{
  "imports": {
    "class": "imports",
    "RADLAN-MIB": [
      "rnd"
    ],
    "SNMPv2-CONF": [
      "NOTIFICATION-GROUP",
      "MODULE-COMPLIANCE"
    ],
    "SNMPv2-SMI": [
      "Bits",
      "MibIdentifier",
      "Unsigned32",
      "NOTIFICATION-TYPE",
      "Integer32",
      "MODULE-IDENTITY",
      "OBJECT-IDENTITY",
      "OBJECT-TYPE",
      "iso",
      "IpAddress",
      "Counter64",
      "Gauge32",
      "TimeTicks",
      "Counter32"
    ],
    "SNMPv2-TC": [
      "DisplayString",
      "TEXTUAL-CONVENTION"
    ]
  },
  "rlRs232": {
    "name": "rlRs232",
    "oid": "1.3.6.1.4.1.89.104",
    "class": "moduleidentity",
    "revisions": [
      {
        "revision": "2005-04-14 00:00",
        "description": "Initial revision."
      }
    ],
    "lastupdated": "200504140000Z",
    "organization": "Radlan Computer Communications Ltd.",
    "contactinfo": "radlan.com",
    "description": "The private MIB module definition for baudrate."
  },
  "rlRs232MibVersion": {
    "name": "rlRs232MibVersion",
    "oid": "1.3.6.1.4.1.89.104.1",
    "nodetype": "scalar",
    "class": "objecttype",
    "syntax": {
      "type": "INTEGER",
      "class": "type"
    },
    "maxaccess": "read-only",
    "status": "current",
    "description": "MIB's version, the current version is 1."
  },
  "rlRs232AutoBaudRateStatus": {
    "name": "rlRs232AutoBaudRateStatus",
    "oid": "1.3.6.1.4.1.89.104.2",
    "nodetype": "scalar",
    "class": "objecttype",
    "syntax": {
      "type": "INTEGER",
      "class": "type",
      "constraints": {
        "enumeration": {
          "enable": 1,
          "disable": 2
        }
      }
    },
    "maxaccess": "read-only",
    "status": "current",
    "description": "Show the current Auto BaudRate status"
  },
  "rlRs232AutoBaudRateStatusAfterReset": {
    "name": "rlRs232AutoBaudRateStatusAfterReset",
    "oid": "1.3.6.1.4.1.89.104.3",
    "nodetype": "scalar",
    "class": "objecttype",
    "syntax": {
      "type": "INTEGER",
      "class": "type",
      "constraints": {
        "enumeration": {
          "enable": 1,
          "disable": 2
        }
      }
    },
    "maxaccess": "read-write",
    "status": "current",
    "description": "Show/Set the Auto BaudRate status after reset"
  },
  "rlRs232BaudRate": {
    "name": "rlRs232BaudRate",
    "oid": "1.3.6.1.4.1.89.104.4",
    "nodetype": "scalar",
    "class": "objecttype",
    "syntax": {
      "type": "INTEGER",
      "class": "type",
      "constraints": {
        "enumeration": {
          "baud2400": 1,
          "baud4800": 2,
          "baud9600": 3,
          "baud19200": 4,
          "baud38400": 5,
          "baud57600": 6,
          "baud115200": 7
        }
      }
    },
    "maxaccess": "read-write",
    "status": "current",
    "description": "Show/Set the current Baud Rate status"
  },
  "meta": {
    "comments": [
      "ASN.1 source file:///Users/neermitt/kusanagi/mibs.snmplabs.com/asn1/RADLAN-BaudRate-MIB",
      "Produced by pysmi-0.3.4 at Fri May 24 21:06:34 2019",
      "On host NEERMITT-M-J0NV platform Darwin version 18.6.0 by user neermitt",
      "Using Python version 3.7.3 (default, Mar 27 2019, 09:23:15) "
    ],
    "module": "RADLAN-BaudRate-MIB"
  }
}