ADC-FLEXWAVE-URH-MIB: View SNMP OID List / Download MIB

VENDOR: ADC TELECOMMUNICATIONS


 Home MIB: ADC-FLEXWAVE-URH-MIB
Download as:   

Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
 adc 1.3.6.1.4.1.2014
           flexwave 1.3.6.1.4.1.2014.15
                 flexwaveurh 1.3.6.1.4.1.2014.15.2
                     flexwaveURHMibModule 1.3.6.1.4.1.2014.15.2.1
This is the MIB for managing entities associated with FlexWave Prism & InterReach SPECTRUM products for SW Version 8.1
                         fwuHostUnitObjects 1.3.6.1.4.1.2014.15.2.1.1
                             fwuHstSystemLevelObjects 1.3.6.1.4.1.2014.15.2.1.1.1
                                 fwuHstSystemLevelInfo 1.3.6.1.4.1.2014.15.2.1.1.1.1
                                     fwuHstGeneral 1.3.6.1.4.1.2014.15.2.1.1.1.1.1
                                         fwuHstNumber 1.3.6.1.4.1.2014.15.2.1.1.1.1.1.1 integer read-only
Host Number.
                                         fwuHstName 1.3.6.1.4.1.2014.15.2.1.1.1.1.1.2 displaystring read-write
User defined name of the host unit. All characters except angular brackets, single and double quotes are allowed. Minimum length of the name is 1 character. Maximum length of the name 64 characters.
                                         fwuHstUnitReset 1.3.6.1.4.1.2014.15.2.1.1.1.1.1.3 integer read-write
Use to reset the Host. Do this by changing from normal(0) to reset(1). After the operation has completed the state automatically changes to normal. Enumeration: 'reset': 1, 'normal': 0.
                                         fwuHstBackPlaneRev 1.3.6.1.4.1.2014.15.2.1.1.1.1.1.4 displaystring read-only
The back plane revision of the Host (It is the three pin version number of the chassis back plane).
                                         fwuHstAlarmStatusSummary 1.3.6.1.4.1.2014.15.2.1.1.1.1.1.5 alarmtype read-only
Summary of alarm status on the Host.
                                         fwuHstTempMeas 1.3.6.1.4.1.2014.15.2.1.1.1.1.1.6 displaystring read-only
Host system temperature value in Celsius.
                                         fwuSystemAlarmStatusSummary 1.3.6.1.4.1.2014.15.2.1.1.1.1.1.7 alarmtype read-only
Summary of alarm status on the System. If there a unit in the system (Host and all remotes) with a fault condition, it will be reflected here. Severity is summarised by the highest severity of the alarms in the system. i.e. If there is at least one Major alarm, the summary will indicate Major Alarm. The severities supported are Major, Minor and OK.
                                         fwuHstSystemDateAndTime 1.3.6.1.4.1.2014.15.2.1.1.1.1.1.9 octet string read-write
Date and Time settings on the system.
                                         fwuAlarmAck 1.3.6.1.4.1.2014.15.2.1.1.1.1.1.11 integer read-write
Provision to acknowledgement one or all alarms in the system. Set 0 to acknowledge all alarms or the alarm code (numeric ID) of the alarm to be acknowledged. This is a integer greater than 0. Enumeration: 'acknowledgeAll': 0.
                                         fwuAlarmLevel 1.3.6.1.4.1.2014.15.2.1.1.1.1.1.12 alarmtype read-write
Alarm status summary of system.
                                         fwuUserCommLinkTest 1.3.6.1.4.1.2014.15.2.1.1.1.1.1.13 integer read-write
Provision to perform the system test manually. Set the value to 1 to initiate the test. Once started, the test cannot be cancelled. User has to wait for completion. On completion of the test, the value reverts back to 0. Use fwuUserCommLinkTestDartBandType or fwuUserCommLinkTestDartId to provide parameters for the test. Enumeration: 'start': 1, 'inactive': 0.
                                         fwuUserLinkTestStatus 1.3.6.1.4.1.2014.15.2.1.1.1.1.1.14 displaystring read-only
Provides the status of the System/Link test, once the test has started. Start the test using fwuUserCommLinkTest. Status is reported in the format X;Y where X is the test status (number) and Y is the unit number. The valid values of the test status and their associated meaning. (0) - Test has not started. This is the default value. (1) - Test started. (2,3,4,5,6,7,8,9,10,11,12,13,14) - Test is in progress. (15) - Test completed. (16) - Test Failed.
                                         fwuUserCommLinkTestDartBandType 1.3.6.1.4.1.2014.15.2.1.1.1.1.1.15 bandtype read-write
Bands on which the system test is to be run. Refer TC BANDType for list. 0 to select all provisioned bands for the test. If a non-zero value is provided here then fwuUserCommLinkTestDartId must be empty. If zero is provided here then fwuUserCommLinkTestDartId may be set to 0 or empty.
                                         fwuUserCommLinkTestDartId 1.3.6.1.4.1.2014.15.2.1.1.1.1.1.16 integer32 read-write
Identify the DARTs on which the system test is to be run. It is the DART slot number on Host unit. Use 0 to select all provisioned DARTs for the test. Other valid values are 1 to 8 and -1. If a non-zero value is provided here then fwuUserCommLinkTestDartBandType must be empty. If zero is provided here then fwuUserCommLinkTestDartBandType may be set to 0 or empty.
                                         fwuClearSysConfig 1.3.6.1.4.1.2014.15.2.1.1.1.1.1.17 integer read-write
To Clear System Configuration. Change the value from 0 to 1 to clear all the settings on the system. Also, known as Restore To Factory Defaults (RTFD). Enumeration: 'enable': 1, 'disable': 0.
                                         fwuLinkTestLastRuntime 1.3.6.1.4.1.2014.15.2.1.1.1.1.1.19 dateandtime read-only
Time indicating the most recent execution of System/Link Test.
                                         fwuNTPServerIP 1.3.6.1.4.1.2014.15.2.1.1.1.1.1.20 displaystring read-write
IP address of NTP Server. Use internet dot-decimal notation when providing the address.
                                         fwuSyncNTPServer 1.3.6.1.4.1.2014.15.2.1.1.1.1.1.21 integer read-write
Enable synchronization with NTP server. Change the value from 0 to 1 to enable synchronization with the NTP Server. Enumeration: 'enable': 1, 'disable': 0.
                                     fwuHstExt 1.3.6.1.4.1.2014.15.2.1.1.1.1.2
                                         fwuHstMajorContactAlarmOutput 1.3.6.1.4.1.2014.15.2.1.1.1.1.2.1 contacttype read-only
Host Major contact output port state. Not present, OK and faulted are the supported states.
                                         fwuHstMinorContactAlarmOutput 1.3.6.1.4.1.2014.15.2.1.1.1.1.2.2 contacttype read-only
Host Minor contact output port state. Not present, OK and faulted are the supported states.
                                         fwuRmtMajorContactAlarmOutput 1.3.6.1.4.1.2014.15.2.1.1.1.1.2.3 contacttype read-only
Remote Major contact output port state. Not present, OK and faulted are the supported states.
                                         fwuRmtMinorContactAlarmOutput 1.3.6.1.4.1.2014.15.2.1.1.1.1.2.4 contacttype read-only
Remote Minor contact output port state. Not present, OK and faulted are the supported states.
                                     fwuSystemActiveAlarms 1.3.6.1.4.1.2014.15.2.1.1.1.1.3
                                         fwuSystemActiveAlarmTable 1.3.6.1.4.1.2014.15.2.1.1.1.1.3.1 no-access
This table lists all the outstanding (active) alarms in the system. Alarms are removed from this table when the alarm condition is cleared (i.e. When CLEAR is sent out).
                                             fwuSystemActiveAlarmEntry 1.3.6.1.4.1.2014.15.2.1.1.1.1.3.1.1 no-access
Entries for active alarms.
                                                 fwuSystemAlarmSequenceNumber 1.3.6.1.4.1.2014.15.2.1.1.1.1.3.1.1.1 unsigned32 no-access
The number of the alarm table entry which is defined by this row.
                                                 fwuSystemAlarmTrapNodeAddress 1.3.6.1.4.1.2014.15.2.1.1.1.1.3.1.1.2 unitid2 read-only
System Node Address, where the alarm originated.
                                                 fwuSystemlabel 1.3.6.1.4.1.2014.15.2.1.1.1.1.3.1.1.3 displaystring read-only
The name used to identify the system. Since the Host name is used to identify the system, the Host name is reflected here.
                                                 fwuSystemAlarmRmtName 1.3.6.1.4.1.2014.15.2.1.1.1.1.3.1.1.4 displaystring read-only
Name of the unit from which the alarm originated.
                                                 fwuSystemAlarmRmtType 1.3.6.1.4.1.2014.15.2.1.1.1.1.3.1.1.5 unittype read-only
Type of the unit from which the alarm originated. fwuSystemAlarmRmtName is the user provided name of this unit.
                                                 fwuSystemAlarmModuleType 1.3.6.1.4.1.2014.15.2.1.1.1.1.3.1.1.6 moduletype read-only
Type of the Module from which the alarm originated. e.g SeRF, DART, SFP. To be read with fwuSystemAlarmRmtType. Then, it identifies the module on that (fwuSystemAlarmRmtType) unit.
                                                 fwuSystemAlarmModuleNumber 1.3.6.1.4.1.2014.15.2.1.1.1.1.3.1.1.7 unsigned32 read-only
Number of the module from which the alarm originated. To be used in conjuction with the object fwuSystemAlarmModuleType. So, if module type indicated DART and module number reported 3, then it means that the alarm originated from the third DART.
                                                 fwuSystemAlarmModuleName 1.3.6.1.4.1.2014.15.2.1.1.1.1.3.1.1.8 displaystring read-only
Name of the Module from which the alarm originated. The user provided name of the module identified by fwuSystemAlarmModuleNumber.
                                                 fwuSystemAlarmSeverity 1.3.6.1.4.1.2014.15.2.1.1.1.1.3.1.1.9 alarmtype read-only
Severity of the alarm.
                                                 fwuSystemAlarmRFBand 1.3.6.1.4.1.2014.15.2.1.1.1.1.3.1.1.10 displaystring read-only
The RF band affected by this alarm condition.
                                                 fwuSystemAlarmTimeStamp 1.3.6.1.4.1.2014.15.2.1.1.1.1.3.1.1.11 dateandtime read-only
Time when the alarm is raised.
                                                 fwuSystemAlarmCode 1.3.6.1.4.1.2014.15.2.1.1.1.1.3.1.1.12 unsigned32 read-only
A positive number which uniquely identifies an alarm.
                                                 fwuSystemAlarmHstNbr 1.3.6.1.4.1.2014.15.2.1.1.1.1.3.1.1.13 unsigned32 read-only
Number identifying the host in the system.
                                                 fwuSystemAlarmAnalogAddress 1.3.6.1.4.1.2014.15.2.1.1.1.1.3.1.1.14 unitid3 read-only
Analog Portion of the node address.
                                 fwuHstSystemLevelTraps 1.3.6.1.4.1.2014.15.2.1.1.1.2
                                     fwuHstModuleMissingFault 1.3.6.1.4.1.2014.15.2.1.1.1.2.2
Missing Host pluggable module.
                                     fwuHstOverTempFault 1.3.6.1.4.1.2014.15.2.1.1.1.2.3
Host Temperature above operating limit.
                                     fwuHstUnderTempFault 1.3.6.1.4.1.2014.15.2.1.1.1.2.4
Host Temperature below operating limit.
                                     fwuHstBTSUnderPowerFault 1.3.6.1.4.1.2014.15.2.1.1.1.2.5
Band specific alarm FLM raised when unit connected to BTS.
                                     fwuHstFLMDownconvertFailureFault 1.3.6.1.4.1.2014.15.2.1.1.1.2.6
Forward Link Monitor (FLM) fault active.
                                     fwuHstRLMUpconvertFailureFault 1.3.6.1.4.1.2014.15.2.1.1.1.2.7
Band specific alarm RLM raised when unit connected to BTS.
                                     fwuHstRLMUpConIndetFault 1.3.6.1.4.1.2014.15.2.1.1.1.2.8
Unable to run RLM due to Host Reverse gain being set too low.
                                     fwuHstIamAliveFault 1.3.6.1.4.1.2014.15.2.1.1.1.2.9
The Host I am alive Trap
                             fwuHstSERFObjects 1.3.6.1.4.1.2014.15.2.1.1.2
                                 fwuHstSERFInfo 1.3.6.1.4.1.2014.15.2.1.1.2.1
                                     fwuHstSERFGeneral 1.3.6.1.4.1.2014.15.2.1.1.2.1.1
                                         fwuHstSERFLinuxKernelVer 1.3.6.1.4.1.2014.15.2.1.1.2.1.1.1 displaystring read-only
Linux Kernel version on host.
                                         fwuHstSERFLinuxBootLoaderVer 1.3.6.1.4.1.2014.15.2.1.1.2.1.1.2 displaystring read-only
Boot Loader1 version on host.
                                         fwuHstSERFCompactFlashSWVer 1.3.6.1.4.1.2014.15.2.1.1.2.1.1.3 displaystring read-only
Compact Flash version on host.
                                         fwuHstSERFFPGAVer 1.3.6.1.4.1.2014.15.2.1.1.2.1.1.4 displaystring read-only
FPGA version loaded on Host SeRF.
                                         fwuHstSERFPPCSNMPAgentSWVer 1.3.6.1.4.1.2014.15.2.1.1.2.1.1.5 displaystring read-only
SNMP agent version on host.
                                         fwuHstSERFPPCHWMonSWVer 1.3.6.1.4.1.2014.15.2.1.1.2.1.1.6 displaystring read-only
Hardware Monitor process version on host.
                                         fwuHstSERFPPCAPPMonSWVer 1.3.6.1.4.1.2014.15.2.1.1.2.1.1.7 displaystring read-only
Application Monitor process version on host.
                                         fwuHstSERFPPCMATEMonSWVer 1.3.6.1.4.1.2014.15.2.1.1.2.1.1.8 displaystring read-only
Mate Monitor process version on host.
                                         fwuHstSERFPPCENETMonSWVer 1.3.6.1.4.1.2014.15.2.1.1.2.1.1.9 displaystring read-only
Ethernet Monitor process version on host.
                                         fwuHstSERFPPCFPGAMonSWVer 1.3.6.1.4.1.2014.15.2.1.1.2.1.1.10 displaystring read-only
FPGA Monitor process version on host.
                                         fwuHstSERFRIDateCode 1.3.6.1.4.1.2014.15.2.1.1.2.1.1.11 displaystring read-only
Host SeRF Inventory - Date Code.
                                         fwuHstSERFRIHWVer 1.3.6.1.4.1.2014.15.2.1.1.2.1.1.12 displaystring read-only
Host SeRF Inventory - Hardware version.
