysMiscAlrmEntry 1.3.6.1.4.1.7309.4.1.5.8.2.1 no-access
An entry into the DC power system controller misc alarm group
                                   dcPwrSysMiscAlrmIndex 1.3.6.1.4.1.7309.4.1.5.8.2.1.1 integer read-only
The index of the alarm variable in the DC power system controller table misc alarm group
                                   dcPwrSysMiscAlrmName 1.3.6.1.4.1.7309.4.1.5.8.2.1.2 displaystring read-only
The description of the alarm variable as reported by the DC power system controller misc alarm group
                                   dcPwrSysMiscAlrmIntegerValue 1.3.6.1.4.1.7309.4.1.5.8.2.1.3 integer read-only
The integer value of the alarm variable as reported by the DC power system controller misc alarm group
                                   dcPwrSysMiscAlrmStringValue 1.3.6.1.4.1.7309.4.1.5.8.2.1.4 displaystring read-only
The string value of the alarm variable as reported by the DC power system controller misc alarm group
                                   dcPwrSysMiscAlrmSeverity 1.3.6.1.4.1.7309.4.1.5.8.2.1.5 integer read-only
The integer value of alarm severity level of the extra variable as reported by the DC power system controller misc alarm group
                       dcPwrSysCtrlAlrmTbl 1.3.6.1.4.1.7309.4.1.5.9
                           dcPwrSysCtrlAlrmCount 1.3.6.1.4.1.7309.4.1.5.9.1 integer read-only
Number of control alarm variables in system controller alarm table
                           dcPwrSysCtrlAlrmTable 1.3.6.1.4.1.7309.4.1.5.9.2 no-access
A table of DC power system controller control alarm variables
                               dcPwrSysCtrlAlrmEntry 1.3.6.1.4.1.7309.4.1.5.9.2.1 no-access
An entry into the DC power system controller control alarm group
                                   dcPwrSysCtrlAlrmIndex 1.3.6.1.4.1.7309.4.1.5.9.2.1.1 integer read-only
The index of the alarm variable in the DC power system controller table control alarm group
                                   dcPwrSysCtrlAlrmName 1.3.6.1.4.1.7309.4.1.5.9.2.1.2 displaystring read-only
The description of the alarm variable as reported by the DC power system controller control alarm group
                                   dcPwrSysCtrlAlrmIntegerValue 1.3.6.1.4.1.7309.4.1.5.9.2.1.3 integer read-only
The integer value of the alarm variable as reported by the DC power system controller control alarm group
                                   dcPwrSysCtrlAlrmStringValue 1.3.6.1.4.1.7309.4.1.5.9.2.1.4 displaystring read-only
The string value of the alarm variable as reported by the DC power system controller control alarm group
                                   dcPwrSysCtrlAlrmSeverity 1.3.6.1.4.1.7309.4.1.5.9.2.1.5 integer read-only
The integer value of alarm severity level of the extra variable as reported by the DC power system controller control alarm group
                       dcPwrSysAdioAlrmTbl 1.3.6.1.4.1.7309.4.1.5.10
                             dcPwrSysAdioAlrmCount 1.3.6.1.4.1.7309.4.1.5.10.1 integer read-only
Number of control alarm variables in Adio alarm table
                             dcPwrSysAdioAlrmTable 1.3.6.1.4.1.7309.4.1.5.10.2 no-access
A table of DC power system controller Adio alarm variables
                                 dcPwrSysAdioAlrmEntry 1.3.6.1.4.1.7309.4.1.5.10.2.1 no-access
An entry into the DC power system controller Adio alarm group
                                     dcPwrSysAdioAlrmIndex 1.3.6.1.4.1.7309.4.1.5.10.2.1.1 integer read-only
The index of the alarm variable in the DC power system controller table Adio alarm group
                                     dcPwrSysAdioAlrmName 1.3.6.1.4.1.7309.4.1.5.10.2.1.2 displaystring read-only
The description of the alarm variable as reported by the DC power system controller Adio alarm group
                                     dcPwrSysAdioAlrmIntegerValue 1.3.6.1.4.1.7309.4.1.5.10.2.1.3 integer read-only
The integer value of the alarm variable as reported by the DC power system controller Adio alarm group
                                     dcPwrSysAdioAlrmStringValue 1.3.6.1.4.1.7309.4.1.5.10.2.1.4 displaystring read-only
The string value of the alarm variable as reported by the DC power system controller Adio alarm group
