ADTRAN-TSUIQ-MIB: View SNMP OID List / Download MIB
VENDOR: ADTRAN
Home | MIB: ADTRAN-TSUIQ-MIB | |||
---|---|---|---|---|
Download as: |
Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
|
|||
Object Name | OID | Type | Access | Info |
adTSUIQ | 1.3.6.1.4.1.664.1.147 | |||
adTSUIQNetworkPhysUp | 1.3.6.1.4.1.664.1.1470.14701 |
This trap indicates that the physical layer of the network is now up. |
||
adTSUIQNetworkPhysDown | 1.3.6.1.4.1.664.1.1470.14702 |
This trap indicates that the physical layer of the network is now down. |
||
adTSUIQNetworkLMIUp | 1.3.6.1.4.1.664.1.1470.14703 |
This trap indicates that the LMI state of the network is now up. |
||
adTSUIQNetworkLMIDown | 1.3.6.1.4.1.664.1.1470.14704 |
This trap indicates that the LMI state of the network is now down. |
||
adTSUIQColdStart | 1.3.6.1.4.1.664.1.1470.14705 |
This trap indicates that a cold start has occurred. |
||
adTSUIQmg | 1.3.6.1.4.1.664.2.147 | |||
adTSUIQSystemConfig | 1.3.6.1.4.1.664.2.147.1 | |||
adTSUIQPassword | 1.3.6.1.4.1.664.2.147.1.1 | displaystring | read-write |
Sets the Telnet and Vt100 Control Password. |
adTSUIQTOD | 1.3.6.1.4.1.664.2.147.1.2 | displaystring | read-write |
Sets the Time of Day with format hh:mm. |
adTSUIQDate | 1.3.6.1.4.1.664.2.147.1.3 | displaystring | read-write |
Sets the Date with the format MM-DD-YY. |
adTSUIQIpAddress | 1.3.6.1.4.1.664.2.147.1.4 | ipaddress | read-write |
Sets the unit's IP Address. |
adTSUIQIpAddressMask | 1.3.6.1.4.1.664.2.147.1.5 | ipaddress | read-write |
Sets the Network Subnet Mask. |
adTSUIQGatewayIpAddress | 1.3.6.1.4.1.664.2.147.1.6 | ipaddress | read-write |
Sets the Network Gateway IP Address. |
adTSUIQTrapManagerIpAddress | 1.3.6.1.4.1.664.2.147.1.7 | ipaddress | read-write |
Sets the Trap Manager IP Address. |
adTSUIQTrapManagerDLCI | 1.3.6.1.4.1.664.2.147.1.8 | integer | read-write |
Sets the Trap Manager DLCI. (Range 16 - 1007). |
adTSUIQTrapManagerPort | 1.3.6.1.4.1.664.2.147.1.9 | integer | read-write |
Selects the Trap Manager Port. Enumeration: 'networkPort': 3, 'controlPort': 4, 'none': 1, 'ethernetPort': 5, 'dtePort': 2. |
adTSUIQControPortBaud | 1.3.6.1.4.1.664.2.147.1.10 | integer | read-write |
Selects the Control Port Baud Rate. Enumeration: 'bps19200': 2, 'bps38400': 3, 'bps9600': 1. |
adTSUIQControPortMode | 1.3.6.1.4.1.664.2.147.1.11 | integer | read-write |
Selects the Control Port Mode. Enumeration: 'terminal': 1, 'ppp': 3, 'slip': 2. |
adTSUIQEnableTraps | 1.3.6.1.4.1.664.2.147.1.12 | integer | read-write |
Overall trap enable/disable. Enumeration: 'disabled': 1, 'enabled': 2. |
adTSUIQAlarmState | 1.3.6.1.4.1.664.2.147.1.13 | integer | read-only |
This bit map variable indicates alarm conditions which are currently set. When an alarm condition occurs, the corresponding event bit is set in this variable. If armed, setting the event will generate an Alarm Trap. The various alarm event bit positions are: 1 = Network physical link up. 2 = Network physical link down. 4 = Network signal state up. 8 = Network signal state down. |
adTSUIQArmAlarm | 1.3.6.1.4.1.664.2.147.1.14 | integer | read-write |
This bit map variable arms or disarms an individual or group of events identified in adFradAlarmState as a source for generation of an Alarm Trap. The various arm event bit positions are : 1 = Network physical link up. 2 = Network physical link down. 4 = Network signal state up. 8 = Network signal state down. |
adTSUIQAbortConfig | 1.3.6.1.4.1.664.2.147.1.15 | integer | read-write |
A Set will cancel current selections and reverts to the last saved configuration. Enumeration: 'abortConfig': 1. |
adTSUIQSaveConfig | 1.3.6.1.4.1.664.2.147.1.16 | integer | read-write |
A Set will reset the unit and Save the current selections. Enumeration: 'saveConfig': 1. |
adTSUIQNetPortConfig | 1.3.6.1.4.1.664.2.147.2 | |||
adTSUIQNetPortFrameType | 1.3.6.1.4.1.664.2.147.2.1 | integer | read-write |
Frame type for T1 interface Enumeration: 'eSF': 2, 'd4': 1, 'auto': 3. |
adTSUIQNetPortClockSource | 1.3.6.1.4.1.664.2.147.2.2 | integer | read-write |
Timing source for the transmit side of the T1 interface. Enumeration: 'fromNetwork': 2, 'internal': 1. |
adTSUIQNetPortLineCode | 1.3.6.1.4.1.664.2.147.2.3 | integer | read-write |
Line code for the the T1 interface. Enumeration: 'aMI': 2, 'b8ZS': 1. |
adTSUIQNetRxSensitivity | 1.3.6.1.4.1.664.2.147.2.4 | integer | read-write |
Selects the gain of receiver for the T1 interface. Enumeration: 'extended': 2, 'normal': 1. |
adTSUIQNetPortLBO | 1.3.6.1.4.1.664.2.147.2.5 | integer | read-write |
