AC-SS7-MIB: View SNMP OID List / Download MIB

VENDOR: AUDIOCODES LTD


 Home MIB: AC-SS7-MIB
Download as:   

Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
 acSS7 1.3.6.1.4.1.5003.9.10.12
       acSS7Configuration 1.3.6.1.4.1.5003.9.10.12.1
           acSS7MTP2 1.3.6.1.4.1.5003.9.10.12.1.1
               acSS7MTP2M3bSlDiscardCongThreshold 1.3.6.1.4.1.5003.9.10.12.1.1.1 unsigned32 read-write
This parameter concerns feature that prevents uncontrolled increase of the MTP2 Transmit queue when the upper levels ignores the usual flow control mechanism. Any new SL_TX_MSU_RQ is discarded when the number of msu queued on the TB or RTB overtakes the threshold. Value 0, means that this feature is not activated. Access: Offline. AC INI-Param: SS7M3bSlDiscardCongThreshold
               acSS7MTP2AttribTable 1.3.6.1.4.1.5003.9.10.12.1.1.21 no-access
                     acSS7MTP2AttribEntry 1.3.6.1.4.1.5003.9.10.12.1.1.21.1 no-access
                         acSS7MTP2AttribIndex 1.3.6.1.4.1.5003.9.10.12.1.1.21.1.1 unsigned32 no-access
Index Field for line. AC INI-Param: SS7Mtp2Parms_Index
                         acSS7MTP2AttribIsUsed 1.3.6.1.4.1.5003.9.10.12.1.1.21.1.2 integer read-only
Is the row used by alink. If it is the entrow will be read. AC INI-Param: N/A Enumeration: 'yes': 1, 'no': 0.
                         acSS7MTP2AttribLinkRate 1.3.6.1.4.1.5003.9.10.12.1.1.21.1.3 snmpadminstring read-only
Defines the SS7 SLI Link Rate. Choose either: A = 64 kbps D = 56 kbps 0 = 64 kbps. Access: Online. AC INI-Param: SS7Mtp2Parms_LinkRate
                         acSS7MTP2AttribErrorCorectionMethod 1.3.6.1.4.1.5003.9.10.12.1.1.21.1.4 snmpadminstring read-only
Defines the SLI error correction method. B = Basic P = PCR (Preventive Cyclic Retransmission). Access: Online. AC INI-Param: SS7Mtp2Parms_ErrorCorrectionMethod
                         acSS7MTP2AttribIacCp 1.3.6.1.4.1.5003.9.10.12.1.1.21.1.5 unsigned32 read-only
Defines the number of aborted proving attempts before sending an out-of-service to MTP-3. Access: Online. AC INI-Param: SS7Mtp2Parms_IacCp
                         acSS7MTP2AttribSUERMThreshold 1.3.6.1.4.1.5003.9.10.12.1.1.21.1.6 unsigned32 read-only
Defines the SS7 SUERM (Signal Unit Error Rate Monitor) T threshold. Access: Online. AC INI-Param: SS7Mtp2Parms_SuermT
                         acSS7MTP2AttribAERMNormalThreshold 1.3.6.1.4.1.5003.9.10.12.1.1.21.1.7 unsigned32 read-only
Normal AERM (alignment error rate monitor) threshold [0 to 20]. Access: Online. AC INI-Param: SS7Mtp2Parms_AermTin
                         acSS7MTP2AttribAERMEmerglThreshold 1.3.6.1.4.1.5003.9.10.12.1.1.21.1.8 unsigned32 read-only
Emergency AERM (alignment error rate monitor) threshold [0 to 10]. Access: Online. AC INI-Param: SS7Mtp2Parms_AermTie
                         acSS7MTP2AttribSUERMSigUnitDThreshold 1.3.6.1.4.1.5003.9.10.12.1.1.21.1.9 unsigned32 read-only
Defines the SS7 Signal Unit error rate monitor D threshold. Access: Online. AC INI-Param: SS7Mtp2Parms_SuermSuD
                         acSS7MTP2AttribOctetCounting 1.3.6.1.4.1.5003.9.10.12.1.1.21.1.10 unsigned32 read-only
Defines the SS7 MTP2 Octet received while the OCTET is in counting mode (# of Octets received - N Octets - while in Octet counting mode). Access: Online. AC INI-Param: SS7Mtp2Parms_OctetCounting
                         acSS7MTP2AttribTimerT1 1.3.6.1.4.1.5003.9.10.12.1.1.21.1.11 unsigned32 read-only
Defines the SS7 MTP2 T1 alignment ready timer (in msecs). Access: Online. AC INI-Param: SS7Mtp2Parms_T1
                         acSS7MTP2AttribTimerT2 1.3.6.1.4.1.5003.9.10.12.1.1.21.1.12 unsigned32 read-only
Defines the SS7 MTP2 T2 unaligned timer (in msecs). Access: Online. AC INI-Param: SS7Mtp2Parms_T2
                         acSS7MTP2AttribTimerT3 1.3.6.1.4.1.5003.9.10.12.1.1.21.1.13 unsigned32 read-only
Defines the SS7 MTP2 T3 timer aligned. Access: Online. AC INI-Param: SS7Mtp2Parms_T3
                         acSS7MTP2AttribTimerT4Normal 1.3.6.1.4.1.5003.9.10.12.1.1.21.1.14 unsigned32 read-only
Defines the SS7 MTP2 T4n Normal proving period timer. Access: Online. AC INI-Param: SS7Mtp2Parms_T4n
                         acSS7MTP2AttribTimerT4Emerg 1.3.6.1.4.1.5003.9.10.12.1.1.21.1.15 unsigned32 read-only
Defines the SS7 MTP2 T4e Emergency proving period timer (msec). Access: Online. AC INI-Param: SS7Mtp2Parms_T4e
                         acSS7MTP2AttribTimerT5 1.3.6.1.4.1.5003.9.10.12.1.1.21.1.16 unsigned32 read-only
Defines the SS7 MTP2 Sending SIB timer. Access: Online. AC INI-Param: SS7Mtp2Parms_T5
                         acSS7MTP2AttribTimerT6 1.3.6.1.4.1.5003.9.10.12.1.1.21.1.17 unsigned32 read-only
Defines the SS7 MTP2 Remote Congestion timer (in msec). Access: Online. AC INI-Param: SS7Mtp2Parms_T6
                         acSS7MTP2AttribTimerT7 1.3.6.1.4.1.5003.9.10.12.1.1.21.1.18 unsigned32 read-only
Defines the SS7 MTP2 excessive delay of the ack timer (in msec). Access: Online. AC INI-Param: SS7Mtp2Parms_T7
                         acSS7MTP2AttribLSSULength 1.3.6.1.4.1.5003.9.10.12.1.1.21.1.19 unsigned32 read-only
Defines the SS7 MTP2 LSSU length as 1 or 2 (bytes). Access: Online. AC INI-Param: SS7Mtp2Parms_LssuLength
                         acSS7MTP2AttribPcrN2 1.3.6.1.4.1.5003.9.10.12.1.1.21.1.20 unsigned32 read-only
This parameter is used to define Preventive Cyclic Retransmission - the number of message signal unit octets available for retransmission (ITU-T Q703 6.4 - Forced retransmission). Access: Online. AC INI-Param: SS7Mtp2Parms_PcrN2
                         acSS7MTP2AttribRowStatus 1.3.6.1.4.1.5003.9.10.12.1.1.21.1.21 rowstatus read-only
ROWSTATUS Field for line. AC INI-Param: N/A
           acSS7Timers 1.3.6.1.4.1.5003.9.10.12.1.2
               acSS7SignalingNodeTimersTable 1.3.6.1.4.1.5003.9.10.12.1.2.21 no-access
                     acSS7SignalingNodeTimersEntry 1.3.6.1.4.1.5003.9.10.12.1.2.21.1 no-access
                         acSS7SignalingNodeTimersIndex 1.3.6.1.4.1.5003.9.10.12.1.2.21.1.1 unsigned32 no-access
Index Field for line. AC INI-Param: SS7_SNTIMERS_INDEX
                         acSS7SignalingNodeTimersIsUsed 1.3.6.1.4.1.5003.9.10.12.1.2.21.1.2 integer read-only
AC INI-Param: N/A Enumeration: 'yes': 1, 'no': 0.
                         acSS7SignalingNodeTimersAction 1.3.6.1.4.1.5003.9.10.12.1.2.21.1.3 integer read-write
management Field for ACTIONS. AC INI-Param: SS7_SNTIMERS_ACTION Enumeration: 'none': 0.
                         acSS7SignalingNodeTimersActionResult 1.3.6.1.4.1.5003.9.10.12.1.2.21.1.4 integer read-only
management Field for ACTIONS RESULT. AC INI-Param: SS7_SNTIMERS_ACTION_RESULT Enumeration: 'failed': 2, 'inProgress': 1, 'succeeded': 0.
