LSI-MegaRAID-SAS-MIB: View SNMP OID List / Download MIB

VENDOR: LSI LOGIC


 Home MIB: LSI-MegaRAID-SAS-MIB
Download as:   

Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
 lsi 1.3.6.1.4.1.3582
           storageComponents 1.3.6.1.4.1.3582.4
               lsiRAIDServer 1.3.6.1.4.1.3582.4.1
                   hostName 1.3.6.1.4.1.3582.4.1.1
Name of the host system.
                   hostOSInfo 1.3.6.1.4.1.3582.4.1.2
Operating System description where SNMP agent is running.
                   versionInfo 1.3.6.1.4.1.3582.4.1.3
                       mibVersion 1.3.6.1.4.1.3582.4.1.3.1
The MIB version no. (xx.yy)
                       agentModuleName 1.3.6.1.4.1.3582.4.1.3.2
The agent module name
                       agentModuleVersion 1.3.6.1.4.1.3582.4.1.3.3
The module version in xx.yy format. Where xx is the major version number and yy is the minor version number(without build information).
                       releaseDate 1.3.6.1.4.1.3582.4.1.3.4
Module Release Date
                   megaRAID-SAS 1.3.6.1.4.1.3582.4.1.4
                       adapter 1.3.6.1.4.1.3582.4.1.4.1
                           adpNumber 1.3.6.1.4.1.3582.4.1.4.1.1
The total no of SAS adapters present.
                           adapterPropertiesTable 1.3.6.1.4.1.3582.4.1.4.1.2
A List of adapter Entries containing Information/Properties about the adapters.
                               adapterPropertiesEntry 1.3.6.1.4.1.3582.4.1.4.1.2.1
An Entry in the adapter table.
                                   adapterID-APT 1.3.6.1.4.1.3582.4.1.4.1.2.1.1
AdapterID for this Adapter.(Unique)
                                   rebuildRate 1.3.6.1.4.1.3582.4.1.4.1.2.1.2
Rebuild rate on this Adapter.
                                   reconstructionRate 1.3.6.1.4.1.3582.4.1.4.1.2.1.3
Reconstruction rate on this Adapter.
                                   alarmState 1.3.6.1.4.1.3582.4.1.4.1.2.1.4
Alarm is enabled or disabled on this adapter. Values: disabled(0),enabled(1)
                                   cacheFlushInterval 1.3.6.1.4.1.3582.4.1.4.1.2.1.5
Cache flush interval in seconds for this adapter.
                                   clusterState 1.3.6.1.4.1.3582.4.1.4.1.2.1.6
Cluster is enabled or disabled on this adapter. Values: disabled(0),enabled(1)
                                   predFailPollInterval 1.3.6.1.4.1.3582.4.1.4.1.2.1.7
Number of seconds between precdictive fail polls on this adapter.
                                   intThrottleCount 1.3.6.1.4.1.3582.4.1.4.1.2.1.8
Interrupt throttle active count on this adapter.
                                   intThrottleTimeUs 1.3.6.1.4.1.3582.4.1.4.1.2.1.9
Interrupt throttle completion hold time on this adapter.
                                   patrolReadRate 1.3.6.1.4.1.3582.4.1.4.1.2.1.10
Patrol Read Rate for this adapter.
                                   bgiRate 1.3.6.1.4.1.3582.4.1.4.1.2.1.11
Background initialization rate for this adapter.
                                   spinupDelay 1.3.6.1.4.1.3582.4.1.4.1.2.1.12
Number of seconds to delay among spinup groups for this adapter.
                                   spinupDriveCount 1.3.6.1.4.1.3582.4.1.4.1.2.1.13
Maximum number of drives to spin up at one time for this adapter.
                                   coercionMode 1.3.6.1.4.1.3582.4.1.4.1.2.1.14
Drive capacity coercion mode. 0->None; 1->128MB; 2->1GB
                                   nvramSize 1.3.6.1.4.1.3582.4.1.4.1.2.1.15
NVRAM size in KB for this adapter.
                                   memorySize 1.3.6.1.4.1.3582.4.1.4.1.2.1.16
Memory size in MB for this adapter.
                                   flashSize 1.3.6.1.4.1.3582.4.1.4.1.2.1.17
Flash size in MB for this adapter.
                                   vdPresentCount 1.3.6.1.4.1.3582.4.1.4.1.2.1.18
Virtual devices present in this adapter.
                                   vdDegradedCount 1.3.6.1.4.1.3582.4.1.4.1.2.1.19
Number of virtual devices in this adapter that are critical
                                   vdOfflineCount 1.3.6.1.4.1.3582.4.1.4.1.2.1.20
Number of virtual devices in this adapter that are offline
                                   pdPresentCount 1.3.6.1.4.1.3582.4.1.4.1.2.1.21
Physical devices present in this adapter.
                                   pdDiskPresentCount 1.3.6.1.4.1.3582.4.1.4.1.2.1.22
Physical disk devices present in this adapter.