                                         fwuHstSERFRISerialNumber 1.3.6.1.4.1.2014.15.2.1.1.2.1.1.13 displaystring read-only
Host SeRF Inventory - Serial Number.
                                         fwuHstSERFRIADCPartNumber 1.3.6.1.4.1.2014.15.2.1.1.2.1.1.14 displaystring read-only
Host SeRF Inventory - TE PartNumber.
                                         fwuHstSERFRIHWGen 1.3.6.1.4.1.2014.15.2.1.1.2.1.1.15 integer read-only
Host SeRF Hardware Generation. Enumeration: 'secondGeneration': 1, 'firstGeneration': 0.
                                         fwuHstSERFLinuxBootLoaderFirstVer 1.3.6.1.4.1.2014.15.2.1.1.2.1.1.16 displaystring read-only
Boot Loader2 version of the host system.
                                         fwuHstpThreadSWVer 1.3.6.1.4.1.2014.15.2.1.1.2.1.1.17 displaystring read-only
The version number of pThread process. If blank then pThread does not run here.
                                         fwuHstSubagentSWVer 1.3.6.1.4.1.2014.15.2.1.1.2.1.1.18 displaystring read-only
The version number of the subagent.
                                         fwuHstWebServerSWVer 1.3.6.1.4.1.2014.15.2.1.1.2.1.1.19 displaystring read-only
The version number of web server.
                                     fwuHstSERFOptObjects 1.3.6.1.4.1.2014.15.2.1.1.2.1.2
                                         fwuHstSERFOptTable 1.3.6.1.4.1.2014.15.2.1.1.2.1.2.1 no-access
This table maintains Information of Host SERF Optical Objects.
                                             fwuHstSERFOptEntry 1.3.6.1.4.1.2014.15.2.1.1.2.1.2.1.1 no-access
Each entry in this table refers to Host SERF Optical objects.
                                                 fwuHstSERFOptSFPNumber 1.3.6.1.4.1.2014.15.2.1.1.2.1.2.1.1.1 integer32 read-only
SFP Number - Optical Port number.
                                                 fwuHstSERFOptSFPName 1.3.6.1.4.1.2014.15.2.1.1.2.1.2.1.1.2 displaystring read-write
User defined name of each Host SFP. All characters except angular brackets, single and double quotes are allowed. Minimum length of the name is 1 character. Maximum length of the name 64 characters.
                                                 fwuHstSERFOptSFPType 1.3.6.1.4.1.2014.15.2.1.1.2.1.2.1.1.3 opticstype read-only
SFP Type - Optical Port Type. Identifies whether the SFP is short(1)/intermediate(2)/long(3) range. It may also be unidentified (-1).
                                                 fwuHstSERFOptSFPTxColor 1.3.6.1.4.1.2014.15.2.1.1.2.1.2.1.1.4 integer32 read-only
Wavelength of light used in the SFP (in nanometers).
                                                 fwuHstSERFOptRevLaunchPowerMeas 1.3.6.1.4.1.2014.15.2.1.1.2.1.2.1.1.5 displaystring read-only
Value of the optical power, in dBm received at the host.
                                                 fwuHstSERFOptFwdLaunchPowerMeas 1.3.6.1.4.1.2014.15.2.1.1.2.1.2.1.1.6 displaystring read-only
Value of the optical power, in dBm transmitted by the host.
                                                 fwuHstSERFOptMateName 1.3.6.1.4.1.2014.15.2.1.1.2.1.2.1.1.7 displaystring read-only
Name of Host Mates.
                                                 fwuHstSERFIPEnable 1.3.6.1.4.1.2014.15.2.1.1.2.1.2.1.1.8 integer read-only
Indicates whether IP is enabled(1) or not(2). Enumeration: 'iPDisable': 2, 'iPEnable': 1.
                                                 fwuHstSERFOptMateId 1.3.6.1.4.1.2014.15.2.1.1.2.1.2.1.1.9 unitid2 read-only
Identifier of (companion) mate unit.
                                                 fwuHstSERFOptMateSfpId 1.3.6.1.4.1.2014.15.2.1.1.2.1.2.1.1.10 integer32 read-only
SFP slot number used at remote end.
                                 fwuHstSERFTraps 1.3.6.1.4.1.2014.15.2.1.1.2.2
                                     fwuHstSERFSynthAlarmFault 1.3.6.1.4.1.2014.15.2.1.1.2.2.2
Host SeRF synthesizer unlocked.
                                     fwuHstSERFFault 1.3.6.1.4.1.2014.15.2.1.1.2.2.3
Summary of SeRF Synthesizer Unlocked alarm and SeRF FPGA status. The system may not be communicating with the Ethernet Switch. This fault is also precipitated by the I2C Bus Fault.
                                     fwuHstSERFRmtLostFault 1.3.6.1.4.1.2014.15.2.1.1.2.2.4
Remote is not communicating with Host.
                                     fwuHstSERFOptRxBERFault 1.3.6.1.4.1.2014.15.2.1.1.2.2.5
High bit error rate (BER) detected by fiber optic receiver.
                                     fwuHstSERFOptRxNoLightFault 1.3.6.1.4.1.2014.15.2.1.1.2.2.6
No signal detected by optical receiver.
                                     fwuHstSERFOptLaserFault 1.3.6.1.4.1.2014.15.2.1.1.2.2.7
SFP optical transmitter failed.
                                     fwuHstSERFOptOverDriveFault 1.3.6.1.4.1.2014.15.2.1.1.2.2.8
SFP optical receive input power above specification.
                                     fwuHstSERFOptUnderDriveFault 1.3.6.1.4.1.2014.15.2.1.1.2.2.9
SFP optical receive input power below specification.
                                     fwuHstSERFOptIpEnableFault 1.3.6.1.4.1.2014.15.2.1.1.2.2.10
Host SFP IPEnable Fault.
                                     fwuMastClockPriorityLvlConflict 1.3.6.1.4.1.2014.15.2.1.1.2.2.11
More than one Host has the same Master Clock Priority Level. All Hosts in conflict raise the alarm.
                                     fwuHstI2CBus1Fault 1.3.6.1.4.1.2014.15.2.1.1.2.2.12
Indicates an I2C communication problem.
                                     fwuHstI2CBus2Fault 1.3.6.1.4.1.2014.15.2.1.1.2.2.13
Indicates an I2C communication problem.
                             fwuHstSERFEthPortObjects 1.3.6.1.4.1.2014.15.2.1.1.3
                                 fwuHstSERFEthPortInfo 1.3.6.1.4.1.2014.15.2.1.1.3.1
                                     fwuHstSERFEthPortTable 1.3.6.1.4.1.2014.15.2.1.1.3.1.1 no-access
This table maintains information of Host Ethernet Ports.
                                         fwuHstSERFEthPortEntry 1.3.6.1.4.1.2014.15.2.1.1.3.1.1.1 no-access
Each entry in this table refers to Host SERF Ethernet port objects.
                                             fwuHstSERFEthPortNumber 1.3.6.1.4.1.2014.15.2.1.1.3.1.1.1.1 unsigned32 read-only
A unique identifier for each Ethernet port.
                                             fwuHstSERFEthPortType 1.3.6.1.4.1.2014.15.2.1.1.3.1.1.1.2 enettype read-only
An identifier for the type of Ethernet port. The port types are network(1), craft(2) , management(3) , switch(4) , SFP(5). It may be unknown (-1).
                                             fwuHstSERFEthPortRxBytes 1.3.6.1.4.1.2014.15.2.1.1.3.1.1.1.3 counter64 read-only
Count of the number of recieved bytes at this ethernet port.
                                             fwuHstSERFEthPortRxPkts 1.3.6.1.4.1.2014.15.2.1.1.3.1.1.1.4 counter64 read-only
The number of packets recieved at this ethernet port.
                                             fwuHstSERFEthPortRxFcsErrors 1.3.6.1.4.1.2014.15.2.1.1.3.1.1.1.5 counter64 read-only
The number of FCS errors recieved at this ethernet port.
                                             fwuHstSERFEthPortRxBroadcastPkts 1.3.6.1.4.1.2014.15.2.1.1.3.1.1.1.6 counter64 read-only
The number of broadcast packets recieved at this ethernet port.
                                             fwuHstSERFEthPortRxMulticastPkts 1.3.6.1.4.1.2014.15.2.1.1.3.1.1.1.7 counter64 read-only
The number of multicast packets at this ethernet port.
                                             fwuHstSERFEthPortRxFragmtdFrames 1.3.6.1.4.1.2014.15.2.1.1.3.1.1.1.8 counter64 read-only
The number of fragmented frames received at this ethernet port.
                                             fwuHstSERFEthPortRxJabbersFrames 1.3.6.1.4.1.2014.15.2.1.1.3.1.1.1.9 counter64 read-only
The number of jabber frames received at this ethernet port.
                                             fwuHstSERFEthPortTxByteCounter 1.3.6.1.4.1.2014.15.2.1.1.3.1.1.1.10 counter64 read-only
The number of bytes transmitted from this ethernet port.
                                             fwuHstSERFEthPortTxPkts 1.3.6.1.4.1.2014.15.2.1.1.3.1.1.1.11 counter64 read-only
The number of packets transmitted from this ethernet port.
                                             fwuHstSERFEthPortTxBroadcastPkts 1.3.6.1.4.1.2014.15.2.1.1.3.1.1.1.12 counter64 read-only
The number of broadcast packets transmitted from this ethernet port.
                                             fwuHstSERFEthPortTxMulticastPkts 1.3.6.1.4.1.2014.15.2.1.1.3.1.1.1.13 counter64 read-only
The number of multicast packets transmitted from this ethernet port.
                                             fwuHstSERFEthPortSFPId 1.3.6.1.4.1.2014.15.2.1.1.3.1.1.1.14 integer32 read-only
Identifies the SFP number to which this ethernet port connects.
                                 fwuHstSERFEthPortTraps 1.3.6.1.4.1.2014.15.2.1.1.3.2
                             fwuHstSERFFPGAObjects 1.3.6.1.4.1.2014.15.2.1.1.4
                                 fwuHstSERFFPGAInfo 1.3.6.1.4.1.2014.15.2.1.1.4.1
                                     fwuHstSERFFPGAStatus 1.3.6.1.4.1.2014.15.2.1.1.4.1.1 integer read-only
Provides the SERF Card FPGA status. The status may be PPC can communicate with the FPGA (0) or not (1). Enumeration: 'ppcCanNotTalkToFPGA': 1, 'ppcCanTalkToFPGA': 0.
                                 fwuHstSERFFPGATraps 1.3.6.1.4.1.2014.15.2.1.1.4.2
                             fwuHstMateMonObjects 1.3.6.1.4.1.2014.15.2.1.1.5
                                 fwuHstMateMonInfo 1.3.6.1.4.1.2014.15.2.1.1.5.1
                                     fwuHstMateMonTable 1.3.6.1.4.1.2014.15.2.1.1.5.1.1 no-access
This table maintains Information of Host Mate Monitor.
                                         fwuHstMateMonEntry 1.3.6.1.4.1.2014.15.2.1.1.5.1.1.1 no-access
Each entry in this table refers to host Mate monitor objects.
                                             fwuHMmonRmtID 1.3.6.1.4.1.2014.15.2.1.1.5.1.1.1.1 unitid2 read-only
ID of companion remote unit as Index of mate monitor table.
                                             fwuHMmonRmtIPAddress 1.3.6.1.4.1.2014.15.2.1.1.5.1.1.1.2 octet string read-only
IP addresses of remote mate. This is a link-local address.
                             fwuHstDARTObjects 1.3.6.1.4.1.2014.15.2.1.1.6
                                 fwuHstDARTInfo 1.3.6.1.4.1.2014.15.2.1.1.6.1
                                     fwuHstDARTGeneral 1.3.6.1.4.1.2014.15.2.1.1.6.1.1
                                         fwuHstDARTGeneralTable 1.3.6.1.4.1.2014.15.2.1.1.6.1.1.1 no-access
This table maintains Information of Host DART Card.
                                             fwuHstDARTGeneralEntry 1.3.6.1.4.1.2014.15.2.1.1.6.1.1.1.1 no-access
Each entry in this table refers to host DART Card objects.
                                                 fwuHstDARTNumber 1.3.6.1.4.1.2014.15.2.1.1.6.1.1.1.1.1 integer32 read-only
A unique identifier for each DART. As there are eight DART slots, the number may be any of 1 to 8.
                                                 fwuHstDARTName 1.3.6.1.4.1.2014.15.2.1.1.6.1.1.1.1.2 displaystring read-only
A user defined name for each DART Card object of host. All characters except angular brackets, single and double quotes are allowed. Minimum length of the name is 1 character. Maximum length of the name 64 characters.
                                                 fwuHstDARTBandType 1.3.6.1.4.1.2014.15.2.1.1.6.1.1.1.1.3 bandtype read-only
Band type of host DART card.