Line build out for the transmit side of the T1 interface. Enumeration: 'dB15': 4, 'auto': 1, 'db22': 5, 'dB7': 3, 'dB0': 2. |
adTSUIQNetChannelCount | 1.3.6.1.4.1.664.2.147.2.6 | integer | read-write |
Selects the number of active channels for the T1 interface. |
adTSUIQNetChannelStart | 1.3.6.1.4.1.664.2.147.2.7 | integer | read-write |
Selects the channel that begins the active channel list for the T1 interface. |
adTSUIQNetChannelBandwidth | 1.3.6.1.4.1.664.2.147.2.8 | integer | read-write |
Selects the amount of data in each active channel for the T1 interface. Enumeration: 'x64Kbps': 2, 'x56Kbps': 1. |
adTSUIQNetChannelAlignment | 1.3.6.1.4.1.664.2.147.2.9 | integer | read-write |
Selects the alignment of active channels for the T1 interface. Enumeration: 'alternating': 2, 'contiguous': 1. |
adTSUIQNetTransmitPRM | 1.3.6.1.4.1.664.2.147.2.10 | integer | read-write |
Enables performance report generation across the T1 FDL for the T1 interface. Enumeration: 'pRMon': 1, 'pRMoff': 2. |
adTSUIQNetPortSignaling | 1.3.6.1.4.1.664.2.147.2.11 | integer | read-write |
Signaling type for the frame relay management interface. Enumeration: 'conLMI': 2, 'auto': 5, 'none': 1, 'ansiT1617D': 3, 'ituQ933A': 4. |
adTSUIQNetPortt391 | 1.3.6.1.4.1.664.2.147.2.12 | integer | read-write |
Sets the polling interval in seconds for the frame relay management interface. (Range 5 - 30). |
adTSUIQNetPortn391 | 1.3.6.1.4.1.664.2.147.2.13 | integer | read-write |
Sets the interval between full status polls for the frame relay management interface. (Range 1 - 255). |
adTSUIQNetPortn392 | 1.3.6.1.4.1.664.2.147.2.14 | integer | read-write |
Sets the error count for the frame relay management interface. (Range 1 - 10). |
adTSUIQNetPortn393 | 1.3.6.1.4.1.664.2.147.2.15 | integer | read-write |
Sets the event window for the frame relay management interface. ( Range 1 - 10). |
adTSUIQNetPortMgmtDlci1Mode | 1.3.6.1.4.1.664.2.147.2.16 | integer | read-write |
Sets the mode for the managent DLCI 1. If set for shared, management DLCI 1 is used for customer data and IQ management data. If set for dedicated, management DLCI 1 is used only for IQ management data and is not passed to the attached frame relay DTE device. Enumeration: 'shared': 1, 'dedicated': 2. |
adTSUIQNetPortMgmtDlci2Mode | 1.3.6.1.4.1.664.2.147.2.17 | integer | read-write |
Sets the mode for the managent DLCI 2. If set for shared, management DLCI 2 is used for customer data and IQ management data. If set for dedicated, management DLCI 2 is used only for IQ management data and is not passed to the attached frame relay DTE device. Enumeration: 'shared': 1, 'dedicated': 2. |
adTSUIQNetMgmtDlci1 | 1.3.6.1.4.1.664.2.147.2.18 | integer | read-write |
Sets the address for management PVC 1. (Range 16 - 1007). |
adTSUIQNetMgmtDlci2 | 1.3.6.1.4.1.664.2.147.2.19 | integer | read-write |
Sets the address for management PVC 2. (Range 16 - 1007). |
adTSUIQNetPortMaxPVCs | 1.3.6.1.4.1.664.2.147.2.20 | integer | read-write |
Sets the maxium PVCs supported by the IQ unit. (Range 1 - 100). |
adTSUIQNetPortHistIntervals | 1.3.6.1.4.1.664.2.147.2.21 | integer | read-write |
Sets the number of history intervals for storage. |
adTSUIQNetPortHistIntervalsAvailable | 1.3.6.1.4.1.664.2.147.2.22 | integer | read-only |
Returns the number of history intervals allowed based on the maxium number of PVCs selected. |
adTSUIQDtePortConfig | 1.3.6.1.4.1.664.2.147.3 | |||
adTSUIQDteCTSOption | 1.3.6.1.4.1.664.2.147.3.1 | integer | read-write |
Selects the Clear to Send (CTS) option. Enumeration: 'forcedOn': 1, 'followRTS': 2. |
adTSUIQDteCDOption | 1.3.6.1.4.1.664.2.147.3.2 | integer | read-write |
Selects the Carrier Detect (CD) option. Enumeration: 'forcedOn': 1, 'normal': 2. |
adTSUIQDteDSROption | 1.3.6.1.4.1.664.2.147.3.3 | integer | read-write |
Selects the Data Set Ready (DSR) option. Enumeration: 'forcedOn': 1, 'normal': 2. |
adTSUIQDtePortMgmtDLCI | 1.3.6.1.4.1.664.2.147.3.4 | integer | read-write |
Selects the DTE Port Management DLCI. (Range 16 - 1007). |
adTSUIQDtePortt392 | 1.3.6.1.4.1.664.2.147.3.5 | integer | read-write |
Sets the timeout in seconds between polling intervals. (Range 5 - 30).. |
adTSUIQDtePortn392 | 1.3.6.1.4.1.664.2.147.3.6 | integer | read-write |
Sets the number of error events for the frame relay management. (Range 1 - 10).. |
adTSUIQDtePortn393 | 1.3.6.1.4.1.664.2.147.3.7 | integer | read-write |
Sets the error window (polling events) for the frame relay management. (Range 1 - 10). |
