Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
 lanex 1.3.6.1.4.1.5746
           telecom 1.3.6.1.4.1.5746.1
               optiLine4 1.3.6.1.4.1.5746.1.1
Tok_String
                   main 1.3.6.1.4.1.5746.1.1.1
                       mainDeviceName 1.3.6.1.4.1.5746.1.1.1.1
Nazwa urzadzenia (tekst - 16 znakow)
                       mainDeviceDescription 1.3.6.1.4.1.5746.1.1.1.2
Tekstowy opis urzadzenia (tekst - 16 znakow)
                       mainDeviceType 1.3.6.1.4.1.5746.1.1.1.3
Typ urzadzenia: 44 - TM-44 49 - TM-60 60 - TM-60 61 - TM-61 62 - OptiLine 4 (TM-62) 63 - OptiLine 16 (TM-63)
                       mainHardwareVersion 1.3.6.1.4.1.5746.1.1.1.4
Wersja produkcyjna urzadzenia (np.TM-62.x ,gdzie x-wersja produkcyjna
                       mainLNMPAddress 1.3.6.1.4.1.5746.1.1.1.5
Adres urzdzenia wykorzystany w protokole LNMP dla LanWin
                       mainDevicePhysicalNumber 1.3.6.1.4.1.5746.1.1.1.6
Numer fabryczny urzadzenia
                       mainDeviceSoftwareVersion 1.3.6.1.4.1.5746.1.1.1.7
Wersja kodu ukladu programowalnego np. 101 oznacza wersje 1.01
                       mainSoftwareVersion 1.3.6.1.4.1.5746.1.1.1.8
Wersja oprogramowania np. wartosc 101 oznacza wersje 1.01
                       mainPasswordActivity 1.3.6.1.4.1.5746.1.1.1.9
Aktywacja hasa dostepu do urzdzenia: 0 - haso nieaktywne 1- haso aktywne
                       mainPassword 1.3.6.1.4.1.5746.1.1.1.10
Haslo dostepu do urzadzenia
                       mainDateTime 1.3.6.1.4.1.5746.1.1.1.11
Data i czas systemowy
                   configuration 1.3.6.1.4.1.5746.1.1.2
                       confLOES 1.3.6.1.4.1.5746.1.1.2.1
Zalaczanie/blokowanie kanalow skladowych 1-4 Rejestr ZKS jest 8 bitowy i ustawienie poszczegolnych bitow od bitu nr 0 do 3 na wartooeae 1 powoduje zalonczenie, a ustawienie na 0 wylonczenie odpowiednio kanalu 1-4. bit : 3 2 1 0 nazwa : ZKS4 ZKS3 ZKS2 ZKS1
                       confAlarmConfirm 1.3.6.1.4.1.5746.1.1.2.3
Kasowanie (potwierdzanie) alarmu 1- kasowanie
                       confTransmitterType 1.3.6.1.4.1.5746.1.1.2.4
Typ nadajnika bloku zbiorczego: 0-dioda laserowa, 1-dioda LED
                       confTransmitterStatus 1.3.6.1.4.1.5746.1.1.2.5
Ustawienie nadajnika laserowego: 0-wylaczony/automatyka, 1-pelna moc, 2-obnizona moc
                       confProgMAXTemperature 1.3.6.1.4.1.5746.1.1.2.6
Gorny dopuszczalny poziom temperatury w systemie (wartooeae np. 2758 oznacza temperature 27.58 stopni C)
                       confProgMINTemperature 1.3.6.1.4.1.5746.1.1.2.7
Dolny dopuszczalny poziom temperatury w systemie (wartooeae np. 2758 oznacza temperature 27.58 stopni C)
                       confProgMAX5V 1.3.6.1.4.1.5746.1.1.2.10
Gorny dopuszczalny poziom napiecia 5V (wartooeae np. 527 oznacza napiecie 5.27 V)
                       confProgMIN5V 1.3.6.1.4.1.5746.1.1.2.11
Dolny dopuszczalny poziom napiecia 5V (wartooeae np. 527 oznacza napiecie 5.27 V)
                       confProgMAX12V 1.3.6.1.4.1.5746.1.1.2.12
Gorny dopuszczalny poziom napiecia 12V (wartooeae np. 1227 oznacza napiecie 12.27 V)
