AC-PM-ATM-MIB: View SNMP OID List / Download MIB
VENDOR: AUDIOCODES LTD
Home | MIB: AC-PM-ATM-MIB | |||
---|---|---|---|---|
Download as: |
Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
|
|||
Object Name | OID | Type | Access | Info |
audioCodes | 1.3.6.1.4.1.5003 | |||
acRegistrations | 1.3.6.1.4.1.5003.7 | |||
acGeneric | 1.3.6.1.4.1.5003.8 | |||
acProducts | 1.3.6.1.4.1.5003.9 | |||
acPerformance | 1.3.6.1.4.1.5003.10 | |||
acPMAtm | 1.3.6.1.4.1.5003.10.12 |
The AC-PM-ATM MIB offers performance monitoring For the ATMrelated elements in Audiocodes' devices. The Configuration sub-tree is for configuring the interval Period length for the entire AC-PM-ATM MIB, and the different tables' thresholds. The Data sub-tree presents the tables of monitored elements. Note - for the entire MIB the value (-1) means the value Asked for is either not supported or currently not relevant (this is for when values asked for are for intervals not yet recorded. |
||
acPMAtmConfiguration | 1.3.6.1.4.1.5003.10.12.1 | |||
acPMAtmConfigurationPeriodLength | 1.3.6.1.4.1.5003.10.12.1.1 | integer | read-write |
Length of monitoring intervals for entire MIB.Time is in minutes. |
acPMAtmConfigurationResetTotalCounters | 1.3.6.1.4.1.5003.10.12.1.2 | integer | read-write |
Total-Counters Reset. To reset the total counters, set the value of this object to resetTotalCounters(2). Enumeration: 'resetTotalCounters': 2, 'resetCountersDone': 1. |
acPMAtmCellAttributes | 1.3.6.1.4.1.5003.10.12.1.31 | |||
acPMAtmCellAttributesTxHighThreshold | 1.3.6.1.4.1.5003.10.12.1.31.1 | integer | read-write |
High threshold. |
acPMAtmCellAttributesTxLowThreshold | 1.3.6.1.4.1.5003.10.12.1.31.2 | integer | read-write |
Low threshold. |
acPMAtmCellAttributesRxHighThreshold | 1.3.6.1.4.1.5003.10.12.1.31.3 | integer | read-write |
High threshold. |
acPMAtmCellAttributesRxLowThreshold | 1.3.6.1.4.1.5003.10.12.1.31.4 | integer | read-write |
Low threshold. |
acPMAtmData | 1.3.6.1.4.1.5003.10.12.2 | |||
acPMAtmDataAcPMAtmTimeFromStartOfInterval | 1.3.6.1.4.1.5003.10.12.2.1 | integer | read-only |
The time in seconds since the start of the current interval. MIB specific. |
acPMAtmCellTxTable | 1.3.6.1.4.1.5003.10.12.2.21 | no-access |
Atm interface transmit cells per second. |
|
1.3.6.1.4.1.5003.10.12.2.21.1 | no-access | |||
acPMAtmCellTxInterface | 1.3.6.1.4.1.5003.10.12.2.21.1.1 | integer | no-access |
Atm interface 0,1 and 2. |
acPMAtmCellTxInterval | 1.3.6.1.4.1.5003.10.12.2.21.1.2 | integer | no-access |
Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last. |
acPMAtmCellTxAverage | 1.3.6.1.4.1.5003.10.12.2.21.1.3 | integer | read-only |
Average value within the period time. |
acPMAtmCellTxMax | 1.3.6.1.4.1.5003.10.12.2.21.1.4 | integer | read-only |
Maximum value within the period time. |
acPMAtmCellTxMin | 1.3.6.1.4.1.5003.10.12.2.21.1.5 | integer | read-only |
Minimum value within the period time. |
acPMAtmCellTxVolume | 1.3.6.1.4.1.5003.10.12.2.21.1.6 | counter32 | read-only |
Activity volume. |
acPMAtmCellTxTimeBelowLowThreshold | 1.3.6.1.4.1.5003.10.12.2.21.1.7 | integer | read-only |
Percent of interval time for which gauge is below what was determined as the low threshold. |
acPMAtmCellTxTimeBetweenThresholds | 1.3.6.1.4.1.5003.10.12.2.21.1.8 | integer | read-only |
Percent of interval time for which gauge is above what was determined as the high threshold. |
acPMAtmCellTxTimeAboveHighThreshold | 1.3.6.1.4.1.5003.10.12.2.21.1.9 | integer | read-only |
Percent of interval time for which gauge is between what were determined as the low and high thresholds. |
acPMAtmCellTxFullDayAverage | 1.3.6.1.4.1.5003.10.12.2.21.1.10 | integer | read-only |
The average of full 24 hours. |
acPMAtmCellRxTable | 1.3.6.1.4.1.5003.10.12.2.22 | no-access |
Atm interface recieve cells per second. |
|
1.3.6.1.4.1.5003.10.12.2.22.1 | no-access | |||
acPMAtmCellRxInterface | 1.3.6.1.4.1.5003.10.12.2.22.1.1 | integer | no-access |
Atm interface 0,1 and 2. |
acPMAtmCellRxInterval | 1.3.6.1.4.1.5003.10.12.2.22.1.2 | integer | no-access |
Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last. |
acPMAtmCellRxAverage | 1.3.6.1.4.1.5003.10.12.2.22.1.3 | integer | read-only |
Average value within the period time. |
acPMAtmCellRxMax | 1.3.6.1.4.1.5003.10.12.2.22.1.4 | integer | read-only |
Maximum value within the period time. |
acPMAtmCellRxMin | 1.3.6.1.4.1.5003.10.12.2.22.1.5 | integer | read-only |
Minimum value within the period time. |
acPMAtmCellRxVolume | 1.3.6.1.4.1.5003.10.12.2.22.1.6 | counter32 | read-only |
Activity volume. |
acPMAtmCellRxTimeBelowLowThreshold | 1.3.6.1.4.1.5003.10.12.2.22.1.7 | integer | read-only |
Percent of interval time for which gauge is below what was determined as the low threshold. |
acPMAtmCellRxTimeBetweenThresholds | 1.3.6.1.4.1.5003.10.12.2.22.1.8 | integer | read-only |
Percent of interval time for which gauge is above what was determined as the high threshold. |
acPMAtmCellRxTimeAboveHighThreshold | 1.3.6.1.4.1.5003.10.12.2.22.1.9 | integer | read-only |
Percent of interval time for which gauge is between what were determined as the low and high thresholds. |
acPMAtmCellRxFullDayAverage | 1.3.6.1.4.1.5003.10.12.2.22.1.10 | integer | read-only |
The average of full 24 hours. |
acPMAtmCellDiscardedTable | 1.3.6.1.4.1.5003.10.12.2.23 | no-access |
Counts the number of cells discarded in the reporting interval. |
|
1.3.6.1.4.1.5003.10.12.2.23.1 | no-access | |||
acPMAtmCellDiscardedInterface | 1.3.6.1.4.1.5003.10.12.2.23.1.1 | integer | no-access |
Atm interface 0,1 and 2. |
acPMAtmCellDiscardedInterval | 1.3.6.1.4.1.5003.10.12.2.23.1.2 | integer | no-access |
Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last. |
acPMAtmCellDiscardedVal | 1.3.6.1.4.1.5003.10.12.2.23.1.3 | gauge32 | read-only |
Value of gauge or counter. |