Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
 altigaHardwareStatsMibModule 1.3.6.1.4.1.3076.1.1.27.2
The Altiga Hardware Statistics MIB models counters and objects that are of management interest for the hardware. Acronyms The following acronyms are used in this document: CPU: Central Processing Unit MB: Megabyte MIB: Management Information Base PS: Power Supply RPM: Revolutions Per Minute SEP: Scalable Encryption Processor WAN: Wide Area Network
     altigaHardwareStatsMibConformance 1.3.6.1.4.1.3076.1.1.27.2.1
         altigaHardwareStatsMibCompliances 1.3.6.1.4.1.3076.1.1.27.2.1.1
             altigaHardwareStatsMibCompliance 1.3.6.1.4.1.3076.1.1.27.2.1.1.1
The compliance statement for agents which implement the Altiga Hardware Statistics MIB.
         altigaHardwareStatsGroup 1.3.6.1.4.1.3076.2.1.1.1.22.2
The objects for Hardware statistics.
     alStatsHardwareGlobal 1.3.6.1.4.1.3076.2.1.2.22.1
         alHardwareCpuVoltage 1.3.6.1.4.1.3076.2.1.2.22.1.1 gauge32 read-only
The current CPU voltage in centivolts.
         alHardwareCpuVoltageAlarm 1.3.6.1.4.1.3076.2.1.2.22.1.2 truthvalue read-only
The alarm status for CPU voltage. This alarm will fired when the CPU voltage is detected out of configured range.
         alHardwareCpuVoltageCount 1.3.6.1.4.1.3076.2.1.2.22.1.3 counter32 read-only
The number of alarm events for CPU voltage.
         alHardwareCpuVoltageTime 1.3.6.1.4.1.3076.2.1.2.22.1.4 timeticks read-only
The sysUptime at the time of the last change of alarm status for CPU voltage.
         alHardwarePs1Voltage3v 1.3.6.1.4.1.3076.2.1.2.22.1.5 gauge32 read-only
The current 3V voltage of Power Supply 1 in centivolts.
         alHardwarePs1Voltage3vAlarm 1.3.6.1.4.1.3076.2.1.2.22.1.6 truthvalue read-only
The alarm status for PS1 3v voltage. This alarm will fired when the 3v power supply 1 voltage is detected out of configured range.
         alHardwarePs1Voltage3vCount 1.3.6.1.4.1.3076.2.1.2.22.1.7 counter32 read-only
The number of alarm events for PS1 3v voltage.
         alHardwarePs1Voltage3vTime 1.3.6.1.4.1.3076.2.1.2.22.1.8 timeticks read-only
The sysUptime at the time of the last change of alarm status for PS1 3v voltage.
         alHardwarePs1Voltage5v 1.3.6.1.4.1.3076.2.1.2.22.1.9 gauge32 read-only
The current 5V voltage of Power Supply 1 in centivolts.
         alHardwarePs1Voltage5vAlarm 1.3.6.1.4.1.3076.2.1.2.22.1.10 truthvalue read-only
The alarm status for PS1 5v voltage. This alarm will fired when the 5v power supply 1 voltage is detected out of configured range.
         alHardwarePs1Voltage5vCount 1.3.6.1.4.1.3076.2.1.2.22.1.11 counter32 read-only
The number of alarm events for PS1 5v voltage.
         alHardwarePs1Voltage5vTime 1.3.6.1.4.1.3076.2.1.2.22.1.12 timeticks read-only
The sysUptime at the time of the last change of alarm status for PS1 5v voltage.
         alHardwarePs2Voltage3v 1.3.6.1.4.1.3076.2.1.2.22.1.13 gauge32 read-only
The current 3V voltage of Power Supply 2 in centivolts.
         alHardwarePs2Voltage3vAlarm 1.3.6.1.4.1.3076.2.1.2.22.1.14 truthvalue read-only
The alarm status for PS2 3v voltage. This alarm will fired when the 3v power supply 2 voltage is detected out of configured range.
         alHardwarePs2Voltage3vCount 1.3.6.1.4.1.3076.2.1.2.22.1.15 counter32 read-only
The number of alarm events for PS2 3v voltage.
         alHardwarePs2Voltage3vTime 1.3.6.1.4.1.3076.2.1.2.22.1.16 timeticks read-only
The sysUptime at the time of the last change of alarm status for PS2 3v voltage.