adTSUIQDteTCClockOption | 1.3.6.1.4.1.664.2.147.3.8 | integer | read-write |
Sets the phase of the DTE Transmit clock. Enumeration: 'inverted': 2, 'normal': 1. |
adTSUIQDteManagementPvcOption | 1.3.6.1.4.1.664.2.147.3.9 | integer | read-write |
Controls the presence of the DTE management PVC in a full status response to the DTE device. Enumeration: 'disabled': 2, 'enabled': 1. |
adTSUIQDteSignalingResponsesOption | 1.3.6.1.4.1.664.2.147.3.10 | integer | read-write |
Determines how the IQ device will respond to polls from the DTE device during a network failure. If set to always on, the IQ will respond to polls during a network failure. If set to follow network, the IQ will not respond thus emulating a failure to the DTE device. If the IQ is responsible for dial backup, this option should be set to always on. Enumeration: 'alwaysOn': 1, 'followsNetwork': 2. |
adTSUIQDteFlowControlOption | 1.3.6.1.4.1.664.2.147.3.11 | integer | read-write |
Determines how the IQ device will respond to congestion during DBU operation. If set for none, the IQ will drop frames during DBU operation when severe congestion occurs. If set for hardware, the IQ will vary the DTE TC clock in order to control the amount of data offered to the IQ when severe congestion occurs. FECN/BECN mode will set the FECN bit in outbound frames and set BECN bit for inbound frames leaving flow control up to the DTE devices. Enumeration: 'hardware': 2, 'none': 1, 'fECNBECN': 3. |
adTSUIQPvcConfig | 1.3.6.1.4.1.664.2.147.4 | |||
adTSUIQPvcConfigTable | 1.3.6.1.4.1.664.2.147.4.1 | no-access |
n/a. |
|
1.3.6.1.4.1.664.2.147.4.1.1 | no-access |
n/a |
||
adTSUIQPvcConfigIndex | 1.3.6.1.4.1.664.2.147.4.1.1.1 | integer | read-only |
n/a. |
adTSUIQPvcDLCI | 1.3.6.1.4.1.664.2.147.4.1.1.2 | integer | read-write |
Address for this PVC entry. (Range 16 - 1007). |
adTSUIQPvcCIR | 1.3.6.1.4.1.664.2.147.4.1.1.3 | integer | read-write |
Commited Information Rate for this PVC in Kbps. (Range 0 - 1536). |
adTSUIQPvcSequenceOption | 1.3.6.1.4.1.664.2.147.4.1.1.4 | integer | read-write |
Sequence number allows the IQ to detect lost frames across the frame relay service. This option should be disabled for PVCs that do not have IQ on both ends. Enumeration: 'disabled': 1, 'enabled': 2. |
adTSUIQPvcDelayPacketOption | 1.3.6.1.4.1.664.2.147.4.1.1.5 | integer | read-write |
Delay packet option for this PVC allows the IQ to sample round trip delay across the frame relay service. This option should be disabled for PVCs that do not have IQ on both ends. Enumeration: 'disabled': 1, 'enabled': 2. |
adTSUIQPvcDBUDLCI | 1.3.6.1.4.1.664.2.147.4.1.1.6 | integer | read-write |
Used when this PVC entry is used for dial backup. This value should contain the PVC address as seen on the far end of the PVC. |
adTSUIQPvcStatsControl | 1.3.6.1.4.1.664.2.147.4.1.1.7 | integer | read-write |
Stats Control option determines how the IQ will track statistics for this PVC entry. Auto will allow the IQ to track statistics for a PVC if enough memory is available. Enumeration: 'disabled': 3, 'auto': 1, 'enabled': 2. |
adTSUIQCurrentStatus | 1.3.6.1.4.1.664.2.147.5 | |||
adTSUIQT1State | 1.3.6.1.4.1.664.2.147.5.1 | integer | read-only |
Current status of the T1 interface Enumeration: 'testFromTelco': 2, 'openLoop': 1, 'yellowAlarm': 5, 'd4Normal': 7, 'blueAlarm': 3, 'redAlarm': 4, 'eSFNormal': 6. |
adTSUIQDteControlLeads | 1.3.6.1.4.1.664.2.147.5.2 | integer | read-only |
This bit map integer reflects the current state of the DTE control leads as follows: bit meaning 0 CTS 1 RTS 2 DSR 3 DTR 4 DCD A 1 means the lead is on. |
adTSUIQDBUPortType | 1.3.6.1.4.1.664.2.147.5.3 | integer | read-only |
Returns the DBU card type installed. Enumeration: 'v34modem': 2, 'dce': 3, 'sw564wire': 4, 'empty': 1, 'sw562wire': 5, 'isdn': 6. |
adTSUIQLANPortStatus | 1.3.6.1.4.1.664.2.147.5.4 | integer | read-only |
Returns the LAN card type installed. Enumeration: 'ethernet': 2, 'empty': 1. |
adTSUIQLEDstatus | 1.3.6.1.4.1.664.2.147.5.5 | integer | read-only |
This bit map integer reflects TSUIQ front panel LED state as follows: bit meaning 0 TEST 1 ALARM 2 ERROR 3 RD 4 TD 5 CTS 6 RTS |
adTSUIQDTESignalingState | 1.3.6.1.4.1.664.2.147.5.6 | integer | read-only |
Current state of the PVC signaling between the TSUIQ and the attached frame relay dte. Enumeration: 'down': 2, 'up': 1. |
adTSUIQNETSignalingState | 1.3.6.1.4.1.664.2.147.5.7 | integer | read-only |
Current state of the PVC signaling between the TSUIQ and the frame relay service. Enumeration: 'down': 2, 'up': 1. |