                         acSS7SignalingNodeTimersName 1.3.6.1.4.1.5003.9.10.12.1.2.21.1.5 snmpadminstring read-write
String name for SN timer-set. Access: Online. AC INI-Param: SS7_SNTIMERS_NAME
                         acSS7SignalingNodeTimersT6 1.3.6.1.4.1.5003.9.10.12.1.2.21.1.6 unsigned32 read-write
Delay to avoid message mis-sequencing on controlled rerouting. Access: Online. AC INI-Param: SS7_SNTIMERS_T6
                         acSS7SignalingNodeTimersT8 1.3.6.1.4.1.5003.9.10.12.1.2.21.1.7 unsigned32 read-write
Transfer prohibited inhibition timer (transient solution). Access: Online. AC INI-Param: SS7_SNTIMERS_T8
                         acSS7SignalingNodeTimersT10 1.3.6.1.4.1.5003.9.10.12.1.2.21.1.8 unsigned32 read-write
Waiting to repeat signalling route set test message. Access: Online. AC INI-Param: SS7_SNTIMERS_T10
                         acSS7SignalingNodeTimersT11 1.3.6.1.4.1.5003.9.10.12.1.2.21.1.9 unsigned32 read-write
Transfer restricted timer. Access: Online. AC INI-Param: SS7_SNTIMERS_T11
                         acSS7SignalingNodeTimersT15 1.3.6.1.4.1.5003.9.10.12.1.2.21.1.10 unsigned32 read-write
Waiting to start signalling route set congestion test. Access: Online. AC INI-Param: SS7_SNTIMERS_T15
                         acSS7SignalingNodeTimersT16 1.3.6.1.4.1.5003.9.10.12.1.2.21.1.11 unsigned32 read-write
Waiting for route set congestion status update. Access: Online. AC INI-Param: SS7_SNTIMERS_T16
                         acSS7SignalingNodeTimersT18ITU 1.3.6.1.4.1.5003.9.10.12.1.2.21.1.12 unsigned32 read-write
Timer within a signalling point whose MTP restarts for supervising link and link set activation as well as the receipt of routing information. Access: Online. AC INI-Param: SS7_SNTIMERS_T18_ITU
                         acSS7SignalingNodeTimersT19ITU 1.3.6.1.4.1.5003.9.10.12.1.2.21.1.13 unsigned32 read-write
Supervision timer during MTP restart to avoid possible ping-pong of TFP, TFR and TRA messages. Access: Online. AC INI-Param: SS7_SNTIMERS_T19_ITU
                         acSS7SignalingNodeTimersT20ITU 1.3.6.1.4.1.5003.9.10.12.1.2.21.1.14 unsigned32 read-write
Overall MTP restart timer at the signalling point whose MTP restarts. Access: Online. AC INI-Param: SS7_SNTIMERS_T20_ITU
                         acSS7SignalingNodeTimersT21ITU 1.3.6.1.4.1.5003.9.10.12.1.2.21.1.15 unsigned32 read-write
Overall MTP restart timer at a signalling point adjacent to one whose MTP restarts. Access: Online. AC INI-Param: SS7_SNTIMERS_T21_ITU
                         acSS7SignalingNodeTimersT24ITU 1.3.6.1.4.1.5003.9.10.12.1.2.21.1.16 unsigned32 read-write
Stabilising timer after removal of local processor outage, used in LPO latching to RPO (national option). Access: Online. AC INI-Param: SS7_SNTIMERS_T24_ITU
                         acSS7SignalingNodeTimersT22ANSI 1.3.6.1.4.1.5003.9.10.12.1.2.21.1.17 unsigned32 read-write
Timer at restarting SP waiting for signalling links to bacome available. Access: Online. AC INI-Param: SS7_SNTIMERS_T22_ANSI
                         acSS7SignalingNodeTimersT23ANSI 1.3.6.1.4.1.5003.9.10.12.1.2.21.1.18 unsigned32 read-write
Timer at restarting SP, started after T22, waiting to receive all traffic restart allowed messages. Access: Online. AC INI-Param: SS7_SNTIMERS_T23_ANSI
                         acSS7SignalingNodeTimersT24ANSI 1.3.6.1.4.1.5003.9.10.12.1.2.21.1.19 unsigned32 read-write
Timer at restarting SP with transfer function, started after T23, waiting to broadcast all traffic restart allowed messages. Access: Online. AC INI-Param: SS7_SNTIMERS_T24_ANSI
                         acSS7SignalingNodeTimersT25ANSI 1.3.6.1.4.1.5003.9.10.12.1.2.21.1.20 unsigned32 read-write
Timer at SP adjacent to restarting SP waiting for traffic restart allowed message. Access: Online. AC INI-Param: SS7_SNTIMERS_T25_ANSI
                         acSS7SignalingNodeTimersT26ANSI 1.3.6.1.4.1.5003.9.10.12.1.2.21.1.21 unsigned32 read-write
Timer at restarting SP waiting to repeat traffic restart waiting message. Access: Online. AC INI-Param: SS7_SNTIMERS_T26_ANSI
                         acSS7SignalingNodeTimersT27ANSI 1.3.6.1.4.1.5003.9.10.12.1.2.21.1.22 unsigned32 read-write
This parameter is used to define the minimum duration of unavailability for a full restart. Access: Online. AC INI-Param: SS7_SNTIMERS_T27_ANSI
                         acSS7SignalingNodeTimersT28ANSI 1.3.6.1.4.1.5003.9.10.12.1.2.21.1.23 unsigned32 read-write
Timer at SP adjacent to restarting SP waiting for traffic restart waiting message. Access: Online. AC INI-Param: SS7_SNTIMERS_T28_ANSI
                         acSS7SignalingNodeTimersT29ANSI 1.3.6.1.4.1.5003.9.10.12.1.2.21.1.24 unsigned32 read-write
Timer started when TRA sent in response to unexpected TRA or TRW. Access: Online. AC INI-Param: SS7_SNTIMERS_T29_ANSI
                         acSS7SignalingNodeTimersT30ANSI 1.3.6.1.4.1.5003.9.10.12.1.2.21.1.25 unsigned32 read-write
Timer to limit sending of TFPs and TFRs in response to unexpected TRA or TRW. Access: Online. AC INI-Param: SS7_SNTIMERS_T30_ANSI
               acSS7LinkSetTimersTable 1.3.6.1.4.1.5003.9.10.12.1.2.22 no-access
                     acSS7LinkSetTimersEntry 1.3.6.1.4.1.5003.9.10.12.1.2.22.1 no-access
                         acSS7LinkSetTimersIndex 1.3.6.1.4.1.5003.9.10.12.1.2.22.1.1 unsigned32 no-access
Index Field for line. AC INI-Param: acSS7LKSETTIMERS_PS_PARAMETER_INDEX
                         acSS7LinkSetTimersIsUsed 1.3.6.1.4.1.5003.9.10.12.1.2.22.1.2 integer read-only
AC INI-Param: N/A Enumeration: 'yes': 1, 'no': 0.
                         acSS7LinkSetTimersAction 1.3.6.1.4.1.5003.9.10.12.1.2.22.1.3 integer read-write
management Field for ACTIONS. AC INI-Param: SS7_LKSETTIMERS_ACTION Enumeration: 'none': 0.
                         acSS7LinkSetTimersActionResult 1.3.6.1.4.1.5003.9.10.12.1.2.22.1.4 integer read-only
management Field for ACTIONS RESULT. AC INI-Param: SS7_LKSETTIMERS_ACTION_RESULT Enumeration: 'failed': 2, 'inProgress': 1, 'succeeded': 0.
                         acSS7LinkSetTimersName 1.3.6.1.4.1.5003.9.10.12.1.2.22.1.5 snmpadminstring read-write
String name for Linkset timer-set. Access: Online. AC INI-Param: SS7_LKSETTIMERS_NAME
                         acSS7LinkSetTimersT1SLT 1.3.6.1.4.1.5003.9.10.12.1.2.22.1.6 unsigned32 read-write
Supervision timer for signalling link test acknowledgement message. Access: Online. AC INI-Param: SS7_LKSETTIMERS_T1SLT
                         acSS7LinkSetTimersT2SLT 1.3.6.1.4.1.5003.9.10.12.1.2.22.1.7 unsigned32 read-write
Interval timer for sending signalling link test messages. Access: Online. AC INI-Param: SS7_LKSETTIMERS_T2SLT
                         acSS7LinkSetTimersT1 1.3.6.1.4.1.5003.9.10.12.1.2.22.1.8 unsigned32 read-write
Delay to avoid message mis-sequencing on changeover. Access: Online. AC INI-Param: SS7_LKSETTIMERS_T1
                         acSS7LinkSetTimersT2 1.3.6.1.4.1.5003.9.10.12.1.2.22.1.9 unsigned32 read-write
Waiting for changeover acknowledgement. Access: Online. AC INI-Param: SS7_LKSETTIMERS_T2
                         acSS7LinkSetTimersT3 1.3.6.1.4.1.5003.9.10.12.1.2.22.1.10 unsigned32 read-write
Time controlled diversion-delay to avoid mis-sequencing on changeback. Access: Online. AC INI-Param: SS7_LKSETTIMERS_T3
                         acSS7LinkSetTimersT4 1.3.6.1.4.1.5003.9.10.12.1.2.22.1.11 unsigned32 read-write
Waiting for changeback acknowledgement (first attempt). Access: Online. AC INI-Param: SS7_LKSETTIMERS_T4
                         acSS7LinkSetTimersT5 1.3.6.1.4.1.5003.9.10.12.1.2.22.1.12 unsigned32 read-write
Waiting for changeback acknowledgement (second attempt). Access: Online. AC INI-Param: SS7_LKSETTIMERS_T5
                         acSS7LinkSetTimersT7 1.3.6.1.4.1.5003.9.10.12.1.2.22.1.13 unsigned32 read-write
Waiting for signalling data link connection acknowledgement. Access: Online. AC INI-Param: SS7_LKSETTIMERS_T7
                         acSS7LinkSetTimersT12 1.3.6.1.4.1.5003.9.10.12.1.2.22.1.14 unsigned32 read-write
Waiting for uninhibit acknowledgement. Access: Online. AC INI-Param: SS7_LKSETTIMERS_T12
                         acSS7LinkSetTimersT13 1.3.6.1.4.1.5003.9.10.12.1.2.22.1.15 unsigned32 read-write
Waiting for force uninhibit. Access: Online. AC INI-Param: SS7_LKSETTIMERS_T13
                         acSS7LinkSetTimersT14 1.3.6.1.4.1.5003.9.10.12.1.2.22.1.16 unsigned32 read-write
Waiting for inhibition acknowledgement. Access: Online. AC INI-Param: SS7_LKSETTIMERS_T14
                         acSS7LinkSetTimersT17 1.3.6.1.4.1.5003.9.10.12.1.2.22.1.17 unsigned32 read-write
Delay to avoid oscillation of initial alignment failure and link restart. Access: Online. AC INI-Param: SS7_LKSETTIMERS_T17
                         acSS7LinkSetTimersT20ANSI 1.3.6.1.4.1.5003.9.10.12.1.2.22.1.18 unsigned32 read-write
Local inhibit test timer. Access: Online. AC INI-Param: SS7_LKSETTIMERS_T20_ANSI
                         acSS7LinkSetTimersT21ANSI 1.3.6.1.4.1.5003.9.10.12.1.2.22.1.19 unsigned32 read-write
Remote inhibit test timer. Access: Online. AC INI-Param: SS7_LKSETTIMERS_T21_ANSI
                         acSS7LinkSetTimersT22ITU 1.3.6.1.4.1.5003.9.10.12.1.2.22.1.20 unsigned32 read-write
Local inhibit test timer. Access: Online. AC INI-Param: SS7_LKSETTIMERS_T22_ITU
                         acSS7LinkSetTimersT23ITU 1.3.6.1.4.1.5003.9.10.12.1.2.22.1.21 unsigned32 read-write
Remote inhibit test timer. Access: Online. AC INI-Param: SS7_LKSETTIMERS_T23_ITU
           acSS7Links 1.3.6.1.4.1.5003.9.10.12.1.3
               acSS7LinkCommonTable 1.3.6.1.4.1.5003.9.10.12.1.3.21 no-access
                     acSS7LinkCommonEntry 1.3.6.1.4.1.5003.9.10.12.1.3.21.1 no-access
                         acSS7LinkCommonIndex 1.3.6.1.4.1.5003.9.10.12.1.3.21.1.1 unsigned32 no-access
Index Field for line. AC INI-Param: MAX_SIGNALING_LINKS_PER_CARD
                         acSS7LinkCommonRowStatus 1.3.6.1.4.1.5003.9.10.12.1.3.21.1.2 rowstatus read-only
ROWSTATUS Field for line. AC INI-Param: SS7_LINK_ROWSTATUS
                         acSS7LinkCommonAction 1.3.6.1.4.1.5003.9.10.12.1.3.21.1.3 integer read-only
management Field for ACTIONS. AC INI-Param: SS7_LINK_ACTION Enumeration: 'inhibit': 5, 'activate': 3, 'deActivate': 4, 'none': 0, 'lpr': 8, 'lpo': 7, 'unInhibit': 6, 'offLine': 1, 'inService': 2.
