ACD-SFP-MIB: View SNMP OID List / Download MIB

VENDOR: ACCEDIAN


 Home MIB: ACD-SFP-MIB
Download as:   

Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
 acdSfp 1.3.6.1.4.1.22420.2.4
The SFPs database for this Accedian Networks device.
     acdSfpInfoTable 1.3.6.1.4.1.22420.2.4.1 no-access
Table of all SFP info
         acdSfpInfoEntry 1.3.6.1.4.1.22420.2.4.1.1 no-access
This is a part of the content of the SFP's 0xA0 EEPROM
             acdSfpInfoID 1.3.6.1.4.1.22420.2.4.1.1.1 unsigned32 no-access
Unique value for each SFP. Its value ranges from 1 to MAXINT (4 bytes).
             acdSfpInfoConnIdx 1.3.6.1.4.1.22420.2.4.1.1.2 unsigned32 read-only
This object identifies the connector index on the box. The index is assigned form left to rigth starting with 1.
             acdSfpInfoConnType 1.3.6.1.4.1.22420.2.4.1.1.3 integer read-only
The connector value indicates the external optical or electrical cable connector provided as the media interface. Enumeration: 'sfpFIBERJACK': 6, 'sfpFC2COPPER': 3, 'sfpBNC': 4, 'sfpLC': 7, 'sfpFCCOAX': 5, 'sfpMTRJ': 8, 'sfpPIGTAIL': 11, 'sfpMU': 9, 'sfpCOPPERPIGTAIL': 33, 'sfpSG': 10, 'sfpSC': 1, 'sfpHSSDCII': 32, 'sfpFC1COPPER': 2.
             acdSfpInfoVendor 1.3.6.1.4.1.22420.2.4.1.1.4 displaystring read-only
The vendor name is a 16 character field that contains ASCII characters, left-aligned and padded on the right with ASCII spaces (20h). The vendor name shall be the full name of the corporation, a commonly accepted abbreviation of the name of the corporation, the SCSI company code for the corporation, or the stock exchange code for the corporation. At least one of the vendor name or the vendor OUI fields shall contain valid serial data.
             acdSfpInfoVendorOui 1.3.6.1.4.1.22420.2.4.1.1.5 displaystring read-only
The vendor organizationally unique identifier field (vendor OUI) is a 3-byte field that contains the IEEE Company Identifier for the vendor. A value of all zero in the 3-byte field indicates that the Vendor OUI is unspecified.
             acdSfpInfoVendorPn 1.3.6.1.4.1.22420.2.4.1.1.6 displaystring read-only
The vendor part number (vendor PN) is a 16-byte field that contains ASCII characters, leftaligned and padded on the right with ASCII spaces (20h), defining the vendor's part number or product name. A value of all zero in the 16-byte field indicates that the vendor PN is unspecified.
             acdSfpInfoVendorRev 1.3.6.1.4.1.22420.2.4.1.1.7 displaystring read-only
The vendor revision number (vendor rev) is a 4-byte field that contains ASCII characters, leftaligned and padded on the right with ASCII spaces (20h), defining the vendor's product revision number. A value of all zero in the 4-byte field indicates that the vendor PN is unspecified.
             acdSfpInfoWavelength 1.3.6.1.4.1.22420.2.4.1.1.8 unsigned32 read-only
Nominal transmitter output wavelength at room temperature. 16 bit value with byte 60 as high order byte and byte 61 as low order byte. The laser wavelength is equal to the 16 bit integer value in nm. This field allows the user to read the laser wavelength directly, so it is not necessary to infer it from the transceiver Code for Electronic Compatibility.
             acdSfpInfoSerialNum 1.3.6.1.4.1.22420.2.4.1.1.9 displaystring read-only
The vendor serial number (vendor SN) is a 16 character field that contains ASCII characters, left-aligned and padded on the right with ASCII spaces (20h), defining the vendor's serial number for the transceiver. A value of all zero in the 16-byte field indicates that the vendor PN is unspecified.
             acdSfpInfoYear 1.3.6.1.4.1.22420.2.4.1.1.10 unsigned32 read-only
This is the year of manufacturing.