adTSUIQNETPVCCount | 1.3.6.1.4.1.664.2.147.5.8 | integer | read-only |
Current count of network pvcs. |
adTSUIQNETPVCConfigTableSize | 1.3.6.1.4.1.664.2.147.5.9 | integer | read-only |
Current count of rows in the PVC config table. |
adTSUIQDBUState | 1.3.6.1.4.1.664.2.147.5.10 | integer | read-only |
Current state of the DBU interface. Enumeration: 'connect4d8R': 37, 'ringing': 12, 'sPIDOK': 5, 'inDBU': 7, 'waitingPasscode': 50, 'connect33d6': 25, 'connect4d8': 47, 'tEIOK': 4, 'dialingNumber4': 17, 'connect57d6R': 33, 'connect115d2R': 27, 'busy': 22, 'connect2d4': 48, 'noRXSignal': 11, 'connect19d2R': 35, 'noAnswer': 21, 'noDialTone': 20, 'dialingNumber5': 18, 'anserwingCall': 19, 'connect115d2': 28, 'dialingNumber1': 14, 'dialingNumber3': 16, 'dialingNumber2': 15, 'waitingToDial': 23, 'connect38d4R': 34, 'connect38d4': 44, 'invalidPasscode': 51, 'connect21d6': 32, 'gettingTEI': 3, 'connect7d2': 42, 'connect12d0': 41, 'noSealingCurrent': 9, 'validPasscode': 52, 'waitingForCall': 8, 'connect14d4': 40, 'connect19d2': 45, 'connect28d8': 29, 'dialing': 13, 'connect9d6R': 36, 'connect24d0': 31, 'outOfService': 10, 'connect26d4': 30, 'connect31d2': 26, 'connect57d6': 43, 'openLoop': 2, 'connect9d6': 46, 'emptySlot': 1, 'sendingPasscode': 49, 'idle': 6, 'error': 53, 'connect16d8': 39, 'connect2d4R': 38, 'connect': 24. |
adTSUIQIntT1Status | 1.3.6.1.4.1.664.2.147.6 | |||
adTSUIQIntT1StatusTable | 1.3.6.1.4.1.664.2.147.6.1 | no-access |
n/a. |
|
1.3.6.1.4.1.664.2.147.6.1.1 | no-access |
n/a |
||
adTSUIQIntT1SlotIndex | 1.3.6.1.4.1.664.2.147.6.1.1.1 | integer | read-only |
n/a. |
adTSUIQIntT1UnavailableTime | 1.3.6.1.4.1.664.2.147.6.1.1.2 | counter | read-only |
Amount of time in seconds the T1 port is unavailable due to test or in an inactive state. |
adTSUIQIntT1StateChange | 1.3.6.1.4.1.664.2.147.6.1.1.3 | counter | read-only |
Number of changes in the T1 port state. This includes all normal, inactive, and test state transitions. |
adTSUIQIntT1SignalLossEvent | 1.3.6.1.4.1.664.2.147.6.1.1.4 | integer | read-only |
Active state represents one or more signal loss events. Enumeration: 'active': 1, 'inactive': 2. |
adTSUIQIntT1LoopBackEvent | 1.3.6.1.4.1.664.2.147.6.1.1.5 | integer | read-only |
Active state represents one or more loopback events. Enumeration: 'active': 1, 'inactive': 2. |
adTSUIQIntT1AISEvent | 1.3.6.1.4.1.664.2.147.6.1.1.6 | integer | read-only |
Active state represents one or more AIS events. AIS is triggered by unframed all ones condition from the T1 service provider. Enumeration: 'active': 1, 'inactive': 2. |
adTSUIQIntT1RedAlarmEvent | 1.3.6.1.4.1.664.2.147.6.1.1.7 | integer | read-only |
Active state represents one or more red alarm events. Red alarm is triggered by loss of frame alignment on the receive T1 signal. Enumeration: 'active': 1, 'inactive': 2. |
adTSUIQIntT1YellowAlarmEvent | 1.3.6.1.4.1.664.2.147.6.1.1.8 | integer | read-only |
Active state represents one or more yellow alarm events. Yellow alarm is an indication the service provider has lost frame alignmnet. Enumeration: 'active': 1, 'inactive': 2. |
adTSUIQIntT1PLLAlarmEvent | 1.3.6.1.4.1.664.2.147.6.1.1.9 | integer | read-only |
Active state represents one or more PLL alarm events. PLL alarm is an indication that the transmit and receive side of the T1 interface are not looped timed. This will occur when both ends of the T1 are set to provide timing. Enumeration: 'active': 1, 'inactive': 2. |
adTSUIQIntT1PathCodeViolation | 1.3.6.1.4.1.664.2.147.6.1.1.10 | counter | read-only |
Count of path code violations received. Path code violations are a errors in the frame bit postions for D4 and ESF CRC errors when set for ESF. |
adTSUIQIntT1LineCodeViolation | 1.3.6.1.4.1.664.2.147.6.1.1.11 | counter | read-only |
Count of line code violations received. Line code violations are a combination of BPVs that are not part of B8ZS code and excess zeros. Excess zeros are 8 or more consecutive zeros when set for B8ZS and 15 or more consecutive zeros when set for AMI. |
adTSUIQDayT1Status | 1.3.6.1.4.1.664.2.147.7 | |||
adTSUIQDayT1StatusTable | 1.3.6.1.4.1.664.2.147.7.1 | no-access |
n/a. |
|
1.3.6.1.4.1.664.2.147.7.1.1 | no-access |
n/a |
||
adTSUIQDayT1SlotIndex | 1.3.6.1.4.1.664.2.147.7.1.1.1 | integer | read-only |
n/a. |
adTSUIQDayT1UnavailableTime | 1.3.6.1.4.1.664.2.147.7.1.1.2 | counter | read-only |
Amount of time in seconds the T1 port is unavailable due to test or in an inactive state. |
adTSUIQDayT1StateChange | 1.3.6.1.4.1.664.2.147.7.1.1.3 | counter | read-only |