                                     dcPwrSysAdioAlrmSeverity 1.3.6.1.4.1.7309.4.1.5.10.2.1.5 integer read-only
The integer value of alarm severity level of the extra variable as reported by the DC Adio system controller control alarm group
                       dcPwrSysConvAlrmTbl 1.3.6.1.4.1.7309.4.1.5.11
                             dcPwrSysConvAlrmCount 1.3.6.1.4.1.7309.4.1.5.11.1 integer read-only
Number of Converter alarm variables in system controller alarm table
                             dcPwrSysConvAlrmTable 1.3.6.1.4.1.7309.4.1.5.11.2 no-access
A table of DC power system controller Converter alarm variables
                                 dcPwrSysConvAlrmEntry 1.3.6.1.4.1.7309.4.1.5.11.2.1 no-access
An entry into the DC power system controller Converter alarm group
                                     dcPwrSysConvAlrmIndex 1.3.6.1.4.1.7309.4.1.5.11.2.1.1 integer read-only
The index of the alarm variable in the DC power system controller table Converter alarm group
                                     dcPwrSysConvAlrmName 1.3.6.1.4.1.7309.4.1.5.11.2.1.2 displaystring read-only
The description of the alarm variable as reported by the DC power system controller Converter alarm group
                                     dcPwrSysConvAlrmIntegerValue 1.3.6.1.4.1.7309.4.1.5.11.2.1.3 integer read-only
The integer value of the alarm variable as reported by the DC power system controller Converter alarm group
                                     dcPwrSysConvAlrmStringValue 1.3.6.1.4.1.7309.4.1.5.11.2.1.4 displaystring read-only
The string value of the alarm variable as reported by the DC power system controller Converter alarm group
                                     dcPwrSysConvAlrmSeverity 1.3.6.1.4.1.7309.4.1.5.11.2.1.5 integer read-only
The integer value of alarm severity level of the extra variable as reported by the DC power system controller Converter alarm group
                   dcPwrSysInputsTbl 1.3.6.1.4.1.7309.4.1.6
                       dcPwrSysDigIpTbl 1.3.6.1.4.1.7309.4.1.6.1
                           dcPwrSysDigIpCount 1.3.6.1.4.1.7309.4.1.6.1.1 integer read-only
Number of digital input variables in system controller digital input table
                           dcPwrSysDigIpTable 1.3.6.1.4.1.7309.4.1.6.1.2 no-access
A table of DC power system controller digital input variables
                               dcPwrSysDigIpEntry 1.3.6.1.4.1.7309.4.1.6.1.2.1 no-access
An entry into the DC power system controller digital input group
                                   dcPwrSysDigIpIndex 1.3.6.1.4.1.7309.4.1.6.1.2.1.1 integer read-only
The index of the digital input variable in the DC power system controller table digital input group
                                   dcPwrSysDigIpName 1.3.6.1.4.1.7309.4.1.6.1.2.1.2 displaystring read-only
The description of the digital input variable as reported by the DC power system controller digital input group
                                   dcPwrSysDigIpIntegerValue 1.3.6.1.4.1.7309.4.1.6.1.2.1.3 integer read-only
The integer value of the digital input variable as reported by the DC power system controller digital input group
                                   dcPwrSysDigIpStringValue 1.3.6.1.4.1.7309.4.1.6.1.2.1.4 displaystring read-only
The string value of the digital input variable as reported by the DC power system controller digital input group
                       dcPwrSysCntrlrIpTbl 1.3.6.1.4.1.7309.4.1.6.2
                           dcPwrSysCntrlrIpCount 1.3.6.1.4.1.7309.4.1.6.2.1 integer read-only
Number of controller input variables in system controller controller input table
                           dcPwrSysCntrlrIpTable 1.3.6.1.4.1.7309.4.1.6.2.2 no-access
A table of DC power system controller controller input variables
                               dcPwrSysCntrlrIpEntry 1.3.6.1.4.1.7309.4.1.6.2.2.1 no-access
An entry into the DC power system controller controller input group
                                   dcPwrSysCntrlrIpIndex 1.3.6.1.4.1.7309.4.1.6.2.2.1.1 integer read-only
The index of the controller input variable in the DC power system controller table controller input group