                       confProgMIN12V 1.3.6.1.4.1.5746.1.1.2.13
Dolny dopuszczalny poziom napiecia 12V (wartooeae np. 1227 oznacza napiecie 12.27 V)
                       confProgMAXM12V 1.3.6.1.4.1.5746.1.1.2.14
Gorny dopuszczalny poziom napiecia -12V (wartooeae np. 1227 oznacza napiecie -12.27 V)
                       confProgMINM12V 1.3.6.1.4.1.5746.1.1.2.15
Dolny dopuszczalny poziom napiecia -12V (wartooeae np. 1227 oznacza napiecie -12.27 V)
                   status 1.3.6.1.4.1.5746.1.1.3
                       statLOES 1.3.6.1.4.1.5746.1.1.3.1
Stan rejestru Sygnalow Skladowych 1-4 Zanik sygnau skadowego przychodzcego do wejoecia (ZSSx=1 - zanik sygnau, ZSSx=0 - sygna obecny, gdzie: x - numer kanalu). bit : 3 2 1 0 nazwa : ZSS4 ZSS3 ZSS2 ZSS1
                       statAISLM 1.3.6.1.4.1.5746.1.1.3.2
Stan rejestru Sygnalow AIS Lokalnych 1-4 Odbior sygnau AIS przez urzdzenie lokalne na wejoeciu (AISLx=1 - urzdzenie odbiera sygna AIS, AISLx=0 - brak sygnau AIS, gdzie: x - numer kanalu). bit : 3 2 1 0 nazwa : AISL4 AISL3 AISL2 AISL1
                       statAISRM 1.3.6.1.4.1.5746.1.1.3.3
Stan rejestru Sygnalow AIS Zdalnych 1-4 Odbior sygnau AIS przez urzdzenie lokalne na wejoeciu (AISZx=1 - urzdzenie odbiera sygna AIS, AISZx=0 - brak sygnau AIS, gdzie: x - numer kanalu). bit : 3 2 1 0 nazwa : AISZ4 AISZ3 AISZ2 AISZ1
                       statVIOL 1.3.6.1.4.1.5746.1.1.3.4
Stan rejestru Blad Wiolacji Sygnalu Skladowego 1-4 (BWSSx=1 - jest blad na kanale x, BWSSx=0 - brak bledu na kanale x, gdzie: x - numer kanalu). bit : 3 2 1 0 nazwa : BWSS4 BWSS3 BWSS2 BWSS1
                       statBZSTAT 1.3.6.1.4.1.5746.1.1.3.5
Stan rejestru Status Bloku Zbiorczego BZSTAT jest rejestrem 8 bitowym. Znaczenie jego bitow: bit 5: ALZUZ-Alarm Zwrotny Z Urzdzenia Zdalnego (ALZUZ=1 - urzdzenie otrzymao sygna alarmu zwrotnego, ALZUZ=0 - brak sygnau alarmu zwrotnego). bit 4: 106K - Przekroczenie stopy 10-6 bedow kodowych w odebranym sygnale zbiorczym (E10_6=1 - nastpio przekroczenie, E10_6=0 - przekroczenie nie nastpio). bit 3: 103K - Przekroczenie stopy 10-3 bedow kodowych w odebranym sygnale zbiorczym (E10_3=1 - nastpio przekroczenie, E10_3=0 - przekroczenie nie nastpio). bit 2: USR - Utrata Synchronizacji Ramki bit 1: ZMN - Zanik Mocy Nadajnika (0 moc poprawna, 1 moc niepoprawna) bit 0: ZSO - Zanik Sygnau Optycznego na wejoeciu oewiatowodowym
                       statSUS 1.3.6.1.4.1.5746.1.1.3.6
Stan rejestru Status Ukladu Sygnalizacji Bity sygnalizacji alarmow: bit 0: DALP - bit sygnalizacji alarmu pilnego lub zaniku alarmu po potwierdzeniu bit 1: DPALP - bit sygnalizacji przypomnienia alarmu pilnego bit 2: PALP - bit zaczenia przekaYnika alarmu pilnego bit 3: DALN - bit sygnalizacji alarmu niepilnego lub zaniku alarmu po potwierdzeniu bit 4: DPALN - bit sygnalizacji przypomnienia alarmu niepilnego bit 5: PALN - bit zaczenia przekaYnika alarmu niepilnego
                       statKJT 1.3.6.1.4.1.5746.1.1.3.7