                         acSS7LinkCommonActionResult 1.3.6.1.4.1.5003.9.10.12.1.3.21.1.4 integer read-only
management Field for ACTIONS RESULT. AC INI-Param: SS7_LINK_ACTION_RESULT Enumeration: 'failed': 2, 'inProgress': 1, 'succeeded': 0.
                         acSS7LinkCommonName 1.3.6.1.4.1.5003.9.10.12.1.3.21.1.5 snmpadminstring read-only
String name for Link paramaters. Access: Online. AC INI-Param: SS7_LINK_NAME
                         acSS7LinkCommonAdminState 1.3.6.1.4.1.5003.9.10.12.1.3.21.1.6 integer read-only
Administrative state of singnalling link. AC INI-Param: SS7_LINK_ADMINISTRATIVE_STATE Enumeration: 'offLine': 0, 'inService': 2.
                         acSS7LinkCommonOperState 1.3.6.1.4.1.5003.9.10.12.1.3.21.1.7 integer read-only
Operational state of singnalling link. AC INI-Param: SS7_LINK_OPERATIONAL_STATE Enumeration: 'offLine': 0, 'busy': 1, 'inService': 2.
                         acSS7LinkCommonTraceLevel 1.3.6.1.4.1.5003.9.10.12.1.3.21.1.8 integer read-only
Trace level of singnalling link (level 2). Access: Online. AC INI-Param: SS7_LINK_TRACE_LEVEL Enumeration: 'traceLevel0': 0, 'traceLevel1': 1.
                         acSS7LinkCommonL2TypeSelector 1.3.6.1.4.1.5003.9.10.12.1.3.21.1.9 integer read-only
Link layer 2 type - defines level 2 media of signaling link. Access: Online. AC INI-Param: SS7_LINK_L2_TYPE Enumeration: 'nonetype-L2': 0, 'm2ua-mgc': 2, 'mtp2': 1, 'ss7monitoring': 4.
                         acSS7LinkCommonL3TypeSelector 1.3.6.1.4.1.5003.9.10.12.1.3.21.1.10 integer read-only
Link high layer type - defines level 3 or L2 high layer of signalling link. Access: Online. AC INI-Param: SS7_LINK_L3_TYPE Enumeration: 'ss7monitoring': 5, 'm2ua-sg': 1, 'mtp3': 2, 'mtp2-tunneling': 3, 'nonetype-L3': 0, 'mtp2OverIP': 4.
                         acSS7LinkCommonVariant 1.3.6.1.4.1.5003.9.10.12.1.3.21.1.11 integer read-only
Variant (layer 2) of singnalling link (TDM). Access: Online. AC INI-Param: SS7_LINK_LAYER2_VARIANT Enumeration: 'ansi': 2, 'it': 1, 'china': 3.
                         acSS7LinkCommonMtcBusy 1.3.6.1.4.1.5003.9.10.12.1.3.21.1.12 integer read-only
Link local busy indicator - if set, indicates link is busy due to local mtc action. AC INI-Param: SS7_LINK_MTC_BUSY Enumeration: 'yes': 1, 'no': 0.
                         acSS7LinkCommonRdcyBoardNum 1.3.6.1.4.1.5003.9.10.12.1.3.21.1.13 integer read-only
Board number in which the link is physically connected. Access: Online. AC INI-Param: SS7_LINK_RDCY_BOARD Enumeration: 'rdcyBoardNum2': 2, 'rdcyBoardNum1': 1, 'rdcyBoardNum0': 0.
                         acSS7LinkCommonMonSuFilterRequest 1.3.6.1.4.1.5003.9.10.12.1.3.21.1.14 integer read-only
SS7 Monitoring link SU filter- Defines the type of SU message to filter. 0: Filter all types of SU messages 1: Filter LSSU and FISU messages 2: Filter only FISU messages 3: Do not filter any message. Access: Online. AC INI-Param: SS7_LINK_MON_SU_FILTER Enumeration: 'noFilter': 3, 'filterAll': 0, 'filterFISU': 2, 'filterLSSUandFISU': 1.
               acSS7LinkTDMTable 1.3.6.1.4.1.5003.9.10.12.1.3.22 no-access
                     acSS7LinkTDMEntry 1.3.6.1.4.1.5003.9.10.12.1.3.22.1 no-access
                         acSS7LinkTDMTrunkNumber 1.3.6.1.4.1.5003.9.10.12.1.3.22.1.1 integer32 read-only
Trunk number of singnalling link (TDM). Access: Online. AC INI-Param: SS7_LINK_TRUNK_NUMBER
                         acSS7LinkTDMTimeSlotNumber 1.3.6.1.4.1.5003.9.10.12.1.3.22.1.2 unsigned32 read-only
Time-Slot number of singnalling link (TDM). Access: Online. AC INI-Param: SS7_LINK_TIMESLOT_NUMBER
                         acSS7LinkTDMInhibit 1.3.6.1.4.1.5003.9.10.12.1.3.22.1.3 integer read-only
Link inhibit indicator - if set, indicates link is inhibited.. AC INI-Param: SS7_LINK_INHIBITION Enumeration: 'inhibited': 1, 'unInhibited': 0.
                         acSS7LinkTDMMtp2Atts 1.3.6.1.4.1.5003.9.10.12.1.3.22.1.4 integer read-only
MTP2 attributes of singnalling link (TDM). Access: Online. AC INI-Param: SS7_LINK_MTP2_ATTRIBUTES Enumeration: 'mtp2Atts2': 2, 'mtp2Atts3': 3, 'mtp2Atts0': 0, 'mtp2Atts1': 1.
                         acSS7LinkTDMCongestionLowMark 1.3.6.1.4.1.5003.9.10.12.1.3.22.1.5 unsigned32 read-only
Link congestion low mark of signalling link (TDM). Access: Online. AC INI-Param: SS7_CONGESTION_LOW_MARK
                         acSS7LinkTDMCongestionHighMark 1.3.6.1.4.1.5003.9.10.12.1.3.22.1.6 unsigned32 read-only
Link congestion high mark of signalling link (TDM). Access: Online. AC INI-Param: SS7_CONGESTION_HIGH_MARK
                         acSS7LinkTDMBlock 1.3.6.1.4.1.5003.9.10.12.1.3.22.1.7 integer read-only
Link blocked indicator. AC INI-Param: SS7_LINK_BLOCKED Enumeration: 'l3linkunblocked': 0, 'l3linkremoteblockde': 2, 'l3linklocalandremotelocked': 3, 'l3linklocalblocked': 1.
               acSS7LinkSigTranTable 1.3.6.1.4.1.5003.9.10.12.1.3.23 no-access
                     acSS7LinkSigTranEntry 1.3.6.1.4.1.5003.9.10.12.1.3.23.1 no-access
                         acSS7LinkSigTranGroupId 1.3.6.1.4.1.5003.9.10.12.1.3.23.1.1 integer32 read-only
Group ID (M2UA) of signaling link. Access: Online. AC INI-Param: SS7_LINK_GROUP_ID
                         acSS7LinkSigTranIfid 1.3.6.1.4.1.5003.9.10.12.1.3.23.1.2 integer32 read-only
Interface ID (M2UA) of singnalling link. Access: Online. AC INI-Param: SS7_LINK_M2UA_IF_ID
               acSS7LinkATMTable 1.3.6.1.4.1.5003.9.10.12.1.3.24 no-access
                     acSS7LinkATMEntry 1.3.6.1.4.1.5003.9.10.12.1.3.24.1 no-access
                         acSS7LinkATMSAALLinkProfileNum 1.3.6.1.4.1.5003.9.10.12.1.3.24.1.1 unsigned32 read-only
ATM SAAL Link profile number. Access: Online. AC INI-Param: ATM_SAAL_LINK_PROFILE_NUM
                         acSS7LinkATMSAALLinkType 1.3.6.1.4.1.5003.9.10.12.1.3.24.1.2 integer read-only
ATM SAAL link Type PVC/SVC. Access: Online. AC INI-Param: ATM_SAAL_LINK_TYPE Enumeration: 'aTM-VCC-Type-SVC': 1, 'aTM-VCC-Type-PVC': 0.
                         acSS7LinkATMSAALLinkInterfaceNum 1.3.6.1.4.1.5003.9.10.12.1.3.24.1.3 unsigned32 read-only
ATM SAAL link port num. Access: Online. AC INI-Param: ATM_SAAL_LINK_PORT_NUM
                         acSS7LinkATMSAALLinkVPI 1.3.6.1.4.1.5003.9.10.12.1.3.24.1.4 unsigned32 read-only
ATM SAAL link VPI. Access: Online. AC INI-Param: ATM_SAAL_LINK_VPI
                         acSS7LinkATMSAALLinkVCI 1.3.6.1.4.1.5003.9.10.12.1.3.24.1.5 unsigned32 read-only
ATM SAAL link VCI. Access: Online. AC INI-Param: ATM_SAAL_LINK_VCI
               acSS7LinkTNLTable 1.3.6.1.4.1.5003.9.10.12.1.3.25 no-access
                     acSS7LinkTNLEntry 1.3.6.1.4.1.5003.9.10.12.1.3.25.1 no-access
                         acSS7LinkTNLOtherSideLinkNum 1.3.6.1.4.1.5003.9.10.12.1.3.25.1.1 unsigned32 read-only
MTP2 Tunneling: MGC link number (MTP2 'other side' of signaling link). Access: Online. AC INI-Param: SS7_LINK_TNL_MGC_LINK_NUMBER
                         acSS7LinkTNLAlignmentMode 1.3.6.1.4.1.5003.9.10.12.1.3.25.1.2 integer read-only
MTP2 Tunneling: Alignment mode of signalling links in tunnel. Access: Online. AC INI-Param: SS7_LINK_TNL_ALIGNMENT_MODE Enumeration: 'emergency': 1, 'normal': 0.