Number of changes in the T1 port state. This includes all normal, inactive, and test state transitions. |
adTSUIQDayT1SignalLossEvent | 1.3.6.1.4.1.664.2.147.7.1.1.4 | integer | read-only |
Active state represents one or more signal loss events. Enumeration: 'active': 1, 'inactive': 2. |
adTSUIQDayT1LoopBackEvent | 1.3.6.1.4.1.664.2.147.7.1.1.5 | integer | read-only |
Active state represents one or more loopback events. Enumeration: 'active': 1, 'inactive': 2. |
adTSUIQDayT1AISEvent | 1.3.6.1.4.1.664.2.147.7.1.1.6 | integer | read-only |
Active state represents one or more AIS events. AIS is triggered by unframed all ones condition from the T1 service provider. Enumeration: 'active': 1, 'inactive': 2. |
adTSUIQDayT1RedAlarmEvent | 1.3.6.1.4.1.664.2.147.7.1.1.7 | integer | read-only |
Active state represents one or more red alarm events. Red alarm is triggered by loss of frame alignment on the receive T1 signal. Enumeration: 'active': 1, 'inactive': 2. |
adTSUIQDayT1YellowAlarmEvent | 1.3.6.1.4.1.664.2.147.7.1.1.8 | integer | read-only |
Active state represents one or more yellow alarm events. Yellow alarm is an indication the service provider has lost frame alignmnet. Enumeration: 'active': 1, 'inactive': 2. |
adTSUIQDayT1PLLAlarmEvent | 1.3.6.1.4.1.664.2.147.7.1.1.9 | integer | read-only |
Active state represents one or more PLL alarm events. PLL alarm is an indication that the transmit and receive side of the T1 interface are not looped timed. This will occur when both ends of the T1 are set to provide timing. Enumeration: 'active': 1, 'inactive': 2. |
adTSUIQDayT1PathCodeViolation | 1.3.6.1.4.1.664.2.147.7.1.1.10 | counter | read-only |
Count of path code violations received. Path code violations are a errors in the frame bit postions for D4 and ESF CRC errors when set for ESF. |
adTSUIQDayT1LineCodeViolation | 1.3.6.1.4.1.664.2.147.7.1.1.11 | counter | read-only |
Count of line code violations received. Line code violations are a combination of BPVs that are not part of B8ZS code and excess zeros. Excess zeros are 8 or more consecutive zeros when set for B8ZS and 15 or more consecutive zeros when set for AMI. |
adTSUIQDiagnostic | 1.3.6.1.4.1.664.2.147.8 | |||
adTSUIQDiagnosticTable | 1.3.6.1.4.1.664.2.147.8.1 | no-access |
n/a. |
|
1.3.6.1.4.1.664.2.147.8.1.1 | no-access |
n/a |
||
adTSUIQDiagnosticIndex | 1.3.6.1.4.1.664.2.147.8.1.1.1 | integer | read-only |
n/a. |
adTSUIQDiagnosticDlci | 1.3.6.1.4.1.664.2.147.8.1.1.2 | integer | read-only |
Sets the DLCI for PVC Loopback. (Range 16 - 1007). |
adTSUIQDiagnosticControl | 1.3.6.1.4.1.664.2.147.8.1.1.3 | integer | read-write |
Starts or Stops the PVC Loopback Test. Enumeration: 'control': 1. |
adTSUIQDiagnosticDuration | 1.3.6.1.4.1.664.2.147.8.1.1.4 | integer | read-write |
Test duration in seconds. |
adTSUIQDiagnosticStatus | 1.3.6.1.4.1.664.2.147.8.1.1.5 | integer | read-write |
PVC Loopback Test Status. (Active/Inactive). Enumeration: 'diagnosticOff': 1, 'diagnosticOn': 2. |
adTSUIQDiagnosticSecondsRemaining | 1.3.6.1.4.1.664.2.147.8.1.1.6 | integer | read-only |
PVC Loopback Test time remaining in seconds. |
adTSUIQDiagnosticFramesTx | 1.3.6.1.4.1.664.2.147.8.1.1.7 | counter | read-only |
Diagnostic Frames transmitted. |
adTSUIQDiagnosticFramesRx | 1.3.6.1.4.1.664.2.147.8.1.1.8 | counter | read-only |
Diagnostic Frames received. |
adTSUIQDiagnosticLostFrames | 1.3.6.1.4.1.664.2.147.8.1.1.9 | counter | read-only |
Diagnostic Frames Lost. |
adTSUIQDiagnosticMaxDelay | 1.3.6.1.4.1.664.2.147.8.1.1.10 | gauge | read-only |
Diagnostic Maximum Delay measurement. |
adTSUIQDiagnosticMinDelay | 1.3.6.1.4.1.664.2.147.8.1.1.11 | gauge | read-only |
Diagnostic Minimum Delay measurement. |
adTSUIQDiagnosticAvgDelay | 1.3.6.1.4.1.664.2.147.8.1.1.12 | gauge | read-only |
Diagnostic Average Delay measurement. |
adTSUIQ1406Time | 1.3.6.1.4.1.664.2.147.9 | |||
adTSUIQ1406TimeTable | 1.3.6.1.4.1.664.2.147.9.1 | no-access |
n/a. |
|
1.3.6.1.4.1.664.2.147.9.1.1 | no-access |
n/a |
||
adTSUIQ1406TimeSlotIndex | 1.3.6.1.4.1.664.2.147.9.1.1.1 | integer | read-only |
n/a. |
adTSUIQ1406TimeStamp | 1.3.6.1.4.1.664.2.147.9.1.1.2 | displaystring | read-only |
Time interval started. Format H:M if not midnight else M-D |
adTSUIQDBUConfig | 1.3.6.1.4.1.664.2.147.10 | |||
adTSUIQDBUOption | 1.3.6.1.4.1.664.2.147.10.1 | integer | read-write |
This option specifies whether the unit automatically enters dial backup mode or waits for manual setup. Enumeration: 'enable': 2, 'disable': 1. |
adTSUIQDBUStartLockout | 1.3.6.1.4.1.664.2.147.10.2 | integer | read-write |