             acdSfpInfoMonth 1.3.6.1.4.1.22420.2.4.1.1.11 unsigned32 read-only
This is the month of manufacturing.
             acdSfpInfoDay 1.3.6.1.4.1.22420.2.4.1.1.12 unsigned32 read-only
This is the day of manufacturing.
             acdSfpInfoLot 1.3.6.1.4.1.22420.2.4.1.1.13 unsigned32 read-only
This is the Lot number of manufacturing.
             acdSfpInfoRev8472 1.3.6.1.4.1.22420.2.4.1.1.14 integer read-only
This is to indicate to which revision this SFP is compatible. Enumeration: 'rev93': 1, 'undefined': 0, 'rev94': 2.
             acdSfpInfoPresent 1.3.6.1.4.1.22420.2.4.1.1.15 truthvalue read-only
This is to indicate if the SFP is present or not.
             acdSfpInfoDiag 1.3.6.1.4.1.22420.2.4.1.1.16 truthvalue read-only
This is to indicate if the SFP supports Digital Diagnostics.
             acdSfpInfoInternal 1.3.6.1.4.1.22420.2.4.1.1.17 truthvalue read-only
This is to indicate if the SFP supports internal calibration. If externally calibrated, the measurements are raw A/D values and must be converted to real world units using calibration constants stored in EEPROM locations 56 to 95 at 2 wire serial bus address A2h. Calibration is valid over vendor specified operating temperature and voltage. Alarm and warning threshold values should be interpreted in the same manner as real time 16 bit data.
             acdSfpInfoAlm 1.3.6.1.4.1.22420.2.4.1.1.18 truthvalue read-only
This is to indicate if the SFP supports Alarm and warning thresholds for the Digital Diagnostics.
             acdSfpInfoIdType 1.3.6.1.4.1.22420.2.4.1.1.19 unsigned32 read-only
The identifier value specifies the physical device described by the two-wire interface information. This value shall be included in the two-wire interface data (see SFF-8472 for details).
             acdSfpInfoExtIdType 1.3.6.1.4.1.22420.2.4.1.1.20 unsigned32 read-only
The extended identifier value provides additional information about the transceiver. The field should be set to 04h for all SFP modules indicating two-wire interface ID module definition (see SFF-8472 for details).
             acdSfpInfoTransCode 1.3.6.1.4.1.22420.2.4.1.1.21 displaystring read-only
The following bit significant indicators define the electronic or optical interfaces that are supported by the transceiver. At least one bit shall be set in this field (see SFF-8472 for details).
     acdSfpDiagTable 1.3.6.1.4.1.22420.2.4.2 no-access
Table of all SFP Digital Diagnostics
         acdSfpDiagEntry 1.3.6.1.4.1.22420.2.4.2.1 no-access
This is a part the content of the SFP's 0xA0 EEPROM
             acdSfpDiagID 1.3.6.1.4.1.22420.2.4.2.1.1 unsigned32 no-access
Unique value for each SFP. Its value ranges from 1 to MAXINT (4 bytes).
             acdSfpDiagConnIdx 1.3.6.1.4.1.22420.2.4.2.1.2 unsigned32 read-only
This object identifies the connector index on the box. The index is assigned form left to rigth starting with 1.
             acdSfpDiagTemp 1.3.6.1.4.1.22420.2.4.2.1.3 integer32 read-only
Internally measured transceiver temperature. Represented as a 16 bit signed twos complement value in degrees Celsius, yielding a total range of -128C to +128C.
             acdSfpDiagVcc 1.3.6.1.4.1.22420.2.4.2.1.4 unsigned32 read-only
Internally measured transceiver supply voltage. Represented as a 16 bit unsigned integer with the voltage defined as the full 16 bit value (0 to 65535) with LSB equal to 100 micro-Volt, yielding a total range of 0 to +6.55 Volts.
             acdSfpDiagLbc 1.3.6.1.4.1.22420.2.4.2.1.5 unsigned32 read-only
Measured TX bias current in micro-Amps yielding a total range of 0 to 131 mA.