                         acSS7LinkTNLCongestionMode 1.3.6.1.4.1.5003.9.10.12.1.3.25.1.3 integer read-only
MTP2 Tunneling: Congestion mode of signalling links in tunnel. Access: Online. AC INI-Param: SS7_LINK_TNL_CONGESTION_MODE Enumeration: 'discard': 1, 'accept': 0.
                         acSS7LinkTNLWaitStartCompTimer 1.3.6.1.4.1.5003.9.10.12.1.3.25.1.4 unsigned32 read-only
MTP2 Tunneling: wait start complete timer. Access: Online. AC INI-Param: SS7_LINK_TNL_WAIT_START_COMPLETE_TIMER
                         acSS7LinkTNLOosStartDelayTimer 1.3.6.1.4.1.5003.9.10.12.1.3.25.1.5 unsigned32 read-only
MTP2 Tunneling: OOS start delay timer. Access: Online. AC INI-Param: SS7_LINK_TNL_OOS_START_DELAY_TIMER
                         acSS7LinkTNLWaitOtherSideInsvTimer 1.3.6.1.4.1.5003.9.10.12.1.3.25.1.6 unsigned32 read-only
MTP2 Tunneling: wait for other side to be in service timer. Access: Online. AC INI-Param: SS7_LINK_TNL_WAIT_OTHER_SIDE_INSV_TIMER
           acSS7Nodes 1.3.6.1.4.1.5003.9.10.12.1.4
               acSS7SignalingNodeTable 1.3.6.1.4.1.5003.9.10.12.1.4.21 no-access
                     acSS7SignalingNodeEntry 1.3.6.1.4.1.5003.9.10.12.1.4.21.1 no-access
                         acSS7SignalingNodeIndex 1.3.6.1.4.1.5003.9.10.12.1.4.21.1.1 unsigned32 no-access
AC INI-Param: SS7_SN_INDEX
                         acSS7SignalingNodeRowStatus 1.3.6.1.4.1.5003.9.10.12.1.4.21.1.2 rowstatus read-only
ROWSTATUS Field for line. AC INI-Param: SS7_SN_ROWSTATUS
                         acSS7SignalingNodeAction 1.3.6.1.4.1.5003.9.10.12.1.4.21.1.3 integer read-only
management Field for ACTIONS. AC INI-Param: SS7_SN_ACTION Enumeration: 'start': 2, 'none': 0, 'stop': 1, 'offLine': 4, 'inService': 3.
                         acSS7SignalingNodeActionResult 1.3.6.1.4.1.5003.9.10.12.1.4.21.1.4 integer read-only
management Field for ACTIONS RESULT. AC INI-Param: SS7_SN_ACTION_RESULT Enumeration: 'failed': 2, 'inProgress': 1, 'succeeded': 0.
                         acSS7SignalingNodeName 1.3.6.1.4.1.5003.9.10.12.1.4.21.1.5 snmpadminstring read-only
String name for SN Params. Access: Online. AC INI-Param: SS7_SN_NAME
                         acSS7SignalingNodeTraceLevel 1.3.6.1.4.1.5003.9.10.12.1.4.21.1.6 integer read-only
Trace level of singnalling node (level 3). Access: Online. AC INI-Param: SS7_SN_TRACE_LEVEL Enumeration: 'traceLevel0': 0, 'traceLevel1': 1.
                         acSS7SignalingNodeAdminState 1.3.6.1.4.1.5003.9.10.12.1.4.21.1.7 integer read-only
Administrative state of singnalling node. AC INI-Param: SS7_SN_ADMINISTRATIVE_STATE Enumeration: 'offLine': 0, 'inService': 2.
                         acSS7SignalingNodeOperState 1.3.6.1.4.1.5003.9.10.12.1.4.21.1.8 integer read-only
Operational state of singnalling node. AC INI-Param: SS7_SN_OPERATIONAL_STATE Enumeration: 'offLine': 0, 'busy': 1, 'inService': 2.
                         acSS7SignalingNodeMtcBusy 1.3.6.1.4.1.5003.9.10.12.1.4.21.1.9 integer read-only
Manual busy status of singnalling node. AC INI-Param: SS7_SN_MTC_BUSY_STATUS Enumeration: 'yes': 1, 'no': 0.
                         acSS7SignalingNodeVariant 1.3.6.1.4.1.5003.9.10.12.1.4.21.1.10 integer read-only
Variant of singnalling node. Access: Online. AC INI-Param: SS7_SN_VARIANT Enumeration: 'ansi': 2, 'it': 1, 'china': 3.
                         acSS7SignalingNodeNwIndicator 1.3.6.1.4.1.5003.9.10.12.1.4.21.1.11 integer read-only
Network Indicator of singnalling node. Access: Online. AC INI-Param: SS7_SN_NI Enumeration: 'international': 0, 'national': 2, 'nationalSpare': 3, 'internationalSpare': 1.
                         acSS7SignalingNodeSpStp 1.3.6.1.4.1.5003.9.10.12.1.4.21.1.12 integer read-only
Routing function of singnalling node. Access: Online. AC INI-Param: SS7_SN_SP_STP Enumeration: 'sp': 0, 'stp': 1.
                         acSS7SignalingNodeTfc 1.3.6.1.4.1.5003.9.10.12.1.4.21.1.13 integer read-only
TFC function of singnalling node. Access: Online. AC INI-Param: SS7_SN_TFC Enumeration: 'yes': 1, 'no': 0.
                         acSS7SignalingNodeOpc 1.3.6.1.4.1.5003.9.10.12.1.4.21.1.14 unsigned32 read-only
Origination (local) point-code of singnalling node. Access: Online. AC INI-Param: SS7_SN_OPC
                         acSS7SignalingNodeRouteSetCongestionWindow 1.3.6.1.4.1.5003.9.10.12.1.4.21.1.15 unsigned32 read-only
Routeset Congestion Size (messages) of singnalling node. Access: Online. AC INI-Param: SS7_SN_ROUTESET_CONGESTION_WINSIZE
                         acSS7SignalingNodeTimersIdx 1.3.6.1.4.1.5003.9.10.12.1.4.21.1.16 integer read-only
Index of SNTimers table used for this signaling node. Access: Online. AC INI-Param: SS7_SN_TIMERS_INDEX Enumeration: 'timersIdx3': 3, 'timersIdx2': 2, 'timersIdx1': 1, 'timersIdx0': 0, 'timersIdx4': 4.
                         acSS7SignalingNodeIsupApp 1.3.6.1.4.1.5003.9.10.12.1.4.21.1.17 integer read-only
Level 4 application that handles ISUP traffic for this singnalling node. Access: Online. AC INI-Param: SS7_SN_ISUP_APP Enumeration: 'l4Gen': 7, 'ual': 4, 'nill': 0.
                         acSS7SignalingNodeSccpApp 1.3.6.1.4.1.5003.9.10.12.1.4.21.1.18 integer read-only
Level 4 application that handles SCCP traffic for this singnalling node. Access: Online. AC INI-Param: SS7_SN_SCCP_APP Enumeration: 'l4Gen': 7, 'ual': 4, 'nill': 0.
                         acSS7SignalingNodeBisupApp 1.3.6.1.4.1.5003.9.10.12.1.4.21.1.19 integer read-only
Level 4 application that handles BISUP traffic for this singnalling node. Access: Online. AC INI-Param: SS7_SN_BISUP_APP Enumeration: 'l4Gen': 7, 'ual': 4, 'nill': 0.
                         acSS7SignalingNodeAlcapApp 1.3.6.1.4.1.5003.9.10.12.1.4.21.1.20 integer read-only
Level 4 application that handles ALCAP traffic for this singnalling node. Access: Online. AC INI-Param: SS7_SN_ALCAP_APP Enumeration: 'l4Gen': 7, 'alcap': 5, 'ual': 4, 'nill': 0.
                         acSS7SignalingNodeRdcyOpc 1.3.6.1.4.1.5003.9.10.12.1.4.21.1.21 unsigned32 read-only
Internal point-code of singnalling node - in case of SS7 shared point code. AC INI-Param: SS7_SN_RDCY_OPC
                         acSS7SignalingNodeTupApp 1.3.6.1.4.1.5003.9.10.12.1.4.21.1.22 integer read-only
Level 4 application that handles TUP traffic for this signaling node. Access: Online. AC INI-Param: SS7_SN_TUP_APP Enumeration: 'l4Gen': 7, 'ual': 4, 'nill': 0.
                         acSS7SignalingNodeBiccApp 1.3.6.1.4.1.5003.9.10.12.1.4.21.1.23 integer read-only
Level 4 application that handles BICC traffic for this signaling node. Access: Online. AC INI-Param: SS7_SN_BICC_APP Enumeration: 'ual': 4, 'nil': 0.
               acSS7LinkSets 1.3.6.1.4.1.5003.9.10.12.1.4.31
                     acSS7LinkSetTable 1.3.6.1.4.1.5003.9.10.12.1.4.31.21 no-access
                           acSS7LinkSetEntry 1.3.6.1.4.1.5003.9.10.12.1.4.31.21.1 no-access
                               acSS7LinkSetSNIndex 1.3.6.1.4.1.5003.9.10.12.1.4.31.21.1.1 unsigned32 no-access
First Index Field for line. AC INI-Param: SS7_LINKSET_SN_INDEX
                               acSS7LinkSetLksetIndex 1.3.6.1.4.1.5003.9.10.12.1.4.31.21.1.2 unsigned32 no-access
Second Index Field for line. AC INI-Param: SS7_LINKSET_LINKSET_INDEX
                               acSS7LinkSetRowStatus 1.3.6.1.4.1.5003.9.10.12.1.4.31.21.1.3 rowstatus read-only
ROWSTATUS Field for line. AC INI-Param: SS7_LINKSET_ROWSTATUS
                               acSS7LinkSetAction 1.3.6.1.4.1.5003.9.10.12.1.4.31.21.1.4 integer read-only
management Field for ACTIONS. AC INI-Param: SS7_LINKSET_ACTION Enumeration: 'deActivate': 4, 'none': 0, 'activate': 3, 'offLine': 1, 'inService': 2.
                               acSS7LinkSetActionResult 1.3.6.1.4.1.5003.9.10.12.1.4.31.21.1.5 integer read-only
management Field for ACTIONS RESULT. AC INI-Param: SS7_SN_ACTION_RESULT Enumeration: 'failed': 2, 'inProgress': 1, 'succeeded': 0.
                               acSS7LinkSetName 1.3.6.1.4.1.5003.9.10.12.1.4.31.21.1.6 snmpadminstring read-only
String name for LINKSET Params. Access: Online. AC INI-Param: SS7_LINKSET_NAME
                               acSS7LinkSetAdminState 1.3.6.1.4.1.5003.9.10.12.1.4.31.21.1.7 integer read-only
Administrative state of singnalling linkset. AC INI-Param: SS7_LINKSET_ADMINISTRATIVE_STATE Enumeration: 'offLine': 0, 'inService': 2.