This option selects the hour to begin disabling dial backup operation when daily or weekend lockout mode is active. |
adTSUIQDBUEndLockout | 1.3.6.1.4.1.664.2.147.10.3 | integer | read-write |
This option selects the hour to end dial backup lockout when daily or weekend lockout mode is active. |
adTSUIQDBUMode | 1.3.6.1.4.1.664.2.147.10.4 | integer | read-write |
This option specifies the dial backup operating mode for the unit as orginate or answer. One end must be set to originate and the other end to answer. Enumeration: 'answer': 1, 'originate': 2. |
adTSUIQDBUWithNetworkFailure | 1.3.6.1.4.1.664.2.147.10.5 | integer | read-write |
This option enables the unit to enter backup mode when T1 network failure occurs. Enumeration: 'enable': 2, 'disable': 1. |
adTSUIQDBUNoLMI | 1.3.6.1.4.1.664.2.147.10.6 | integer | read-write |
This option enables the unit to enter backup mode when network PVC signaling state goes down. Enumeration: 'enable': 2, 'disable': 1. |
adTSUIQAutoRestoreTimer | 1.3.6.1.4.1.664.2.147.10.7 | integer | read-write |
This option selects the amount of time that the TSUIQ circuit must be active before the unit switches from backup to normal mode of operation. The timer value is in minutes from 0 to 60. A zero value disables automatic restore, TSUIQ operation must be restored manually. |
adTSUIQRedialCount | 1.3.6.1.4.1.664.2.147.10.8 | integer | read-write |
This option allows the selection of the number of times the unit will redial the Far End unit when attempting to go to backup and a busy or reorder condition occurs. Redial count can be set for a maximum of 60. |
adTSUIQDBUFailTimeout | 1.3.6.1.4.1.664.2.147.10.9 | integer | read-write |
This option allows the selection of the amount of time that the dedicated circuit failure condition is active before attempting to enter dial backup mode. The Fail Timeout value is in increments of 10 seconds up to a maximum of 600 seconds. |
adTSUIQDBURedialTimer | 1.3.6.1.4.1.664.2.147.10.10 | integer | read-write |
This option works in conjunction with the Redial Counter option. The Redial Timer specifies the amount of time between redial attempts. The Redial Timer value is seconds, up to a maximum of 60 seconds. |
adTSUIQDBUPassCheck | 1.3.6.1.4.1.664.2.147.10.11 | integer | read-write |
This option allows the unit to send and verify a dial backup passcode for an additional level of security. When enabled, the originate unit sends the passcode and the answer unit checks the passcode before the backup connection is considered valid. Enumeration: 'enable': 2, 'disable': 1. |
adTSUIQDBUPassCode | 1.3.6.1.4.1.664.2.147.10.12 | displaystring | read-write |
This option sets the dial backup passcode used to provide an additional level of security. A passcode of one to ten digit characters can be set. If enabled, the originate unit sends the passcode and the answer unit checks the passcode to verify the connection. |
adTSUIQWeekendLockout | 1.3.6.1.4.1.664.2.147.10.13 | integer | read-write |
This option enables or disables Weekend Lockout for Dial Backup operation. If enabled, no backup will occur from midnight Friday to midnight Sunday. Enumeration: 'enable': 2, 'disable': 1. |
adTSUIQDailyLockout | 1.3.6.1.4.1.664.2.147.10.14 | integer | read-write |
This option enables or disables Daily Lockout for Dial Backup operation. If enabled, no backup will occur between Lockout Start hour and Lockout End hour. Enumeration: 'enable': 2, 'disable': 1. |
adTSUIQAnswerAlways | 1.3.6.1.4.1.664.2.147.10.15 | integer | read-write |
This option enables or disables Answer Always for Dial Backup operation. If enabled, the answer unit answers any incoming call regardless of failed conditions. Enumeration: 'enable': 2, 'disable': 1. |
adTSUIQBeeperOption | 1.3.6.1.4.1.664.2.147.10.16 | integer | read-write |
This option enables or disables the audible alarm when the IQ unit goes into dial backup mode. Enumeration: 'enable': 2, 'disable': 1. |
adTSUIQDBUPhoneNumber1 | 1.3.6.1.4.1.664.2.147.10.17 | displaystring | read-write |
This option is used to set a phone number to place a DBU call. |
adTSUIQDBUPhoneNumber2 | 1.3.6.1.4.1.664.2.147.10.18 | displaystring | read-write |
This option is used to set a phone number to place a DBU call. |
adTSUIQDBUPhoneNumber3 | 1.3.6.1.4.1.664.2.147.10.19 | displaystring | read-write |
This option is used to set a phone number to place a DBU call. |
adTSUIQDBUPhoneNumber4 | 1.3.6.1.4.1.664.2.147.10.20 | displaystring | read-write |
This option is used to set a phone number to place a DBU call. |