                                                 fwuHstDARTPassBand 1.3.6.1.4.1.2014.15.2.1.1.6.1.1.1.1.4 octet string read-only
This is for configuration of Pass-band type for host DART card. Following input formats are supported for Classic and SuperDart passband configuration. 1. For Classic Darts only, User input string would be enumeration value ( i.e., 'x'), ranging from 1 to 134. See below in section 3. for valid values. 2. For SuperDarts only, a. BandType_SubBand1+SubBand2 This is applicable only for contiguous passband selection, applicable only for PCS & AWS. (e.g., 'PCS_A1+A2+A3') b. BandType_SubBand1+SubBand2:SubBand5+SubBand6 This is applicable for noncontiguous passband selection, applicable only for PCS & AWS. (e.g., 'PCS_A1+A2:C2+C1') c. BandType_StartFrequency-StartFrequency This is applicable only for contiguous passband frequency range. (e.g.,, PCS_1930-1945) d. BandType_StartFrequency1-StartFrequency1:StartFrequency2-StartFrequency2 This is applicable only for noncontiguous passband frequency ranges. (e.g., PCS_1930-1940.5:1960.7-1970.6). Where BandType is 'PCS', 'AWS', 'UMTS','EGSM900','GSM1800', 'UC700', 'LABC700'. 3. Valid enumeration value for classic dart:- undefined(-1), cellularA2A(1),cellularA(2),cellularAA1A2(3),cellularA1(4), cellularB(5),cellularB1(6),cellularBB1(7), pcsA1(8),pcsA2(9),pcsA3(10),pcsB1(11),pcsB2(12),pcsB3(13), pcsC3(14),pcsC4(15),pcsC5(16),pcsD(17),pcsE(18),pcsF(19), pcsG(20),awsH(21),pcsC2(22), pcsC1(23), pcsA1A2(24),pcsA2A3(25),pcsA3D(26),pcsDB1(27),pcsB1B2(28),pcsB2B3(29), pcsB3E(30),pcsEF(31),pcsFC3(32), pcsC3C4(33),pcsC4C5(34), pcsC5G(35),pcsGawsH(36),pcsFC2(37),pcsC1G(38),pcsA(39), pcsA2A3D(40),pcsA3DB1(41), pcsDB1B2(42),pcsB(43),pcsB2B3E(44), pcsB3EF(45),pcsEFC3(46),pcsFC3C4(47),pcsC(48), pcsC4C5G(49), pcsC5GawsH(50),pcsEFC2(51),pcsC1GawsH(52), pcsAD(53),pcsA2A3DB1(54),pcsA3DB1B2(55),pcsDB(56),pcsBE(57), pcsB2B3EF(58),pcsB3EFC3(59),pcsEFC3C4(60),pcsFC(61), pcsCG(62),pcsC4C5GawsH(63),pcsB3EFC2(64), pcsADB1(65),pcsA2A3DB1B2(66),pcsA3DB(67),pcsDBE(68), pcsBEF(69),pcsB2B3EFC3(70),pcsB3EFC3C4(71),pcsEFC(72), pcsFCG(73),pcsCGawsH(74),pcsB2B3EFC2(75), pcsADB1B2(76),pcsA2A3DB(77),pcsA3DBE(78),pcsDBEF(79), pcsBEFC3(80),pcsB2B3EFC3C4(81),pcsB3EFC(82), pcsEFCG(83),pcsFCGawsH(84),pcsADB(85), pcsA2A3DBE(86),pcsA3DBEF(87), pcsDBEFC3(88), pcsBEFC3C4(89),pcsB2B3EFC(90),pcsB3EFCG(91), pcsEFCGawsH(92),smrLow(93) , smrHigh( 94), awsA(95), awsAB(96), awsABC(97), awsABCD(98), awsABCDE(99), awsB(100), awsBC(101), awsBCD(102), awsBCDE(103), awsBCDEF(104), awsC(105), awsCD(106), awsCDE(107), awsCDEF(108), awsD(109), awsDE(110), awsDEF(111), awsE(112), awsEF(113), awsF(114), smrLowWide(115), cellularA2ABA1B1(116), GSM1800Low(117), GSM1800Middle(118), GSM1800High(119), umtsLow(120), umtsMiddle(121), umtsHigh(122), cellularAB(133), apac800iDEN(134).
                                                 fwuHstDARTOperatingMode 1.3.6.1.4.1.2014.15.2.1.1.6.1.1.1.1.5 modetype read-only
Operating mode of the Host DART. The DART may be operating normally (1) or on standby (2). The mode may be undefined (-1).
                                                 fwuHstDARTDiversityStatus 1.3.6.1.4.1.2014.15.2.1.1.6.1.1.1.1.6 integer read-only
Diversity Status of host DART. Enumeration: 'diversity': 1, 'nonDiversity': 0.
                                                 fwuHstDARTForwardGain 1.3.6.1.4.1.2014.15.2.1.1.6.1.1.1.1.7 gaintype read-only
Primary Gain in the forward path of Host DART. The range is 0-31dB with increments in steps of 1dB.
                                                 fwuHstDARTReverseGain 1.3.6.1.4.1.2014.15.2.1.1.6.1.1.1.1.8 gaintype read-only
Primary Gain in the reverse path of Host DART. The range is 0-31dB with increments in steps of 1dB.
                                                 fwuHstDARTFPGAStatus 1.3.6.1.4.1.2014.15.2.1.1.6.1.1.1.1.9 integer read-only
Host DART FPGA Status. It indicates whether the SeRF FPGA can talk to DART FPGA(0) or not (1). Enumeration: 'serfFpgaCanTalkToDARTFpga': 0, 'serfFpgaCannotTalkToDARTFpga': 1.
                                                 fwuHstDARTFPGAProgramVer 1.3.6.1.4.1.2014.15.2.1.1.6.1.1.1.1.10 displaystring read-only
FPGA Version on the Host DART card.
                                                 fwuHstDARTRIADCPartNumber 1.3.6.1.4.1.2014.15.2.1.1.6.1.1.1.1.11 displaystring read-only
Host DART Inventory Data - TE Part Number.
                                                 fwuHstDARTRISerialNumber 1.3.6.1.4.1.2014.15.2.1.1.6.1.1.1.1.12 displaystring read-only
Host DART Inventory Data - Serial Number.
                                                 fwuHstDARTRIDateCode 1.3.6.1.4.1.2014.15.2.1.1.6.1.1.1.1.13 displaystring read-only
Host DART Inventory Data - DateCode.
                                                 fwuHstDARTRIHWVer 1.3.6.1.4.1.2014.15.2.1.1.6.1.1.1.1.14 displaystring read-only
Host DART Inventory Data - HW version.
                                                 fwuHstDARTRowStatus 1.3.6.1.4.1.2014.15.2.1.1.6.1.1.1.1.15 rowstatus read-only
The status of this conceptual row. It may be active or inactive.
                                                 fwuHstDARTPeakInputPwrLvl1 1.3.6.1.4.1.2014.15.2.1.1.6.1.1.1.1.16 displaystring read-only
Peak Input Power Level 1 to a Host DART.
                                                 fwuHstDARTPeakInputPwrLvl2 1.3.6.1.4.1.2014.15.2.1.1.6.1.1.1.1.17 displaystring read-only
Peak Input Power Level 2 to a Host DART. Incase of diversity, this value will be NA.
                                                 fwuHstDARTPeakAvgInputPwrLvl1 1.3.6.1.4.1.2014.15.2.1.1.6.1.1.1.1.18 displaystring read-only
Peak Average Input Power Level1 to a Host DART.
                                                 fwuHstDARTPeakAvgInputPwrLvl2 1.3.6.1.4.1.2014.15.2.1.1.6.1.1.1.1.19 displaystring read-only
Peak Average Input Power Level 2 to a Host DART. Incase of diversity, this value will be NA.
                                                 fwuHstDARTMinAvgInputPwrLvl1 1.3.6.1.4.1.2014.15.2.1.1.6.1.1.1.1.20 displaystring read-only
Minimum Average Input Power Level 1 to a Host DART.
                                                 fwuHstDARTMinAvgInputPwrLvl2 1.3.6.1.4.1.2014.15.2.1.1.6.1.1.1.1.21 displaystring read-only
Minimum Average Input Power Level 2 to a Host DART. Incase of diversity, this value will be NA.
                                                 fwuHstDARTInputPowerMode 1.3.6.1.4.1.2014.15.2.1.1.6.1.1.1.1.22 integer read-write
Host DART Input Power Level Mode. The supported modes are Snapshot(0) and Max Hold(1). When setting Max Hold, ensure that the status (fwuHstDARTDiversityStatus) is not diversity. Enumeration: 'maxHold': 1, 'snapShot': 0.
                                                 fwuHstDARTPwrLevelMaxHoldReset 1.3.6.1.4.1.2014.15.2.1.1.6.1.1.1.1.23 integer read-write
Provision to reset the Max Hold reading. Used when the input power mode is Max hold. Reset by changing from normal (0) to reset (1). Status will revert to normal once the reset is done. In snapshot mode (see fwuHstDARTInputPowerMode) this object is not applicable (-1). Enumeration: 'reset': 1, 'notApplicable': -1, 'normal': 0.
                                                 fwuHstDARTLastMaxHoldResetTime 1.3.6.1.4.1.2014.15.2.1.1.6.1.1.1.1.24 octet string read-only
Date and Time of the last Max Hold reset on the host DART.
                                                 fwuHstDARTInputSrc 1.3.6.1.4.1.2014.15.2.1.1.6.1.1.1.1.25 integer read-write
To identify the input source; BTS(1) or BDA(2) and change it, if required. Enumeration: 'bda': 2, 'bts': 1.
                                 fwuHstDARTTraps 1.3.6.1.4.1.2014.15.2.1.1.6.2
                                     fwuHstDARTDwnCon1SynLockFault 1.3.6.1.4.1.2014.15.2.1.1.6.2.2
DART downconverter 1 synthesizer unlocked.
                                     fwuHstDARTDwnCon2SynLockFault 1.3.6.1.4.1.2014.15.2.1.1.6.2.3
DART downconverter 2 synthesizer unlocked.
                                     fwuHstDARTUpConSynLockFault 1.3.6.1.4.1.2014.15.2.1.1.6.2.4
DART upconverter synthesizer unlocked.
                                     fwuHstDARTOverDriveFault 1.3.6.1.4.1.2014.15.2.1.1.6.2.5
DART forward RF input too high.
                                     fwuHstDARTUnderDriveFault 1.3.6.1.4.1.2014.15.2.1.1.6.2.6
DART forward RF input signal below the normal operating limit.
                                     fwuHstDARTFault 1.3.6.1.4.1.2014.15.2.1.1.6.2.7
Summary of DART Downconverter 1 Synthesizer Unlocked, Downconverter 2 Synthesizer Unlocked, Upconverter Synthesizer Unlocked, DC Supply Fault alarms, and DART FPGA status.
                                     fwuHstDARTDCSupplyFault 1.3.6.1.4.1.2014.15.2.1.1.6.2.8
DART card DC supply voltages outside specification.
                                     fwuHstDARTHardwareMismatchFault 1.3.6.1.4.1.2014.15.2.1.1.6.2.9
Host DART does not support the selected passband. Fault occurs when a Host DART is replaced with another DART of the incorrect type.
                                     fwuHstDARTALCLimitingFault 1.3.6.1.4.1.2014.15.2.1.1.6.2.10
Host DART forward path Automatic Level Control is active.
                                     fwuHstDARTLinkingConflictFault 1.3.6.1.4.1.2014.15.2.1.1.6.2.11
Host comes back up and finds that it cannot restore a link with a remote DART to which it was linked.
                             fwuHstSystemCardObjects 1.3.6.1.4.1.2014.15.2.1.1.7
                                 fwuHstSystemCardInfo 1.3.6.1.4.1.2014.15.2.1.1.7.1
                                     fwuHstSysCardRIADCPartNumber 1.3.6.1.4.1.2014.15.2.1.1.7.1.1 displaystring read-only
Host Inventory Data - TE Part Number.
                                     fwuHstSysCardRISerialNumber 1.3.6.1.4.1.2014.15.2.1.1.7.1.2 displaystring read-only
Host Inventory Data - Serial Number.
                                     fwuHstSysCardRIDateCode 1.3.6.1.4.1.2014.15.2.1.1.7.1.3 displaystring read-only
Host Inventory Data - Date Code.
                                     fwuHstSysCardRIHWVer 1.3.6.1.4.1.2014.15.2.1.1.7.1.4 displaystring read-only
Host Inventory Data - Hardware version.
                                     fwuHstSysCard10MhzRefClock 1.3.6.1.4.1.2014.15.2.1.1.7.1.5 integer read-write
System Card Reference clock. It may be set to internal (0) or external(1). Enumeration: 'internal': 0, 'external': 1.
                                     fwuHstSysCardCPLevel 1.3.6.1.4.1.2014.15.2.1.1.7.1.6 integer32 read-write
System Card Master Clock Priority Level prioritizes the system card clock using values 1 through 14 (Lower value is higher priority). This is primarily used in multihost systems. In such system, all hosts should have different priority levels, and the system inherently assures this. This entity allows the user to change the system set prioritization. Changeing values in a single host system has no change.
                                     fwuHstSysCardOutputRefClock 1.3.6.1.4.1.2014.15.2.1.1.7.1.7 integer read-write
System Card Reference clock. System Board I supports only 10 MHz and System Board II supports both 10 MHz and 30 MHz Clock output. Default value is 1 for Host and 2 for DRU. Enumeration: 'clock30mhz': 2, 'clock10mhz': 1, 'off': 0.
                                     fwuHstSysCardRIHWGen 1.3.6.1.4.1.2014.15.2.1.1.7.1.8 integer read-only
Host System Card Hardware Generation. Presently, there are two generations; first Generation(0), second Generation(1) Enumeration: 'secondGeneration': 1, 'firstGeneration': 0.
                                 fwuHstSystemCardTraps 1.3.6.1.4.1.2014.15.2.1.1.7.2
                                     fwuHstSysCardFanFault 1.3.6.1.4.1.2014.15.2.1.1.7.2.2
Fan not functioning.
                                     fwuHstSysCardClockMismatchFault 1.3.6.1.4.1.2014.15.2.1.1.7.2.3
System Card output clock not supported.
                         fwuRemoteUnitObjects 1.3.6.1.4.1.2014.15.2.1.2
                             fwuRmtSystemLevelObjects 1.3.6.1.4.1.2014.15.2.1.2.1
                                 fwuRmtSystemLevelInfo 1.3.6.1.4.1.2014.15.2.1.2.1.1
                                     fwuRmtGeneral 1.3.6.1.4.1.2014.15.2.1.2.1.1.1
                                         fwuRmtGeneralTable 1.3.6.1.4.1.2014.15.2.1.2.1.1.1.1 no-access
This table maintains Information of remote.
                                             fwuRmtGeneralEntry 1.3.6.1.4.1.2014.15.2.1.2.1.1.1.1.1 no-access
Each entry in this table refers to remote objects.
                                                 fwuRmtNumber 1.3.6.1.4.1.2014.15.2.1.2.1.1.1.1.1.1 unitid2 read-only
The Node address of connected remote.
                                                 fwuRmtCatalogState 1.3.6.1.4.1.2014.15.2.1.2.1.1.1.1.1.2 catalogtype read-only
Catalog state of remote. If fwuRmtCatalogState is commission(2), then start commissioning on remote, else if it in normal, do not commission the remote.
                                                 fwuRmtName 1.3.6.1.4.1.2014.15.2.1.2.1.1.1.1.1.3 displaystring read-only
User defined name of the remote unit. All characters except angular brackets, single and double quotes are allowed. Minimum length of the name is 1 character. Maximum length of the name 64 characters.
                                                 fwuRmtAlarmStatusSummary 1.3.6.1.4.1.2014.15.2.1.2.1.1.1.1.1.4 alarmtype read-only
Summary of alarm status of all connected remote units.
                                                 fwuRmtTempMeasurement 1.3.6.1.4.1.2014.15.2.1.2.1.1.1.1.1.5 displaystring read-only
Temperature of each remote unit in Celsius. This value comes from the RSI.
                                                 fwuRmtGeneralTableRowStatus 1.3.6.1.4.1.2014.15.2.1.2.1.1.1.1.1.6 rowstatus read-only
The status of this conceptual row. It may be active or inactive.
                                                 fwuRmtType 1.3.6.1.4.1.2014.15.2.1.2.1.1.1.1.1.7 unittype read-only
The type of Remote. e.g. Prism, DRU, HEU, IRU.
                                                 fwuDruIfCombinerReboot 1.3.6.1.4.1.2014.15.2.1.2.1.1.1.1.1.8 unsigned32 read-write
Reboot an IF-combiner and all the units connected to it. Only applicable to DRU-IFs Change Value from 0 to 1 to reboot.