                               acSS7LinkSetOperState 1.3.6.1.4.1.5003.9.10.12.1.4.31.21.1.8 integer read-only
Operational state of singnalling linkset. AC INI-Param: SS7_LINKSET_OPERATIONAL_STATE Enumeration: 'offLine': 0, 'busy': 1, 'inService': 2.
                               acSS7LinkSetMtcBusyState 1.3.6.1.4.1.5003.9.10.12.1.4.31.21.1.9 integer read-only
Manual busy status of singnalling linkset. AC INI-Param: SS7_LINKSET_MTC_BUSY_STATUS Enumeration: 'yes': 1, 'no': 0.
                               acSS7LinkSetDPC 1.3.6.1.4.1.5003.9.10.12.1.4.31.21.1.10 unsigned32 read-only
Destination Point-Code of singnalling linkset. Access: Online. AC INI-Param: SS7_LINKSET_DPC
                               acSS7LinkSetLinksMask 1.3.6.1.4.1.5003.9.10.12.1.4.31.21.1.11 unsigned32 read-only
Mask for links within singnalling linkset. Access: Online. AC INI-Param: SS7_LINKSET_MASK
                               acSS7LinkSetLinksAltMask 1.3.6.1.4.1.5003.9.10.12.1.4.31.21.1.12 unsigned32 read-only
Alternate mask for links within singnalling linkset. Access: Online. AC INI-Param: SS7_LINKSET_ALTERNATE_MASK
                               acSS7LinkSetTimersIdx 1.3.6.1.4.1.5003.9.10.12.1.4.31.21.1.13 integer read-only
Timers Index of singnalling linkset. Access: Online. AC INI-Param: SS7_LINKSET_TIMERS_INDEX Enumeration: 'timersIdx3': 3, 'timersIdx2': 2, 'timersIdx1': 1, 'timersIdx0': 0, 'timersIdx4': 4.
                     acSS7LinkSetLinkTable 1.3.6.1.4.1.5003.9.10.12.1.4.31.22 no-access
                           acSS7LinkSetLinkEntry 1.3.6.1.4.1.5003.9.10.12.1.4.31.22.1 no-access
                               acSS7LinkSetLinkSNIndex 1.3.6.1.4.1.5003.9.10.12.1.4.31.22.1.1 unsigned32 no-access
First Index Field for line: Signalling Node Number. AC INI-Param: SS7_LINKSETLINK_SN_INDEX
                               acSS7LinkSetLinkLinksetIndex 1.3.6.1.4.1.5003.9.10.12.1.4.31.22.1.2 unsigned32 no-access
Second Index Field for line: Signalling Linkset Number. AC INI-Param: SS7_LINKSETLINK_LINKSET_INDEX
                               acSS7LinkSetLinkInnerLinkIndex 1.3.6.1.4.1.5003.9.10.12.1.4.31.22.1.3 unsigned32 no-access
Third Index Field for line: Inner Link Index in Signalling Linkset. AC INI-Param: SS7_LINKSETLINK_INNER_LINK_INDEX
                               acSS7LinkSetLinkRowStatus 1.3.6.1.4.1.5003.9.10.12.1.4.31.22.1.4 rowstatus read-only
ROWSTATUS Field for line. AC INI-Param: SS7_LINKSETLINK_ROWSTATUS
                               acSS7LinkSetLinkAction 1.3.6.1.4.1.5003.9.10.12.1.4.31.22.1.5 integer read-only
management Field for ACTIONS. AC INI-Param: SS7_LINKSETLINK_ACTION Enumeration: 'none': 0.
                               acSS7LinkSetLinkActionResult 1.3.6.1.4.1.5003.9.10.12.1.4.31.22.1.6 integer read-only
Management field for ACTIONS RESULT. AC INI-Param: SS7_LINKSETLINK_ACTION_RESULT Enumeration: 'failed': 2, 'inProgress': 1, 'succeeded': 0.
                               acSS7LinkSetLinkLinkNo 1.3.6.1.4.1.5003.9.10.12.1.4.31.22.1.7 unsigned32 read-only
Physical number of signalling link which is part of the Linkset. Access: Online. AC INI-Param: SS7_LINKSETLINK_LINK_NUMBER
                               acSS7LinkSetLinkLinkSlc 1.3.6.1.4.1.5003.9.10.12.1.4.31.22.1.8 unsigned32 read-only
SLC number of signaling link which is part of the Linkset. Access: Online. AC INI-Param: SS7_LINKSETLINK_LINK_SLC
               acSS7RouteSets 1.3.6.1.4.1.5003.9.10.12.1.4.32
                     acSS7RouteSetTable 1.3.6.1.4.1.5003.9.10.12.1.4.32.21 no-access
                           acSS7RouteSetEntry 1.3.6.1.4.1.5003.9.10.12.1.4.32.21.1 no-access
                               acSS7RouteSetSNIndex 1.3.6.1.4.1.5003.9.10.12.1.4.32.21.1.1 unsigned32 no-access
First Index Field for line: Signalling Node Number. AC INI-Param: SS7_ROUTESET_SN_INDEX
                               acSS7RouteSetIndex 1.3.6.1.4.1.5003.9.10.12.1.4.32.21.1.2 unsigned32 no-access
Second Index Field for line: Signalling Routeset Number. AC INI-Param: SS7_ROUTESET_INDEX
                               acSS7RouteSetRowStatus 1.3.6.1.4.1.5003.9.10.12.1.4.32.21.1.3 rowstatus read-only
ROWSTATUS Field for line. AC INI-Param: SS7_ROUTESET_ROWSTATUS
                               acSS7RouteSetAction 1.3.6.1.4.1.5003.9.10.12.1.4.32.21.1.4 integer read-only
management Field for ACTIONS. AC INI-Param: SS7_ROUTESET_ACTION Enumeration: 'none': 0, 'offLine': 1, 'inService': 2.
                               acSS7RouteSetActionResult 1.3.6.1.4.1.5003.9.10.12.1.4.32.21.1.5 integer read-only
management Field for ACTIONS RESULT. AC INI-Param: SS7_ROUTESET_ACTION_RESULT Enumeration: 'failed': 2, 'inProgress': 1, 'succeeded': 0.
                               acSS7RouteSetName 1.3.6.1.4.1.5003.9.10.12.1.4.32.21.1.6 snmpadminstring read-only
String name for ROUTESET Params. Access: Online. AC INI-Param: SS7_ROUTESET_NAME
                               acSS7RouteSetAdminState 1.3.6.1.4.1.5003.9.10.12.1.4.32.21.1.7 integer read-only
Administrative state of signalling route set. AC INI-Param: SS7_ROUTESET_ADMINISTRATIVE_STATE Enumeration: 'offLine': 0, 'inService': 2.
                               acSS7RouteSetOperState 1.3.6.1.4.1.5003.9.10.12.1.4.32.21.1.8 integer read-only
Operational state of signalling route set. AC INI-Param: SS7_ROUTESET_OPERATIONAL_STATE Enumeration: 'offLine': 0, 'busy': 1, 'inService': 2.
                               acSS7RouteSetDPC 1.3.6.1.4.1.5003.9.10.12.1.4.32.21.1.9 unsigned32 read-only
Destination Point-Code of singnalling routesetset. Access: Online. AC INI-Param: SS7_ROUTESET_DPC
                               acSS7RouteSetRouteMask 1.3.6.1.4.1.5003.9.10.12.1.4.32.21.1.10 unsigned32 read-only
Mask for route within signaling routeset. Access: Online. AC INI-Param: SS7_ROUTESET_MASK
                     acSS7RouteSetRouteTable 1.3.6.1.4.1.5003.9.10.12.1.4.32.22 no-access
                           acSS7RouteSetRouteEntry 1.3.6.1.4.1.5003.9.10.12.1.4.32.22.1 no-access
                               acSS7RouteSetRouteSNIndex 1.3.6.1.4.1.5003.9.10.12.1.4.32.22.1.1 unsigned32 no-access
First Index Field for line: Signalling Node Number. AC INI-Param: SS7_ROUTESETROUTE_SN_INDEX
                               acSS7RouteSetRouteRoutesetIndex 1.3.6.1.4.1.5003.9.10.12.1.4.32.22.1.2 unsigned32 no-access
Second Index Field for line: Signalling Routeset Number. AC INI-Param: SS7_ROUTESETROUTE_ROUTESET_INDEX
                               acSS7RouteSetRouteInnerRouteIndex 1.3.6.1.4.1.5003.9.10.12.1.4.32.22.1.3 unsigned32 no-access
Third Index Field for line: Inner Route Index in Signalling Routeset. AC INI-Param: SS7_ROUTESETROUTE_INNER_ROUTE_INDEX
                               acSS7RouteSetRouteRowStatus 1.3.6.1.4.1.5003.9.10.12.1.4.32.22.1.4 rowstatus read-only
ROWSTATUS Field for line. AC INI-Param: SS7_ROUTESETROUTE_ROWSTATUS
                               acSS7RouteSetRouteAction 1.3.6.1.4.1.5003.9.10.12.1.4.32.22.1.5 integer read-only
management Field for ACTIONS. AC INI-Param: SS7_ROUTESETROUTE_ACTION Enumeration: 'none': 0.
                               acSS7RouteSetRouteActionResult 1.3.6.1.4.1.5003.9.10.12.1.4.32.22.1.6 integer read-only
management Field for ACTIONS RESULT. AC INI-Param: SS7_ROUTESETROUTE_ACTION_RESULT Enumeration: 'failed': 2, 'inProgress': 1, 'succeeded': 0.
                               acSS7RouteSetRouteLinkSetNo 1.3.6.1.4.1.5003.9.10.12.1.4.32.22.1.7 unsigned32 read-only
Number of signalling linkset which is part of the Routeset. Access: Online. AC INI-Param: SS7_ROUTESETROUTE_LINKSET_NUMBER
                               acSS7RouteSetRoutePriority 1.3.6.1.4.1.5003.9.10.12.1.4.32.22.1.8 unsigned32 read-only
Priority of route within routeset. Access: Online. AC INI-Param: SS7_ROUTESETROUTE_PRIORITY
               acSS7AliasPointCode 1.3.6.1.4.1.5003.9.10.12.1.4.33
                     acSS7APCTable 1.3.6.1.4.1.5003.9.10.12.1.4.33.21 no-access
                           acSS7APCEntry 1.3.6.1.4.1.5003.9.10.12.1.4.33.21.1 no-access
                               acSS7APCSNIndex 1.3.6.1.4.1.5003.9.10.12.1.4.33.21.1.1 unsigned32 no-access
First Index Field for line: Signaling Node Number. AC INI-Param: SS7_APC_SN_INDEX
                               acSS7APCIndex 1.3.6.1.4.1.5003.9.10.12.1.4.33.21.1.2 unsigned32 no-access
Second Index Field for line: Alias PC index. AC INI-Param: SS7_APC_INNER_INDEX
                               acSS7APCRowStatus 1.3.6.1.4.1.5003.9.10.12.1.4.33.21.1.3 rowstatus read-only
ROWSTATUS Field for line. AC INI-Param: SS7_APC_ROWSTATUS
                               acSS7APCAction 1.3.6.1.4.1.5003.9.10.12.1.4.33.21.1.4 integer read-only
Management field for ACTIONS. AC INI-Param: SS7_APC_ACTION Enumeration: 'deActivate': 4, 'none': 0, 'activate': 3, 'offLine': 1, 'inService': 2.