             acdSfpDiagTxPwr 1.3.6.1.4.1.22420.2.4.2.1.6 unsigned32 read-only
Measured TX output power in mW. Represented as a 16 bit unsigned integer with the power defined as the full 16 bit value (0 to 65535) with LSB equal to 0.1 micro-Watt, yielding a total range of 0 to 6.5535 mW (~ -40 to +8.2 dBm).
             acdSfpDiagRxPwr 1.3.6.1.4.1.22420.2.4.2.1.7 unsigned32 read-only
Measured Rx input power in mW. Represented as a 16 bit unsigned integer with the power defined as the full 16 bit value (0 to 65535) with LSB equal to 0.1 micro-Watt, yielding a total range of 0 to 6.5535 mW (~ -40 to +8.2 dBm).
             acdSfpDiagTxPwrdBm 1.3.6.1.4.1.22420.2.4.2.1.8 displaystring read-only
Measured TX output power in dBm (~ -40 to +8.2 dBm).
             acdSfpDiagRxPwrdBm 1.3.6.1.4.1.22420.2.4.2.1.9 displaystring read-only
Measured Rx input power in dBm (~ -40 to +8.2 dBm).
     acdSfpThreshTable 1.3.6.1.4.1.22420.2.4.3 no-access
Table of all SFP Alarm and Warning Thresholds
         acdSfpThreshEntry 1.3.6.1.4.1.22420.2.4.3.1 no-access
This is a part the content of the SFP's 0xA0 EEPROM
             acdSfpThreshID 1.3.6.1.4.1.22420.2.4.3.1.1 unsigned32 no-access
Unique value for each SFP. Its value ranges from 1 to MAXINT (4 bytes).
             acdSfpThreshConnIdx 1.3.6.1.4.1.22420.2.4.3.1.2 unsigned32 read-only
This object identifies the connector index on the box. The index is assigned form left to rigth starting with 1.
             acdSfpThreshTempHighAlm 1.3.6.1.4.1.22420.2.4.3.1.3 integer32 read-only
High Alarm transceiver temperature. Represented as a 16 bit signed twos complement value in degrees Celsius, yielding a total range of -128C to +128C.
             acdSfpThreshTempLowAlm 1.3.6.1.4.1.22420.2.4.3.1.4 integer32 read-only
Low Alarm transceiver temperature. Represented as a 16 bit signed twos complement value in degrees Celsius, yielding a total range of -128C to +128C.
             acdSfpThreshTempHighWarn 1.3.6.1.4.1.22420.2.4.3.1.5 integer32 read-only
High Warning transceiver temperature. Represented as a 16 bit signed twos complement value in degrees Celsius, yielding a total range of -128C to +128C.
             acdSfpThreshTempLowWarn 1.3.6.1.4.1.22420.2.4.3.1.6 integer32 read-only
Low Warning transceiver temperature. Represented as a 16 bit signed twos complement value in degrees Celsius, yielding a total range of -128C to +128C.
             acdSfpThreshVccHighAlm 1.3.6.1.4.1.22420.2.4.3.1.7 unsigned32 read-only
High Alarm transceiver supply voltage. Represented as a 16 bit unsigned integer with the voltage defined as the full 16 bit value (0 to 65535) with LSB equal to 100 micro-Volt, yielding a total range of 0 to +6.55 Volts.
             acdSfpThreshVccLowAlm 1.3.6.1.4.1.22420.2.4.3.1.8 unsigned32 read-only
Low Alarm transceiver supply voltage. Represented as a 16 bit unsigned integer with the voltage defined as the full 16 bit value (0 to 65535) with LSB equal to 100 micro-Volt, yielding a total range of 0 to +6.55 Volts.
             acdSfpThreshVccHighWarn 1.3.6.1.4.1.22420.2.4.3.1.9 unsigned32 read-only
High Warning transceiver supply voltage. Represented as a 16 bit unsigned integer with the voltage defined as the full 16 bit value (0 to 65535) with LSB equal to 100 micro-Volt, yielding a total range of 0 to +6.55 Volts.