                                                 fwuUsrCommLinkTestIFBr 1.3.6.1.4.1.2014.15.2.1.2.1.1.1.1.1.9 integer read-write
Provision to perform system test on an IF branch. Change from inactive(0) to start(1) to initiate the test. For the duration of the test inprogress(2) is displayed. On completion, inactive is displayed. Enumeration: 'start': 1, 'inprogress': 2, 'inactive': 0.
                                                 fwuUsrCommLinkTestIFBrDType 1.3.6.1.4.1.2014.15.2.1.2.1.1.1.1.1.10 bandtype read-write
Selected Bands i.e. RF DARTs on units when performing system test.
                                                 fwuUsrCommLinkTestDartId 1.3.6.1.4.1.2014.15.2.1.2.1.1.1.1.1.11 unsigned32 read-write
To identify the DART .
                                                 fwuDruBackPlaneRev 1.3.6.1.4.1.2014.15.2.1.2.1.1.1.1.1.12 octet string read-only
Provides the back plane revision of the DRU (Three pin version Number of the Chassis back plane)
                                                 fwuPrismUnitReset 1.3.6.1.4.1.2014.15.2.1.2.1.1.1.1.1.13 integer read-write
Provides a way to reset the Remote SERF card. SET this to reset(1) to trigger a remote unit reset. Enumeration: 'reset': 1, 'normal': 0.
                                 fwuRmtSystemLevelTraps 1.3.6.1.4.1.2014.15.2.1.2.1.2
                                     fwuRmtAcPowerSupplyFault 1.3.6.1.4.1.2014.15.2.1.2.1.2.2
Summary of AC Power Supply 1, AC Power Supply 2, AC Power Supply 3, and AC Power Supply 4 alarms.
                                     fwuRmtMajorExtAlarmInputFault 1.3.6.1.4.1.2014.15.2.1.2.1.2.3
The remote Major Ext Alarm Input Fault.
                                     fwuRmtMinorExtAlarmInputFault 1.3.6.1.4.1.2014.15.2.1.2.1.2.4
The remote Minor Ext Alarm Input Fault.
                                     fwuRmtModuleMissingFault 1.3.6.1.4.1.2014.15.2.1.2.1.2.5
A Remote (DRU/PRU/URU) pluggable module is missing (if DRU: DART or SFP. If PRU/URU: DART, SFP, LNA, LPA, or PD).
                                     fwuRmtOverTempFault 1.3.6.1.4.1.2014.15.2.1.2.1.2.6
Remote Temperature above operating limit.
                                     fwuRmtUnderTempFault 1.3.6.1.4.1.2014.15.2.1.2.1.2.7
Temperature below operating limit.
                                     fwuRmtOpenDoorFault 1.3.6.1.4.1.2014.15.2.1.2.1.2.8
Door open on PRU.
                                     fwuRmtFanOverSpeedFault 1.3.6.1.4.1.2014.15.2.1.2.1.2.9
Fans operating above expected RPM.
                                     fwuRmtFanUnderSpeedFault 1.3.6.1.4.1.2014.15.2.1.2.1.2.10
Fans operating below expected RPM.
                                     fwuRmtDownLinkCalToneFailureFault 1.3.6.1.4.1.2014.15.2.1.2.1.2.11
Forward calibration tone not at expected level.
                                     fwuRmtUplinkFailureDetectLowFault 1.3.6.1.4.1.2014.15.2.1.2.1.2.12
Reverse test tone not at expected level.
                                     fwuRmtUpConvertFailureFault 1.3.6.1.4.1.2014.15.2.1.2.1.2.13
Band specific alarm raised during Forward Link Monitoring on PRU/URU.
                                     fwuRmtUnderPowerFault 1.3.6.1.4.1.2014.15.2.1.2.1.2.14
Band specific alarm raised during Forward Link Monitoring on PRU/URU.
                                     fwuRmtDownConvertFailureFault 1.3.6.1.4.1.2014.15.2.1.2.1.2.15
Band specific alarm raised during Reverse Link Monitoring on PRU/URU.
                                     fwuRmtUpconIndetFault 1.3.6.1.4.1.2014.15.2.1.2.1.2.16
Band specific alarm raised during Forward Link Monitoring on PRU/URU.
                                     fwuRmtFiberConnMismatchFault 1.3.6.1.4.1.2014.15.2.1.2.1.2.17
Fiber optic cable connections between cascaded DRU/PRUs not following SFP connection rules.
                                     fwuRmtExcessConnFault 1.3.6.1.4.1.2014.15.2.1.2.1.2.18
Two or more DRU/PRU/URU connected to a single cascaded DRU/PRU/URU, or a ninth DRU/PRU/URU connected in cascade.
                                     fwuRmtInvalidDevConnFault 1.3.6.1.4.1.2014.15.2.1.2.1.2.19
PRU/URU connected to a DRU or vice versa.
                                     fwuDruSysCardClockMismatchFault 1.3.6.1.4.1.2014.15.2.1.2.1.2.20
System Card output clock not supported.
                                     fwuDruNoCommsFault 1.3.6.1.4.1.2014.15.2.1.2.1.2.21
DRU has lost communication with IFEU Or IFEU is disconnected from the DRU.
                                     fwuSWVersionMismatchFault 1.3.6.1.4.1.2014.15.2.1.2.1.2.22
Software Version Mismatch Fault. SW Versions on the Host and Remote do not match.
                                     fwuDruSysCardFanFault 1.3.6.1.4.1.2014.15.2.1.2.1.2.23
Fan not functioning.
                                     fwuDruOverTempFault 1.3.6.1.4.1.2014.15.2.1.2.1.2.24
DRU Temperature above operating limit.
                                     fwuDruUnderTempFault 1.3.6.1.4.1.2014.15.2.1.2.1.2.25
DRU Temperature below operating limit.
                             fwuRmtSERFObjects 1.3.6.1.4.1.2014.15.2.1.2.2
                                 fwuRmtSERFInfo 1.3.6.1.4.1.2014.15.2.1.2.2.1
                                     fwuRmtSERFGeneral 1.3.6.1.4.1.2014.15.2.1.2.2.1.1
                                         fwuRmtSERFGeneralTable 1.3.6.1.4.1.2014.15.2.1.2.2.1.1.1 no-access
This table maintains Information of remote SERF Card.
                                             fwuRmtSERFGeneralEntry 1.3.6.1.4.1.2014.15.2.1.2.2.1.1.1.1 no-access
Each entry in this table refers to SERF Card objects.
                                                 fwuRmtSERFLinuxKernelVer 1.3.6.1.4.1.2014.15.2.1.2.2.1.1.1.1.1 displaystring read-only
Linux Kernel version on remote.
                                                 fwuRmtSERFLinuxBootLoaderVer 1.3.6.1.4.1.2014.15.2.1.2.2.1.1.1.1.2 displaystring read-only
Linux Boot loader version on remote.
                                                 fwuRmtSERFCompactFlashSWVer 1.3.6.1.4.1.2014.15.2.1.2.2.1.1.1.1.3 displaystring read-only
Compact Flash version on remote.
                                                 fwuRmtSERFFPGAVer 1.3.6.1.4.1.2014.15.2.1.2.2.1.1.1.1.4 displaystring read-only
Version of FPGA loaded on remote SeRF.
                                                 fwuRmtSERFPPCHWMonSWVer 1.3.6.1.4.1.2014.15.2.1.2.2.1.1.1.1.5 displaystring read-only
Hardware monitor process version on remote.
                                                 fwuRmtSERFPPCAPPMonSWVer 1.3.6.1.4.1.2014.15.2.1.2.2.1.1.1.1.6 displaystring read-only
Application monitor process version on remote.
                                                 fwuRmtSERFPPCMATEMonSWVer 1.3.6.1.4.1.2014.15.2.1.2.2.1.1.1.1.9 displaystring read-only
Mate monitor process version on remote.
                                                 fwuRmtSERFPPCENETMonSWVer 1.3.6.1.4.1.2014.15.2.1.2.2.1.1.1.1.10 displaystring read-only
ENET monitor process version on remote.
                                                 fwuRmtSERFPPCFPGAMonSWVer 1.3.6.1.4.1.2014.15.2.1.2.2.1.1.1.1.11 displaystring read-only
FPGA monitor process version on remote.
                                                 fwuRmtSERFRIDateCode 1.3.6.1.4.1.2014.15.2.1.2.2.1.1.1.1.12 displaystring read-only
Remote SERF Inventory - Date Code of the Remote system.
                                                 fwuRmtSERFRIHWVer 1.3.6.1.4.1.2014.15.2.1.2.2.1.1.1.1.13 displaystring read-only
Remote SERF Inventory - HardWare version of the remote system.
                                                 fwuRmtSERFRISerialNumber 1.3.6.1.4.1.2014.15.2.1.2.2.1.1.1.1.14 displaystring read-only
Remote SERF Inventory - Serial Number.
                                                 fwuRmtSERFRIADCPartNumber 1.3.6.1.4.1.2014.15.2.1.2.2.1.1.1.1.15 displaystring read-only
Remote SERF Inventory - TE PartNumber.
                                                 fwuRmtSERFRIHWGen 1.3.6.1.4.1.2014.15.2.1.2.2.1.1.1.1.16 integer read-only
Remote SERF Hardware Generation. Presently, there are two generations first generation(0), second generation(1) Enumeration: 'secondGeneration': 1, 'firstGeneration': 0.
                                                 fwuRmtpThreadSWVer 1.3.6.1.4.1.2014.15.2.1.2.2.1.1.1.1.17 displaystring read-only
The version number of pThread Process. If blank then pThread is not running.
                                                 fwuRmtWebServerSWVer 1.3.6.1.4.1.2014.15.2.1.2.2.1.1.1.1.18 displaystring read-only
The version number of Web Server on remote.
                                     fwuRmtSERFOptObjects 1.3.6.1.4.1.2014.15.2.1.2.2.1.2
                                         fwuRmtSERFOptTable 1.3.6.1.4.1.2014.15.2.1.2.2.1.2.1 no-access
This table maintains Information of remote units SFP objects.
                                             fwuRmtSERFOptEntry 1.3.6.1.4.1.2014.15.2.1.2.2.1.2.1.1 no-access
Each entry in this table refers to remote units SFP objects.
                                                 fwuRmtSERFOptSFPNumber 1.3.6.1.4.1.2014.15.2.1.2.2.1.2.1.1.1 integer32 read-only
A unique identifier of each SFP. The identifier is the SFP slot number. There are eight slots. Therefore, the valid values are 1 to 8.
                                                 fwuRmtSERFOptSFPName 1.3.6.1.4.1.2014.15.2.1.2.2.1.2.1.1.2 displaystring read-write
User defined name of each Remote SFP. All characters except angular brackets, single and double quotes are allowed. Minimum length of the name is 1 character. Maximum length of the name 64 characters.
                                                 fwuRmtSERFOptSFPType 1.3.6.1.4.1.2014.15.2.1.2.2.1.2.1.1.3 opticstype read-only
SFP Type - Optical Port Type. Identifies whether the SFP is short(1)/intermediate(2)/long(3) range. It may also be unidentified (-1).
                                                 fwuRmtSERFOptSFPColor 1.3.6.1.4.1.2014.15.2.1.2.2.1.2.1.1.4 integer32 read-only
Wavelength of light used in the SFP (in nanometers).
                                                 fwuRmtSERFOptRevLaunchPowerMeas 1.3.6.1.4.1.2014.15.2.1.2.2.1.2.1.1.5 displaystring read-only
Value of the optical power, in dBm received at the remote.
                                                 fwuRmtSERFOptFwdLaunchPowerMeas 1.3.6.1.4.1.2014.15.2.1.2.2.1.2.1.1.6 displaystring read-only
Value of the optical power, in dBm transmitted by the remote.
                                                 fwuRmtSERFOptMateName 1.3.6.1.4.1.2014.15.2.1.2.2.1.2.1.1.7 displaystring read-only
Name of Remote mate.
                                                 fwuRmtSERFIPEnable 1.3.6.1.4.1.2014.15.2.1.2.2.1.2.1.1.8 integer read-only
IP enable mode. Enumeration: 'iPDisable': 2, 'iPEnable': 1.
                                                 fwuRmtSERFOptMateId 1.3.6.1.4.1.2014.15.2.1.2.2.1.2.1.1.9 unitid2 read-only
Identifier of (companion) mate unit.
                                                 fwuRmtSERFOptMateSfpId 1.3.6.1.4.1.2014.15.2.1.2.2.1.2.1.1.10 integer32 read-only
Identifier of SFP to which the mate connects.
                                                 fwuRmtSERFOptMateSfpDir 1.3.6.1.4.1.2014.15.2.1.2.2.1.2.1.1.11 integer read-only
Indicates whether the fiber is incoming(from the direction of the host) (0) or outgoing (away from the unit)(1) on this SFP port. Enumeration: 'forwad': 1, 'reverse': 0, 'notDirection': -1.
                                                 fwuRmtSERFOptHostIP 1.3.6.1.4.1.2014.15.2.1.2.2.1.2.1.1.12 octet string read-only
IP addresses of Host. If 'NA', then it means that no host is connected.
                                 fwuRmtSERFTraps 1.3.6.1.4.1.2014.15.2.1.2.2.2
                                     fwuRmtSERFHstLostFault 1.3.6.1.4.1.2014.15.2.1.2.2.2.2
Host not communicating with DRU/PRU/URU.
                                     fwuRmtSERFOptRxBERFault 1.3.6.1.4.1.2014.15.2.1.2.2.2.3
High bit error rate (BER) detected by fiber optic receiver.
                                     fwuRmtSERFOptRxNoLightFault 1.3.6.1.4.1.2014.15.2.1.2.2.2.4
No signal detected by optical receiver.
                                     fwuRmtSERFOptLaserFault 1.3.6.1.4.1.2014.15.2.1.2.2.2.5
SFP optical transmitter failed.
                                     fwuRmtSERFOptOverDriveFault 1.3.6.1.4.1.2014.15.2.1.2.2.2.6
SFP optical receive input power above specification.
                                     fwuRmtSERFOptUnderDriveFault 1.3.6.1.4.1.2014.15.2.1.2.2.2.7
SFP optical receive input power below specification.
                                     fwuRmtSERFSynthAlarmFault 1.3.6.1.4.1.2014.15.2.1.2.2.2.8
SeRF synthesizer unlocked.
                                     fwuRmtSERFFault 1.3.6.1.4.1.2014.15.2.1.2.2.2.9
Summary of SeRF Synthesizer Unlocked alarm and SeRF FPGA status. Possibly, the system may not be communicating with the Ethernet Switch. This is also precipitated by the I2C Bus Fault.
                                     fwuRmtI2CBus1Fault 1.3.6.1.4.1.2014.15.2.1.2.2.2.10
Indicates an I2C communication problem.
                                     fwuRmtI2CBus2Fault 1.3.6.1.4.1.2014.15.2.1.2.2.2.11
Indicates an I2C communication problem.