                               acSS7APCActionResult 1.3.6.1.4.1.5003.9.10.12.1.4.33.21.1.5 integer read-only
management Field for ACTIONS RESULT. AC INI-Param: SS7_APC_ACTION_RESULT Enumeration: 'failed': 2, 'inProgress': 1, 'succeeded': 0.
                               acSS7APCPC 1.3.6.1.4.1.5003.9.10.12.1.4.33.21.1.6 unsigned32 read-only
Alias Point-Code of signaling node. Access: Online. AC INI-Param: SS7_APC_PC
                               acSS7APCSNI 1.3.6.1.4.1.5003.9.10.12.1.4.33.21.1.7 unsigned32 read-only
SNI (Signaling Network Indicator) of Alias Point-Code. Access: Online. AC INI-Param: SS7_APC_SNI
                               acSS7APCName 1.3.6.1.4.1.5003.9.10.12.1.4.33.21.1.8 snmpadminstring read-only
String name for Alias PC parameters. Access: Online. AC INI-Param: SS7_ALIAS_PC_NAME
                               acSS7APCMtcBusy 1.3.6.1.4.1.5003.9.10.12.1.4.33.21.1.9 integer read-only
Manual busy status of Alias PC. AC INI-Param: SS7_ALIAS_PC_MTC_BUSY Enumeration: 'yes': 1, 'no': 0.
                               acSS7APCAdminState 1.3.6.1.4.1.5003.9.10.12.1.4.33.21.1.10 integer read-only
Administrative state of Alias PC. AC INI-Param: SS7_ALIAS_PC_ADMINISTRATIVE_STATE Enumeration: 'offLine': 0, 'busy': 1, 'inService': 2.
                               acSS7APCOperState 1.3.6.1.4.1.5003.9.10.12.1.4.33.21.1.11 integer read-only
Operational state of Alias PC. AC INI-Param: SS7_ALIAS_PC_OPERATIONAL_STATE Enumeration: 'offLine': 0, 'busy': 1, 'inService': 2.
           acSS7SigTran 1.3.6.1.4.1.5003.9.10.12.1.5
               acSS7SigTranM3UATrafficBehavior 1.3.6.1.4.1.5003.9.10.12.1.5.1 integer read-write
Defines the M3UA behavior when the SS7 links are up, but there is no association to the soft switch. 0 = NONE (no special behavior) 1 = DEACTIVATE (busy links) 2 = SIPO (LPO links). Access: Offline. AC INI-Param: SS7M3UATrafficBehavior Enumeration: 'deactivate': 1, 'none': 0, 'sIPO': 2.
               acSS7SigTranIFGroupTable 1.3.6.1.4.1.5003.9.10.12.1.5.21 no-access
                     acSS7SigTranIFGroupEntry 1.3.6.1.4.1.5003.9.10.12.1.5.21.1 no-access
                         acSS7SigTranIFGroupIndex 1.3.6.1.4.1.5003.9.10.12.1.5.21.1.1 unsigned32 no-access
Index field for line. AC INI-Param: SS7_SIG_IF_GR_INDEX
                         acSS7SigTranIFGroupRowStatus 1.3.6.1.4.1.5003.9.10.12.1.5.21.1.2 rowstatus read-only
ROWSTATUS field for line. AC INI-Param: SS7_SIG_IF_GR_ROWSTATUS
                         acSS7SigTranIFGroupAction 1.3.6.1.4.1.5003.9.10.12.1.5.21.1.3 integer read-only
Management field for ACTION. AC INI-Param: SS7_SIG_IF_GR_ACTION Enumeration: 'deActivate': 2, 'none': 0, 'activate': 1.
                         acSS7SigTranIFGroupActionResult 1.3.6.1.4.1.5003.9.10.12.1.5.21.1.4 unsigned32 read-only
Management field for ACTION RESULT. AC INI-Param: SS7_SIG_IF_GR_ACTION_RESULT
                         acSS7SigTranIFGroupId 1.3.6.1.4.1.5003.9.10.12.1.5.21.1.5 unsigned32 read-only
SS7 (Signaling System 7) SIGTRAN (Signaling Transport) Interface Group Id. Access: Online. AC INI-Param: SS7_IF_GR_ID
                         acSS7SigTranIFGroupSgMgc 1.3.6.1.4.1.5003.9.10.12.1.5.21.1.6 integer read-only
Interface Group function - Signaling Gateway (SG) or Media Gateway Controller (MGC). Access: Online. AC INI-Param: SS7_SIG_SG_MGC Enumeration: 'mgc': 77, 'sg': 83, 'nat': 1.
                         acSS7SigTranIFGroupSignalingLayer 1.3.6.1.4.1.5003.9.10.12.1.5.21.1.7 integer read-only
UAL type of interface group: 0 = none 1 = iua 2 = m2ua 3 = m3ua 4 = m2tunnel 5 = V5ua 6 = dua 7=isdnTunnel. Access: Online. AC INI-Param: SS7_SIG_LAYER Enumeration: 'm2tunnel': 4, 'noLayer': 0, 'iua': 1, 'dua': 6, 'isdnTunnel': 7, 'm2ua': 2, 'm3ua': 3.
                         acSS7SigTranIFGroupTrafMode 1.3.6.1.4.1.5003.9.10.12.1.5.21.1.8 integer read-only
Traffic mode of interface group. Access: Online. AC INI-Param: SS7_SIG_TRAF_MODE Enumeration: 'override': 1, 'broadcast': 3, 'loadShare': 2.
                         acSS7SigTranIFGroupRecovTimer 1.3.6.1.4.1.5003.9.10.12.1.5.21.1.9 unsigned32 read-only
T(r) - recovery timer (in msecs) of interface group. Access: Online. AC INI-Param: SS7_SIG_T_REC
                         acSS7SigTranIFGroupAckTimer 1.3.6.1.4.1.5003.9.10.12.1.5.21.1.10 unsigned32 read-only
T(ack) - wait timer for ASP_UP_ACK (in msecs) of interface group. Access: Online. AC INI-Param: SS7_SIG_T_ACK
                         acSS7SigTranIFGroupHBTimer 1.3.6.1.4.1.5003.9.10.12.1.5.21.1.11 unsigned32 read-only
T(beat) - Heartbeat Timer (in msecs) of interface group. Access: Online. AC INI-Param: SS7_SIG_T_HB
                         acSS7SigTranIFGroupMinAsp 1.3.6.1.4.1.5003.9.10.12.1.5.21.1.12 unsigned32 read-only
Minimal ASP (Application Server Process) number in interface group(minimum = 1). Access: Online. AC INI-Param: SS7_SIG_MIN_ASP
                         acSS7SigTranIFGroupBehavior 1.3.6.1.4.1.5003.9.10.12.1.5.21.1.13 unsigned32 read-only
Behavior bit of interface group. Access: Online. AC INI-Param: SS7_SIG_BEHAVIOUR
                         acSS7SigTranIFGroupSCTPInst 1.3.6.1.4.1.5003.9.10.12.1.5.21.1.14 unsigned32 read-only
SCTP (Stream Control Transmission Protocol) instance of interface group. AC INI-Param: SS7_SCTP_INSTANCE
                         acSS7SigTranIFGroupSCTPLocalPort 1.3.6.1.4.1.5003.9.10.12.1.5.21.1.15 unsigned32 read-only
Local SCTP (Stream Control Transmission Protocol) port of interface group. Access: Online. AC INI-Param: SS7_LOCAL_SCTP_PORT
                         acSS7SigTranIFGroupNetwork 1.3.6.1.4.1.5003.9.10.12.1.5.21.1.16 integer read-only
Network variant of interface group. Access: Online. AC INI-Param: SS7_SIG_NETWORK Enumeration: 'ansi': 2, 'it': 1, 'china': 3.
                         acSS7SigTranIFGroupSCTPDestPort 1.3.6.1.4.1.5003.9.10.12.1.5.21.1.17 unsigned32 read-only
Destination SCTP (Stream Control Transmission Protocol) port. Access: Online. AC INI-Param: SS7_DEST_SCTP_PORT
                         acSS7SigTranIFGroupDestIp 1.3.6.1.4.1.5003.9.10.12.1.5.21.1.18 ipaddress read-only
Destination SCTP (Stream Control Transmission Protocol) IP address. Access: Online. AC INI-Param: SS7_DEST_IP
                         acSS7SigTranIFGroupSCTPMaxInbStreams 1.3.6.1.4.1.5003.9.10.12.1.5.21.1.19 unsigned32 read-only
Maximum inbound streams in interface group. Access: Online. AC INI-Param: SS7_MGC_MX_IN_STREAM
                         acSS7SigTranIFGroupSCTPMaxOutbStreams 1.3.6.1.4.1.5003.9.10.12.1.5.21.1.20 unsigned32 read-only
Number of output streams required in interface group. Access: Online. AC INI-Param: SS7_MGC_NUM_OUT_STREAM
                         acSS7SigTranIFGroupRdcyBoardNum 1.3.6.1.4.1.5003.9.10.12.1.5.21.1.21 unsigned32 read-only
This parameter is used to specify the SIGTRAN (Signaling Transport) group redundancy board number. Access: Online. AC INI-Param: RdcyBoardNum
                         acSS7SigTranIFGroupRoutingContextIndex 1.3.6.1.4.1.5003.9.10.12.1.5.21.1.22 integer32 read-only
Entry in Routing Context table, that contains the routing context rules for this interface group. Access: Online. AC INI-Param: SS7_SIG_RC_INDEX
                         acSS7SigTranIFGroupRoutingContextValue 1.3.6.1.4.1.5003.9.10.12.1.5.21.1.23 integer32 read-only
Routing context value for this interface group (AS). Access: Online. AC INI-Param: SS7_SIG_RC_VALUE
                         acSS7SigTranIFGroupNetworkAppearance 1.3.6.1.4.1.5003.9.10.12.1.5.21.1.24 integer32 read-only
Network Appearance value for this interface group (AS). Access: Online. AC INI-Param: SS7_SIG_NETWORK_APPEARANCE
               acSS7SigTranIFIDTable 1.3.6.1.4.1.5003.9.10.12.1.5.22 no-access
                     acSS7SigTranIFIDEntry 1.3.6.1.4.1.5003.9.10.12.1.5.22.1 no-access
                         acSS7SigTranIFIDIndex 1.3.6.1.4.1.5003.9.10.12.1.5.22.1.1 unsigned32 no-access
Index field for line. AC INI-Param: SS7_SIG_IF_ID_INDEX
                         acSS7SigTranIFIDRowStatus 1.3.6.1.4.1.5003.9.10.12.1.5.22.1.2 rowstatus read-only
ROWSTATUS field for line. AC INI-Param: SS7_SIG_IF_ID_ROWSTATUS
                         acSS7SigTranIFIDAction 1.3.6.1.4.1.5003.9.10.12.1.5.22.1.3 integer read-only
Management field for ACTION. AC INI-Param: SS7_SIG_IF_ID_ACTION Enumeration: 'deActivate': 2, 'none': 0, 'activate': 1.