Stan rejestru Kontrola Jakosci Transmisji Bity rejestru: bit 7: PSES24O - Wystpienie przekroczenia wartooeci progowej dla rejestru SES,24 godzinnego, dla kierunku odbiorczego (PSES24O=1 - nastpio przekroczenie, PSES24O=0 - przekroczenie nie nastpio) bit 6: PSES24N - Wstpienie przekroczenia wartooeci progowej dla rejestru SES, 24 godzinnego, dla kierunku nadawczego (PSES24N=1 - nastpio przekroczenie, PSES24N=0 - przekroczenie nie nastpio) bit 5: PES24O - Wystpienie przekroczenia wartooeci progowej dla rejestru ES, 24 godzinnego, dla kierunku odbiorczego (PES24O=1 - nastpio przekroczenie, PES24O=0 - przekroczenie nie nastpio) bit 4: PES24N - Wystpienie przekroczenia wartooeci progowej dla rejestru ES, 24 godzinnego, dla kierunku nadawczego (PES24N=1 - nastpio przekroczenie, PES24N=0 - przekroczenie nie nastpio) bit 3: PSES15O - Wystpienie przekroczenia wartooeci progowej dla rejestru SES, 15 minutowego, dla kierunku odbiorczego (PSES15O=1 - nastpio przekroczenie, PSES15O=0 - przekroczenie nie nastpio) bit 2: PSES15N - Wystpienie przekroczenia wartooeci progowej dla rejestru SES, 15 minutowego, dla kierunku nadawczego (PSES15N=1 - nastpio przekroczenie, PSES15N=0 - przekroczenie nie nastpio) bit 1: PES15O - Wystpienie przekroczenia wartooeci progowej dla rejestru ES, 15 minutowego, dla kierunku odbiorczego (PES15O=1 - nastpio przekroczenie, PES15O=0 - przekroczenie nie nastpio) bit 0: PES15N - Wystpienie przekroczenia wartooeci progowej dla rejestru ES, 15 minutowego, dla kierunku nadawczego (PES15N=1 - nastpio przekroczenie, PES15N=0 - przekroczenie nie nastpio)
                       statTemperature 1.3.6.1.4.1.5746.1.1.3.8
Temperatura otoczenia systemu (wartooeae np. 2758 oznacza temperature 27.58 stopni C)
                       stat5VVoltage 1.3.6.1.4.1.5746.1.1.3.10
Napiecie zasilania 5V (wartooeae np. 527 oznacza napiecie 5.27 V)
                       stat12VVoltage 1.3.6.1.4.1.5746.1.1.3.11
Napiecie zasilania 12V (wartooeae np. 1227 oznacza napiecie 12.27 V)
                       statM12VVoltage 1.3.6.1.4.1.5746.1.1.3.12
Napiecie zasilania -12V (wartooeae np. 1227 oznacza napiecie -12.27 V)
                       statExtremLevel 1.3.6.1.4.1.5746.1.1.3.13
Stan napieae zasilajcych i temperatury otoczenia. Poszczegolne bity oznaczaj przekroczenie wartooeci dopuszczalnej (progowej): (1 - przekroczenie wartosci progowej, 0 - wrtosc ponizej ustawionego progu) bit 1: - napiecia 5V bit 2: - napiecia 12V bit 3: - napiecia -12V bit 7: - temperatury otoczenia
                   eventLog 1.3.6.1.4.1.5746.1.1.4
                       logIndexLastEvent 1.3.6.1.4.1.5746.1.1.4.1
Indeks do ostatnio wpisanego zdarzenia w historii dziennika zdarzen -1 oznacza pusty dziennik
                       logErase 1.3.6.1.4.1.5746.1.1.4.2
Kasowanie dziennika zdarzen ustawienie 1 - kasowanie
                       logTable 1.3.6.1.4.1.5746.1.1.4.3
Tabela opisuje dziennik zdarzen
                           logEntry 1.3.6.1.4.1.5746.1.1.4.3.1
Tok_String
                               logIndex 1.3.6.1.4.1.5746.1.1.4.3.1.1
Indeks zdarzenia
                               logEventDescription 1.3.6.1.4.1.5746.1.1.4.3.1.2