adTSUIQDBUPhoneNumber5 | 1.3.6.1.4.1.664.2.147.10.21 | displaystring | read-write |
This option is used to set a phone number to place a DBU call. |
adTSUIQDBUISDNSwitch | 1.3.6.1.4.1.664.2.147.10.22 | integer | read-write |
This option is used to select the ISDN switch type. Enumeration: 'nt-dms-100': 2, 'att-5ess': 1, 'national-isdn1': 3. |
adTSUIQDBUISDNBChannelRate | 1.3.6.1.4.1.664.2.147.10.23 | integer | read-write |
This option is used to select the ISDN channel rate. Enumeration: 'bps64000': 2, 'bps56000': 1. |
adTSUIQDBUISDNBChannelCount | 1.3.6.1.4.1.664.2.147.10.24 | integer | read-write |
This option is used to select the number ISDN channels to use. |
adTSUIQDBUISDNSPID1 | 1.3.6.1.4.1.664.2.147.10.25 | displaystring | read-write |
This option is used to set the SPID for the ISDN interface. |
adTSUIQDBUISDNSPID2 | 1.3.6.1.4.1.664.2.147.10.26 | displaystring | read-write |
This option is used to set the SPID for the ISDN interface. |
adTSUIQDBUISDNLDN1 | 1.3.6.1.4.1.664.2.147.10.27 | displaystring | read-write |
This option is used to set LDN for the ISDN interface. |
adTSUIQDBUISDNLDN2 | 1.3.6.1.4.1.664.2.147.10.28 | displaystring | read-write |
This option is used to set LDN for the ISDN interface. |
adTSUIQV34LineType | 1.3.6.1.4.1.664.2.147.10.29 | integer | read-write |
This option selects the type of analog phone line. Enumeration: 'tone': 1, 'pulse': 2. |
adTSUIQDCEInterfaceType | 1.3.6.1.4.1.664.2.147.10.30 | integer | read-write |
This option enables or disables Answer Always for Dial Backup operation. If enabled, the answer unit answers any incoming call regardless of failed conditions. Enumeration: 'rs232': 1, 'v35': 2. |
adTSUIQDCEBitRate | 1.3.6.1.4.1.664.2.147.10.31 | integer | read-write |
This option is uses for utilization measurement of the DBU port when an external DCE device is used. Set this parameter in KBPS close to the connection rate. |
adTSUIQIntDBUStatus | 1.3.6.1.4.1.664.2.147.11 | |||
adTSUIQIntDBUStatusTable | 1.3.6.1.4.1.664.2.147.11.1 | no-access |
n/a. |
|
1.3.6.1.4.1.664.2.147.11.1.1 | no-access |
n/a |
||
adTSUIQIntDBUSlotIndex | 1.3.6.1.4.1.664.2.147.11.1.1.1 | integer | read-only |
n/a. |
adTSUIQIntDBUFramesRx | 1.3.6.1.4.1.664.2.147.11.1.1.2 | counter | read-only |
The number of Frames the Port received for the interval. |
adTSUIQIntDBUFramesTx | 1.3.6.1.4.1.664.2.147.11.1.1.3 | counter | read-only |
The number of Frames the Port transmitted for the interval. |
adTSUIQIntDBUBytesRx | 1.3.6.1.4.1.664.2.147.11.1.1.4 | counter | read-only |
The number of Bytes the Port received for the interval. |
adTSUIQIntDBUBytesTx | 1.3.6.1.4.1.664.2.147.11.1.1.5 | counter | read-only |
The number of Bytes the Port transmitted for the interval. |
adTSUIQIntDBUAvgThruputTx | 1.3.6.1.4.1.664.2.147.11.1.1.6 | gauge | read-only |
The Average Throughput the Port transmitted for the interval. |
adTSUIQIntDBUAvgThruputRx | 1.3.6.1.4.1.664.2.147.11.1.1.7 | gauge | read-only |
The Average Throughput the Port received for the interval. |
adTSUIQIntDBUMaxThruputTx | 1.3.6.1.4.1.664.2.147.11.1.1.8 | counter | read-only |
The Maximum Throughput the Port transmitted for the interval. |
adTSUIQIntDBUMaxThruputRx | 1.3.6.1.4.1.664.2.147.11.1.1.9 | counter | read-only |
The Maximum Throughput the Port received for the interval. |
adTSUIQIntDBUAvgUtilizationTx | 1.3.6.1.4.1.664.2.147.11.1.1.10 | gauge | read-only |
The Average Utilization the Port transmitted for the interval. |
adTSUIQIntDBUAvgUtilizationRx | 1.3.6.1.4.1.664.2.147.11.1.1.11 | gauge | read-only |
The Average Utilization the Port received for the interval. |
adTSUIQIntDBUMaxUtilizationTx | 1.3.6.1.4.1.664.2.147.11.1.1.12 | counter | read-only |
The Maximum Utilization the Port transmitted for the interval. |
adTSUIQIntDBUMaxUtilizationRx | 1.3.6.1.4.1.664.2.147.11.1.1.13 | counter | read-only |
The Maximum Utilization the Port received for the interval. |
adTSUIQIntTimeInDBU | 1.3.6.1.4.1.664.2.147.11.1.1.14 | counter | read-only |
Time in seconds the DBU port was active. |
adTSUIQIntDBUCrcErrors | 1.3.6.1.4.1.664.2.147.11.1.1.15 | counter | read-only |
Number of frames received with CRC errors. |
adTSUIQIntDBUAbortFrames | 1.3.6.1.4.1.664.2.147.11.1.1.16 | counter | read-only |
Number of frames received without proper flag termination. |
adTSUIQIntDBUOctectViolations | 1.3.6.1.4.1.664.2.147.11.1.1.17 | counter | read-only |
Number of frames received with a bit count not divisible by eigth. |
adTSUIQIntDBUDiscardFrames | 1.3.6.1.4.1.664.2.147.11.1.1.18 | counter | read-only |