                                   dcPwrSysCntrlrIpName 1.3.6.1.4.1.7309.4.1.6.2.2.1.2 displaystring read-only
The description of the controller input variable as reported by the DC power system controller controller input group
                                   dcPwrSysCntrlrIpIntegerValue 1.3.6.1.4.1.7309.4.1.6.2.2.1.3 integer read-only
The integer value of the controller input variable as reported by the DC power system controller controller input group
                                   dcPwrSysCntrlrIpStringValue 1.3.6.1.4.1.7309.4.1.6.2.2.1.4 displaystring read-only
The string value of the controller input variable as reported by the DC power system controller controller input group
                       dcPwrSysRectIpTbl 1.3.6.1.4.1.7309.4.1.6.3
                           dcPwrSysRectIpCount 1.3.6.1.4.1.7309.4.1.6.3.1 integer read-only
Number of rectifier input variables in system controller rectifier input table
                           dcPwrSysRectIpTable 1.3.6.1.4.1.7309.4.1.6.3.2 no-access
A table of DC power system controller rectifier input variables
                               dcPwrSysRectIpEntry 1.3.6.1.4.1.7309.4.1.6.3.2.1 no-access
An entry into the DC power system controller rectifier input group
                                   dcPwrSysRectIpIndex 1.3.6.1.4.1.7309.4.1.6.3.2.1.1 integer read-only
The index of the rectifier input variable in the DC power system controller table rectifier input group
                                   dcPwrSysRectIpName 1.3.6.1.4.1.7309.4.1.6.3.2.1.2 displaystring read-only
The description of the rectifier input variable as reported by the DC power system controller rectifier input group
                                   dcPwrSysRectIpIntegerValue 1.3.6.1.4.1.7309.4.1.6.3.2.1.3 integer read-only
The integer value of the rectifier input variable as reported by the DC power system controller rectifier input group
                                   dcPwrSysRectIpStringValue 1.3.6.1.4.1.7309.4.1.6.3.2.1.4 displaystring read-only
The string value of the rectifier input variable as reported by the DC power system controller rectifier input group
                       dcPwrSysCustomIpTbl 1.3.6.1.4.1.7309.4.1.6.4
                           dcPwrSysCustomIpCount 1.3.6.1.4.1.7309.4.1.6.4.1 integer read-only
Number of custom input variables in system controller custom input table
                           dcPwrSysCustomIpTable 1.3.6.1.4.1.7309.4.1.6.4.2 no-access
A table of DC power system controller digital custom variables
                               dcPwrSysCustomIpEntry 1.3.6.1.4.1.7309.4.1.6.4.2.1 no-access
An entry into the DC power system controller custom input group
                                   dcPwrSysCustomIpIndex 1.3.6.1.4.1.7309.4.1.6.4.2.1.1 integer read-only
The index of the custom input variable in the DC power system controller table custom input group
                                   dcPwrSysCustomIpName 1.3.6.1.4.1.7309.4.1.6.4.2.1.2 displaystring read-only
The description of the custom input variable as reported by the DC power system controller custom input group
                                   dcPwrSysgCustomIpIntegerValue 1.3.6.1.4.1.7309.4.1.6.4.2.1.3 integer read-only
The integer value of the custom input variable as reported by the DC power system controller custom input group
                                   dcPwrSysCustomIpStringValue 1.3.6.1.4.1.7309.4.1.6.4.2.1.4 displaystring read-only
The string value of the custom input variable as reported by the DC power system controller custom input group
                       dcPwrSysConvIpTbl 1.3.6.1.4.1.7309.4.1.6.5
                           dcPwrSysConvIpCount 1.3.6.1.4.1.7309.4.1.6.5.1 integer read-only
Number of Converter input variables in system controller Converter input table
                           dcPwrSysConvIpTable 1.3.6.1.4.1.7309.4.1.6.5.2 no-access
A table of DC power system controller Converter input variables
                               dcPwrSysConvIpEntry 1.3.6.1.4.1.7309.4.1.6.5.2.1 no-access
An entry into the DC power system controller Converter input group
                                   dcPwrSysConvIpIndex 1.3.6.1.4.1.7309.4.1.6.5.2.1.1 integer read-only
