ALPINE-GEN-CARD-EDFA-MIB: View SNMP OID List / Download MIB

VENDOR: ALPINE OPTOELECTRONICS INC


 Home MIB: ALPINE-GEN-CARD-EDFA-MIB
Download as:   

Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
 alpineGenCardEdfa 1.3.6.1.4.1.52326.1.1
     alpineGenCardEdfaInfosTable 1.3.6.1.4.1.52326.1.1.1 no-access
Description.
         alpineGenCardEdfaInfosEntry 1.3.6.1.4.1.52326.1.1.1.1 no-access
Description.
             gceSlotNum 1.3.6.1.4.1.52326.1.1.1.1.1 integer32 read-only
Slot number.
             gceEdfaNum 1.3.6.1.4.1.52326.1.1.1.1.2 integer32 read-only
EDFA Number in the line card. Up to 2 EDFA modules are supported in one line card.
             gceMode 1.3.6.1.4.1.52326.1.1.1.1.3 integer32 read-write
Work mode of EDFA. 1. AGC 2. APC Please note, when you want to change work mode, make sure the relative target value be set first. For example, if you want to set work mode to APC and the output power is 5dBm, you need set 'gceOutputPowerTarget' to 5 first.
             gceOutputPowerTarget 1.3.6.1.4.1.52326.1.1.1.1.4 octet string read-write
Output power target of EDFA. If current work mode is APC, then output power will be applied immediately. If current work mode is AGC, then output power will be applied after 'gceMode' is set to APC.
             gceGainTarget 1.3.6.1.4.1.52326.1.1.1.1.5 octet string read-write
Gain target of EDFA. If current work mode is AGC, then output power will be applied immediately. If current work mode is APC, then output power will be applied after 'gceMode' is set to AGC.
             gceOutputPower 1.3.6.1.4.1.52326.1.1.1.1.6 octet string read-only
Current output power of EDFA.
             gceGain 1.3.6.1.4.1.52326.1.1.1.1.7 octet string read-only
Current gain of EDFA.
             gceTemperature 1.3.6.1.4.1.52326.1.1.1.1.8 octet string read-only
Current temperature of EDFA.
             gceSaveConfig 1.3.6.1.4.1.52326.1.1.1.1.9 integer32 read-write
Save current configuration into flash for non-valatile setting. 0: Idle/Save Done. 1: Issue save command. 2: Saving. Only value 1 can be accepted in snmp set.
             gceInputPower 1.3.6.1.4.1.52326.1.1.1.1.10 octet string read-only
Current input power of EDFA.
     alpineGenCardEdfaAlarm 1.3.6.1.4.1.52326.1.1.2
         alpineGenCardEdfaAlarmThldTable 1.3.6.1.4.1.52326.1.1.2.1 no-access
Description.
             alpineGenCardEdfaAlarmThldEntry 1.3.6.1.4.1.52326.1.1.2.1.1 no-access
Description.
                 gceaSlotNum 1.3.6.1.4.1.52326.1.1.2.1.1.1 integer32 read-only
Slot number.
                 gceaEdfaNum 1.3.6.1.4.1.52326.1.1.2.1.1.2 integer32 read-only
EDFA Number in the line card. Up to 2 EDFA modules are supported in one line card.
                 gceaInputPowerThld 1.3.6.1.4.1.52326.1.1.2.1.1.3 octet string read-write
Low threshold of input power.
                 gceaOutputPowerThld 1.3.6.1.4.1.52326.1.1.2.1.1.4 octet string read-write
Low threshold of output power.
                 gceaTemperatureThld 1.3.6.1.4.1.52326.1.1.2.1.1.5 octet string read-write
High threshold of temperature.
         alpineGenEdfaAlarmInfoTable 1.3.6.1.4.1.52326.1.1.2.2 no-access
Description.
             alpineGenEdfaAlarmInfoEntry 1.3.6.1.4.1.52326.1.1.2.2.1 no-access
Description.
                 geaiSlotNum 1.3.6.1.4.1.52326.1.1.2.2.1.1 integer32 read-only
Description.
                 geaiEdfaNum 1.3.6.1.4.1.52326.1.1.2.2.1.2 integer32 read-only
EDFA Number in the line card. Up to 2 EDFA modules are supported in one line card.
                 geaiCommonAlarm 1.3.6.1.4.1.52326.1.1.2.2.1.3 integer32 read-only
If any alarm occurs, this field will set to 1. 0. Normal 1. One or some alarm occur.
                 geaiCaseTemperatureAlarm 1.3.6.1.4.1.52326.1.1.2.2.1.4 integer32 read-only
0. Clear 1. Case temperature alarm occurs.
                 geaiPumpTemperatureAlarm 1.3.6.1.4.1.52326.1.1.2.2.1.5 integer32 read-only
0. Clear 1. Pump temperature alarm occurs.
                 geaiPumpBiasAlarm 1.3.6.1.4.1.52326.1.1.2.2.1.6 integer32 read-only
0. Clear 1. Pump bias alarm occurs.
                 geaiLossInputAlarm 1.3.6.1.4.1.52326.1.1.2.2.1.7 integer32 read-only
0. Clear 1. Loss of input alarm occurs.
                 geaiLossOutputAlarm 1.3.6.1.4.1.52326.1.1.2.2.1.8 integer32 read-only
0. Clear 1. Loss of output alarm occurs.
         alpineGenEdfaPowerAlarm 1.3.6.1.4.1.52326.1.1.2.3
Description.
         alpineGenEdfaTemperatureAlarm 1.3.6.1.4.1.52326.1.1.2.4
Description.
         alpineGenEdfaBiasAlarm 1.3.6.1.4.1.52326.1.1.2.5
Description.
         alpineGenEdfaLossAlarm 1.3.6.1.4.1.52326.1.1.2.6
Description.