                             fwuRmtSERFEthPortObjects 1.3.6.1.4.1.2014.15.2.1.2.3
                                 fwuRmtSERFEthPortInfo 1.3.6.1.4.1.2014.15.2.1.2.3.1
                                     fwuRmtSERFEthPortTable 1.3.6.1.4.1.2014.15.2.1.2.3.1.1 no-access
This table maintains information of Host Ethernet Ports.
                                         fwuRmtSERFEthPortEntry 1.3.6.1.4.1.2014.15.2.1.2.3.1.1.1 no-access
Each entry in this table refers to Host SERF Ethernet port objects.
                                             fwuRmtSERFEthPortNumber 1.3.6.1.4.1.2014.15.2.1.2.3.1.1.1.1 unsigned32 read-only
A unique identifier for each Ethernet port. There are twelve ports.
                                             fwuRmtSERFEthPortType 1.3.6.1.4.1.2014.15.2.1.2.3.1.1.1.2 enettype read-only
An identifier for the type of Ethernet port. The port types are network(1), craft(2) , management(3) , switch(4) , SFP(5). It may be unknown (-1).
                                             fwuRmtSERFEthPortRxBytes 1.3.6.1.4.1.2014.15.2.1.2.3.1.1.1.3 counter64 read-only
The number of bytes recieved at this ethernet port.
                                             fwuRmtSERFEthPortRxPkts 1.3.6.1.4.1.2014.15.2.1.2.3.1.1.1.4 counter64 read-only
The number of packets recieved at this ethernet port.
                                             fwuRmtSERFEthPortRxFcsErrors 1.3.6.1.4.1.2014.15.2.1.2.3.1.1.1.5 counter64 read-only
The number of FCS errors recieved at this ethernet port.
                                             fwuRmtSERFEthPortRxBroadcastPkts 1.3.6.1.4.1.2014.15.2.1.2.3.1.1.1.6 counter64 read-only
The number of broadcast packets recieved at this ethernet port.
                                             fwuRmtSERFEthPortRxMulticastPkts 1.3.6.1.4.1.2014.15.2.1.2.3.1.1.1.7 counter64 read-only
The number of multicast packets recieved at this ethernet port.
                                             fwuRmtSERFEthPortRxFragmtdFrames 1.3.6.1.4.1.2014.15.2.1.2.3.1.1.1.8 counter64 read-only
The number of fragmented frames received at this ethernet port.
                                             fwuRmtSERFEthPortRxJabbersFrames 1.3.6.1.4.1.2014.15.2.1.2.3.1.1.1.9 counter64 read-only
The number of jabber frames received at this ethernet port.
                                             fwuRmtSERFEthPortTxByteCounter 1.3.6.1.4.1.2014.15.2.1.2.3.1.1.1.10 counter64 read-only
The number of bytes transmitted from this ethernet port.
                                             fwuRmtSERFEthPortTxPkts 1.3.6.1.4.1.2014.15.2.1.2.3.1.1.1.11 counter64 read-only
The number of packets transmitted from this ethernet port.
                                             fwuRmtSERFEthPortTxBroadcastPkts 1.3.6.1.4.1.2014.15.2.1.2.3.1.1.1.12 counter64 read-only
The number of broadcast packets transmitted from this ethernet port.
                                             fwuRmtSERFEthPortTxMulticastPkts 1.3.6.1.4.1.2014.15.2.1.2.3.1.1.1.13 counter64 read-only
The number of multicast packets transmitted from this ethernet port.
                                             fwuRmtSERFEthPortSFPId 1.3.6.1.4.1.2014.15.2.1.2.3.1.1.1.14 integer32 read-only
Identifier of SFP to which this ethernet port connects to.
                                 fwuRmtSERFEthPortTraps 1.3.6.1.4.1.2014.15.2.1.2.3.2
                             fwuRmtSERFFPGAObjects 1.3.6.1.4.1.2014.15.2.1.2.4
                                 fwuRmtSERFFPGAInfo 1.3.6.1.4.1.2014.15.2.1.2.4.1
                                     fwuRmtSERFFPGAInfoTable 1.3.6.1.4.1.2014.15.2.1.2.4.1.1 no-access
This table maintains Information of remote SERF FPGA objects.
                                         fwuRmtSERFFPGAInfoEntry 1.3.6.1.4.1.2014.15.2.1.2.4.1.1.1 no-access
Each entry in this table refers to SERF FPGA information.
                                             fwuRmtSERFFPGAStatus 1.3.6.1.4.1.2014.15.2.1.2.4.1.1.1.1 integer read-only
Remote SERF Card FPGA status. Either the ppc can talk to FPGA(0) or not(1) Enumeration: 'ppcCannotTalkToFPGA': 1, 'ppcCanTalkToFPGA': 0.
                                 fwuRmtSERFFPGATraps 1.3.6.1.4.1.2014.15.2.1.2.4.2
                             fwuRmtDARTObjects 1.3.6.1.4.1.2014.15.2.1.2.6
                                 fwuRmtDARTInfo 1.3.6.1.4.1.2014.15.2.1.2.6.1
                                     fwuRmtDARTGeneral 1.3.6.1.4.1.2014.15.2.1.2.6.1.1
                                         fwuRmtDARTGeneralTable 1.3.6.1.4.1.2014.15.2.1.2.6.1.1.1 no-access
This table maintains Information of Remote DART Card.
                                             fwuRmtDARTGeneralEntry 1.3.6.1.4.1.2014.15.2.1.2.6.1.1.1.1 no-access
Each entry in this table refers to remote DART Card objects.
                                                 fwuRmtDARTNumber 1.3.6.1.4.1.2014.15.2.1.2.6.1.1.1.1.1 integer32 read-only
A unique identifier for each DART Card Object of remote. Since there are eight DART slots the valid values are 1 to 8.
                                                 fwuRmtDARTName 1.3.6.1.4.1.2014.15.2.1.2.6.1.1.1.1.2 displaystring read-only
A user defined name for each DART Card object of remote. All characters except angular brackets, single and double quotes are allowed. Minimum length of the name is 1 character. Maximum length of the name 64 characters.
                                                 fwuRmtDARTBandType 1.3.6.1.4.1.2014.15.2.1.2.6.1.1.1.1.3 bandtype read-only
Band type of remote DART card.
                                                 fwuRmtDARTPassBand 1.3.6.1.4.1.2014.15.2.1.2.6.1.1.1.1.4 octet string read-only
This is for configuration of Pass-band type for Remote DART card. Following input formats are supported for Classic and SuperDart passband configuration. 1. For Classic Darts only, User input string would be enumeration value ( i.e., 'x'), ranging from 1 to 134. See below in section 3. for valid values. 2. For SuperDarts only, a. BandType_SubBand1+SubBand2 This is applicable only for contiguous passband selection, applicable only for PCS & AWS. (e.g., 'PCS_A1+A2+A3') b. BandType_SubBand1+SubBand2:SubBand5+SubBand6 This is applicable for noncontiguous passband selection, applicable only for PCS & AWS. (e.g., 'PCS_A1+A2:C2+C1') c. BandType_StartFrequency-StartFrequency This is applicable only for contiguous passband frequency range. (e.g.,, PCS_1930-1945) d. BandType_StartFrequency1-StartFrequency1:StartFrequency2-StartFrequency2 This is applicable only for noncontiguous passband frequency ranges. (e.g., PCS_1930-1940.5:1960.7-1970.6). Where BandType is 'PCS', 'AWS', 'UMTS','EGSM900','GSM1800', 'UC700'. 3. Valid enumeration value for classic dart:- undefined ( -1 ), cellularA2A(1),cellularA(2),cellularAA1A2(3),cellularA1(4), cellularB(5),cellularB1(6),cellularBB1(7), pcsA1(8),pcsA2(9),pcsA3(10),pcsB1(11),pcsB2(12),pcsB3(13), pcsC3(14),pcsC4(15),pcsC5(16),pcsD(17),pcsE(18),pcsF(19), pcsA1A2(24),pcsA2A3(25),pcsA3D(26),pcsDB1(27),pcsB1B2(28),pcsB2B3(29), pcsB3E(30),pcsEF(31),pcsFC3(32),pcsC3C4(33),pcsC4C5(34), pcsC5G(35),pcsGawsH(36),pcsFC2(37),pcsC1G(38),pcsA(39), pcsA2A3D(40),pcsA3DB1(41),pcsDB1B2(42),pcsB(43),pcsB2B3E(44), pcsB3EF(45),pcsEFC3(46),pcsFC3C4(47),pcsC(48), pcsC4C5G(49), pcsC5GawsH(50),pcsEFC2(51),pcsC1GawsH(52), pcsAD(53),pcsA2A3DB1(54),pcsA3DB1B2(55),pcsDB(56),pcsBE(57), pcsB2B3EF(58),pcsB3EFC3(59),pcsEFC3C4(60),pcsFC(61), pcsCG(62),pcsC4C5GawsH(63),pcsB3EFC2(64), pcsADB1(65),pcsA2A3DB1B2(66),pcsA3DB(67),pcsDBE(68), pcsBEF(69),pcsB2B3EFC3(70),pcsB3EFC3C4(71),pcsEFC(72), pcsFCG(73),pcsCGawsH(74),pcsB2B3EFC2(75), pcsADB1B2(76),pcsA2A3DB(77),pcsA3DBE(78),pcsDBEF(79), pcsBEFC3(80),pcsB2B3EFC3C4(81),pcsB3EFC(82), pcsEFCG(83),pcsFCGawsH(84),pcsADB(85), pcsA2A3DBE(86),pcsA3DBEF(87),pcsDBEFC3(88), pcsBEFC3C4(89),pcsB2B3EFC(90),pcsB3EFCG(91), pcsEFCGawsH(92),smrLow(93) , smrHigh( 94), awsA(95), awsAB(96), awsABC(97), awsABCD(98), awsABCDE(99), awsB(100), awsBC(101), awsBCD(102), awsBCDE(103), awsBCDEF(104), awsC(105), awsCD(106), awsCDE(107), awsCDEF(108), awsD(109), awsDE(110), awsDEF(111), awsE(112), awsEF(113), awsF(114), smrLowWide(115), cellularA2ABA1B1(116), GSM1800Low(117), GSM1800Middle(118), GSM1800High(119), umtsLow(120), umtsMiddle(121), umtsHigh(122), cellularAB(133), apac800iDEN(134)
                                                 fwuRmtDARTOperatingMode 1.3.6.1.4.1.2014.15.2.1.2.6.1.1.1.1.5 modetype read-only
Operating mode of remote DART card. The DART may be operating normally (1) or on standby (2). The mode may be undefined (-1).
                                                 fwuRmtDARTDiversityStatus 1.3.6.1.4.1.2014.15.2.1.2.6.1.1.1.1.6 integer read-only
Diversity Status of remote DART card. Enumeration: 'diversity': 1, 'nonDiversity': 0.
                                                 fwuRmtDARTForwardGain 1.3.6.1.4.1.2014.15.2.1.2.6.1.1.1.1.7 gaintype read-only
Primary Gain in forward path of remote DART card. The range is 0-31dB with increments in steps of 1dB.
                                                 fwuRmtDARTReverseGain 1.3.6.1.4.1.2014.15.2.1.2.6.1.1.1.1.8 gaintype read-only
Primary Gain in reverse path of remote DART card.
                                                 fwuRmtDARTForwardDelay 1.3.6.1.4.1.2014.15.2.1.2.6.1.1.1.1.9 delaytype read-only
Forward delay in micro seconds on the remote DART. If the delay setting is outside the valid range of delay values then ranging fault will be raised if the Remote Dart is Linked.
                                                 fwuRmtDARTReverseDelay 1.3.6.1.4.1.2014.15.2.1.2.6.1.1.1.1.10 delaytype read-only
Reverse delay in micro seconds on the remote DART. If the delay setting is outside the valid range of delay values then ranging fault will be raised if the Remote Dart is Linked.
                                                 fwuRmtDARTTempMeas 1.3.6.1.4.1.2014.15.2.1.2.6.1.1.1.1.11 displaystring read-only
Temperature of Remote DART in degree Celsius.
                                                 fwuRmtDARTFPGAStatus 1.3.6.1.4.1.2014.15.2.1.2.6.1.1.1.1.12 integer read-only
Remote DART FPGA Status. It indicates if the SERF FPGA can talk(0) or not talk(1)to DART FPGA . Enumeration: 'serfFpgaCanTalkToDARTFpga': 0, 'serfFpgaCannotTalkToDARTFpga': 1.
                                                 fwuRmtDARTFPGAProgramVer 1.3.6.1.4.1.2014.15.2.1.2.6.1.1.1.1.13 displaystring read-only
FPGA version on the remote DART.
                                                 fwuRmtDARTRIADCPartNumber 1.3.6.1.4.1.2014.15.2.1.2.6.1.1.1.1.14 displaystring read-only
Remote DART Inventory Data - TE Part Number.
                                                 fwuRmtDARTRISerialNumber 1.3.6.1.4.1.2014.15.2.1.2.6.1.1.1.1.15 displaystring read-only
Remote DART Inventory Data - Serial Number.
                                                 fwuRmtDARTRIDateCode 1.3.6.1.4.1.2014.15.2.1.2.6.1.1.1.1.16 displaystring read-only
Remote DART Inventory Data - DateCode.
                                                 fwuRmtDARTRIHWVer 1.3.6.1.4.1.2014.15.2.1.2.6.1.1.1.1.17 displaystring read-only
Remote DART Inventory Data - HW version.
                                                 fwuRmtDARTGeneralTableRowStatus 1.3.6.1.4.1.2014.15.2.1.2.6.1.1.1.1.18 rowstatus read-only
The status of this conceptual row.
                                                 fwuRmtDARTActualForwardDelay 1.3.6.1.4.1.2014.15.2.1.2.6.1.1.1.1.19 integer32 read-only
This is the forward delay on Remote DART.
                                                 fwuRmtDARTForwardLowerboundDelay 1.3.6.1.4.1.2014.15.2.1.2.6.1.1.1.1.20 integer32 read-only
This is the lower bound of the Forward Delay values.
                                                 fwuRmtDARTForwardUpperboundDelay 1.3.6.1.4.1.2014.15.2.1.2.6.1.1.1.1.21 integer32 read-only
This is the upper bound of the Forward Delay values.
                                                 fwuRmtDARTActualReverseDelay 1.3.6.1.4.1.2014.15.2.1.2.6.1.1.1.1.22 integer32 read-only
This is the Reverse delay on Remote DART.
                                                 fwuRmtDARTReverseLowerboundDelay 1.3.6.1.4.1.2014.15.2.1.2.6.1.1.1.1.23 integer32 read-only
This is the lower bound of the Reverse delay values.
