Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
 alpha 1.3.6.1.4.1.7309
This MIB defines the information block(s) available in system controllers.
           controller 1.3.6.1.4.1.7309.5
               controllerInfo 1.3.6.1.4.1.7309.5.1
                   controllerInfoName 1.3.6.1.4.1.7309.5.1.1 octet string read-only
User configurable text name of the Controller.
                   controllerInfoDescription 1.3.6.1.4.1.7309.5.1.2 octet string read-only
User configurable description of the Controller.
                   controllerInfoSoftwareVersion 1.3.6.1.4.1.7309.5.1.3 octet string read-only
Software version of the Controller application.
                   controllerInfoOperatingSystemVersion 1.3.6.1.4.1.7309.5.1.4 octet string read-only
Operating system version number.
                   controllerInfoHardwareVersion 1.3.6.1.4.1.7309.5.1.5 octet string read-only
Hardware version number.
                   controllerExtInfoTable 1.3.6.1.4.1.7309.5.1.100 no-access
Controller specific information table.
                           controllerExtInfoEntry 1.3.6.1.4.1.7309.5.1.100.1 no-access
Entries appear in this table for each possible alarm state. This table MUST be persistent across system reboots.
                               controllerExtInfoIndex 1.3.6.1.4.1.7309.5.1.100.1.1 unsigned32 no-access
Incremental integer value for each instance of the .
                               controllerExtInfoName 1.3.6.1.4.1.7309.5.1.100.1.2 octet string read-only
Name of the data value presented in the instance of the entry.
                               controllerExtInfoStringValue 1.3.6.1.4.1.7309.5.1.100.1.3 octet string read-only
String value of the data field presented by the controller info entry.
                               controllerExtInfoUnit 1.3.6.1.4.1.7309.5.1.100.1.4 octet string read-only
Unit name of the numeric value of the controller info entry.
                               controllerExtInfoNumberValue 1.3.6.1.4.1.7309.5.1.100.1.5 scalednumber read-only
Number value of the data field presented by the controller info entry.
               resource 1.3.6.1.4.1.7309.5.2
                   componentList 1.3.6.1.4.1.7309.5.2.1
                       componentListCount 1.3.6.1.4.1.7309.5.2.1.1 integer32 read-only
The number of available objects in componentList.
                       componentListTable 1.3.6.1.4.1.7309.5.2.1.2 no-access
Object componentList describes the following: Systems ( DC System, AC System, Converter System, etc. ) Devices ( ADIO, Rectifier, Converter, Inverter, etc. )
                           componentListEntry 1.3.6.1.4.1.7309.5.2.1.2.1 no-access
Entry to the component list describing the available systems and devices within the Cordex controller. Indexing: 1. Component type - please refer to componentListType 2. Snmp ID - please refer to componentListReference Configurable ID allow for component monitoring on a specific index if the method of monitoring is locked on the index value.
                               componentListReference 1.3.6.1.4.1.7309.5.2.1.2.1.1 unsigned32 no-access
Indentification number assigned to the component.
                               componentListStaticName 1.3.6.1.4.1.7309.5.2.1.2.1.2 octet string read-only
Non-configurable name permanently assigned to the component. Filtering on this data value is possible and recommended due to its static nature.
                               componentListConfiguredName 1.3.6.1.4.1.7309.5.2.1.2.1.3 octet string read-write
User configurable name of the component. Filtering on this data value is not recommended.
                               componentListType 1.3.6.1.4.1.7309.5.2.1.2.1.4 unsigned32 no-access
The type of the component based on power system terminology. 1 - Controller 2 - DC System 3 - ADIO 4 - Rectifier 5 - Converter 6 - Inverter 7 - BCMC 8 - T2S 9 - AC Input Bus 10 - Battery String 11 - Disconnect 12 - Load 13 - Shunt 14 - SNMP Destinations 15 - CAN Bus
                               componentListModelNumber 1.3.6.1.4.1.7309.5.2.1.2.1.5 octet string read-only
Component model number where applicable. This is available on component entries which describes hardware modules.
                               componentListSerialNumber 1.3.6.1.4.1.7309.5.2.1.2.1.6 octet string read-only
Serial number of the device only if the component is of physical device type.