                         acSS7SigTranIFIDActionResult 1.3.6.1.4.1.5003.9.10.12.1.5.22.1.4 unsigned32 read-only
Management field for ACTION RESULT. AC INI-Param: SS7_SIG_IF_ID_ACTION_RESULT
                         acSS7SigTranIFIDValue 1.3.6.1.4.1.5003.9.10.12.1.5.22.1.5 unsigned32 read-only
SS7 (Signaling System 7) SIGTRAN (Signaling Transport) interface ID value. Access: Online. AC INI-Param: SS7_SIG_IF_ID_VALUE
                         acSS7SigTranIFIDName 1.3.6.1.4.1.5003.9.10.12.1.5.22.1.6 snmpadminstring read-only
SS7 (Signaling System 7) SIGTRAN (Signaling Transport) interface ID name (text string). Access: Online. AC INI-Param: SS7_SIG_IF_ID_NAME
                         acSS7SigTranIFIDOwnerGroup 1.3.6.1.4.1.5003.9.10.12.1.5.22.1.7 integer32 read-only
Owner group of interface id. Access: Online. AC INI-Param: SS7_SIG_IF_ID_OWNER_GROUP
                         acSS7SigTranIFIDSignalingLayer 1.3.6.1.4.1.5003.9.10.12.1.5.22.1.8 integer read-only
UAL Type of interface id: 0 = none 1 = iua 2 = m2ua 4 = m2tunnel 5 = V5ua 6 = dua 7=isdnTunnel. Access: Online. AC INI-Param: SS7_SIG_IF_ID_LAYER Enumeration: 'm2tunnel': 4, 'noLayer': 0, 'iua': 1, 'dua': 6, 'isdnTunnel': 7, 'm2ua': 2.
                         acSS7SigTranIFIDNai 1.3.6.1.4.1.5003.9.10.12.1.5.22.1.9 integer32 read-only
NAI of interface id. Access: Online. AC INI-Param: SS7_SIG_IF_ID_NAI
                         acSS7SigTranIFIDM3UASpc 1.3.6.1.4.1.5003.9.10.12.1.5.22.1.10 unsigned32 read-only
This parameter is used to specify the SIGTRAN (Signaling Transport) M3UA (M3UA - SS7 MTP3-User Adaptation Layer) SPC. Access: Online. AC INI-Param: SS7_SIG_M3UA_SPC
               acSS7M3UAStaticRoutingTable 1.3.6.1.4.1.5003.9.10.12.1.5.23 no-access
                     acSS7M3UAStaticRoutingEntry 1.3.6.1.4.1.5003.9.10.12.1.5.23.1 no-access
                         acSS7M3UAStaticRoutingIndex 1.3.6.1.4.1.5003.9.10.12.1.5.23.1.1 unsigned32 no-access
This parameter is used for the Signaling System 7 (SS7) interface ID index, for a line. AC INI-Param: M3UAROUTINGCLIST_Index
                         acSS7M3UAStaticRoutingRowStatus 1.3.6.1.4.1.5003.9.10.12.1.5.23.1.2 rowstatus read-only
This parameter is used for the Signaling System 7 (SS7) interface ID row status, for a line. AC INI-Param: SS7_SIG_IF_ID_ROWSTATUS
                         acSS7M3UAStaticRoutingAction 1.3.6.1.4.1.5003.9.10.12.1.5.23.1.3 integer read-only
This parameter is used for Signaling System 7 (SS7) SIGTRAN (Signaling Transport) interface ID management, for actions. AC INI-Param: SS7_SIG_IF_ID_ACTION Enumeration: 'deActivate': 2, 'none': 0, 'activate': 1.
                         acSS7M3UAStaticRoutingActionResult 1.3.6.1.4.1.5003.9.10.12.1.5.23.1.4 unsigned32 read-only
This parameter is used for Signaling System 7 (SS7) SIGTRAN (Signaling Transport) interface ID management, for an action's results. AC INI-Param: SS7_SIG_IF_ID_ACTION_RESULT
                         acSS7M3UAStaticRoutingOwnerInterfaceGroup 1.3.6.1.4.1.5003.9.10.12.1.5.23.1.5 unsigned32 read-only
Routing Context list - for M3UA use. Access: Online. AC INI-Param: M3UAROUTINGCLIST_OwnerInterfaceGroup
                         acSS7M3UAStaticRoutingRC 1.3.6.1.4.1.5003.9.10.12.1.5.23.1.6 unsigned32 read-only
Routing Context list - for M3UA use. Access: Online. AC INI-Param: M3UAROUTINGCLIST_RoutingContext
                         acSS7M3UAStaticRoutingDestinationPointCode 1.3.6.1.4.1.5003.9.10.12.1.5.23.1.7 unsigned32 read-only
Routing Context list - for M3UA use. Access: Online. AC INI-Param: M3UAROUTINGCLIST_DestinationPointCode
                         acSS7M3UAStaticRoutingNetworkAppearence 1.3.6.1.4.1.5003.9.10.12.1.5.23.1.8 unsigned32 read-only
Routing Context list - for M3UA use. Access: Online. AC INI-Param: M3UAROUTINGCLIST_NetworkAppearence
                         acSS7M3UAStaticRoutingSeriviceIndicatorList 1.3.6.1.4.1.5003.9.10.12.1.5.23.1.9 unsigned32 read-only
Routing Context list - for M3UA use. Access: Online. AC INI-Param: M3UAROUTINGCLIST_SeriviceIndicatorList
                         acSS7M3UAStaticRoutingOPC1 1.3.6.1.4.1.5003.9.10.12.1.5.23.1.10 unsigned32 read-only
Routing Context list - for M3UA use. Access: Online. AC INI-Param: M3UAROUTINGCLIST_OPC1
                         acSS7M3UAStaticRoutingOPC2 1.3.6.1.4.1.5003.9.10.12.1.5.23.1.11 unsigned32 read-only
Routing Context list - for M3UA use. Access: Online. AC INI-Param: M3UAROUTINGCLIST_OPC2
                         acSS7M3UAStaticRoutingOPC3 1.3.6.1.4.1.5003.9.10.12.1.5.23.1.12 unsigned32 read-only
Routing Context list - for M3UA use. Access: Online. AC INI-Param: M3UAROUTINGCLIST_OPC3
                         acSS7M3UAStaticRoutingOPC4 1.3.6.1.4.1.5003.9.10.12.1.5.23.1.13 unsigned32 read-only
Routing Context list - for M3UA use. Access: Online. AC INI-Param: M3UAROUTINGCLIST_OPC4
                         acSS7M3UAStaticRoutingLowerCICValue1 1.3.6.1.4.1.5003.9.10.12.1.5.23.1.14 unsigned32 read-only
Routing Context list - for M3UA use. Access: Online. AC INI-Param: M3UAROUTINGCLIST_LowerCICValue1
                         acSS7M3UAStaticRoutingUpperCICValue1 1.3.6.1.4.1.5003.9.10.12.1.5.23.1.15 unsigned32 read-only
Routing Context list - for M3UA use. Access: Online. AC INI-Param: M3UAROUTINGCLIST_UpperCICValue1
                         acSS7M3UAStaticRoutingLowerCICValue2 1.3.6.1.4.1.5003.9.10.12.1.5.23.1.16 unsigned32 read-only
Routing Context list - for M3UA use. Access: Online. AC INI-Param: M3UAROUTINGCLIST_LowerCICValue2
                         acSS7M3UAStaticRoutingUpperCICValue2 1.3.6.1.4.1.5003.9.10.12.1.5.23.1.17 unsigned32 read-only
Routing Context list - for M3UA use. Access: Online. AC INI-Param: M3UAROUTINGCLIST_UpperCICValue2
                         acSS7M3UAStaticRoutingLowerCICValue3 1.3.6.1.4.1.5003.9.10.12.1.5.23.1.18 unsigned32 read-only
Routing Context list - for M3UA use. Access: Online. AC INI-Param: M3UAROUTINGCLIST_LowerCICValue3
                         acSS7M3UAStaticRoutingUpperCICValue3 1.3.6.1.4.1.5003.9.10.12.1.5.23.1.19 unsigned32 read-only
Routing Context list - for M3UA use. Access: Online. AC INI-Param: M3UAROUTINGCLIST_UpperCICValue3
                         acSS7M3UAStaticRoutingLowerCICValue4 1.3.6.1.4.1.5003.9.10.12.1.5.23.1.20 unsigned32 read-only
Routing Context list - for M3UA use. Access: Online. AC INI-Param: M3UAROUTINGCLIST_LowerCICValue4
                         acSS7M3UAStaticRoutingUpperCICValue4 1.3.6.1.4.1.5003.9.10.12.1.5.23.1.21 unsigned32 read-only
Routing Context list - for M3UA use. Access: Online. AC INI-Param: M3UAROUTINGCLIST_UpperCICValue4
               acSS7SigTranRoutingContextTable 1.3.6.1.4.1.5003.9.10.12.1.5.24 no-access
                     acSS7SigTranRoutingContextEntry 1.3.6.1.4.1.5003.9.10.12.1.5.24.1 no-access
                         acSS7SigTranRoutingContextIndex 1.3.6.1.4.1.5003.9.10.12.1.5.24.1.1 unsigned32 no-access
First index field for line. AC INI-Param: SS7_RC_INDEX
                         acSS7SigTranRoutingContextInnerIndex 1.3.6.1.4.1.5003.9.10.12.1.5.24.1.2 unsigned32 no-access
Second index field for line. AC INI-Param: SS7_RC_INNER_INDEX
                         acSS7SigTranRoutingContextRowStatus 1.3.6.1.4.1.5003.9.10.12.1.5.24.1.3 rowstatus read-only
ROWSTATUS field for line. AC INI-Param: SS7_RC_ROW_STATUS
                         acSS7SigTranRoutingContextAction 1.3.6.1.4.1.5003.9.10.12.1.5.24.1.4 integer read-only
Management field for ACTIONS. AC INI-Param: RCAction Enumeration: 'deActivate': 2, 'none': 0, 'activate': 1.
