ARRIS-C3-FPD-MIB: View SNMP OID List / Download MIB

VENDOR: ARRIS INTERACTIVE LLC


 Home MIB: ARRIS-C3-FPD-MIB
Download as:   

Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
 cmtsC3FPDMIB 1.3.6.1.4.1.4115.1.4.3.3
This MIB manages the Front Panel Display (FPD) software on the Arris CMTS C3
     dcxFPDObjects 1.3.6.1.4.1.4115.1.4.3.3.1
         dcxFPDMsgTable 1.3.6.1.4.1.4115.1.4.3.3.1.1 no-access
Table of Front Panel LCD Messages.
             dcxFPDMsgEntry 1.3.6.1.4.1.4115.1.4.3.3.1.1.1 no-access
.
                 dcxFPDMsgIndex 1.3.6.1.4.1.4115.1.4.3.3.1.1.1.1 unsigned32 no-access
Index used to order the FPD Messages.
                 dcxFPDMsgString 1.3.6.1.4.1.4115.1.4.3.3.1.1.1.2 octet string read-write
Specifies a string that can be displayed on the front panel.
         dcxFPDControlGroup 1.3.6.1.4.1.4115.1.4.3.3.1.2
             dcxFPDAttachedStatus 1.3.6.1.4.1.4115.1.4.3.3.1.2.1 integer read-only
Displays if the front panel display is attached to the Cmts or not. Enumeration: 'detached': 2, 'attached': 1.
             dcxFPDPowerStatus1 1.3.6.1.4.1.4115.1.4.3.3.1.2.2 integer read-only
Specifies if the primary power supply is working. This is the rightmost power supply. The following values are possible: on(1) and off(2) Enumeration: 'on': 1, 'off': 2.
             dcxFPDPowerStatus2 1.3.6.1.4.1.4115.1.4.3.3.1.2.3 integer read-only
Specifies if the secondary power supply is working. This is the leftmost power supply(nearest the fan tray). The following values are possible: on(1) and off(2) Enumeration: 'on': 1, 'off': 2.
             dcxFPDTemp1Status 1.3.6.1.4.1.4115.1.4.3.3.1.2.4 integer32 read-only
Specifies the temperature reading for the sensor on the CPU card closest to the CPU.
             dcxFPDTemp2Status 1.3.6.1.4.1.4115.1.4.3.3.1.2.5 integer32 read-only
Specifies the temperature reading for the sensor on the CPU card, on the right hand side.
             dcxFPDTemp3Status 1.3.6.1.4.1.4115.1.4.3.3.1.2.6 integer32 read-only
Specifies the temperature reading for the sensor on the Kanga card under the Roo cards between RX4 and RX5.
             dcxFPDTemp4Status 1.3.6.1.4.1.4115.1.4.3.3.1.2.7 integer32 read-only
Specifies the temperature reading for the sensor on the Kanga card under the Roo cards between RX2 and RX3.
             dcxFPDFan1Status 1.3.6.1.4.1.4115.1.4.3.3.1.2.8 integer read-only
Specifies the fan status for the fan nearest the front of the box. The following values are possible: Rotating(1) and BadRotating(2). BadRotating is set when the fan is operating outside of dcxFPDFanUpperLimit and dcxFPDFanLowerLimit. Enumeration: 'rotating': 1, 'badRotating': 2.
             dcxFPDFan2Status 1.3.6.1.4.1.4115.1.4.3.3.1.2.9 integer read-only
Specifies the fan status for the fan 2nd from the front. The following values are possible: Rotating(1) and BadRotating(2). BadRotating is set when the fan is operating outside of dcxFPDFanUpperLimit and dcxFPDFanLowerLimit. Enumeration: 'rotating': 1, 'badRotating': 2.
             dcxFPDFan3Status 1.3.6.1.4.1.4115.1.4.3.3.1.2.10 integer read-only
Specifies the fan status for the fan 3rd from the front. The following values are possible: Rotating(1) and BadRotating(2). BadRotating is set when the fan is operating outside of dcxFPDFanUpperLimit and dcxFPDFanLowerLimit. Enumeration: 'rotating': 1, 'badRotating': 2.
             dcxFPDFan4Status 1.3.6.1.4.1.4115.1.4.3.3.1.2.11 integer read-only
Specifies the fan status for the fan 4th from the front. The following values are possible: Rotating(1) and BadRotating(2). BadRotating is set when the fan is operating outside of dcxFPDFanUpperLimit and dcxFPDFanLowerLimit. Enumeration: 'rotating': 1, 'badRotating': 2.
             dcxFPDFan5Status 1.3.6.1.4.1.4115.1.4.3.3.1.2.12 integer read-only