                               componentListSystemPointer 1.3.6.1.4.1.7309.5.2.1.2.1.7 object identifier read-only
Table entry reference to the component table of the system component that the described item belongs to. Example: A rectifier component will have a reference to the Rectifier System that it belongs to.
                   dataList 1.3.6.1.4.1.7309.5.2.2
                       dataListCount 1.3.6.1.4.1.7309.5.2.2.1 integer32 read-only
The number of defined data fields available for query.
                       dataListTable 1.3.6.1.4.1.7309.5.2.2.2 no-access
Table of data fields available for query.
                           dataListEntry 1.3.6.1.4.1.7309.5.2.2.2.1 no-access
Data field entry of available fields. Indexes: 1. componentListType - indicates which component can provide the field of interest. 2. dataListReference - the ID permanently assigned to the field.
                               dataListReference 1.3.6.1.4.1.7309.5.2.2.2.1.1 unsigned32 no-access
Non-configurable ID permanently assigned to the field entry.
                               dataListName 1.3.6.1.4.1.7309.5.2.2.2.1.2 octet string read-write
Non-configurable string name of the field represented in the entry.
                               dataListType 1.3.6.1.4.1.7309.5.2.2.2.1.3 unsigned32 no-access
Canonical data type of the field entry. 0 - None 1 - Numeric 2 - Boolean 3 - Time 4 - String 5 - Choice / Selected options
                               dataListUnit 1.3.6.1.4.1.7309.5.2.2.2.1.4 octet string read-write
Unit type of the value represented by the entry.
                   data 1.3.6.1.4.1.7309.5.2.3
                       dataCount 1.3.6.1.4.1.7309.5.2.3.1 integer32 read-only
The number of defined data points available for query.
                       dataTable 1.3.6.1.4.1.7309.5.2.3.2 no-access
Table of data values associated to live data availabe from the Cordex HP controller.
                           dataEntry 1.3.6.1.4.1.7309.5.2.3.2.1 no-access
Conceptual row of data value for the referencing data field type and component that it belongs to.
                               dataReference 1.3.6.1.4.1.7309.5.2.3.2.1.1 unsigned32 no-access
Non-configurable ID permanently assigned to the field entry.
                               dataNumberValue 1.3.6.1.4.1.7309.5.2.3.2.1.2 scalednumber read-only
Numeric value of the data field.
                               dataStringValue 1.3.6.1.4.1.7309.5.2.3.2.1.3 octet string read-only
String value of the data field.
                   configurationList 1.3.6.1.4.1.7309.5.2.4
                       configurationListCount 1.3.6.1.4.1.7309.5.2.4.1 integer32 read-only
The number of defined configuration fields available for query.
                       configurationListTable 1.3.6.1.4.1.7309.5.2.4.2 no-access
Table of configuration entries.
                           configurationListEntry 1.3.6.1.4.1.7309.5.2.4.2.1 no-access
Configuration field entries available for GET and SET.
                               configurationListReference 1.3.6.1.4.1.7309.5.2.4.2.1.1 unsigned32 no-access
A numerical ID value permanently assigned to the configuration field.
                               configurationListName 1.3.6.1.4.1.7309.5.2.4.2.1.2 octet string read-only
A non-configurable string name of the configuration field.
                               configurationListType 1.3.6.1.4.1.7309.5.2.4.2.1.3 integer32 read-only
Conanical data type of the configuration field. 0 - Unknown 1 - Numeric 2 - Boolean 3 - Time 4 - String 5 - Choice / Selected Options
                               configurationListUnit 1.3.6.1.4.1.7309.5.2.4.2.1.4 octet string read-only
Unit of the numeric value of the configuration field.
                   configuration 1.3.6.1.4.1.7309.5.2.5
                       configurationCount 1.3.6.1.4.1.7309.5.2.5.1 integer32 read-only
The number of defined configuration points available for query.
                       configurationTable 1.3.6.1.4.1.7309.5.2.5.2 no-access
Table of configuration entries.
                           configurationEntry 1.3.6.1.4.1.7309.5.2.5.2.1 no-access
Configuration field entry.
                               configurationReference 1.3.6.1.4.1.7309.5.2.5.2.1.1 unsigned32 no-access
Non-configurable ID permanently assigned to the field entry.
                               configurationNumberValue 1.3.6.1.4.1.7309.5.2.5.2.1.2 scalednumber read-write
Numbered value of the configuration referenced by the Configuration Type and the Component Reference.
                               configurationStringValue 1.3.6.1.4.1.7309.5.2.5.2.1.3 octet string read-write
String value of the configuration referenced by the Configuration Type and the Component Reference.
                   commandList 1.3.6.1.4.1.7309.5.2.6
                       commandListCount 1.3.6.1.4.1.7309.5.2.6.1 integer32 read-only
The number of defined data points available for query.
                       commandListTable 1.3.6.1.4.1.7309.5.2.6.2 no-access
Table of commands available from the Cordex HP Controller.
