RAISECOM-FANMONITOR-MIB: View SNMP OID List / Download MIB

VENDOR: BEIJING RAISECOM SCIENTIFIC N TECHNOLOGY DEV.


 Home MIB: RAISECOM-FANMONITOR-MIB
Download as:   

Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
 raisecomFanMonitor 1.3.6.1.4.1.8886.1.1.5
     raisecomFanMonitorNotification 1.3.6.1.4.1.8886.1.1.5.1
         raisecomFanSpeedNormal 1.3.6.1.4.1.8886.1.1.5.1.1
The trap notification occur when fan state translating from abnormal to normal.
         raisecomFanSpeedAbnormal 1.3.6.1.4.1.8886.1.1.5.1.2
The trap notification occur when fan state translatingfrom normal to abnormal.
         raisecomFanCardUp 1.3.6.1.4.1.8886.1.1.5.1.3
The trap notification occur when fan card state translating from down to up.
         raisecomFanCardDown 1.3.6.1.4.1.8886.1.1.5.1.4
The trap notification occur when fan card state translating from up to down.
     raisecomFanMonitorMibObjects 1.3.6.1.4.1.8886.1.1.5.2
         raisecomFanMonitorGlobalGroup 1.3.6.1.4.1.8886.1.1.5.2.1
             raisecomFanMonitorMode 1.3.6.1.4.1.8886.1.1.5.2.1.1
An integer value that specify the current monitor mode. ENFORCE(1) means that the fan speed need to set manully; AUTO(2) means that the fan speed will ajusted autoly according to the temperature
             raisecomFanMonitorSpdLevel 1.3.6.1.4.1.8886.1.1.5.2.1.2
Specify the speed level of fan in enforce mode.
             raisecomFanMonitorNumber 1.3.6.1.4.1.8886.1.1.5.2.1.3
Specify the number of fan being monitorred.
             raisecomFanMonitorLevlNumber 1.3.6.1.4.1.8886.1.1.5.2.1.4
Specify the total number of fan speed levels.
             raisecomFanCardState 1.3.6.1.4.1.8886.1.1.5.2.1.5
Specify the current state of fan cards. all_down(1) means that all fan cards are down; all_up(2) means that all fan cards are up; card1_up(3) means that fan card 1 is up, the others are down; card2_up(4) means that fan card 2 is up, the others are down.
             raisecomFanCardSerialNumber 1.3.6.1.4.1.8886.1.1.5.2.1.6
specify the identical serial number of current fan card,this string number will be set when device leaving factory
             raisecomFanMonitorTrapSendEnable 1.3.6.1.4.1.8886.1.1.5.2.1.7
Specifies the status of sending trap
         raisecomFanMonitorStateTable 1.3.6.1.4.1.8886.1.1.5.2.2
Fan monitor state table.
             raisecomFanMonitorStateEntry 1.3.6.1.4.1.8886.1.1.5.2.2.1
Fan monitor state entry.
                 raisecomFanIndex 1.3.6.1.4.1.8886.1.1.5.2.2.1.1
Specify the sequence number of fan.
                 raisecomFanSpeedValue 1.3.6.1.4.1.8886.1.1.5.2.2.1.2
Specify the actural speed of the current fan.
                 raisecomFanWorkState 1.3.6.1.4.1.8886.1.1.5.2.2.1.3
Specify the current state of fan normal(1) means the current fan operate normally; abnormal(2) means the current fan operate abnormally
         raisecomFanSpeedLevelTable 1.3.6.1.4.1.8886.1.1.5.2.3
fan speed level information table.
             raisecomFanSpeedLevelEntry 1.3.6.1.4.1.8886.1.1.5.2.3.1
fan speed level information entry.
                 raisecomFanSpeedLevelIndex 1.3.6.1.4.1.8886.1.1.5.2.3.1.1
Specify the fan speed level index.
                 raisecomFanSpeedDueValue 1.3.6.1.4.1.8886.1.1.5.2.3.1.2
Specify the speed value that match the fan levle index. this value can ben get from a new or normal fan ,not an used fan ,because the used fan may be aged
                 raisecomFanSpeedTemperatureScale 1.3.6.1.4.1.8886.1.1.5.2.3.1.3
Specify the temperature scale border that match the speed levle, based on this scale border,the current fan speed will ajusted autoly according to the current temperature