Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
 alcatelIND1INLINEPOWERMIB 1.3.6.1.4.1.6486.801.1.2.1.27.1
This module describes an authoritative enterprise-specific Simple Network Management Protocol (SNMP) Management Information Base (MIB): Propietary InLinePower Extensions MIB definitions The right to make changes in specification and other information contained in this document without prior notice is reserved. No liability shall be assumed for any incidental, indirect, special, or consequential damages whatsoever arising from or related to this document or the information contained herein. Vendors, end-users, and other interested parties are granted non-exclusive license to use this specification in connection with management of the products for which it is intended to be used. Copyright (C) 1995-2007 Alcatel-Lucent ALL RIGHTS RESERVED WORLDWIDE
     alaPethObjects 1.3.6.1.4.1.6486.801.1.2.1.27.1.1
         alaPethPsePortTable 1.3.6.1.4.1.6486.801.1.2.1.27.1.1.1
A table of objects that augments the standard pethPsePortTable entry by adding the alaPethPsePortPowerMaximum object.
             alaPethPsePortEntry 1.3.6.1.4.1.6486.801.1.2.1.27.1.1.1.1
A set of objects that display and control the power characteristics of a power Ethernet PSE port.
                 alaPethPsePortPowerMaximum 1.3.6.1.4.1.6486.801.1.2.1.27.1.1.1.1.1
This object controls maximum amount of power per port.
                 alaPethPsePortPowerActual 1.3.6.1.4.1.6486.801.1.2.1.27.1.1.1.1.2
This object contains the actual amount of power used by a port
                 alaPethPsePortPowerStatus 1.3.6.1.4.1.6486.801.1.2.1.27.1.1.1.1.3
This object contains the power status of a port
                 alaPethPsePortPowerClass 1.3.6.1.4.1.6486.801.1.2.1.27.1.1.1.1.4
This object controls class of poe device attached on a port. class0 - The device can draw PD power from 0.44W to 12.95W and current less than 5.0 mA. class1 - The device can draw PD power from 0.44W to 3.84W and current 10.5 mA. class2 - The device can draw PD power from 3.84W to 6.49W and current 12.95 mA. class3 - The device can draw PD power from 6.49W to 12.95W and current 28 mA. class4 - This class is reserved for future use. class5 - No Powered Device is connected to this POE port, or the port is powered down.
         alaPethMainPseTable 1.3.6.1.4.1.6486.801.1.2.1.27.1.1.2
This table augments the standard table PethMainPseTable by allowing the admin status for a group to be set to on/off as well as showing the values for the max power for that group.
             alaPethMainPseEntry 1.3.6.1.4.1.6486.801.1.2.1.27.1.1.2.1
A set of objects that display and control the Main power of a PSE.
                 alaPethMainPseAdminStatus 1.3.6.1.4.1.6486.801.1.2.1.27.1.1.2.1.1
The object is used to set the status of the main PSE to ON or OFF.
                 alaPethMainPseMaxPower 1.3.6.1.4.1.6486.801.1.2.1.27.1.1.2.1.2
The maximum amount of power allowed for main PSE.
                 alaPethMainPsePriorityDisconnect 1.3.6.1.4.1.6486.801.1.2.1.27.1.1.2.1.3
The object is used to set the priority disconnect of the main PSE to Enabled or Disable.
                 alaPethMainPseCapacitorDetect 1.3.6.1.4.1.6486.801.1.2.1.27.1.1.2.1.4
The object is used to enable or disable the PowerDsine Capacitor detection method.
                 alaPethMainPsePriority 1.3.6.1.4.1.6486.801.1.2.1.27.1.1.2.1.5
The object is set the power down priority for the slot
                 alaPethMainPseComboPort 1.3.6.1.4.1.6486.801.1.2.1.27.1.1.2.1.6
The object is used to set the combo port option of the main PSE to Enable or Disable.
         alaPethNotificationObjects 1.3.6.1.4.1.6486.801.1.2.1.27.1.1.3
             pethSourceSlot 1.3.6.1.4.1.6486.801.1.2.1.27.1.1.3.1
Slot number of generating entity.
             pethSourcePort 1.3.6.1.4.1.6486.801.1.2.1.27.1.1.3.2
Port number of generating entity.
     alaPethConformance 1.3.6.1.4.1.6486.801.1.2.1.27.1.2
         alaPethCompliances 1.3.6.1.4.1.6486.801.1.2.1.27.1.2.1
             alaPethCompliance 1.3.6.1.4.1.6486.801.1.2.1.27.1.2.1.1
Describes the requirements for conformance to the Alcatel Power Ethernet MIB.
             alaPethPseCompliance 1.3.6.1.4.1.6486.801.1.2.1.27.1.2.1.2
Describes the requirements for conformance to the PSE
         alaPethGroups 1.3.6.1.4.1.6486.801.1.2.1.27.1.2.2
             alaPethPsePortGroup 1.3.6.1.4.1.6486.801.1.2.1.27.1.2.2.1
The pethPsePortGroup is mandatory for systems which implement PSE ports.
             alaPethMainPseGroup 1.3.6.1.4.1.6486.801.1.2.1.27.1.2.2.2
Main PSE Objects.
             pethTrapsGroup 1.3.6.1.4.1.6486.801.1.2.1.27.1.2.2.3
Notifications for PETH MIB
             alaPethTrapObjGroup 1.3.6.1.4.1.6486.801.1.2.1.27.1.2.2.4
Collection of Objects used by PETH Notifications.
     alaPethMain 1.3.6.1.4.1.6486.801.1.2.1.27.1.3
         alaPethMainTable 1.3.6.1.4.1.6486.801.1.2.1.27.1.3.1
A table of objects that augments the standard pethPsePortTable entry by adding the alaPethPsePortPowerMaximum object.
             alaPethMainEntry 1.3.6.1.4.1.6486.801.1.2.1.27.1.3.1.1
A set of objects that display and control the power characteristics of a power Ethernet PSE port.
                 alaPethMainIndex 1.3.6.1.4.1.6486.801.1.2.1.27.1.3.1.1.1
This variable uniquely identifies the group to which power Ethernet PSE is connected.Group means (box in the stack, module in a rack) and the value 1 MUST be used for non-modular devices
                 alaPethMainPowerRedundancy 1.3.6.1.4.1.6486.801.1.2.1.27.1.3.1.1.2
This object controls power supply redundancy.
     pethPwrSupplyConflict 1.3.6.1.4.1.6486.801.1.3.2.17.0.1
Power supply type conflict trap.
     pethPwrSupplyNotSupported 1.3.6.1.4.1.6486.801.1.3.2.17.0.2
Power supply not supported trap.