             acdSfpThreshVccLowWarn 1.3.6.1.4.1.22420.2.4.3.1.10 unsigned32 read-only
Low Warning transceiver supply voltage. Represented as a 16 bit unsigned integer with the voltage defined as the full 16 bit value (0 to 65535) with LSB equal to 100 micro-Volt, yielding a total range of 0 to +6.55 Volts.
             acdSfpThreshLbcHighAlm 1.3.6.1.4.1.22420.2.4.3.1.11 unsigned32 read-only
High Alarm TX bias current in micro-Amps yielding a total range of 0 to 131 mA.
             acdSfpThreshLbcLowAlm 1.3.6.1.4.1.22420.2.4.3.1.12 unsigned32 read-only
Low Alarm TX bias current in micro-Amps yielding a total range of 0 to 131 mA.
             acdSfpThreshLbcHighWarn 1.3.6.1.4.1.22420.2.4.3.1.13 unsigned32 read-only
High Warning TX bias current in micro-Amps yielding a total range of 0 to 131 mA.
             acdSfpThreshLbcLowWarn 1.3.6.1.4.1.22420.2.4.3.1.14 unsigned32 read-only
Low Warning TX bias current in micro-Amps yielding a total range of 0 to 131 mA.
             acdSfpThreshTxPwrHighAlm 1.3.6.1.4.1.22420.2.4.3.1.15 unsigned32 read-only
High Alarm TX output power in mW. Represented as a 16 bit unsigned integer with the power defined as the full 16 bit value (0 to 65535) with LSB equal to 0.1 micro-Watt, yielding a total range of 0 to 6.5535 mW (~ -40 to +8.2 dBm).
             acdSfpThreshTxPwrLowAlm 1.3.6.1.4.1.22420.2.4.3.1.16 unsigned32 read-only
Low Alarm TX output power in mW. Represented as a 16 bit unsigned integer with the power defined as the full 16 bit value (0 to 65535) with LSB equal to 0.1 micro-Watt, yielding a total range of 0 to 6.5535 mW (~ -40 to +8.2 dBm).
             acdSfpThreshTxPwrHighWarn 1.3.6.1.4.1.22420.2.4.3.1.17 unsigned32 read-only
High Warning TX output power in mW. Represented as a 16 bit unsigned integer with the power defined as the full 16 bit value (0 to 65535) with LSB equal to 0.1 micro-Watt, yielding a total range of 0 to 6.5535 mW (~ -40 to +8.2 dBm).
             acdSfpThreshTxPwrLowWarn 1.3.6.1.4.1.22420.2.4.3.1.18 unsigned32 read-only
Low Warning TX output power in mW. Represented as a 16 bit unsigned integer with the power defined as the full 16 bit value (0 to 65535) with LSB equal to 0.1 micro-Watt, yielding a total range of 0 to 6.5535 mW (~ -40 to +8.2 dBm).
             acdSfpThreshRxPwrHighAlm 1.3.6.1.4.1.22420.2.4.3.1.19 unsigned32 read-only
High Alarm RX input power in mW. Represented as a 16 bit unsigned integer with the power defined as the full 16 bit value (0 to 65535) with LSB equal to 0.1 micro-Watt, yielding a total range of 0 to 6.5535 mW (~ -40 to +8.2 dBm).
             acdSfpThreshRxPwrLowAlm 1.3.6.1.4.1.22420.2.4.3.1.20 unsigned32 read-only
Low Alarm RX input power in mW. Represented as a 16 bit unsigned integer with the power defined as the full 16 bit value (0 to 65535) with LSB equal to 0.1 micro-Watt, yielding a total range of 0 to 6.5535 mW (~ -40 to +8.2 dBm).
             acdSfpThreshRxPwrHighWarn 1.3.6.1.4.1.22420.2.4.3.1.21 unsigned32 read-only
High Warning RX input power in mW. Represented as a 16 bit unsigned integer with the power defined as the full 16 bit value (0 to 65535) with LSB equal to 0.1 micro-Watt, yielding a total range of 0 to 6.5535 mW (~ -40 to +8.2 dBm).