                         acSS7SigTranRoutingContextActionResult 1.3.6.1.4.1.5003.9.10.12.1.5.24.1.5 unsigned32 read-only
RCActionRes. AC INI-Param: SS7_RC_ACTION_RES
                         acSS7SigTranRoutingContextSnIdx 1.3.6.1.4.1.5003.9.10.12.1.5.24.1.6 unsigned32 read-only
This parameter is used to specify the M3UA Routing Context DPC SN-Index. Access: Online. AC INI-Param: SS7_RC_SN_INDEX
                         acSS7SigTranRoutingContextSpc 1.3.6.1.4.1.5003.9.10.12.1.5.24.1.7 integer32 read-only
This parameter is used to specify the M3UA Routing Context DPC parameter. AC INI-Param: SS7_RC_SPC
                         acSS7SigTranRoutingContextOpc1 1.3.6.1.4.1.5003.9.10.12.1.5.24.1.8 integer32 read-only
This parameter is used to specify the M3UA Routing Context,First element of OPC list. Access: Online. AC INI-Param: SS7_RC_OPC1
                         acSS7SigTranRoutingContextOpc2 1.3.6.1.4.1.5003.9.10.12.1.5.24.1.9 integer32 read-only
This parameter is used to specify the M3UA Routing Context,Second element of OPC list. Access: Online. AC INI-Param: SS7_RC_OPC2
                         acSS7SigTranRoutingContextOpc3 1.3.6.1.4.1.5003.9.10.12.1.5.24.1.10 integer32 read-only
This parameter is used to specify the M3UA Routing Context, Third element of OPC list. Access: Online. AC INI-Param: SS7_RC_OPC3
                         acSS7SigTranRoutingContextOpc4 1.3.6.1.4.1.5003.9.10.12.1.5.24.1.11 integer32 read-only
This parameter is used to specify the M3UA Routing Context, Fourth element of OPC list. Access: Online. AC INI-Param: SS7_RC_OPC4
                         acSS7SigTranRoutingContextSi1 1.3.6.1.4.1.5003.9.10.12.1.5.24.1.12 integer32 read-only
This parameter is used to specify the M3UA Routing Context, First element of SI list. Access: Online. AC INI-Param: SS7_RC_SI1
                         acSS7SigTranRoutingContextSi2 1.3.6.1.4.1.5003.9.10.12.1.5.24.1.13 integer32 read-only
This parameter is used to specify the M3UA Routing Context, Second element of SI list. Access: Online. AC INI-Param: SS7_RC_SI2
                         acSS7SigTranRoutingContextSi3 1.3.6.1.4.1.5003.9.10.12.1.5.24.1.14 integer32 read-only
This parameter is used to specify the M3UA Routing Context, Third element of SI list. Access: Online. AC INI-Param: SS7_RC_SI3
                         acSS7SigTranRoutingContextSi4 1.3.6.1.4.1.5003.9.10.12.1.5.24.1.15 integer32 read-only
This parameter is used to specify the M3UA Routing Context, Fourth element of SI list. Access: Online. AC INI-Param: SS7_RC_SI4
           acSS7Redundancy 1.3.6.1.4.1.5003.9.10.12.1.6
               acSS7RedundancyCrossLinkTransferType 1.3.6.1.4.1.5003.9.10.12.1.6.1 integer read-write
Defines the cross-board connection media type for the MTP3 redundancy feature: 0 = M3BRDCY_CONN_TYPE_NONE 2 = M3BRDCY_CONN_TYPE_TCP. Access: Offline. AC INI-Param: SS7MTP3RdcyTransferType Enumeration: 'none': 0, 'tcp': 2.
               acSS7RedundancyMode 1.3.6.1.4.1.5003.9.10.12.1.6.2 integer read-write
Defines the MTP3 Signaling redundancy mode: 0 = Disabled 1 = Enabled . Access: Offline. AC INI-Param: SS7MTP3RdcyMode Enumeration: 'enable': 1, 'disable': 0.
               acSS7RedundancyBoardNum 1.3.6.1.4.1.5003.9.10.12.1.6.3 unsigned32 read-write
Defines the board number for the SS7 (Signaling System 7) MTP3 redundancy mode. Each board is allocated a unique number. All boards share a single redundancy table. Access: Offline. AC INI-Param: SS7MTP3RdcyBoardNum
               acSS7RedundancyCrossLinkTraceAll 1.3.6.1.4.1.5003.9.10.12.1.6.4 integer read-write
When set via INI-file, activates trace output for all X-links (only when SS7 redundancy is configured). . Access: Instant. AC INI-Param: SS7M3BRdcyXlinkTraceAll Enumeration: 'enable': 1, 'disable': 0.
               acSS7RedundancyMTP3RdcyTblSyncInterval 1.3.6.1.4.1.5003.9.10.12.1.6.5 unsigned32 read-write
Defines the interval between SS7 tables automatic synchronizations, in minutes. 0 = no automatic synchronization is activated. . Access: Instant. AC INI-Param: N/A
               acSS7RedundancySyncAllBoards 1.3.6.1.4.1.5003.9.10.12.1.6.6 integer read-write
Provide SYNC all boards command. Access: Instant. AC INI-Param: N/A Enumeration: 'sync': 1, 'noAction': 0.
               acSS7RedundancySyncBoard 1.3.6.1.4.1.5003.9.10.12.1.6.7 unsigned32 read-write
Provide SYNC between this board and another specific board (parameter is the remote board number). Access: Instant. AC INI-Param: N/A
               acSS7RedundancyKeepAliveWindow 1.3.6.1.4.1.5003.9.10.12.1.6.8 unsigned32 read-write
Defines redundancy X-link keep-alive tolerance window. (x-link between boards in Signaling System 7 (SS7) MTP3-User Adaptation Layer redundancy mode). . Access: Offline. AC INI-Param: SS7MTP3RdcyKeepAliveWindow
               acSS7RedundancyKeepAliveInterval 1.3.6.1.4.1.5003.9.10.12.1.6.9 unsigned32 read-write
Defines redundancy X-link keep-alive interval in secs. (x-link between boards in Signaling System 7 (SS7) MTP3-User Adaptation Layer redundancy mode). 0 = no keep-alive mechanism is activated. . Access: Offline. AC INI-Param: SS7MTP3RdcyKeepAliveInterval
               acSS7RedundantSNTable 1.3.6.1.4.1.5003.9.10.12.1.6.21 no-access
                     acSS7RedundantSNEntry 1.3.6.1.4.1.5003.9.10.12.1.6.21.1 no-access
                         acSS7RedundantSNBoardIndex 1.3.6.1.4.1.5003.9.10.12.1.6.21.1.1 unsigned32 no-access
First index for a line: board number. AC INI-Param: SS7_RDCYSN_BOARD_INDEX
                         acSS7RedundantSNIndex 1.3.6.1.4.1.5003.9.10.12.1.6.21.1.2 unsigned32 no-access
Second index for a line: SN number in the board. AC INI-Param: SS7_RDCYSN_SN_INDEX
                         acSS7RedundantSNRowStatus 1.3.6.1.4.1.5003.9.10.12.1.6.21.1.3 rowstatus read-only
ROWSTATUS field for line. AC INI-Param: SS7_RDCYSN_ROWSTATUS
                         acSS7RedundantSNAction 1.3.6.1.4.1.5003.9.10.12.1.6.21.1.4 unsigned32 read-only
Management field for ACTION. AC INI-Param: SS7_RDCYSN_ACTION
                         acSS7RedundantSNActionRes 1.3.6.1.4.1.5003.9.10.12.1.6.21.1.5 unsigned32 read-only
Management field for ACTION RESULT. AC INI-Param: SS7_RDCYSN_ACTIONRES
                         acSS7RedundantSNBoardIp 1.3.6.1.4.1.5003.9.10.12.1.6.21.1.6 ipaddress read-only
IP address of the board. Access: Online. AC INI-Param: SS7_RDCYSN_BOARD_IP
                         acSS7RedundantSNOPC 1.3.6.1.4.1.5003.9.10.12.1.6.21.1.7 unsigned32 read-only
Internal point-code of the SN (Signaling Node). Access: Online. AC INI-Param: SS7_RDCYSN_OPC
                         acSS7RedundantSNALCAPOPC 1.3.6.1.4.1.5003.9.10.12.1.6.21.1.8 unsigned32 read-only
Internal point-code of ALCAP instance on a given board. Access: Online. AC INI-Param: SS7_RDCYSN_ALCAP_OPC
       acSS7Status 1.3.6.1.4.1.5003.9.10.12.2
           acSS7Constants 1.3.6.1.4.1.5003.9.10.12.2.1
               acSS7ConstantsNumberOfNodes 1.3.6.1.4.1.5003.9.10.12.2.1.1 unsigned32 read-only
AC INI-Param: N/A
               acSS7ConstantsNumberOfLinks 1.3.6.1.4.1.5003.9.10.12.2.1.2 unsigned32 read-only
AC INI-Param: N/A
               acSS7ConstantsNumberOfLinkSetsPerSN 1.3.6.1.4.1.5003.9.10.12.2.1.3 unsigned32 read-only
AC INI-Param: N/A
               acSS7ConstantsNumberOfLinksPerLinkSet 1.3.6.1.4.1.5003.9.10.12.2.1.4 unsigned32 read-only
AC INI-Param: N/A
               acSS7ConstantsNumberOfRouteSetsPerSN 1.3.6.1.4.1.5003.9.10.12.2.1.5 unsigned32 read-only
AC INI-Param: N/A
               acSS7ConstantsNumberOfRoutesPerRouteSets 1.3.6.1.4.1.5003.9.10.12.2.1.6 unsigned32 read-only
AC INI-Param: N/A
               acSS7ConstantsNumberOfNodeTimerSets 1.3.6.1.4.1.5003.9.10.12.2.1.7 unsigned32 read-only
AC INI-Param: N/A
               acSS7ConstantsNumberOfLinkSetTimerSets 1.3.6.1.4.1.5003.9.10.12.2.1.8 unsigned32 read-only
AC INI-Param: N/A