         alHardwarePs2Voltage5v 1.3.6.1.4.1.3076.2.1.2.22.1.17 gauge32 read-only
The current 5V voltage of Power Supply 2 in centivolts.
         alHardwarePs2Voltage5vAlarm 1.3.6.1.4.1.3076.2.1.2.22.1.18 truthvalue read-only
The alarm status for PS2 5v voltage. This alarm will fired when the 5v power supply 2 voltage is detected out of configured range.
         alHardwarePs2Voltage5vCount 1.3.6.1.4.1.3076.2.1.2.22.1.19 counter32 read-only
The number of alarm events for PS2 5v voltage.
         alHardwarePs2Voltage5vTime 1.3.6.1.4.1.3076.2.1.2.22.1.20 timeticks read-only
The sysUptime at the time of the last change of alarm status for PS2 5v voltage.
         alHardwareBoardVoltage3v 1.3.6.1.4.1.3076.2.1.2.22.1.21 gauge32 read-only
The current 3V voltage of the mainboard in centivolts.
         alHardwareBoardVoltage3vAlarm 1.3.6.1.4.1.3076.2.1.2.22.1.22 truthvalue read-only
The alarm status for the mainboard 3v voltage. This alarm will fired when the 3v mainboard voltage is detected out of configured range.
         alHardwareBoardVoltage3vCount 1.3.6.1.4.1.3076.2.1.2.22.1.23 counter32 read-only
The number of alarm events for the mainboard 3v voltage.
         alHardwareBoardVoltage3vTime 1.3.6.1.4.1.3076.2.1.2.22.1.24 timeticks read-only
The sysUptime at the time of the last change of alarm status for the mainboard 3v voltage.
         alHardwareBoardVoltage5v 1.3.6.1.4.1.3076.2.1.2.22.1.25 gauge32 read-only
The current 5V voltage of the mainboard in centivolts.
         alHardwareBoardVoltage5vAlarm 1.3.6.1.4.1.3076.2.1.2.22.1.26 truthvalue read-only
The alarm status for the mainboard 5v voltage. This alarm will fired when the 5v mainboard voltage is detected out of configured range.
         alHardwareBoardVoltage5vCount 1.3.6.1.4.1.3076.2.1.2.22.1.27 counter32 read-only
The number of alarm events for the mainboard 5v voltage.
         alHardwareBoardVoltage5vTime 1.3.6.1.4.1.3076.2.1.2.22.1.28 timeticks read-only
The sysUptime at the time of the last change of alarm status for the mainboard 5v voltage.
         alHardwareCpuTemp 1.3.6.1.4.1.3076.2.1.2.22.1.29 integer32 read-only
The current CPU temperature in degrees C.
         alHardwareCpuTempAlarm 1.3.6.1.4.1.3076.2.1.2.22.1.30 truthvalue read-only
The alarm status for the CPU temperature. This alarm will fired when the CPU temperature is detected out of configured range.
         alHardwareCpuTempCount 1.3.6.1.4.1.3076.2.1.2.22.1.31 counter32 read-only
The number of alarm events for the CPU temperature.
         alHardwareCpuTempTime 1.3.6.1.4.1.3076.2.1.2.22.1.32 timeticks read-only
The sysUptime at the time of the last change of alarm status for the CPU temperature.
         alHardwareCageTemp 1.3.6.1.4.1.3076.2.1.2.22.1.33 integer32 read-only
The current cage temperature in degrees C.
         alHardwareCageTempAlarm 1.3.6.1.4.1.3076.2.1.2.22.1.34 truthvalue read-only
The alarm status for the cage temperature. This alarm will fired when the cage temperature is detected out of configured range.
         alHardwareCageTempCount 1.3.6.1.4.1.3076.2.1.2.22.1.35 counter32 read-only
The number of alarm events for the cage temperature.
         alHardwareCageTempTime 1.3.6.1.4.1.3076.2.1.2.22.1.36 timeticks read-only
The sysUptime at the time of the last change of alarm status for the cage temperature.
         alHardwareFan1Rpm 1.3.6.1.4.1.3076.2.1.2.22.1.37 gauge32 read-only
The current speed of fan 1 in RPM.
         alHardwareFan1RpmAlarm 1.3.6.1.4.1.3076.2.1.2.22.1.38 truthvalue read-only
The alarm status for fan 1 RPM. This alarm will fired when fan 1 RPM is detected out of configured range.