Opis Zdarzenia: YYYY/MM/DD HH:MM.SS ZZZ YYYY - rok MM - miesiac DD - dzien HH - godzina MM - minuta SS - sekunda ZZZ - identyfikator zdarzenia
                   es 1.3.6.1.4.1.5746.1.1.5
                       esLastES15T 1.3.6.1.4.1.5746.1.1.5.1
Indeks ostatniego zapisanego rejestru ES15N w tablicy licznikow
                       esLastES15R 1.3.6.1.4.1.5746.1.1.5.2
Indeks ostatniego zapisanego rejestru ES15O w tablicy licznikow
                       esLastSES15T 1.3.6.1.4.1.5746.1.1.5.3
Indeks ostatniego zapisanego rejestru SES15N w tablicy licznikow
                       esLastSES15R 1.3.6.1.4.1.5746.1.1.5.4
Indeks ostatniego zapisanego rejestru SES15O w tablicy licznikow
                       esLastES24T 1.3.6.1.4.1.5746.1.1.5.5
Indeks ostatniego zapisanego rejestru ES24N w tablicy licznikow
                       esLastES24R 1.3.6.1.4.1.5746.1.1.5.6
Indeks ostatniego zapisanego rejestru ES24O w tablicy licznikow
                       esLastSES24T 1.3.6.1.4.1.5746.1.1.5.7
Indeks ostatniego zapisanego rejestru SES24N w tablicy licznikow
                       esLastSES24R 1.3.6.1.4.1.5746.1.1.5.8
Indeks ostatniego zapisanego rejestru SES24O w tablicy licznikow
                       esErase 1.3.6.1.4.1.5746.1.1.5.9
Kasowanie rejestrow Es/Ses ustawienie 1 - kasowanie
                       esESAlarm 1.3.6.1.4.1.5746.1.1.5.10
Aktywacja alarmu przekroczenia wartooeci progowej ES lub SES 0 - nieaktywny 1 - aktywny
                       esES15On 1.3.6.1.4.1.5746.1.1.5.11
Wartosc progowa zalaczenia alarmu niepilnego w okresie 15 min. (0-900)
                       esES15Off 1.3.6.1.4.1.5746.1.1.5.12
Wartosc progowa wylaczenia alarmu niepilnego w okresie 15 min. (0-900)
                       esSES15On 1.3.6.1.4.1.5746.1.1.5.13
Wartosc progowa zalaczenia alarmu pilnego w okresie 15 min. (0-900)
                       esSES15Off 1.3.6.1.4.1.5746.1.1.5.14
Wartosc progowa wylaczenia alarmu pilnego w okresie 15 min. (0-900)
                       esES24On 1.3.6.1.4.1.5746.1.1.5.15
Wartosc progowa zalaczenia alarmu niepilnego w okresie 24 h. (0-86400)
                       esES24Off 1.3.6.1.4.1.5746.1.1.5.16
Wartosc progowa wylaczenia alarmu niepilnego w okresie 24 h. (0-86400)
                       esSES24On 1.3.6.1.4.1.5746.1.1.5.17
Wartosc progowa zalaczenia alarmu pilnego w okresie 24 h. (0-86400)
                       esSES24Off 1.3.6.1.4.1.5746.1.1.5.18
Wartosc progowa wylaczenia alarmu pilnego w okresie 24 h. (0-86400)
                       esESSESHour 1.3.6.1.4.1.5746.1.1.5.19
Godzina rozpoczecia zliczania w rejestrach ES i SES
                       esESSESMinute 1.3.6.1.4.1.5746.1.1.5.20
Minuta rozpoczecia zliczania w rejestrach ES i SES
                       esTableES15T 1.3.6.1.4.1.5746.1.1.5.21
Tabela opisuje zapis licznikow ES15N
                             esEntryES15T 1.3.6.1.4.1.5746.1.1.5.21.1
Tok_String
                                 esIndexES15T 1.3.6.1.4.1.5746.1.1.5.21.1.1
Indeks
                                 esEventDescriptionES15T 1.3.6.1.4.1.5746.1.1.5.21.1.2