                                   pdDiskPredFailureCount 1.3.6.1.4.1.3582.4.1.4.1.2.1.23
Number of disk devices in this adapter that are critical
                                   pdDiskFailedCount 1.3.6.1.4.1.3582.4.1.4.1.2.1.24
Number of disk devices in this adapter that are failed
                                   ccRate 1.3.6.1.4.1.3582.4.1.4.1.2.1.25
Consistency Check rate on this Adapter.
                                   compatibilityFlag 1.3.6.1.4.1.3582.4.1.4.1.2.1.26
To inform compatibilities between Applications and FW. 0->incompatible; 1->compatible
                                   compatibilityInfo 1.3.6.1.4.1.3582.4.1.4.1.2.1.27
Compatibility Information. Format->(Firmware Forward compatibility flag:Firmware Backward compatibility flag:Firmware version flag:Application Forward compatibility flag:Application Backward compatibility flag:Application version flag)
                                   abortCConError 1.3.6.1.4.1.3582.4.1.4.1.2.1.28
Abort CC on detecting error is enabled or disabled on this adapter. Values: No(0),Yes(1),NA(2)
                                   copyBackState 1.3.6.1.4.1.3582.4.1.4.1.2.1.29
CopyBack is enabled or disabled on this adapter.Values: disabled(0),enabled(1)
                                   multipathSupport 1.3.6.1.4.1.3582.4.1.4.1.2.1.31
Multipath is supported or not supported on this adapter.Values: not supported(0),supported(1)
                                   ssdSMARTerEnabled 1.3.6.1.4.1.3582.4.1.4.1.2.1.32
Copyback to SSD on SMART error. Values Enabled(0),Disabled(1)
                                   enableSpinDownUnconfigured 1.3.6.1.4.1.3582.4.1.4.1.2.1.33
Spin Down Unconfigured Drives(1), Do Not Spin Down Unconfigured Drives(0)
                                   disableSpinDownHotSpare 1.3.6.1.4.1.3582.4.1.4.1.2.1.34
Spin Down Hotspares(0), Do Not Spin Down Hotspares(1)
                                   spinDownTime 1.3.6.1.4.1.3582.4.1.4.1.2.1.35
SpinDownTime in minutes
                                   spinupEnclDriveCount 1.3.6.1.4.1.3582.4.1.4.1.2.1.36
Maximum number of drives that can be spin up in an enclosure
                                   spinupEnclDelay 1.3.6.1.4.1.3582.4.1.4.1.2.1.37
Delay between drive spin up for drives within an enclosure
                                   defaultLdPSPolicy 1.3.6.1.4.1.3582.4.1.4.1.2.1.38
power saving policy.values:controller default power saving policy=0, AUTO=1, MAX=2, Max with no cache=6, NONE=255
                                   disableLdPSInterval 1.3.6.1.4.1.3582.4.1.4.1.2.1.39
LD power savings are disabled for yy hours beginning at disableLdPSTime.
                                   disableLdPSTime 1.3.6.1.4.1.3582.4.1.4.1.2.1.40
LD power savings shall be disabled at xx minutes from 12:00am.
                                   supportBreakMirror 1.3.6.1.4.1.3582.4.1.4.1.2.1.41
1=Support break mirror operation,0=Do not Support break mirror operation
                                   temperatureROC 1.3.6.1.4.1.3582.4.1.4.1.2.1.42
temperature of RAID On Chip in Celsius
                                   temperatureCtrl 1.3.6.1.4.1.3582.4.1.4.1.2.1.43
temperature of controller in Celsius
                                   preventPIImport 1.3.6.1.4.1.3582.4.1.4.1.2.1.44
1=Prevent import of SAS PI protected logical disks , 0=Not Prevent import of SAS PI protected logical disks
                                   enablePI 1.3.6.1.4.1.3582.4.1.4.1.2.1.45
1 = Enable SAS PI for controller , 0 = Disable SAS PI for controller
                                   totalSpaceformetadata 1.3.6.1.4.1.3582.4.1.4.1.2.1.46
Total Space used for MetaData
                                   useEmergencySpare 1.3.6.1.4.1.3582.4.1.4.1.2.1.47
This field give the information about Emergency Spare possible Drive types(Uncongiured Good/Global Hotspare)
                                   useEmergencySparesforSMARTer 1.3.6.1.4.1.3582.4.1.4.1.2.1.48
1 = Use Emergency spares for SMARTer ,0 = Not Use Emergency spares for SMARTer
                                   supportShieldState 1.3.6.1.4.1.3582.4.1.4.1.2.1.49
1 =Support PD shield state ,0 = Not Support PD shield state
                                   writeCacheCapable 1.3.6.1.4.1.3582.4.1.4.1.2.1.50
1 = SSC support write caching IOs ,0 = SSC not support write caching IOs
                                   totalCacheSize 1.3.6.1.4.1.3582.4.1.4.1.2.1.51
This field give the information about total Size of currently configured SSC,in GB
                                   maximumCacheSize 1.3.6.1.4.1.3582.4.1.4.1.2.1.52
This field give the information about maxmium Size of SSC that can yet be configured,in GB