         alHardwareFan1RpmCount 1.3.6.1.4.1.3076.2.1.2.22.1.39 counter32 read-only
The number of alarm events for fan 1 RPM.
         alHardwareFan1RpmTime 1.3.6.1.4.1.3076.2.1.2.22.1.40 timeticks read-only
The sysUptime at the time of the last change of alarm status for fan 1 RPM.
         alHardwareFan2Rpm 1.3.6.1.4.1.3076.2.1.2.22.1.41 gauge32 read-only
The current speed of fan 2 in RPM.
         alHardwareFan2RpmAlarm 1.3.6.1.4.1.3076.2.1.2.22.1.42 truthvalue read-only
The alarm status for fan 2 RPM. This alarm will fired when fan 2 RPM is detected out of configured range.
         alHardwareFan2RpmCount 1.3.6.1.4.1.3076.2.1.2.22.1.43 counter32 read-only
The number of alarm events for fan 2 RPM.
         alHardwareFan2RpmTime 1.3.6.1.4.1.3076.2.1.2.22.1.44 timeticks read-only
The sysUptime at the time of the last change of alarm status for fan 2 RPM.
         alHardwareFan3Rpm 1.3.6.1.4.1.3076.2.1.2.22.1.45 gauge32 read-only
The current speed of fan 3 in RPM.
         alHardwareFan3RpmAlarm 1.3.6.1.4.1.3076.2.1.2.22.1.46 truthvalue read-only
The alarm status for fan 3 RPM. This alarm will fired when fan 3 RPM is detected out of configured range.
         alHardwareFan3RpmCount 1.3.6.1.4.1.3076.2.1.2.22.1.47 counter32 read-only
The number of alarm events for fan 3 RPM.
         alHardwareFan3RpmTime 1.3.6.1.4.1.3076.2.1.2.22.1.48 timeticks read-only
The sysUptime at the time of the last change of alarm status for fan 3 RPM.
         alHardwarePs1Type 1.3.6.1.4.1.3076.2.1.2.22.1.49 integer read-only
The type of power supply for Power Supply slot 1. Enumeration: 'none': 1, 'ac': 2.
         alHardwarePs2Type 1.3.6.1.4.1.3076.2.1.2.22.1.50 integer read-only
The type of power supply for Power Supply slot 2. Enumeration: 'none': 1, 'ac': 2.
         alHardwareSlot1Card 1.3.6.1.4.1.3076.2.1.2.22.1.51 concentratorcard read-only
The type of card in slot 1.
         alHardwareSlot2Card 1.3.6.1.4.1.3076.2.1.2.22.1.52 concentratorcard read-only
The type of card in slot 2.
         alHardwareSlot3Card 1.3.6.1.4.1.3076.2.1.2.22.1.53 concentratorcard read-only
The type of card in slot 3.
         alHardwareSlot4Card 1.3.6.1.4.1.3076.2.1.2.22.1.54 concentratorcard read-only
The type of card in slot 4.
         alHardwareSlot1Operational 1.3.6.1.4.1.3076.2.1.2.22.1.55 truthvalue read-only
The operational status of card in slot 1.
         alHardwareSlot2Operational 1.3.6.1.4.1.3076.2.1.2.22.1.56 truthvalue read-only
The operational status of card in slot 2.
         alHardwareSlot3Operational 1.3.6.1.4.1.3076.2.1.2.22.1.57 truthvalue read-only
The operational status of card in slot 3.
         alHardwareSlot4Operational 1.3.6.1.4.1.3076.2.1.2.22.1.58 truthvalue read-only
The operational status of card in slot 4.
         alHardwareRamSize 1.3.6.1.4.1.3076.2.1.2.22.1.59 unsigned32 read-only
The amount of memory, in MB on the concentrator.
         alHardwareChassis 1.3.6.1.4.1.3076.2.1.2.22.1.60 concentratortype read-only
The type of VPN Concentrator this is.
         alHardwareCpuVoltageNominal 1.3.6.1.4.1.3076.2.1.2.22.1.61 gauge32 read-only
The nominal CPU voltage in centivolts for the concentrator.
         alHardwareClientEthPrivSwitch 1.3.6.1.4.1.3076.2.1.2.22.1.62 truthvalue read-only
Whether or not the 3002 Hardware Client has an Ethernet Switch for the private interface.
         alHardwareSerialNumber 1.3.6.1.4.1.3076.2.1.2.22.1.63 displaystring read-only
Unit serial number.