Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
 flash 1.3.6.1.4.1.207.8.4.4.4.31
This MIB file contains definitions of managed objects for the FLASH module.
       flashTrap 1.3.6.1.4.1.207.8.4.4.4.31.0
           flashFailureTrap 1.3.6.1.4.1.207.8.4.4.4.31.0.1
A flash failure trap is generated when any of the above flash counter is incremented and the failure type is sent in the trap.
       flashGetFailure 1.3.6.1.4.1.207.8.4.4.4.31.1 integer read-only
The number of flash get operations that have failed.
       flashOpenFailure 1.3.6.1.4.1.207.8.4.4.4.31.2 integer read-only
The number of flash open operations that have failed.
       flashReadFailure 1.3.6.1.4.1.207.8.4.4.4.31.3 integer read-only
The number of flash read operations that have failed.
       flashCloseFailure 1.3.6.1.4.1.207.8.4.4.4.31.4 integer read-only
The number of flash close operations that have failed.
       flashCompleteFailure 1.3.6.1.4.1.207.8.4.4.4.31.5 integer read-only
The number of flash complete operations that have failed.
       flashWriteFailure 1.3.6.1.4.1.207.8.4.4.4.31.6 integer read-only
The number of flash write operations that have failed.
       flashCreateFailure 1.3.6.1.4.1.207.8.4.4.4.31.7 integer read-only
The number of flash create operations that have failed.
       flashPutFailure 1.3.6.1.4.1.207.8.4.4.4.31.8 integer read-only
The number of flash put operations that have failed.
       flashDeleteFailure 1.3.6.1.4.1.207.8.4.4.4.31.9 integer read-only
The number of flash delete operations that have failed.
       flashCheckFailure 1.3.6.1.4.1.207.8.4.4.4.31.10 integer read-only
The number of flash check operations that have failed.
       flashEraseFailure 1.3.6.1.4.1.207.8.4.4.4.31.11 integer read-only
The number of flash erase operations that have failed.
       flashCompactFailure 1.3.6.1.4.1.207.8.4.4.4.31.12 integer read-only
The number of flash compaction operations that have failed.
       flashVerifyFailure 1.3.6.1.4.1.207.8.4.4.4.31.13 integer read-only
The number of flash verify operations that have failed.