Specifies the fan status for the fan 5th from the front. The following values are possible: Rotating(1) and BadRotating(2). BadRotating is set when the fan is operating outside of dcxFPDFanUpperLimit and dcxFPDFanLowerLimit. Enumeration: 'rotating': 1, 'badRotating': 2.
             dcxFPDFan6Status 1.3.6.1.4.1.4115.1.4.3.3.1.2.13 integer read-only
Specifies the fan status for the fan nearest the back of the box The following values are possible: Rotating(1) and BadRotating(2). BadRotating is set when the fan is operating outside of dcxFPDFanUpperLimit and dcxFPDFanLowerLimit. Enumeration: 'rotating': 1, 'badRotating': 2.
             dcxFPDFanUpperLimit 1.3.6.1.4.1.4115.1.4.3.3.1.2.14 integer32 read-write
Specifies the upper fan limit(Upper threshold of expected current draw)
             dcxFPDFanLowerLimit 1.3.6.1.4.1.4115.1.4.3.3.1.2.15 integer32 read-write
Specifies the lower fan limit(Lower threshold of expected current draw)
             dcxFPDLCDContrast 1.3.6.1.4.1.4115.1.4.3.3.1.2.16 integer32 read-write
Specifies the contrast level for the LCD
             dcxFPDLedSetStatus 1.3.6.1.4.1.4115.1.4.3.3.1.2.17 integer32 read-write
Used to turn on or off a Led on the front panel
             dcxFPDHwRevision 1.3.6.1.4.1.4115.1.4.3.3.1.2.18 integer32 read-only
Specifies the front panel h/w revision
             dcxFPDSwRevision 1.3.6.1.4.1.4115.1.4.3.3.1.2.19 integer32 read-only
Specifies the front panel s/w revision
         dcxFPDTrapGroup 1.3.6.1.4.1.4115.1.4.3.3.1.3
             dcxFPDAttached 1.3.6.1.4.1.4115.1.4.3.3.1.3.1
Front Panel Display has been attached.
             dcxFPDDetached 1.3.6.1.4.1.4115.1.4.3.3.1.3.2
Front Panel Display has been detached.
             dcxFPDFan1Fail 1.3.6.1.4.1.4115.1.4.3.3.1.3.3
Fan nearest the front of the box failed
             dcxFPDFan1FailClr 1.3.6.1.4.1.4115.1.4.3.3.1.3.4
Fan nearest the front of the box is working
             dcxFPDFan2Fail 1.3.6.1.4.1.4115.1.4.3.3.1.3.5
Fan 2nd from the front failed
             dcxFPDFan2FailClr 1.3.6.1.4.1.4115.1.4.3.3.1.3.6
Fan 2nd from the front is working
             dcxFPDFan3Fail 1.3.6.1.4.1.4115.1.4.3.3.1.3.7
Fan 3rd from the front failed
             dcxFPDFan3FailClr 1.3.6.1.4.1.4115.1.4.3.3.1.3.8
Fan 3rd from the front is working
             dcxFPDFan4Fail 1.3.6.1.4.1.4115.1.4.3.3.1.3.9
Fan 4th from the front failed
             dcxFPDFan4FailClr 1.3.6.1.4.1.4115.1.4.3.3.1.3.10
Fan 4th from the front is working
             dcxFPDFan5Fail 1.3.6.1.4.1.4115.1.4.3.3.1.3.11
Fan 5th from the front failed
             dcxFPDFan5FailClr 1.3.6.1.4.1.4115.1.4.3.3.1.3.12
Fan 5th from the front is working
             dcxFPDFan6Fail 1.3.6.1.4.1.4115.1.4.3.3.1.3.13
Fan nearest the back of the box failed
             dcxFPDFan6FailClr 1.3.6.1.4.1.4115.1.4.3.3.1.3.14
Fan nearest the back of the box is working
             dcxFPDPwr1Fail 1.3.6.1.4.1.4115.1.4.3.3.1.3.15
Rightmost power supply failed
             dcxFPDPwr1FailClr 1.3.6.1.4.1.4115.1.4.3.3.1.3.16
Rightmost power supply is working
             dcxFPDPwr2Fail 1.3.6.1.4.1.4115.1.4.3.3.1.3.17
Leftmost power supply failed
             dcxFPDPwr2FailClr 1.3.6.1.4.1.4115.1.4.3.3.1.3.18
Leftmost power supply is working
             dcxFPDTempOkay 1.3.6.1.4.1.4115.1.4.3.3.1.3.19
System temperature is OK
             dcxFPDTempBad 1.3.6.1.4.1.4115.1.4.3.3.1.3.20
System temperature is too hot!
             dcxFPDTempCritical 1.3.6.1.4.1.4115.1.4.3.3.1.3.21
System temperature is critical!!!, CMTS will shut itself down!!!!
         dcxFPDConformance 1.3.6.1.4.1.4115.1.4.3.3.1.4
             dcxFPDCompliances 1.3.6.1.4.1.4115.1.4.3.3.1.4.1
                 dcxFPDCompliance 1.3.6.1.4.1.4115.1.4.3.3.1.4.1.1
The compliance statement for devices that implement Arris C3 compliant FPD features
             dcxFPDGroups 1.3.6.1.4.1.4115.1.4.3.3.1.4.2
                 dcxFPDMsgGroup 1.3.6.1.4.1.4115.1.4.3.3.1.4.2.1
Arris C3 FPD message group
                 dcxFPDControlConfGroup 1.3.6.1.4.1.4115.1.4.3.3.1.4.2.2
Arris C3 FPD Control group