The index of the Converter input variable in the DC power system controller table Converter input group
                                   dcPwrSysConvIpName 1.3.6.1.4.1.7309.4.1.6.5.2.1.2 displaystring read-only
The description of the Converter input variable as reported by the DC power system controller Converter input group
                                   dcPwrSysConvIpIntegerValue 1.3.6.1.4.1.7309.4.1.6.5.2.1.3 integer read-only
The integer value of the Converter input variable as reported by the DC power system controller Converter input group
                                   dcPwrSysConvIpStringValue 1.3.6.1.4.1.7309.4.1.6.5.2.1.4 displaystring read-only
The string value of the Converter input variable as reported by the DC power system controller Converter input group
                       dcPwrSysTimerIpTbl 1.3.6.1.4.1.7309.4.1.6.6
                           dcPwrSysTimerIpCount 1.3.6.1.4.1.7309.4.1.6.6.1 integer read-only
Number of Timererter input variables in system controller Timererter input table
                           dcPwrSysTimerIpTable 1.3.6.1.4.1.7309.4.1.6.6.2 no-access
A table of DC power system controller Timererter input variables
                               dcPwrSysTimerIpEntry 1.3.6.1.4.1.7309.4.1.6.6.2.1 no-access
An entry into the DC power system controller Timererter input group
                                   dcPwrSysTimerIpIndex 1.3.6.1.4.1.7309.4.1.6.6.2.1.1 integer read-only
The index of the Timererter input variable in the DC power system controller table Timererter input group
                                   dcPwrSysTimerIpName 1.3.6.1.4.1.7309.4.1.6.6.2.1.2 displaystring read-only
The description of the Timererter input variable as reported by the DC power system controller Timererter input group
                                   dcPwrSysTimerIpIntegerValue 1.3.6.1.4.1.7309.4.1.6.6.2.1.3 integer read-only
The integer value of the Timererter input variable as reported by the DC power system controller Timererter input group
                                   dcPwrSysTimerIpStringValue 1.3.6.1.4.1.7309.4.1.6.6.2.1.4 displaystring read-only
The string value of the Timererter input variable as reported by the DC power system controller Timererter input group
                       dcPwrSysCounterIpTbl 1.3.6.1.4.1.7309.4.1.6.7
                           dcPwrSysCounterIpCount 1.3.6.1.4.1.7309.4.1.6.7.1 integer read-only
Number of Countererter input variables in system controller Countererter input table
                           dcPwrSysCounterIpTable 1.3.6.1.4.1.7309.4.1.6.7.2 no-access
A table of DC power system controller Countererter input variables
                               dcPwrSysCounterIpEntry 1.3.6.1.4.1.7309.4.1.6.7.2.1 no-access
An entry into the DC power system controller Countererter input group
                                   dcPwrSysCounterIpIndex 1.3.6.1.4.1.7309.4.1.6.7.2.1.1 integer read-only
The index of the Countererter input variable in the DC power system controller table Countererter input group
                                   dcPwrSysCounterIpName 1.3.6.1.4.1.7309.4.1.6.7.2.1.2 displaystring read-only
The description of the Countererter input variable as reported by the DC power system controller Countererter input group
                                   dcPwrSysCounterIpIntegerValue 1.3.6.1.4.1.7309.4.1.6.7.2.1.3 integer read-only
The integer value of the Countererter input variable as reported by the DC power system controller Countererter input group
                                   dcPwrSysCounterIpStringValue 1.3.6.1.4.1.7309.4.1.6.7.2.1.4 displaystring read-only
The string value of the Countererter input variable as reported by the DC power system controller Countererter input group
                   dcPwrExternalControls 1.3.6.1.4.1.7309.4.1.8
                       dcPwrSysResyncAlarms 1.3.6.1.4.1.7309.4.1.8.1 integer read-write
Send/Resend all active alarms that were previously sent through SNMP notification.
                   dcPwrVarbindNameReference 1.3.6.1.4.1.7309.4.1.9
                       dcPwrSysAlarmTriggerValue 1.3.6.1.4.1.7309.4.1.9.1 integer read-only
                       dcPwrSysTimeStamp 1.3.6.1.4.1.7309.4.1.9.2 displaystring read-only