                                                 fwuRmtDARTReverseUpperboundDelay 1.3.6.1.4.1.2014.15.2.1.2.6.1.1.1.1.24 integer32 read-only
This is the upper bound of the Reverse delay values.
                                                 fwuRmtDARTPeakInputPwrLvl1 1.3.6.1.4.1.2014.15.2.1.2.6.1.1.1.1.25 displaystring read-only
Peak Input Power Level 1 to a Remote DART.
                                                 fwuRmtDARTPeakInputPwrLvl2 1.3.6.1.4.1.2014.15.2.1.2.6.1.1.1.1.26 displaystring read-only
Peak Input Power Level 2 to the Remote DART.
                                                 fwuRmtDARTPeakAvgInputPwrLvl1 1.3.6.1.4.1.2014.15.2.1.2.6.1.1.1.1.27 displaystring read-only
Peak Average Input Power Level 1 to the Remote DART.
                                                 fwuRmtDARTPeakAvgInputPwrLvl2 1.3.6.1.4.1.2014.15.2.1.2.6.1.1.1.1.28 displaystring read-only
Peak Average Input Power Level 2 to the Remote DART.
                                                 fwuRmtDARTMinAvgInputPwrLvl1 1.3.6.1.4.1.2014.15.2.1.2.6.1.1.1.1.29 displaystring read-only
Minimum Average Input Power Level 1 to the Remote DART.
                                                 fwuRmtDARTMinAvgInputPwrLvl2 1.3.6.1.4.1.2014.15.2.1.2.6.1.1.1.1.30 displaystring read-only
Minimum Average Input Power Level 2 to the Remote DART.
                                                 fwuRmtDARTInputPowerMode 1.3.6.1.4.1.2014.15.2.1.2.6.1.1.1.1.31 integer read-write
Remote DART Input Power Level Mode. Two modes are supported Snapshot(0) and Max Hold(1). Enumeration: 'maxHold': 1, 'snapShot': 0.
                                                 fwuRmtDARTPwrLevelMaxHoldReset 1.3.6.1.4.1.2014.15.2.1.2.6.1.1.1.1.32 integer read-write
Provision to reset the Max Hold reading. Used when the input power mode is Max hold. Reset by changing from normal (0) to reset (1). Status will revert to normal once the reset is done. In snapshot mode (see fwuRmtDARTInputPowerMode) this object is not applicable (-1). Enumeration: 'reset': 1, 'notApplicable': -1, 'normal': 0.
                                                 fwuRmtDARTLastMaxHoldResetTime 1.3.6.1.4.1.2014.15.2.1.2.6.1.1.1.1.33 octet string read-only
Date and Time of the last maxHold reset on the remote DART.
                                                 fwuRmtDARTReverseGainMode 1.3.6.1.4.1.2014.15.2.1.2.6.1.1.1.1.34 integer read-write
The gain modes on the Reverse Path. Two modes are supported, Normal(0) and High(1). It is applicable to all RF modules but not to IF DARTs. Enumeration: 'high': 1, 'normal': 0.
                                                 fwuRmtDARTTxRIADCPartNumber 1.3.6.1.4.1.2014.15.2.1.2.6.1.1.1.1.35 displaystring read-only
Remote Inventory Data - TE Part Number [Tx Board]. Field will have value only if Tx Board is present.
                                                 fwuRmtDARTTxRISerialNumber 1.3.6.1.4.1.2014.15.2.1.2.6.1.1.1.1.36 displaystring read-only
Remote Inventory Data - Serial Number [Tx Board]. Field will have value only if Tx Board is present.
                                                 fwuRmtDARTTxRIDateCode 1.3.6.1.4.1.2014.15.2.1.2.6.1.1.1.1.37 displaystring read-only
Remote Inventory Data - DateCode [Tx Board]. Field will have value only if Tx Board is present.
                                                 fwuRmtDARTTxRIHWVer 1.3.6.1.4.1.2014.15.2.1.2.6.1.1.1.1.38 displaystring read-only
Remote Inventory Data - HW version [Tx Board]. Field will have value only if Tx Board is present.
                                                 fwuRmtDARTLinkedStatus 1.3.6.1.4.1.2014.15.2.1.2.6.1.1.1.1.39 integer read-only
Indicates if the DART is linked (1) or not (0). Enumeration: 'notLinked': 0, 'linked': 1.
                                                 fwuRmtDARTAvailable 1.3.6.1.4.1.2014.15.2.1.2.6.1.1.1.1.40 integer read-only
Indicates if the DART is available for use (1) or not (0). Enumeration: 'notAvailable': 0, 'available': 1.
                                                 fwuRmtDARTUsedSFP 1.3.6.1.4.1.2014.15.2.1.2.6.1.1.1.1.41 integer read-only
Indicates the SFP (number) used by a DART to link. There are eight possible SFP numbers. Therefore, the valid values are 1 to 8.
                                 fwuRmtDARTTraps 1.3.6.1.4.1.2014.15.2.1.2.6.2
                                     fwuRmtDARTDwnCon1SynLockFault 1.3.6.1.4.1.2014.15.2.1.2.6.2.2
Lock state of the first down converter synthesizer.
                                     fwuRmtDARTDwnCon2SynLockFault 1.3.6.1.4.1.2014.15.2.1.2.6.2.3
DART downconverter 2 synthesizer unlocked.
                                     fwuRmtDARTUpConSynLockFault 1.3.6.1.4.1.2014.15.2.1.2.6.2.4
DART downconverter 2 synthesizer unlocked.
                                     fwuRmtDARTDCSupplyFault 1.3.6.1.4.1.2014.15.2.1.2.6.2.5
DART card DC supply voltages outside specification.
                                     fwuRmtDARTFault 1.3.6.1.4.1.2014.15.2.1.2.6.2.6
Summary of DART Downconverter 1 Synthesizer Unlocked, Downconverter 2 Synthesizer Unlocked, Upconverter Synthesizer Unlocked, DC Supply Fault alarms, and DART FPGA status.
                                     fwuRmtDARTHardwareMismatchFault 1.3.6.1.4.1.2014.15.2.1.2.6.2.7
Remote DART does not support the selected passband. Fault occurs when a Remote DART is replaced with another DART of the incorrect type.
                                     fwuRmtRangingFault 1.3.6.1.4.1.2014.15.2.1.2.6.2.8
DRU/PRU/URU delay settings outside the valid range.
                                     fwuRmtDARTOverTempFault 1.3.6.1.4.1.2014.15.2.1.2.6.2.9
Remote DART temperature above operating limit.
                                     fwuRmtDARTLowTempFault 1.3.6.1.4.1.2014.15.2.1.2.6.2.10
Remote DART temperature below operating limit.
                                     fwuRmtDARTUplinkInactivityFault 1.3.6.1.4.1.2014.15.2.1.2.6.2.11
No uplink activity is detected for one hour.
                                     fwuRmtDARTCommsFault 1.3.6.1.4.1.2014.15.2.1.2.6.2.12
The Remote DART communication path is missing or incorrect.
                             fwuRmtLPAObjects 1.3.6.1.4.1.2014.15.2.1.2.8
                                 fwuRmtLPAInfo 1.3.6.1.4.1.2014.15.2.1.2.8.1
                                     fwuRmtLPAInfoTable 1.3.6.1.4.1.2014.15.2.1.2.8.1.1 no-access
This table maintains Information of remote LPA objects.
                                         fwuRmtLPAInfoEntry 1.3.6.1.4.1.2014.15.2.1.2.8.1.1.1 no-access
Each entry in this table refers to LPA objects.
                                             fwuRmtLPANumber 1.3.6.1.4.1.2014.15.2.1.2.8.1.1.1.1 integer32 read-only
A unique identifier for an LPA.
                                             fwuRmtLPAReset 1.3.6.1.4.1.2014.15.2.1.2.8.1.1.1.2 integer read-write
Provision to reset the LPA. Change from normal(0) to reset(1) to perform a reset of the LPA. Resetting the LPA when it is offline will place in an operating state. Enumeration: 'reset': 1, 'normal': 0.
                                             fwuRmtLPAOpState 1.3.6.1.4.1.2014.15.2.1.2.8.1.1.1.3 integer read-only
Identifies the LPA Operating mode. The modes are operating (0) and offline (1). The operating state is controlled by fwuRmtLPAControl. Also, see fwuRmtLPAReset. Enumeration: 'offline': 1, 'operating': 0.
                                             fwuRmtLPAPartNum 1.3.6.1.4.1.2014.15.2.1.2.8.1.1.1.4 displaystring read-only
Remote LPA Part Number.
                                             fwuRmtLPASerialNum 1.3.6.1.4.1.2014.15.2.1.2.8.1.1.1.5 displaystring read-only
Remote LPA Serial Number.
                                             fwuRmtLPAHWVer 1.3.6.1.4.1.2014.15.2.1.2.8.1.1.1.6 displaystring read-only
Remote LPA Hardware version.
                                             fwuRmtLPASWVer 1.3.6.1.4.1.2014.15.2.1.2.8.1.1.1.7 displaystring read-only
Remote LPA Software version.
                                             fwuRmtLPADescr 1.3.6.1.4.1.2014.15.2.1.2.8.1.1.1.8 displaystring read-only
Remote LPA Description.
                                             fwuRmtLPAControl 1.3.6.1.4.1.2014.15.2.1.2.8.1.1.1.9 integer read-write
Provision to control the operating mode of remote LPA. When the control is set to normal (0), the operating mode is operating. When the control is set to offline (1), the operating mode is standby. fwuRmtLPAOpState will reflect the change in state/mode when the values are changed for this entity. Enumeration: 'standby': 1, 'normal': 0.
                                             fwuRmtLPAMaxOpPwr 1.3.6.1.4.1.2014.15.2.1.2.8.1.1.1.10 displaystring read-only
Maximum Output power for the LPA. This object is applicable for HDMs also.
                                             fwuRmtLPABandType 1.3.6.1.4.1.2014.15.2.1.2.8.1.1.1.11 duplexertype read-only
LPA hardware type. Valid LPA Types are cellularA(1), cellularB(2), smrLow(3), smrHigh(4), pcs(5), aws(6), smrLowWide(7), fullCellular(8), gsm1800(9), umts(10), egsm900(11), lowerABC(12), upperC700(13), apac800iDEN(14), prismSmr800and900(15), prismSmr900and800(16), prismSmr800(17), cellularApac(18), apacEgsm900(19), pGsmEgsm900(20)
                                 fwuRmtLPATraps 1.3.6.1.4.1.2014.15.2.1.2.8.2
                                     fwuRmtLPADisableFault 1.3.6.1.4.1.2014.15.2.1.2.8.2.2
PRU/URU Linear Power Amplifier (LPA) disabled due to an internally detected problem. (VSWR, DC, Loop Fault, Low Power, or Temperature High alarm).
                                     fwuRmtLPAOverPowerFault 1.3.6.1.4.1.2014.15.2.1.2.8.2.3
PRU/URU Linear Power Amplifier (LPA) output power level above operating limit.
                                     fwuRmtLPAHighTempFault 1.3.6.1.4.1.2014.15.2.1.2.8.2.4
LPA High Temperature Fault.
                                     fwuRmtLPAVswrFault 1.3.6.1.4.1.2014.15.2.1.2.8.2.5
PRU/URU Linear Power Amplifier (LPA) VSWR fault.
                                     fwuRmtLPADcFault 1.3.6.1.4.1.2014.15.2.1.2.8.2.6
PRU/URU Linear Power Amplifier (LPA) DC fault.
                                     fwuRmtLPALoopFault 1.3.6.1.4.1.2014.15.2.1.2.8.2.7
PRU/URU Linear Power Amplifier (LPA) Loop fault.
                                     fwuRmtLPALowPowerFault 1.3.6.1.4.1.2014.15.2.1.2.8.2.8
Internal low power fault state of linear power amplifier (the gain of one or more internal amplifiers does not meet specification).
                                     fwuRmtLPADetectFault 1.3.6.1.4.1.2014.15.2.1.2.8.2.9
Linear Power Amplifier (LPA) detection fault. LPA missing from remote.
                                     fwuRmtPaOverCurrentFault 1.3.6.1.4.1.2014.15.2.1.2.8.2.10
PA reported fault.
                             fwuRmtPwrDetectorBoardObjects 1.3.6.1.4.1.2014.15.2.1.2.9
                                 fwuRmtPwrDetectorBoardInfo 1.3.6.1.4.1.2014.15.2.1.2.9.1
                                     fwuRmtPwrDetectorBoardInfoTable 1.3.6.1.4.1.2014.15.2.1.2.9.1.1 no-access
This table maintains Information of remote power detector board objects.
                                         fwuRmtPwrDetectorBoardInfoEntry 1.3.6.1.4.1.2014.15.2.1.2.9.1.1.1 no-access
Each entry in this table refers to power detector board objects.
                                             fwuRmtPowerDetectorNumber 1.3.6.1.4.1.2014.15.2.1.2.9.1.1.1.1 integer32 read-only
A unique identifier for each power detector.
                                             fwuRmtSystemVswrMeas 1.3.6.1.4.1.2014.15.2.1.2.9.1.1.1.2 displaystring read-only
VSWR (Voltage Standing Wave Ratio) measured in the system.
                                             fwuRmtRFPowerOutputMeas 1.3.6.1.4.1.2014.15.2.1.2.9.1.1.1.3 displaystring read-only
The value of Remote RF Power Output, in dBm.
                                             fwuRmtPwrDetectorBoardRIADCPartNum 1.3.6.1.4.1.2014.15.2.1.2.9.1.1.1.4 displaystring read-only
Power Detector Inventory - TE Part Number.
                                             fwuRmtPwrDetectorBoardRISerialNum 1.3.6.1.4.1.2014.15.2.1.2.9.1.1.1.5 displaystring read-only
Power Detector Inventory - Serial Number.
                                             fwuRmtPwrDetectorBoardRIDateCode 1.3.6.1.4.1.2014.15.2.1.2.9.1.1.1.6 displaystring read-only
Power Detector Inventory - Date Code.
                                             fwuRmtPwrDetectorBoardRIHWVer 1.3.6.1.4.1.2014.15.2.1.2.9.1.1.1.7 displaystring read-only
Power Detector Inventory - HW version.
                                             fwuRmtPwrDetectorNoRfPowerThershold 1.3.6.1.4.1.2014.15.2.1.2.9.1.1.1.8 displaystring read-write
Threshold value for RF No Power. The minimum threshold value is 0dBm and maximum threshold value is 100dBm.
                                             fwuRmtSystemVSWRThreshold 1.3.6.1.4.1.2014.15.2.1.2.9.1.1.1.9 displaystring read-write
User set VSWR threshold value. User is to provide the VSWR value in the form x.y:1. If the value is provided as x:1 then it will be represented as x.0:1. The minimum threshold value is 2.0 and maximum threshold value is 9.0.