                           commandListEntry 1.3.6.1.4.1.7309.5.2.6.2.1 no-access
Conceptual row of a command item in the Command List Table.
                               commandListReference 1.3.6.1.4.1.7309.5.2.6.2.1.1 unsigned32 no-access
Reference value to identify available commands published by the Cordex HP Controller.
                               commandListName 1.3.6.1.4.1.7309.5.2.6.2.1.2 octet string read-write
Name of the command.
                   command 1.3.6.1.4.1.7309.5.2.7
                       commandCount 1.3.6.1.4.1.7309.5.2.7.1 integer32 read-only
The number of defined command points available for query.
                       commandTable 1.3.6.1.4.1.7309.5.2.7.2 no-access
Table of command fields that are available in the Cordex HP Controller.
                           commandEntry 1.3.6.1.4.1.7309.5.2.7.2.1 no-access
Conceptual row of the Command Table.
                               commandReference 1.3.6.1.4.1.7309.5.2.7.2.1.1 unsigned32 no-access
Non-configurable ID permanently assigned to the field entry.
                               commandTrigger 1.3.6.1.4.1.7309.5.2.7.2.1.2 integer32 read-write
Command field that is the trigger to send command referenced by the Command Type and the Component that it belongs to.
                   alarmType 1.3.6.1.4.1.7309.5.2.8
                       alarmTypeCount 1.3.6.1.4.1.7309.5.2.8.1 integer32 read-only
The number of defined alarm points available for query.
                       alarmTypeTable 1.3.6.1.4.1.7309.5.2.8.2 no-access
Table of alarms available from the Cordex HP Controller.
                           alarmTypeEntry 1.3.6.1.4.1.7309.5.2.8.2.1 no-access
Conceptual row of a alarm item in the Alarm List Table.
                               alarmTypeReference 1.3.6.1.4.1.7309.5.2.8.2.1.1 unsigned32 no-access
Reference value to identify available alarms published by the Cordex HP Controller.
                               alarmTypeName 1.3.6.1.4.1.7309.5.2.8.2.1.2 octet string read-only
Name of the alarm.
                   alarm 1.3.6.1.4.1.7309.5.2.9
                       alarmCount 1.3.6.1.4.1.7309.5.2.9.1 integer32 read-only
The number of defined alarm points available for query.
                       alarmTable 1.3.6.1.4.1.7309.5.2.9.2 no-access
Table of alarm fields that are available in the Cordex HP Controller.
                           alarmEntry 1.3.6.1.4.1.7309.5.2.9.2.1 no-access
Conceptual row of the Alarm Table.
                               alarmState 1.3.6.1.4.1.7309.5.2.9.2.1.1 unsigned32 read-only
Interger representation of the state of the alarm and its priority level. 0 - Normal 1 - Warning 2 - Minor 3 - Major 4 - Critical
                   resourceConformance 1.3.6.1.4.1.7309.5.2.100
                           resourceCompliances 1.3.6.1.4.1.7309.5.2.100.1
                               resourceCompliance 1.3.6.1.4.1.7309.5.2.100.1.1
The compliance statement for systems supporting the Alpha Resource MIB.
                               resourceGroups 1.3.6.1.4.1.7309.5.2.100.1.2
                                   alphaControllerGroup 1.3.6.1.4.1.7309.5.2.100.1.2.1
Alpha controller data list group.
                                   alphaComponentGroup 1.3.6.1.4.1.7309.5.2.100.1.2.2
Component data list group.
                                   alphaDataTypeGroup 1.3.6.1.4.1.7309.5.2.100.1.2.3
Data type list group.
                                   alphaDataGroup 1.3.6.1.4.1.7309.5.2.100.1.2.4
Data type list group.
                                   alphaConfigurationTypeGroup 1.3.6.1.4.1.7309.5.2.100.1.2.5
Data type list group.
                                   alphaConfigurationGroup 1.3.6.1.4.1.7309.5.2.100.1.2.6
Data type list group.
                                   alphaCommandTypeGroup 1.3.6.1.4.1.7309.5.2.100.1.2.7
Data type list group.
                                   alphaCommandGroup 1.3.6.1.4.1.7309.5.2.100.1.2.8
Data type list group.
               simple 1.3.6.1.4.1.7309.5.3