ADTRAN-ATLAS-VOICE-MIB: View SNMP OID List / Download MIB

VENDOR: ADTRAN


 Home MIB: ADTRAN-ATLAS-VOICE-MIB
Download as:   

Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
 adtran 1.3.6.1.4.1.664
         adMgmt 1.3.6.1.4.1.664.2
             adATLASmg 1.3.6.1.4.1.664.2.154
                     adGenATLASmg 1.3.6.1.4.1.664.2.154.1
                         adATLASVoicemg 1.3.6.1.4.1.664.2.154.1.10
                               adATLASVoiceIfNumber 1.3.6.1.4.1.664.2.154.1.10.1 integer read-only
The number of voice ports (regardless of their current state) present on this system.
                               adATLASVoiceIfTable 1.3.6.1.4.1.664.2.154.1.10.2 no-access
The ATLAS Voice Interface Status Table
                                   adATLASVoiceIfEntry 1.3.6.1.4.1.664.2.154.1.10.2.1 no-access
An entry in the ATLAS Voice Interface Status Table
                                       adATLASVoiceIfIndex 1.3.6.1.4.1.664.2.154.1.10.2.1.1 integer read-only
The index value which uniquely identifies the object instance.
                                       adATLASVoiceIfSlotNum 1.3.6.1.4.1.664.2.154.1.10.2.1.2 integer read-only
This variable indicates the slot number of a particular ATLAS module with a voice interface.
                                       adATLASVoiceIfPortNum 1.3.6.1.4.1.664.2.154.1.10.2.1.3 integer read-only
This variable indicates the port number of a particular voice interface on an ATLAS module.
                                       adATLASVoiceIfPortStat 1.3.6.1.4.1.664.2.154.1.10.2.1.4 integer read-only
This variable indicates the call or port status of a particular voice interface on an ATLAS module. Applicable voice interfaces for each option follow: 1 - 4 FXS, FXO, E&M 5 - 8 FXS, FXO 9 - 15 FXS 16 - 20 FXO 21 - 24 E&M Enumeration: 'testELeadClosed': 23, 'testRingOffhook': 15, 'testActive': 8, 'transOnly': 21, 'disabled': 2, 'testRevBatt': 10, 'testLCRevTRPolarity': 19, 'testDisabled': 14, 'testOffhook': 9, 'testTipOpen': 12, 'testLCNormTRPolarity': 17, 'testLO': 16, 'testRingGND': 20, 'test': 4, 'offhook': 6, 'tipOpen': 5, 'testRinging': 11, 'testTipOpenRingGND': 13, 'testLCNoBatt': 18, 'testELeadOpen': 22, 'reverseBattery': 7, 'callInProgress': 24, 'idle': 3, 'inactive': 1.
                                       adATLASVoiceIfTxSignalBits 1.3.6.1.4.1.664.2.154.1.10.2.1.5 displaystring read-only
Transmit signaling bits: ABCD represented as a character string of 1's and 0's.
                                       adATLASVoiceIfRxSignalBits 1.3.6.1.4.1.664.2.154.1.10.2.1.6 displaystring read-only
Receive signaling bits: ABCD represented as a character string of 1's and 0's.
                               adATLASVoiceTstTable 1.3.6.1.4.1.664.2.154.1.10.3 no-access
The ATLAS Voice Interface Test Table
                                   adATLASVoiceTstEntry 1.3.6.1.4.1.664.2.154.1.10.3.1 no-access
An entry in the ATLAS Voice Interface Test Table
                                       adATLASVoiceTstIndex 1.3.6.1.4.1.664.2.154.1.10.3.1.1 integer read-only
The index value which uniquely identifies the object instance.
                                       adATLASVoiceTst2W 1.3.6.1.4.1.664.2.154.1.10.3.1.2 integer read-write
This variable indicates the 2 Wire Test setting on a particular voice interface on an ATLAS module. Applicable voice interfaces for each option follow: 1 FXS, FXO, E&M 2 - 4 FXO 5 - 9 FXS 10 - 11 E&M Enumeration: 'eLeadClosed': 11, 'loopClosed': 3, 'ringing': 9, 'eLeadOpen': 10, 'reverseBattery': 7, 'loopOpen': 2, 'disable': 8, 'active': 5, 'off': 1, 'tipOpen': 6, 'ringGround': 4.
                                       adATLASVoiceTstTxABCD 1.3.6.1.4.1.664.2.154.1.10.3.1.3 integer read-write
This variable indicates the Transmit Signaling Bits Test setting on a particular voice interface on an ATLAS module. Enumeration: 'tx0000': 2, 'tx1010': 4, 'tx0101': 3, 'txOff': 1, 'tx1111': 5.
                                       adATLASVoiceTst1kHzTone 1.3.6.1.4.1.664.2.154.1.10.3.1.4 integer read-write
This variable indicates the Tone Test setting on a particular voice interface on an ATLAS module. Near is for sending tone towards the 2W port. Far is for sending tone towards the PCM (DS0 or B-Channel). Enumeration: 'far': 3, 'near': 2, 'off': 1.
                                       adATLASVoiceTstLpBk 1.3.6.1.4.1.664.2.154.1.10.3.1.5 integer read-write
This variable indicates the Loopback Test setting on a particular voice interface on an ATLAS module. Enumeration: 'off': 1, 'analog': 2, 'digital': 3.