             acdSfpThreshRxPwrLowWarn 1.3.6.1.4.1.22420.2.4.3.1.22 unsigned32 read-only
Low Warning RX input power in mW. Represented as a 16 bit unsigned integer with the power defined as the full 16 bit value (0 to 65535) with LSB equal to 0.1 micro-Watt, yielding a total range of 0 to 6.5535 mW (~ -40 to +8.2 dBm).
             acdSfpThreshTxPwrHighAlmdBm 1.3.6.1.4.1.22420.2.4.3.1.23 displaystring read-only
High Alarm TX output power in dBm (~ -40 to +8.2 dBm).
             acdSfpThreshTxPwrLowAlmdBm 1.3.6.1.4.1.22420.2.4.3.1.24 displaystring read-only
Low Alarm TX output power in dBm (~ -40 to +8.2 dBm).
             acdSfpThreshTxPwrHighWarndBm 1.3.6.1.4.1.22420.2.4.3.1.25 displaystring read-only
High Warning TX output power in dBm (~ -40 to +8.2 dBm).
             acdSfpThreshTxPwrLowWarndBm 1.3.6.1.4.1.22420.2.4.3.1.26 displaystring read-only
Low Warning TX output power in dBm (~ -40 to +8.2 dBm).
             acdSfpThreshRxPwrHighAlmdBm 1.3.6.1.4.1.22420.2.4.3.1.27 displaystring read-only
High Alarm Rx input power in dBm (~ -40 to +8.2 dBm).
             acdSfpThreshRxPwrLowAlmdBm 1.3.6.1.4.1.22420.2.4.3.1.28 displaystring read-only
Low Alarm Rx input power in dBm (~ -40 to +8.2 dBm).
             acdSfpThreshRxPwrHighWarndBm 1.3.6.1.4.1.22420.2.4.3.1.29 displaystring read-only
High Warning Rx input power in dBm (~ -40 to +8.2 dBm).
             acdSfpThreshRxPwrLowWarndBm 1.3.6.1.4.1.22420.2.4.3.1.30 displaystring read-only
Low Warning Rx input power in dBm (~ -40 to +8.2 dBm).
     acdSfpThreshStatusTable 1.3.6.1.4.1.22420.2.4.4 no-access
Table of all SFP Digital Diagnostics Thresholds statuses
         acdSfpThreshStatusEntry 1.3.6.1.4.1.22420.2.4.4.1 no-access
This is a part the content of the SFP's 0xA2 EEPROM
             acdSfpThreshStatusID 1.3.6.1.4.1.22420.2.4.4.1.1 unsigned32 no-access
Unique value for each SFP. Its value ranges from 1 to MAXINT (4 bytes).
             acdSfpThreshStatusConnIdx 1.3.6.1.4.1.22420.2.4.4.1.2 unsigned32 read-only
This object identifies the connector index on the box. The index is assigned form left to rigth starting with 1.
             acdSfpThreshStatusTempHighAlm 1.3.6.1.4.1.22420.2.4.4.1.3 truthvalue read-only
This is to indicate if the temperature reaches or overpasses the High alarm threshold.
             acdSfpThreshStatusTempLowAlm 1.3.6.1.4.1.22420.2.4.4.1.4 truthvalue read-only
This is to indicate if the temperature reaches or underpasses the Low alarm threshold.
             acdSfpThreshStatusTempHighWarn 1.3.6.1.4.1.22420.2.4.4.1.5 truthvalue read-only
This is to indicate if the temperature reaches or overpasses the High warning threshold.
             acdSfpThreshStatusTempLowWarn 1.3.6.1.4.1.22420.2.4.4.1.6 truthvalue read-only
This is to indicate if the temperature reaches or underpasses the Low warning threshold.
             acdSfpThreshStatusVccHighAlm 1.3.6.1.4.1.22420.2.4.4.1.7 truthvalue read-only
This is to indicate if the supply voltage reaches or overpasses the High alarm threshold.
             acdSfpThreshStatusVccLowAlm 1.3.6.1.4.1.22420.2.4.4.1.8 truthvalue read-only
This is to indicate if the supply voltage reaches or underpasses the Low alarm threshold.