Opis: YYYY/MM/DD HH:MM LLL A YYYY - rok MM - miesiac DD - dzien HH - godzina MM - minuta LLL - licznik sekund z bledami
                       esTableES15R 1.3.6.1.4.1.5746.1.1.5.22
Tabela opisuje zapis licznika ES15O
                             esEntryES15R 1.3.6.1.4.1.5746.1.1.5.22.1
Tok_String
                                 esIndexES15R 1.3.6.1.4.1.5746.1.1.5.22.1.1
Indeks
                                 esEventDescriptionES15R 1.3.6.1.4.1.5746.1.1.5.22.1.2
Opis: YYYY/MM/DD HH:MM LLL A YYYY - rok MM - miesiac DD - dzien HH - godzina MM - minuta LLL - licznik sekund z bledami
                       esTableSES15T 1.3.6.1.4.1.5746.1.1.5.23
Tabela opisuje zapis licznika SES15N
                             esEntrySES15T 1.3.6.1.4.1.5746.1.1.5.23.1
Tok_String
                                 esIndexSES15T 1.3.6.1.4.1.5746.1.1.5.23.1.1
Indeks
                                 esEventDescriptionSES15T 1.3.6.1.4.1.5746.1.1.5.23.1.2
Opis: YYYY/MM/DD HH:MM LLL A YYYY - rok MM - miesiac DD - dzien HH - godzina MM - minuta LLL - licznik sekund z bledami
                       esTableSES15R 1.3.6.1.4.1.5746.1.1.5.24
Tabela opisuje zapis licznika SES15O
                             esEntrySES15R 1.3.6.1.4.1.5746.1.1.5.24.1
Tok_String
                                 esIndexSES15R 1.3.6.1.4.1.5746.1.1.5.24.1.1
Indeks
                                 esEventDescriptionSES15R 1.3.6.1.4.1.5746.1.1.5.24.1.2
Opis: YYYY/MM/DD HH:MM LLL A YYYY - rok MM - miesiac DD - dzien HH - godzina MM - minuta LLL - licznik sekund z bledami
                       esTableES24T 1.3.6.1.4.1.5746.1.1.5.25
Tabela opisuje zapis licznika ES24N
                             esEntryES24T 1.3.6.1.4.1.5746.1.1.5.25.1
Tok_String
                                 esIndexES24T 1.3.6.1.4.1.5746.1.1.5.25.1.1
Indeks
                       esTableES24R 1.3.6.1.4.1.5746.1.1.5.26
Tabela opisuje zapis licznika ES24O
                             esEntryES24R 1.3.6.1.4.1.5746.1.1.5.26.1
Tok_String
                                 esIndexES24R 1.3.6.1.4.1.5746.1.1.5.26.1.1
Indeks
                                 esEventDescriptionES24R 1.3.6.1.4.1.5746.1.1.5.26.1.2
Opis: YYYY/MM/DD HH:MM LLLLL A YYYY - rok MM - miesiac DD - dzien HH - godzina MM - minuta LLLLL- licznik sekund z bledami
                       esTableSES24T 1.3.6.1.4.1.5746.1.1.5.27
Tabela opisuje zapis licznika SES24N
                             esEntrySES24T 1.3.6.1.4.1.5746.1.1.5.27.1
Tok_String
                                 esIndexSES24T 1.3.6.1.4.1.5746.1.1.5.27.1.1
Indeks
                                 esEventDescriptionES24T 1.3.6.1.4.1.5746.1.1.5.27.1.2
Opis: YYYY/MM/DD HH:MM LLLLL A YYYY - rok MM - miesiac DD - dzien HH - godzina MM - minuta LLLLL- licznik sekund z bledami
                       esTableSES24R 1.3.6.1.4.1.5746.1.1.5.28
Tabela opisuje zapis licznika SES24O
                             esEntrySES24R 1.3.6.1.4.1.5746.1.1.5.28.1
Tok_String
                                 esIndexSES24R 1.3.6.1.4.1.5746.1.1.5.28.1.1
Indeks
                                 esEventDescriptionSES24R 1.3.6.1.4.1.5746.1.1.5.28.1.2