                                 fwuRmtPwrDetectorBoardTraps 1.3.6.1.4.1.2014.15.2.1.2.9.2
                                     fwuRmtSystemVswrFault 1.3.6.1.4.1.2014.15.2.1.2.9.2.2
PRU/URU VSWR measurement above specification.
                                     fwuRmtRFPowerFault 1.3.6.1.4.1.2014.15.2.1.2.9.2.3
PRU/URU RF Output Power below minimum threshold.
                             fwuRmtLNAObjects 1.3.6.1.4.1.2014.15.2.1.2.10
                                   fwuRmtLNAInfo 1.3.6.1.4.1.2014.15.2.1.2.10.1
                                       fwuRmtLNAInfoTable 1.3.6.1.4.1.2014.15.2.1.2.10.1.1 no-access
This table maintains Information of remote LNA objects.
                                           fwuRmtLNAInfoEntry 1.3.6.1.4.1.2014.15.2.1.2.10.1.1.1 no-access
Each entry in this table refers to LNA information.
                                               fwuRmtLNANumber 1.3.6.1.4.1.2014.15.2.1.2.10.1.1.1.1 integer32 read-only
A unique identifier for LNA Objects.
                                               fwuRmtLNAType 1.3.6.1.4.1.2014.15.2.1.2.10.1.1.1.2 lnatype read-only
Remote LNA card type. Valid LNA types are Cellular A(1), Cellular B(2), SMR Low(3), SMR High(4), PCS(5), AWS(6), SMR Low Wide(7), Full Cellular(8), GSM1800(9), UMTS(10), EGSM900(11), Lower ABC 700(12), Upper C 700(13), APAC 800 iDEN(14), Prism SMR 800 and 900(15), Prism SMR 900 and 800(16), Prism SMR 800(17).
                                               fwuRmtLNARIADCPartNumber 1.3.6.1.4.1.2014.15.2.1.2.10.1.1.1.3 displaystring read-only
LNA Inventory Data - TE Part Number.
                                               fwuRmtLNARISerialNumber 1.3.6.1.4.1.2014.15.2.1.2.10.1.1.1.4 displaystring read-only
LNA Inventory Data - Serial Number.
                                               fwuRmtLNARIDateCode 1.3.6.1.4.1.2014.15.2.1.2.10.1.1.1.5 displaystring read-only
LNA Inventory Data - Date Code.
                                               fwuRmtLNARIHWVer 1.3.6.1.4.1.2014.15.2.1.2.10.1.1.1.6 displaystring read-only
LNA Inventory Data - HW version.
                                               fwuRmtDuplexerType 1.3.6.1.4.1.2014.15.2.1.2.10.1.1.1.7 duplexertype read-only
Duplexer hardware type. Valid Duplexer Types are cellularA(1), cellularB(2), smrLow(3), smrHigh(4), pcs(5), aws(6), smrLowWide(7), fullCellular(8), gsm1800(9), umts(10), egsm900(11), lowerABC(12), upperC700(13), apac800iDEN(14), prismSmr800and900(15), prismSmr900and800(16), prismSmr800(17), cellularApac(18), apacEgsm900(19), pGsmEgsm900(20)
                                   fwuRmtLNATraps 1.3.6.1.4.1.2014.15.2.1.2.10.2
                                       fwuRmtLNAPowerFault 1.3.6.1.4.1.2014.15.2.1.2.10.2.2
PRU/URU Low Noise Amplifier (LNA) Power fault.
                                       fwuRmtDuplexerFreqMismatchFault 1.3.6.1.4.1.2014.15.2.1.2.10.2.3
Configured frequency range not supported by Duplexer.
                             fwuRmtRDIObjects 1.3.6.1.4.1.2014.15.2.1.2.11
                                   fwuRmtRDIInfo 1.3.6.1.4.1.2014.15.2.1.2.11.1
                                       fwuRmtRDIInfoTable 1.3.6.1.4.1.2014.15.2.1.2.11.1.1 no-access
This table maintains Information of remote RDI objects.
                                           fwuRmtRDIInfoEntry 1.3.6.1.4.1.2014.15.2.1.2.11.1.1.1 no-access
Each entry in this table refers to RDI information.
                                               fwuRmtRDINumber 1.3.6.1.4.1.2014.15.2.1.2.11.1.1.1.1 integer32 read-only
A unique identifier for each RDI.
                                               fwuRmtRDIRIADCPartNumber 1.3.6.1.4.1.2014.15.2.1.2.11.1.1.1.2 displaystring read-only
RDI Inventory Data - TE Part Number.
                                               fwuRmtRDIRISerialNumber 1.3.6.1.4.1.2014.15.2.1.2.11.1.1.1.3 displaystring read-only
RDI Inventory Data - Serial Number.
                                               fwuRmtRDIRIDateCode 1.3.6.1.4.1.2014.15.2.1.2.11.1.1.1.4 displaystring read-only
RDI Inventory Data - Date Code.
                                               fwuRmtRDIRIHWVer 1.3.6.1.4.1.2014.15.2.1.2.11.1.1.1.5 displaystring read-only
RDI Inventory Data - HW version.
                                               fwuRmtRDIRIHWType 1.3.6.1.4.1.2014.15.2.1.2.11.1.1.1.6 integer read-only
Identifies if RDI(1) or ALPACA(2) board. It may be unknown(0). Enumeration: 'unknown': 0, 'rdi': 1, 'alpaca': 2.
                                   fwuRmtRDITraps 1.3.6.1.4.1.2014.15.2.1.2.11.2
                                       fwuRmtACPowerSupplyMon1Fault 1.3.6.1.4.1.2014.15.2.1.2.11.2.1
AC Power monitor 1 Fault.
                                       fwuRmtACPowerSupplyMon2Fault 1.3.6.1.4.1.2014.15.2.1.2.11.2.2
AC Power monitor 2 Fault.
                                       fwuRmtACPowerSupplyMon3Fault 1.3.6.1.4.1.2014.15.2.1.2.11.2.3
AC Power monitor 3 Fault.
                             fwuRmtRSIObjects 1.3.6.1.4.1.2014.15.2.1.2.12
                                   fwuRmtRSIInfo 1.3.6.1.4.1.2014.15.2.1.2.12.1
                                       fwuRmtRSIInfoTable 1.3.6.1.4.1.2014.15.2.1.2.12.1.1 no-access
This table maintains Information of Remote RSI objects.
                                           fwuRmtRSIInfoEntry 1.3.6.1.4.1.2014.15.2.1.2.12.1.1.1 no-access
Each entry in this table refers to RSI information.
                                               fwuRmtRSIRIADCPartNumber 1.3.6.1.4.1.2014.15.2.1.2.12.1.1.1.1 displaystring read-only
Remote Inventory Data - TE Part Number.
                                               fwuRmtRSIRISerialNumber 1.3.6.1.4.1.2014.15.2.1.2.12.1.1.1.2 displaystring read-only
Remote Inventory Data - Serial Number.
                                               fwuRmtRSIRIDateCode 1.3.6.1.4.1.2014.15.2.1.2.12.1.1.1.3 displaystring read-only
Remote Inventory Data - Date Code.
                                               fwuRmtRSIRIHWVer 1.3.6.1.4.1.2014.15.2.1.2.12.1.1.1.4 displaystring read-only
Remote Inventory Data - Hardware version.
                                               fwuRmtCapacity 1.3.6.1.4.1.2014.15.2.1.2.12.1.1.1.5 unsigned32 read-only
The number of RF modules that can be installed in the remote.
                                   fwuRmtRSITraps 1.3.6.1.4.1.2014.15.2.1.2.12.2
                                       fwuRmtACPowerSupplyMon4Fault 1.3.6.1.4.1.2014.15.2.1.2.12.2.1
AC Power monitor 4 Fault.
                         fwuGeneralObjects 1.3.6.1.4.1.2014.15.2.1.3
                             fwuNotifObjects 1.3.6.1.4.1.2014.15.2.1.3.1
                                 fwuTrapSequenceNumber 1.3.6.1.4.1.2014.15.2.1.3.1.1 counter32 no-access
Count of the total number of traps (including this trap), raised by the agent.
                                 fwuTrapTimeStamp 1.3.6.1.4.1.2014.15.2.1.3.1.2 dateandtime no-access
The trap time stamp.
                                 fwuNotificationStatus 1.3.6.1.4.1.2014.15.2.1.3.1.3 alarmtype no-access
The severity of the fault.
                                 fwuModuleType 1.3.6.1.4.1.2014.15.2.1.3.1.4 moduletype no-access
The module type reporting alarm.
                                 fwuModuleNumber 1.3.6.1.4.1.2014.15.2.1.3.1.5 integer32 no-access
The numerical Id of module, for the above module type, reporting the alarm.
                                 fwuTrapCode 1.3.6.1.4.1.2014.15.2.1.3.1.6 integer no-access
The unique ID of the trap.
                                 fwuTrapNodeAddress 1.3.6.1.4.1.2014.15.2.1.3.1.7 integer32 no-access
Unit from which the trap originated.
                                 fwuAlarmedModuleName 1.3.6.1.4.1.2014.15.2.1.3.1.8 displaystring no-access
Name of the hardware module where the trap originated.
                             fwuDARTMappingObjects 1.3.6.1.4.1.2014.15.2.1.3.2
                                 fwuDARTMappingInfo 1.3.6.1.4.1.2014.15.2.1.3.2.1
                                     fwuDARTMappingTable 1.3.6.1.4.1.2014.15.2.1.3.2.1.1 no-access
This table maintains Information of DART Mapping Objects.
                                         fwuDARTMappingEntry 1.3.6.1.4.1.2014.15.2.1.3.2.1.1.1 no-access
Each entry in this table refers to DART Mapping Objects.
                                             fwuDARTMappingIndex 1.3.6.1.4.1.2014.15.2.1.3.2.1.1.1.1 unsigned32 read-only
DART Mapping Table Index.
                                             fwuUnitID 1.3.6.1.4.1.2014.15.2.1.3.2.1.1.1.2 unitid2 read-only
Identifier for the unit.
                                             fwuUnitDARTID 1.3.6.1.4.1.2014.15.2.1.3.2.1.1.1.3 integer32 read-only
Identifier of DART on the unit. Since there is a maximum of 8 DARTs, the valid values are one to eight.
                                             fwuUnitSFPID 1.3.6.1.4.1.2014.15.2.1.3.2.1.1.1.4 integer32 read-only
Identifier of unit SFP connected to the mate DART (outgoing; away from the Host). Since there is a maximum of 8 SFPs, the valid values are one to eight.
                                             fwuUnitDartPassBand 1.3.6.1.4.1.2014.15.2.1.3.2.1.1.1.5 octet string read-only
Band-Passband information of the linked DART on the host side.
                                             fwuMateID 1.3.6.1.4.1.2014.15.2.1.3.2.1.1.1.6 unitid2 read-only
Identifier of (companion) mate unit.
                                             fwuMateDARTID 1.3.6.1.4.1.2014.15.2.1.3.2.1.1.1.7 integer32 read-only
Identifies the (companion) DART on mate unit. Since there is a maximum of 8 DARTs, the valid values are one to eight.
                                             fwuMateSFPID 1.3.6.1.4.1.2014.15.2.1.3.2.1.1.1.8 integer32 read-only
Identifies the remote SFP connected to the unit DART(incoming from direction of the Host).
                                             fwuMateDartPassband 1.3.6.1.4.1.2014.15.2.1.3.2.1.1.1.9 octet string read-only
Band-Passband information of the linked DART on the Mate side.
                                             fwuSFPStartTimeSlot 1.3.6.1.4.1.2014.15.2.1.3.2.1.1.1.10 integer32 read-only
Value of the first time slot used on the fiber carrying RF from unit DART to mate DART. Though this is a read-write object, the end user can only read the value. This and the next object are pair of values for a fiber. Depending on the DART type there may be a maximum of six or twelve time slots.
                                             fwuSFPEndTimeSlot 1.3.6.1.4.1.2014.15.2.1.3.2.1.1.1.11 integer32 read-only
Value of the last time slot used on the fiber carrying RF from unit DART to mate DART. Though this is a read-write object, the end user can only read the value. This and the previous object are pair of values for a fiber.
                                             fwuMappingStatus 1.3.6.1.4.1.2014.15.2.1.3.2.1.1.1.12 rowstatus read-only
The status of the conceptual row. The status may be active or inactive.
                             fwuSystemAlarmManagement 1.3.6.1.4.1.2014.15.2.1.3.3
                                 fwuSystemAlarmManagementTable 1.3.6.1.4.1.2014.15.2.1.3.3.1 no-access
This table maintains alarm managing property and threshold information of all alarms.
                                     fwuSystemAlarmManagementEntry 1.3.6.1.4.1.2014.15.2.1.3.3.1.1 no-access
Each entry in this table refers to Alarm management table Objects.
                                         fwuSystemAlarmcode 1.3.6.1.4.1.2014.15.2.1.3.3.1.1.1 unsigned32 read-only
The alarm code.It is used as Table Index.
                                         fwuSystemAlarmManageable 1.3.6.1.4.1.2014.15.2.1.3.3.1.1.2 alarmmanage read-only
Indicates if the alarm is manageble(0) or not (1). If manageable, use fwuSystemAlarmEnabled, see below, to enable or disable the alarm.
                                         fwuSystemAlarmThreshold 1.3.6.1.4.1.2014.15.2.1.3.3.1.1.3 displaystring read-only
Alarm Threshold value.
                                         fwuSystemAlarmModType 1.3.6.1.4.1.2014.15.2.1.3.3.1.1.4 integer32 read-only
Identifies the module type which raised the alarm.
                                 fwuSystemModuleAlarmEnableTable 1.3.6.1.4.1.2014.15.2.1.3.3.2 no-access
This table will allow the user to enable or disable an alarm. Use the fwuSystemAlarmManagementTable to check if the alarm is manageable or not.
                                     fwuSystemModuleAlarmEnableEntry 1.3.6.1.4.1.2014.15.2.1.3.3.2.1 no-access
Each entry in this table refers to Module alarm enable table Objects.
                                         fwuSystemTrapNodeAddress 1.3.6.1.4.1.2014.15.2.1.3.3.2.1.1 unsigned32 read-write
The unit which raised the alarm.
                                         fwuSystemAlarmModuleNo 1.3.6.1.4.1.2014.15.2.1.3.3.2.1.2 unsigned32 read-write
The module which raised the alarm.
                                         fwuSystemModuleAlarmcode 1.3.6.1.4.1.2014.15.2.1.3.3.2.1.3 unsigned32 read-write
The alarm code.
                                         fwuSystemAlarmEnabled 1.3.6.1.4.1.2014.15.2.1.3.3.2.1.4 alarmenable read-write
This is used to enable or disable the alarm. Alarms is enabled by default, except the Uplink inactivity fault.
                             fwuGeoObjects 1.3.6.1.4.1.2014.15.2.1.3.4
                                 fwuGeoTable 1.3.6.1.4.1.2014.15.2.1.3.4.2 no-access
This table maintains Information of Geo Objects.