             acdSfpThreshStatusVccHighWarn 1.3.6.1.4.1.22420.2.4.4.1.9 truthvalue read-only
This is to indicate if the supply voltage reaches or overpasses the High warning threshold.
             acdSfpThreshStatusVccLowWarn 1.3.6.1.4.1.22420.2.4.4.1.10 truthvalue read-only
This is to indicate if the supply voltage reaches or underpasses the Low warning threshold.
             acdSfpThreshStatusLbcHighAlm 1.3.6.1.4.1.22420.2.4.4.1.11 truthvalue read-only
This is to indicate if the Laser Bias Current reaches or overpasses the High alarm threshold.
             acdSfpThreshStatusLbcLowAlm 1.3.6.1.4.1.22420.2.4.4.1.12 truthvalue read-only
This is to indicate if the Laser Bias Current reaches or underpasses the Low alarm threshold.
             acdSfpThreshStatusLbcHighWarn 1.3.6.1.4.1.22420.2.4.4.1.13 truthvalue read-only
This is to indicate if the Laser Bias Current reaches or overpasses the High warning threshold.
             acdSfpThreshStatusLbcLowWarn 1.3.6.1.4.1.22420.2.4.4.1.14 truthvalue read-only
This is to indicate if the Laser Bias Current reaches or underpasses the Low warning threshold.
             acdSfpThreshStatusTxPwrHighAlm 1.3.6.1.4.1.22420.2.4.4.1.15 truthvalue read-only
This is to indicate if the Transmit Power reaches or overpasses the High alarm threshold.
             acdSfpThreshStatusTxPwrLowAlm 1.3.6.1.4.1.22420.2.4.4.1.16 truthvalue read-only
This is to indicate if the Transmit Power reaches or underpasses the Low alarm threshold.
             acdSfpThreshStatusTxPwrHighWarn 1.3.6.1.4.1.22420.2.4.4.1.17 truthvalue read-only
This is to indicate if the Transmit Power reaches or overpasses the High warning threshold.
             acdSfpThreshStatusTxPwrLowWarn 1.3.6.1.4.1.22420.2.4.4.1.18 truthvalue read-only
This is to indicate if the Transmit Power reaches or underpasses the Low warning threshold.
             acdSfpThreshStatusRxPwrHighAlm 1.3.6.1.4.1.22420.2.4.4.1.19 truthvalue read-only
This is to indicate if the Receive Power reaches or overpasses the High alarm threshold.
             acdSfpThreshStatusRxPwrLowAlm 1.3.6.1.4.1.22420.2.4.4.1.20 truthvalue read-only
This is to indicate if the Receive Power reaches or underpasses the Low alarm threshold.
             acdSfpThreshStatusRxPwrHighWarn 1.3.6.1.4.1.22420.2.4.4.1.21 truthvalue read-only
This is to indicate if the Receive Power reaches or overpasses the High warning threshold.
             acdSfpThreshStatusRxPwrLowWarn 1.3.6.1.4.1.22420.2.4.4.1.22 truthvalue read-only
This is to indicate if the Receive Power reaches or underpasses the Low warning threshold.
     acdSfpNotifications 1.3.6.1.4.1.22420.2.4.5
     acdSfpMIBObjects 1.3.6.1.4.1.22420.2.4.6
     acdSfpConformance 1.3.6.1.4.1.22420.2.4.7
         acdSfpCompliances 1.3.6.1.4.1.22420.2.4.7.1
             acdSfpCompliance 1.3.6.1.4.1.22420.2.4.7.1.1
The compliance statement for support of the ACD-SFP-MIB module.
         acdSfpGroups 1.3.6.1.4.1.22420.2.4.7.2
             acdSfpInfoGroup 1.3.6.1.4.1.22420.2.4.7.2.1
Objects for the SFP information Group.
             acdSfpDiagGroup 1.3.6.1.4.1.22420.2.4.7.2.2
Objects for the SFP diagnostics Group.
             acdSfpThreshGroup 1.3.6.1.4.1.22420.2.4.7.2.3
Objects for the SFP thresholds Group.
             acdSfpThreshStatusGroup 1.3.6.1.4.1.22420.2.4.7.2.4
Objects for the SFP threshold status Group.