Opis: YYYY/MM/DD HH:MM LLLLL A YYYY - rok MM - miesiac DD - dzien HH - godzina MM - minuta LLLLL- licznik sekund z bledami
                   test 1.3.6.1.4.1.5746.1.1.6
                       testTributaryChannLoopType1 1.3.6.1.4.1.5746.1.1.6.1
Zalaczenie petli kanalu skladowego 1 - 4 do interfejsu. (ALx = 1 zaczenie petli, ALx = 0 wyczene petli na kanale x) bit : 3 2 1 0 nazwa : AL4 AL3 AL2 AL1
                       testGeneratorDetector 1.3.6.1.4.1.5746.1.1.6.5
numer generatora/detektora wykorzystywanego do testu 1..4 - generator w kierunku kanalu skladowego (E1) 1..4
                       testGCT 1.3.6.1.4.1.5746.1.1.6.6
Sterowanie zaczaniem/wyczaniem generatorow testowych wybranych kanaow skladowych/zbiorczych: 1 - generator zaczony 0 - generator wyczony
                       testTime 1.3.6.1.4.1.5746.1.1.6.7
Deklarowany czas trwania testu w sekundach. Maks. 24 godziny
                       testSyncTime 1.3.6.1.4.1.5746.1.1.6.8
czas pomiaru gdy jest synchronizacja
                       testNoSyncTime 1.3.6.1.4.1.5746.1.1.6.9
czas pomiaru gdy brak synchronizacji
                       testErrorsPerSec 1.3.6.1.4.1.5746.1.1.6.10
Biezaca liczba bledow w cyklu sekundowym
                       testTotalErrorNumber 1.3.6.1.4.1.5746.1.1.6.11
Calkowita liczba bledow
                       testBER 1.3.6.1.4.1.5746.1.1.6.12
Stopa bledow w formacie: P.Pe-LL (notacja naukowa) przyklad: 2.3e-09
                       testSyncYesNo 1.3.6.1.4.1.5746.1.1.6.16
Flaga synchronizacji (1 - oznacza detekcje cigu testowego)
                       testStatus 1.3.6.1.4.1.5746.1.1.6.17
status wykonywania testu 0 - OFF - test wyczony 1 - ON - test zaczony 2 - RUN - test trwa 3 - READY - gotowooeae do rozpoczecia testu 4 - WAIT_ON - oczekiwanie na zaczenie testu 5 - WAIT_OFF - oczekiwanie na wyczenie testu 6 - WAIT - oczekiwanie
                   optiLine4MIBNotifications 1.3.6.1.4.1.5746.1.1.7
                       mibNotificationsPrefix 1.3.6.1.4.1.5746.1.1.7.0
                           trapOptiLine4ALPActive 1.3.6.1.4.1.5746.1.1.7.0.1
Aktywny Alarm pilny
                           trapOptiLine4ALNActive 1.3.6.1.4.1.5746.1.1.7.0.2
Aktywny Alarm niepilny
                           trapOptiLine4LogIdn 1.3.6.1.4.1.5746.1.1.7.0.3
Wystapienie zdarzenia w urzadzeniu: 1.Zapis do lokalnego dziennika zdarzen 2.Przekazanie identyfikatora zdarzenia w trapie
                           trapOptiLine4Es 1.3.6.1.4.1.5746.1.1.7.0.4
Zmiana w licznikach es/ses
                           trapOptiLine4confn 1.3.6.1.4.1.5746.1.1.7.0.5
Zapis do zmiennej z grupy knfiguracja, n - identyfikator elementu, ktory zostal zmodyfikowany
                           trapOptiLine4ALPInactive 1.3.6.1.4.1.5746.1.1.7.0.6
Nieaktywny Alarm pilny
                           trapOptiLine4ALNInactive 1.3.6.1.4.1.5746.1.1.7.0.7
Nieaktywny Alarm niepilny
                       optiLine4MIBObjects 1.3.6.1.4.1.5746.1.1.7.1
                           obEventIdn 1.3.6.1.4.1.5746.1.1.7.1.1
Nr zdarzenia
                           obEventDescription 1.3.6.1.4.1.5746.1.1.7.1.2
Opis zdarzenia