ARRIS-C3-FPD-MIB: View SNMP OID List / Download MIB
VENDOR: ARRIS INTERACTIVE LLC
Home | MIB: ARRIS-C3-FPD-MIB | |||
---|---|---|---|---|
Download as: |
Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
|
|||
Object Name | OID | Type | Access | Info |
cmtsC3FPDMIB | 1.3.6.1.4.1.4115.1.4.3.3 |
This MIB manages the Front Panel Display (FPD) software on the Arris CMTS C3 |
||
dcxFPDObjects | 1.3.6.1.4.1.4115.1.4.3.3.1 | |||
dcxFPDMsgTable | 1.3.6.1.4.1.4115.1.4.3.3.1.1 | no-access |
Table of Front Panel LCD Messages. |
|
1.3.6.1.4.1.4115.1.4.3.3.1.1.1 | no-access |
. |
||
dcxFPDMsgIndex | 1.3.6.1.4.1.4115.1.4.3.3.1.1.1.1 | unsigned32 | no-access |
Index used to order the FPD Messages. |
dcxFPDMsgString | 1.3.6.1.4.1.4115.1.4.3.3.1.1.1.2 | octet string | read-write |
Specifies a string that can be displayed on the front panel. |
dcxFPDControlGroup | 1.3.6.1.4.1.4115.1.4.3.3.1.2 | |||
dcxFPDAttachedStatus | 1.3.6.1.4.1.4115.1.4.3.3.1.2.1 | integer | read-only |
Displays if the front panel display is attached to the Cmts or not. Enumeration: 'detached': 2, 'attached': 1. |
dcxFPDPowerStatus1 | 1.3.6.1.4.1.4115.1.4.3.3.1.2.2 | integer | read-only |
Specifies if the primary power supply is working. This is the rightmost power supply. The following values are possible: on(1) and off(2) Enumeration: 'on': 1, 'off': 2. |
dcxFPDPowerStatus2 | 1.3.6.1.4.1.4115.1.4.3.3.1.2.3 | integer | read-only |
Specifies if the secondary power supply is working. This is the leftmost power supply(nearest the fan tray). The following values are possible: on(1) and off(2) Enumeration: 'on': 1, 'off': 2. |
dcxFPDTemp1Status | 1.3.6.1.4.1.4115.1.4.3.3.1.2.4 | integer32 | read-only |
Specifies the temperature reading for the sensor on the CPU card closest to the CPU. |
dcxFPDTemp2Status | 1.3.6.1.4.1.4115.1.4.3.3.1.2.5 | integer32 | read-only |
Specifies the temperature reading for the sensor on the CPU card, on the right hand side. |
dcxFPDTemp3Status | 1.3.6.1.4.1.4115.1.4.3.3.1.2.6 | integer32 | read-only |
Specifies the temperature reading for the sensor on the Kanga card under the Roo cards between RX4 and RX5. |
dcxFPDTemp4Status | 1.3.6.1.4.1.4115.1.4.3.3.1.2.7 | integer32 | read-only |
Specifies the temperature reading for the sensor on the Kanga card under the Roo cards between RX2 and RX3. |
dcxFPDFan1Status | 1.3.6.1.4.1.4115.1.4.3.3.1.2.8 | integer | read-only |
Specifies the fan status for the fan nearest the front of the box. The following values are possible: Rotating(1) and BadRotating(2). BadRotating is set when the fan is operating outside of dcxFPDFanUpperLimit and dcxFPDFanLowerLimit. Enumeration: 'rotating': 1, 'badRotating': 2. |
dcxFPDFan2Status | 1.3.6.1.4.1.4115.1.4.3.3.1.2.9 | integer | read-only |
Specifies the fan status for the fan 2nd from the front. The following values are possible: Rotating(1) and BadRotating(2). BadRotating is set when the fan is operating outside of dcxFPDFanUpperLimit and dcxFPDFanLowerLimit. Enumeration: 'rotating': 1, 'badRotating': 2. |
dcxFPDFan3Status | 1.3.6.1.4.1.4115.1.4.3.3.1.2.10 | integer | read-only |
Specifies the fan status for the fan 3rd from the front. The following values are possible: Rotating(1) and BadRotating(2). BadRotating is set when the fan is operating outside of dcxFPDFanUpperLimit and dcxFPDFanLowerLimit. Enumeration: 'rotating': 1, 'badRotating': 2. |
dcxFPDFan4Status | 1.3.6.1.4.1.4115.1.4.3.3.1.2.11 | integer | read-only |
Specifies the fan status for the fan 4th from the front. The following values are possible: Rotating(1) and BadRotating(2). BadRotating is set when the fan is operating outside of dcxFPDFanUpperLimit and dcxFPDFanLowerLimit. Enumeration: 'rotating': 1, 'badRotating': 2. |
dcxFPDFan5Status | 1.3.6.1.4.1.4115.1.4.3.3.1.2.12 | integer | read-only |