Number of frames discarded by the IQ unit |
adTSUIQIntDBULengthErrors | 1.3.6.1.4.1.664.2.147.11.1.1.19 | counter | read-only |
Number of frames received that is less than 5 bytes or greater than 4500 bytes. |
adTSUIQIntDBUEncapsulationErrors | 1.3.6.1.4.1.664.2.147.11.1.1.20 | counter | read-only |
Number of frames destined for the IQ IP stack with that does not meet the FRF.3 IA. |
adTSUIQIntDBUUnroutable | 1.3.6.1.4.1.664.2.147.11.1.1.21 | counter | read-only |
Number of frames received on a management DLCI destined for the IQ unit and have the wrong IP address. |
adTSUIQDayDBUStatus | 1.3.6.1.4.1.664.2.147.12 | |||
adTSUIQDayDBUStatusTable | 1.3.6.1.4.1.664.2.147.12.1 | no-access |
n/a. |
|
1.3.6.1.4.1.664.2.147.12.1.1 | no-access |
n/a |
||
adTSUIQDayDBUSlotIndex | 1.3.6.1.4.1.664.2.147.12.1.1.1 | integer | read-only |
n/a. |
adTSUIQDayDBUFramesRx | 1.3.6.1.4.1.664.2.147.12.1.1.2 | counter | read-only |
The number of Frames the Port received for the interval. |
adTSUIQDayDBUFramesTx | 1.3.6.1.4.1.664.2.147.12.1.1.3 | counter | read-only |
The number of Frames the Port transmitted for the interval. |
adTSUIQDayDBUBytesRx | 1.3.6.1.4.1.664.2.147.12.1.1.4 | counter | read-only |
The number of Bytes the Port received for the interval. |
adTSUIQDayDBUBytesTx | 1.3.6.1.4.1.664.2.147.12.1.1.5 | counter | read-only |
The number of Bytes the Port transmitted for the interval. |
adTSUIQDayDBUAvgThruputTx | 1.3.6.1.4.1.664.2.147.12.1.1.6 | gauge | read-only |
The Average Throughput the Port transmitted for the interval. |
adTSUIQDayDBUAvgThruputRx | 1.3.6.1.4.1.664.2.147.12.1.1.7 | gauge | read-only |
The Average Throughput the Port received for the interval. |
adTSUIQDayDBUMaxThruputTx | 1.3.6.1.4.1.664.2.147.12.1.1.8 | counter | read-only |
The Maximum Throughput the Port transmitted for the interval. |
adTSUIQDayDBUMaxThruputRx | 1.3.6.1.4.1.664.2.147.12.1.1.9 | counter | read-only |
The Maximum Throughput the Port received for the interval. |
adTSUIQDayDBUAvgUtilizationTx | 1.3.6.1.4.1.664.2.147.12.1.1.10 | gauge | read-only |
The Average Utilization the Port transmitted for the interval. |
adTSUIQDayDBUAvgUtilizationRx | 1.3.6.1.4.1.664.2.147.12.1.1.11 | gauge | read-only |
The Average Utilization the Port received for the interval. |
adTSUIQDayDBUMaxUtilizationTx | 1.3.6.1.4.1.664.2.147.12.1.1.12 | counter | read-only |
The Maximum Utilization the Port transmitted for the interval. |
adTSUIQDayDBUMaxUtilizationRx | 1.3.6.1.4.1.664.2.147.12.1.1.13 | counter | read-only |
The Maximum Utilization the Port received for the interval. |
adTSUIQDayTimeInDBU | 1.3.6.1.4.1.664.2.147.12.1.1.14 | counter | read-only |
Time in seconds the DBU port was active. |
adTSUIQDayDBUCrcErrors | 1.3.6.1.4.1.664.2.147.12.1.1.15 | counter | read-only |
Number of frames received with CRC errors. |
adTSUIQDayDBUAbortFrames | 1.3.6.1.4.1.664.2.147.12.1.1.16 | counter | read-only |
Number of frames received without proper flag termination. |
adTSUIQDayDBUOctectViolations | 1.3.6.1.4.1.664.2.147.12.1.1.17 | counter | read-only |
Number of frames received with a bit count not divisible by eigth. |
adTSUIQDayDBUDiscardFrames | 1.3.6.1.4.1.664.2.147.12.1.1.18 | counter | read-only |
Number of frames discarded by the IQ unit |
adTSUIQDayDBULengthErrors | 1.3.6.1.4.1.664.2.147.12.1.1.19 | counter | read-only |
Number of frames received that is less than 5 bytes or greater than 4500 bytes. |
adTSUIQDayDBUEncapsulationErrors | 1.3.6.1.4.1.664.2.147.12.1.1.20 | counter | read-only |
Number of frames destined for the IQ IP stack with that does not meet the FRF.3 IA. |
adTSUIQDayDBUUnroutable | 1.3.6.1.4.1.664.2.147.12.1.1.21 | counter | read-only |
Number of frames received on a management DLCI destined for the IQ unit and have the wrong IP address. |
adTSUIQTrapManager | 1.3.6.1.4.1.664.2.147.13 | |||
adTSUIQTrapManagerTable | 1.3.6.1.4.1.664.2.147.13.1 | no-access |
The trap manger route table. |
|
1.3.6.1.4.1.664.2.147.13.1.1 | no-access |
n/a |
||
adTSUIQTrapManagerRouteIndex | 1.3.6.1.4.1.664.2.147.13.1.1.1 | integer | read-only |
n/a. |
adTSUIQTrapManagerRouteIPAddress | 1.3.6.1.4.1.664.2.147.13.1.1.2 | ipaddress | read-write |
Sets the Trap Manager IP Address. |
adTSUIQTrapManagerRouteDLCI | 1.3.6.1.4.1.664.2.147.13.1.1.3 | integer | read-write |
Sets the Trap Manager DLCI. (Range 16 - 1007). |
adTSUIQTrapManagerRoutePort | 1.3.6.1.4.1.664.2.147.13.1.1.4 | integer | read-write |
Selects the Trap Manager Port. Enumeration: 'networkPort': 3, 'controlPort': 4, 'none': 1, 'ethernetPort': 5, 'dtePort': 2. |