                                     fwuGeoEntry 1.3.6.1.4.1.2014.15.2.1.3.4.2.1 no-access
Each entry in this table refers to Geo Objects.
                                         fwuGeoIndex 1.3.6.1.4.1.2014.15.2.1.3.4.2.1.1 unsigned32 read-write
Geo objects Table Index.
                                         fwuGeoLatitude 1.3.6.1.4.1.2014.15.2.1.3.4.2.1.2 displaystring read-write
Identifies the Latitude of remote unit.
                                         fwuGeoLongitude 1.3.6.1.4.1.2014.15.2.1.3.4.2.1.3 displaystring read-write
Identifies the Longitude of remote unit.
                                         fwuGeoRmtName 1.3.6.1.4.1.2014.15.2.1.3.4.2.1.4 displaystring read-only
The Remote name.
                                         fwuGeoStatus 1.3.6.1.4.1.2014.15.2.1.3.4.2.1.5 integer read-only
Standard SNMP row status for this table. Enumeration: 'active': 1, 'notPresent': 0, 'inActive': 2.
                             fwuSnmpSettings 1.3.6.1.4.1.2014.15.2.1.3.5
                                 fwuV1TrapAgentAddrOverrideMode 1.3.6.1.4.1.2014.15.2.1.3.5.1 integer read-write
Provision to overide the default (1) or use default (0) agent address in v1 trap PDU. Use fwuV1TrapAgentAddrOverrideIPAddr to set the overriding agent address. Enumeration: 'enable': 1, 'disable': 0.
                                 fwuV1TrapAgentAddrOverrideIPAddr 1.3.6.1.4.1.2014.15.2.1.3.5.2 octet string read-write
The overriding agent IP address in v1 trap PDU. Use Internet standard dot-decimal notation. Enable its use by setting fwuV1TrapAgentAddrOverrideMode.
                                 fwuSnmpTrapResendInterval 1.3.6.1.4.1.2014.15.2.1.3.5.3 integer32 read-write
Time, in seconds, to resend unacknowledged traps. The trap will not be resent if this is set to zero(0). Acknowledgement is not needed if resend is not required, therefore, no trap entry will be entered into fwuSystemActiveAlarmTable.
                                 fwuSnmpTrapResendMaximum 1.3.6.1.4.1.2014.15.2.1.3.5.4 integer32 read-write
Maximum number of times traps will be resent before removal if not acknowledged. If set to zero, it will not be resent.
                                 fwuSnmpTrapMgrConfigTable 1.3.6.1.4.1.2014.15.2.1.3.5.7 no-access
Table containing information about the trap destinations. For changes to take effect, a (Host) reboot is required.
                                     fwuSnmpTrapMgrConfigEntry 1.3.6.1.4.1.2014.15.2.1.3.5.7.1 no-access
An entry in the fwuSnmpTrapMgrConfigTable.
                                         fwuTrapMgrRowId 1.3.6.1.4.1.2014.15.2.1.3.5.7.1.1 integer no-access
The unique index of this trap destination.
                                         fwuTrapMgrIpAddress 1.3.6.1.4.1.2014.15.2.1.3.5.7.1.2 octet string read-only
Provision to set the IP address of the trap manager. Use Internet standard dot-decimal notation.
                                         fwuTrapMgrListeningPort 1.3.6.1.4.1.2014.15.2.1.3.5.7.1.3 unsigned32 read-only
Provision to set the port at which the trap manager is listening for the traps. The default port for SNMP traps is 162.
                                         fwuTrapMgrCommunity 1.3.6.1.4.1.2014.15.2.1.3.5.7.1.4 displaystring read-only
The community used by the agent to send traps or informs to this manager.
                                         fwuTrapVersion 1.3.6.1.4.1.2014.15.2.1.3.5.7.1.5 integer read-only
The SNMP version used for this trap destination. The available versions are v1(0), v2c(1), inform(2) with v2c being set as default. Enumeration: 'v2c': 1, 'v1': 0, 'inform': 2.
                                         fwuTrapMgrRowStatus 1.3.6.1.4.1.2014.15.2.1.3.5.7.1.6 rowstatus read-only
The status of this conceptual row. This is used to manage the creation and deletion of this trap destination table.
                                 fwuEnableNotifHysteresis 1.3.6.1.4.1.2014.15.2.1.3.5.8 integer read-write
Provision to enable(1) or disable(0) event hysteresis. If disabled notification is sent out on occurance of the event. If enabled set the hysteresis value using fwuEventNotifHysteresis. Enumeration: 'enable': 1, 'disable': 0.
                                 fwuEventNotifHysteresis 1.3.6.1.4.1.2014.15.2.1.3.5.9 integer32 read-write
Time period, in seconds, for which an event has to persist before a notification is sent. For this value to be useable, ensure that fwuEnableNotifHysteresis is enabled.
                                 fwuEnableNotifInterval 1.3.6.1.4.1.2014.15.2.1.3.5.10 integer read-write
Provision to enable(1) or disable(0) a time lag before sending out an event notification. If disabled, notification is sent out on the occurance of the event. If enabled, use fwuEventNotifInterval to set the lag. Enumeration: 'enable': 1, 'disable': 0.
                                 fwuEventNotifInterval 1.3.6.1.4.1.2014.15.2.1.3.5.11 integer32 read-write
Provision to set the time lag in seconds between the successive event notifications. For this value to be useable, ensure that fwuEnableNotifInterval is enabled.
                                 fwuSchedulerTable 1.3.6.1.4.1.2014.15.2.1.3.5.12 no-access
Table containing information about the trap destinations. For changes to take effect, a (Host) reboot is required.
                                       fwuSchedulerEntry 1.3.6.1.4.1.2014.15.2.1.3.5.12.1 no-access
An entry in the fwuSchedulerTable.
                                           fwuTaskId 1.3.6.1.4.1.2014.15.2.1.3.5.12.1.1 integer no-access
The unique index of the Scheduler table. Range limited to machine integer size(32 bit) restriction.
                                           fwuTaskType 1.3.6.1.4.1.2014.15.2.1.3.5.12.1.2 integer read-only
The task to be scheduled. If System Test is the task being scheduled it requires some more arguments. Use fwuFunctionArgs to provide them. After specifying a task, enable the task using fwuScheduleStatus. Enumeration: 'systemTest': 2, 'iamAliveTrap': 5.
                                           fwuScheduleStatus 1.3.6.1.4.1.2014.15.2.1.3.5.12.1.3 integer read-only
Provision to enable(1) or disable(0) the scheduled task (defined by fwuTaskType). Enumeration: 'enabled': 1, 'notEnabled': 0.
                                           fwuTaskStartTime 1.3.6.1.4.1.2014.15.2.1.3.5.12.1.4 displaystring read-only
The start time of the scheduled activity.
                                           fwuOccurrences 1.3.6.1.4.1.2014.15.2.1.3.5.12.1.5 integer read-only
Provision to set the number of times the task is to be executed. Set a value greater than 0 for a finite number of executions. To keep executing forever, set value to -1.
                                           fwuRecurrence 1.3.6.1.4.1.2014.15.2.1.3.5.12.1.6 displaystring read-only
Provision to set the periodicity of the scheduled task. Eg. S5 is 5 Sec, H6 is 6 Hours, M8 is 8 Min. Note: This is also used for the time interval for sending I am alive traps.
                                           fwuFunctionArgs 1.3.6.1.4.1.2014.15.2.1.3.5.12.1.7 displaystring read-only
Colon separated string of arguments required for the given task type. Can be empty depending on the task type.
                                           fwuRowStatus 1.3.6.1.4.1.2014.15.2.1.3.5.12.1.8 rowstatus read-only
The status of the conceptual row. This is used to manage the creation and deletion of the rows in scheduler table.
                             fwuContactAlarmObjects 1.3.6.1.4.1.2014.15.2.1.3.6
                                 fwuContactAlarmInfo 1.3.6.1.4.1.2014.15.2.1.3.6.1
                                     fwuSystemContactAlarmMgmtTable 1.3.6.1.4.1.2014.15.2.1.3.6.1.1 no-access
Entities in this table are applicable to all Prism and URH remote units. For Host and DRU, entities are applicable only for 2nd generation system cards and onwards.
                                         fwuSystemContactAlarmMgmtEntry 1.3.6.1.4.1.2014.15.2.1.3.6.1.1.1 no-access
An entry (conceptual row) in the fwuSnmpTrapMgrConfigTable.
                                             fwuUnitIndex 1.3.6.1.4.1.2014.15.2.1.3.6.1.1.1.1 unitid2 read-only
The number of the connected unit.
                                             fwuSYstemAlarmCode 1.3.6.1.4.1.2014.15.2.1.3.6.1.1.1.2 unsigned32 read-only
A code that uniquely identifies an alarm.
                                             fwuContactAlarm 1.3.6.1.4.1.2014.15.2.1.3.6.1.1.1.3 displaystring read-only
Hardware Assigned Name.
                                             fwuContactAlarmMode 1.3.6.1.4.1.2014.15.2.1.3.6.1.1.1.4 integer read-write
Provision to set the mode of the alarm as normally closed (1) or normally open (2). Enumeration: 'normallyOpen': 2, 'normallyClose': 1.
                                             fwuContactAlarmName 1.3.6.1.4.1.2014.15.2.1.3.6.1.1.1.5 displaystring read-write
User defined name of the host unit. All characters except angular brackets, single and double quotes are allowed. Minimum length of the name is 0 character (It may be empty.). Maximum length of the name is 64 characters.
                                             fwuContactAlarmEnable 1.3.6.1.4.1.2014.15.2.1.3.6.1.1.1.6 alarmenable read-write
Provision to enable (1) or disable (0) the contact alarm. The alarm is enabled by default.
                                             fwuContactAlarmSeverity 1.3.6.1.4.1.2014.15.2.1.3.6.1.1.1.7 integer read-write
Severity of the alarm. Enumeration: 'major': 3, 'minor': 2.
                                 fwuContactAlarmTraps 1.3.6.1.4.1.2014.15.2.1.3.6.2
                                     fwuHstContactAlarmOutput1 1.3.6.1.4.1.2014.15.2.1.3.6.2.1
Host contact output port state.
                                     fwuHstContactAlarmOutput2 1.3.6.1.4.1.2014.15.2.1.3.6.2.2
Host contact output port state.
                                     fwuHstContactAlarmInput1 1.3.6.1.4.1.2014.15.2.1.3.6.2.3
Host contact input port state.
                                     fwuHstContactAlarmInput2 1.3.6.1.4.1.2014.15.2.1.3.6.2.4
Host contact input port state.
                                     fwuRmtContactAlarmInput1 1.3.6.1.4.1.2014.15.2.1.3.6.2.5
Remote contact input port state- Summary of all connected remotes.
                                     fwuRmtContactAlarmInput2 1.3.6.1.4.1.2014.15.2.1.3.6.2.6
Remote contact input port state- Summary of all connected remotes.
                                     fwuRmtContactAlarmOutput1 1.3.6.1.4.1.2014.15.2.1.3.6.2.7
Remote contact output port state- Summary of all connected remotes.
                                     fwuRmtContactAlarmOutput2 1.3.6.1.4.1.2014.15.2.1.3.6.2.8
Remote contact output port state- Summary of all connected remotes.
                             fwuSystemStaticAlarms 1.3.6.1.4.1.2014.15.2.1.3.7
                                 fwuSystemStaticAlarmsTable 1.3.6.1.4.1.2014.15.2.1.3.7.1 no-access
This is a static alarm table containing the statistics of units in the system. The major and minor alarms will be grouped separately for each of the units.
                                     fwuSystemStaticAlarmsEntry 1.3.6.1.4.1.2014.15.2.1.3.7.1.1 no-access
Entries for units which can be either alarmed or not alarmed or not-discovered.
                                         fwuSystemUnitID 1.3.6.1.4.1.2014.15.2.1.3.7.1.1.1 unitid2 read-only
The ID of the unit from which the alarms has been raised.
                                         fwuSystemUnitType 1.3.6.1.4.1.2014.15.2.1.3.7.1.1.2 unittype read-only
The type of the from which the alarm has been raised.
                                         fwuUnitMajorAlarms 1.3.6.1.4.1.2014.15.2.1.3.7.1.1.3 displaystring read-only
The major alarm name of the unit.
                                         fwuUnitMinorAlarms 1.3.6.1.4.1.2014.15.2.1.3.7.1.1.4 displaystring read-only
The minor alarm name of the unit.
                         flexwaveurhMIBConformance 1.3.6.1.4.1.2014.15.2.1.4
                             flexwaveurhMIBCompliances 1.3.6.1.4.1.2014.15.2.1.4.1
                                 flexwaveurhBasicCompliance 1.3.6.1.4.1.2014.15.2.1.4.1.1
The compliance statement for Flexwave entities which implement the ADC-FLEXWAVE-URH-MIB.
                             flexwaveurhMIBGroups 1.3.6.1.4.1.2014.15.2.1.4.2
                                 fwuSerfGroup 1.3.6.1.4.1.2014.15.2.1.4.2.1
A collection of Host and Remote SERF objects.
                                 fwuOpticsGroup 1.3.6.1.4.1.2014.15.2.1.4.2.2
A collection of Host and Remote Optical and Ethernet port objects.
                                 fwuDartGroup 1.3.6.1.4.1.2014.15.2.1.4.2.3
A collection of Host and Remote DART objects.
                                 fwuLnaGroup 1.3.6.1.4.1.2014.15.2.1.4.2.4
A collection of Host and Remote LNA objects.
                                 fwuLpaGroup 1.3.6.1.4.1.2014.15.2.1.4.2.5
A collection of Host and Remote LPA objects.
                                 fwuDuplexerGroup 1.3.6.1.4.1.2014.15.2.1.4.2.6
A collection of Host and Remote Duplexer objects.
                                 fwuAlarmConfigGroup 1.3.6.1.4.1.2014.15.2.1.4.2.7
A collection of Host and Remote Alarm configuration objects.
                                 fwuNotificationGroup 1.3.6.1.4.1.2014.15.2.1.4.2.8
A collection of Host and Remote Notification objects.
                                 fwuLinkingGroup 1.3.6.1.4.1.2014.15.2.1.4.2.9
A collection of RF linking configuration objects.
                                 fwuMateInfoGroup 1.3.6.1.4.1.2014.15.2.1.4.2.10
A collection of mate information objects.
                                 fwuSprintModeGroup 1.3.6.1.4.1.2014.15.2.1.4.2.11
A collection of objects supported in Sprint mode Objects.
                                 fwuSNMPSettingGroup 1.3.6.1.4.1.2014.15.2.1.4.2.12
A collection of objects supported in System Link test.
                                 fwuSystemStaticAlarmsGroup 1.3.6.1.4.1.2014.15.2.1.4.2.13
A collection of objects supported in Static Alarms Table.