AC-PM-ATM-MIB: View SNMP OID List / Download MIB

VENDOR: AUDIOCODES LTD


 Home MIB: AC-PM-ATM-MIB
Download as:   

Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
 audioCodes 1.3.6.1.4.1.5003
           acRegistrations 1.3.6.1.4.1.5003.7
           acGeneric 1.3.6.1.4.1.5003.8
           acProducts 1.3.6.1.4.1.5003.9
           acPerformance 1.3.6.1.4.1.5003.10
                 acPMAtm 1.3.6.1.4.1.5003.10.12
The AC-PM-ATM MIB offers performance monitoring For the ATMrelated elements in Audiocodes' devices. The Configuration sub-tree is for configuring the interval Period length for the entire AC-PM-ATM MIB, and the different tables' thresholds. The Data sub-tree presents the tables of monitored elements. Note - for the entire MIB the value (-1) means the value Asked for is either not supported or currently not relevant (this is for when values asked for are for intervals not yet recorded.
                       acPMAtmConfiguration 1.3.6.1.4.1.5003.10.12.1
                           acPMAtmConfigurationPeriodLength 1.3.6.1.4.1.5003.10.12.1.1 integer read-write
Length of monitoring intervals for entire MIB.Time is in minutes.
                           acPMAtmConfigurationResetTotalCounters 1.3.6.1.4.1.5003.10.12.1.2 integer read-write
Total-Counters Reset. To reset the total counters, set the value of this object to resetTotalCounters(2). Enumeration: 'resetTotalCounters': 2, 'resetCountersDone': 1.
                           acPMAtmCellAttributes 1.3.6.1.4.1.5003.10.12.1.31
                                 acPMAtmCellAttributesTxHighThreshold 1.3.6.1.4.1.5003.10.12.1.31.1 integer read-write
High threshold.
                                 acPMAtmCellAttributesTxLowThreshold 1.3.6.1.4.1.5003.10.12.1.31.2 integer read-write
Low threshold.
                                 acPMAtmCellAttributesRxHighThreshold 1.3.6.1.4.1.5003.10.12.1.31.3 integer read-write
High threshold.
                                 acPMAtmCellAttributesRxLowThreshold 1.3.6.1.4.1.5003.10.12.1.31.4 integer read-write
Low threshold.
                       acPMAtmData 1.3.6.1.4.1.5003.10.12.2
                           acPMAtmDataAcPMAtmTimeFromStartOfInterval 1.3.6.1.4.1.5003.10.12.2.1 integer read-only
The time in seconds since the start of the current interval. MIB specific.
                           acPMAtmCellTxTable 1.3.6.1.4.1.5003.10.12.2.21 no-access
Atm interface transmit cells per second.
                                 acPMAtmCellTxEntry 1.3.6.1.4.1.5003.10.12.2.21.1 no-access
                                     acPMAtmCellTxInterface 1.3.6.1.4.1.5003.10.12.2.21.1.1 integer no-access
Atm interface 0,1 and 2.
                                     acPMAtmCellTxInterval 1.3.6.1.4.1.5003.10.12.2.21.1.2 integer no-access
Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last.
                                     acPMAtmCellTxAverage 1.3.6.1.4.1.5003.10.12.2.21.1.3 integer read-only
Average value within the period time.
                                     acPMAtmCellTxMax 1.3.6.1.4.1.5003.10.12.2.21.1.4 integer read-only
Maximum value within the period time.
                                     acPMAtmCellTxMin 1.3.6.1.4.1.5003.10.12.2.21.1.5 integer read-only
Minimum value within the period time.
                                     acPMAtmCellTxVolume 1.3.6.1.4.1.5003.10.12.2.21.1.6 counter32 read-only
Activity volume.
                                     acPMAtmCellTxTimeBelowLowThreshold 1.3.6.1.4.1.5003.10.12.2.21.1.7 integer read-only
Percent of interval time for which gauge is below what was determined as the low threshold.
                                     acPMAtmCellTxTimeBetweenThresholds 1.3.6.1.4.1.5003.10.12.2.21.1.8 integer read-only
Percent of interval time for which gauge is above what was determined as the high threshold.
                                     acPMAtmCellTxTimeAboveHighThreshold 1.3.6.1.4.1.5003.10.12.2.21.1.9 integer read-only
Percent of interval time for which gauge is between what were determined as the low and high thresholds.
                                     acPMAtmCellTxFullDayAverage 1.3.6.1.4.1.5003.10.12.2.21.1.10 integer read-only
The average of full 24 hours.
                           acPMAtmCellRxTable 1.3.6.1.4.1.5003.10.12.2.22 no-access
Atm interface recieve cells per second.
                                 acPMAtmCellRxEntry 1.3.6.1.4.1.5003.10.12.2.22.1 no-access
                                     acPMAtmCellRxInterface 1.3.6.1.4.1.5003.10.12.2.22.1.1 integer no-access
Atm interface 0,1 and 2.
                                     acPMAtmCellRxInterval 1.3.6.1.4.1.5003.10.12.2.22.1.2 integer no-access
Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last.
                                     acPMAtmCellRxAverage 1.3.6.1.4.1.5003.10.12.2.22.1.3 integer read-only
Average value within the period time.
                                     acPMAtmCellRxMax 1.3.6.1.4.1.5003.10.12.2.22.1.4 integer read-only
Maximum value within the period time.
                                     acPMAtmCellRxMin 1.3.6.1.4.1.5003.10.12.2.22.1.5 integer read-only
Minimum value within the period time.
                                     acPMAtmCellRxVolume 1.3.6.1.4.1.5003.10.12.2.22.1.6 counter32 read-only
Activity volume.
                                     acPMAtmCellRxTimeBelowLowThreshold 1.3.6.1.4.1.5003.10.12.2.22.1.7 integer read-only
Percent of interval time for which gauge is below what was determined as the low threshold.
                                     acPMAtmCellRxTimeBetweenThresholds 1.3.6.1.4.1.5003.10.12.2.22.1.8 integer read-only
Percent of interval time for which gauge is above what was determined as the high threshold.
                                     acPMAtmCellRxTimeAboveHighThreshold 1.3.6.1.4.1.5003.10.12.2.22.1.9 integer read-only
Percent of interval time for which gauge is between what were determined as the low and high thresholds.
                                     acPMAtmCellRxFullDayAverage 1.3.6.1.4.1.5003.10.12.2.22.1.10 integer read-only
The average of full 24 hours.
                           acPMAtmCellDiscardedTable 1.3.6.1.4.1.5003.10.12.2.23 no-access
Counts the number of cells discarded in the reporting interval.
                                 acPMAtmCellDiscardedEntry 1.3.6.1.4.1.5003.10.12.2.23.1 no-access
                                     acPMAtmCellDiscardedInterface 1.3.6.1.4.1.5003.10.12.2.23.1.1 integer no-access
Atm interface 0,1 and 2.
                                     acPMAtmCellDiscardedInterval 1.3.6.1.4.1.5003.10.12.2.23.1.2 integer no-access
Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last.
                                     acPMAtmCellDiscardedVal 1.3.6.1.4.1.5003.10.12.2.23.1.3 gauge32 read-only
Value of gauge or counter.