Specifies the fan status for the fan 5th from the front. The following values are possible: Rotating(1) and BadRotating(2). BadRotating is set when the fan is operating outside of dcxFPDFanUpperLimit and dcxFPDFanLowerLimit. Enumeration: 'rotating': 1, 'badRotating': 2. |
dcxFPDFan6Status | 1.3.6.1.4.1.4115.1.4.3.3.1.2.13 | integer | read-only |
Specifies the fan status for the fan nearest the back of the box The following values are possible: Rotating(1) and BadRotating(2). BadRotating is set when the fan is operating outside of dcxFPDFanUpperLimit and dcxFPDFanLowerLimit. Enumeration: 'rotating': 1, 'badRotating': 2. |
dcxFPDFanUpperLimit | 1.3.6.1.4.1.4115.1.4.3.3.1.2.14 | integer32 | read-write |
Specifies the upper fan limit(Upper threshold of expected current draw) |
dcxFPDFanLowerLimit | 1.3.6.1.4.1.4115.1.4.3.3.1.2.15 | integer32 | read-write |
Specifies the lower fan limit(Lower threshold of expected current draw) |
dcxFPDLCDContrast | 1.3.6.1.4.1.4115.1.4.3.3.1.2.16 | integer32 | read-write |
Specifies the contrast level for the LCD |
dcxFPDLedSetStatus | 1.3.6.1.4.1.4115.1.4.3.3.1.2.17 | integer32 | read-write |
Used to turn on or off a Led on the front panel |
dcxFPDHwRevision | 1.3.6.1.4.1.4115.1.4.3.3.1.2.18 | integer32 | read-only |
Specifies the front panel h/w revision |
dcxFPDSwRevision | 1.3.6.1.4.1.4115.1.4.3.3.1.2.19 | integer32 | read-only |
Specifies the front panel s/w revision |
dcxFPDTrapGroup | 1.3.6.1.4.1.4115.1.4.3.3.1.3 | |||
dcxFPDAttached | 1.3.6.1.4.1.4115.1.4.3.3.1.3.1 |
Front Panel Display has been attached. |
||
dcxFPDDetached | 1.3.6.1.4.1.4115.1.4.3.3.1.3.2 |
Front Panel Display has been detached. |
||
dcxFPDFan1Fail | 1.3.6.1.4.1.4115.1.4.3.3.1.3.3 |
Fan nearest the front of the box failed |
||
dcxFPDFan1FailClr | 1.3.6.1.4.1.4115.1.4.3.3.1.3.4 |
Fan nearest the front of the box is working |
||
dcxFPDFan2Fail | 1.3.6.1.4.1.4115.1.4.3.3.1.3.5 |
Fan 2nd from the front failed |
||
dcxFPDFan2FailClr | 1.3.6.1.4.1.4115.1.4.3.3.1.3.6 |
Fan 2nd from the front is working |
||
dcxFPDFan3Fail | 1.3.6.1.4.1.4115.1.4.3.3.1.3.7 |
Fan 3rd from the front failed |
||
dcxFPDFan3FailClr | 1.3.6.1.4.1.4115.1.4.3.3.1.3.8 |
Fan 3rd from the front is working |
||
dcxFPDFan4Fail | 1.3.6.1.4.1.4115.1.4.3.3.1.3.9 |
Fan 4th from the front failed |
||
dcxFPDFan4FailClr | 1.3.6.1.4.1.4115.1.4.3.3.1.3.10 |
Fan 4th from the front is working |
||
dcxFPDFan5Fail | 1.3.6.1.4.1.4115.1.4.3.3.1.3.11 |
Fan 5th from the front failed |
||
dcxFPDFan5FailClr | 1.3.6.1.4.1.4115.1.4.3.3.1.3.12 |
Fan 5th from the front is working |
||
dcxFPDFan6Fail | 1.3.6.1.4.1.4115.1.4.3.3.1.3.13 |
Fan nearest the back of the box failed |
||
dcxFPDFan6FailClr | 1.3.6.1.4.1.4115.1.4.3.3.1.3.14 |
Fan nearest the back of the box is working |
||
dcxFPDPwr1Fail | 1.3.6.1.4.1.4115.1.4.3.3.1.3.15 |
Rightmost power supply failed |
||
dcxFPDPwr1FailClr | 1.3.6.1.4.1.4115.1.4.3.3.1.3.16 |
Rightmost power supply is working |
||
dcxFPDPwr2Fail | 1.3.6.1.4.1.4115.1.4.3.3.1.3.17 |
Leftmost power supply failed |
||
dcxFPDPwr2FailClr | 1.3.6.1.4.1.4115.1.4.3.3.1.3.18 |
Leftmost power supply is working |
||
dcxFPDTempOkay | 1.3.6.1.4.1.4115.1.4.3.3.1.3.19 |
System temperature is OK |
||
dcxFPDTempBad | 1.3.6.1.4.1.4115.1.4.3.3.1.3.20 |
System temperature is too hot! |
||
dcxFPDTempCritical | 1.3.6.1.4.1.4115.1.4.3.3.1.3.21 |
System temperature is critical!!!, CMTS will shut itself down!!!! |
||
dcxFPDConformance | 1.3.6.1.4.1.4115.1.4.3.3.1.4 | |||
dcxFPDCompliances | 1.3.6.1.4.1.4115.1.4.3.3.1.4.1 | |||
dcxFPDCompliance | 1.3.6.1.4.1.4115.1.4.3.3.1.4.1.1 |
The compliance statement for devices that implement Arris C3 compliant FPD features |
||
dcxFPDGroups | 1.3.6.1.4.1.4115.1.4.3.3.1.4.2 | |||
dcxFPDMsgGroup | 1.3.6.1.4.1.4115.1.4.3.3.1.4.2.1 |
Arris C3 FPD message group |
||
dcxFPDControlConfGroup | 1.3.6.1.4.1.4115.1.4.3.3.1.4.2.2 |
Arris C3 FPD Control group |