                                   ctrlSasAddr 1.3.6.1.4.1.3582.4.1.4.1.2.1.53
This field gives the controller SAS address
                                   domainId 1.3.6.1.4.1.3582.4.1.4.1.2.1.54
This field gives the Domain ID
                                   peerControllerStatus 1.3.6.1.4.1.3582.4.1.4.1.2.1.55
This field gives the Peer controller Status
                                   maximumControllerNodes 1.3.6.1.4.1.3582.4.1.4.1.2.1.56
This field gives the HA nodes this FW supports
                                   incompatibilityDetails 1.3.6.1.4.1.3582.4.1.4.1.2.1.57
This field gives the Incompatibility Details
                                   topologyType 1.3.6.1.4.1.3582.4.1.4.1.2.1.58
This field gives the Topology Type
                                   supportOnlineFWUpdate 1.3.6.1.4.1.3582.4.1.4.1.2.1.59
1 = Online firmware update is supported, 0 = Online firmware update is not supported
                                   supportFastPathWB 1.3.6.1.4.1.3582.4.1.4.1.2.1.60
1 = Support Fast Path WB on Raptor Type Ld ,0 = Does not support Fast Path WB on Raptor Type Ld
                                   supportConfigAutoBalance 1.3.6.1.4.1.3582.4.1.4.1.2.1.61
0 = no configuration auto balance support, 1 = configuration auto balance support is present
                                   maintenanceMode 1.3.6.1.4.1.3582.4.1.4.1.2.1.62
1=FW supports maintenance mode
                                   disableLargeIO 1.3.6.1.4.1.3582.4.1.4.1.2.1.63
0 = Large IO is supported, 1 = Large IO is unsupported
                           adapterInfoTable 1.3.6.1.4.1.3582.4.1.4.1.3
A List of adapter Entries containing Information/Properties about the adapters on the Controller.
                               adapterInfoEntry 1.3.6.1.4.1.3582.4.1.4.1.3.1
An Entry in the adapterInfo table.
                                   adapterID-AIT 1.3.6.1.4.1.3582.4.1.4.1.3.1.1
AdapterID for this Adapter.(Unique)
                                   adapterVendorID 1.3.6.1.4.1.3582.4.1.4.1.3.1.2
PCI Vendor ID for this Adapter.
                                   devID 1.3.6.1.4.1.3582.4.1.4.1.3.1.3
PCI Device ID for this Adapter.
                                   subVendorID 1.3.6.1.4.1.3582.4.1.4.1.3.1.4
PCI Sub-Vendor ID for this adapter.
                                   subDevID 1.3.6.1.4.1.3582.4.1.4.1.3.1.5
PCI Sub-Device ID for this adapter.
                                   hostInterface 1.3.6.1.4.1.3582.4.1.4.1.3.1.6
Host interface information for this adapter. Values: N/A(0),PCIX(1),PCIE(2),iSCSI(3),SAS-3G(4)
                                   hostInterfacePortCnt 1.3.6.1.4.1.3582.4.1.4.1.3.1.7
Port Count on this adapter.
                                   hostInterfacePortAddr 1.3.6.1.4.1.3582.4.1.4.1.3.1.8
Port address comma delimited
                                   devInterface 1.3.6.1.4.1.3582.4.1.4.1.3.1.9
Multiple device interface support values separated by space.
                                   devInterfacePortCnt 1.3.6.1.4.1.3582.4.1.4.1.3.1.10
Device Port Count on this adapter.
                                   devInterfacePortAddr 1.3.6.1.4.1.3582.4.1.4.1.3.1.11
Device Port address comma delimited
                                   productName 1.3.6.1.4.1.3582.4.1.4.1.3.1.12
Product name e.g. MegaRAID SAS-8E, MegaRAID SAS-4X, etc.
                                   serialNo 1.3.6.1.4.1.3582.4.1.4.1.3.1.13
Controller serial number
                                   firmwareVersion 1.3.6.1.4.1.3582.4.1.4.1.3.1.14
Firmware version Format->(Firmware Package Version:Version:Date:Time)
                                   driverVersion 1.3.6.1.4.1.3582.4.1.4.1.3.1.15
Driver version Format->(Driver Name:Version)
                                   expanderFirmwareVersion 1.3.6.1.4.1.3582.4.1.4.1.3.1.16
Expander firmware version - Not Available if expander is not present on the controller
                                   lockKeyBinding 1.3.6.1.4.1.3582.4.1.4.1.3.1.17
Type of lock key binding. lock key is not bound(0),lock key bound to FW secret key(1), lock key bound to user(2), lock key bound to a TPM(3)
                                   maxDAPdCountSpinup60 1.3.6.1.4.1.3582.4.1.4.1.3.1.18
Maximum number of drives to spinup within 60 sec for direct attached drives
                           adapterSupportInfoTable 1.3.6.1.4.1.3582.4.1.4.1.4
A List of adapter Entries containing Information/Properties about the adapters on the Controller.
                               adapterSupportInfoEntry 1.3.6.1.4.1.3582.4.1.4.1.4.1
An Entry in the adapter table.
                                   adapterID-ASIT 1.3.6.1.4.1.3582.4.1.4.1.4.1.1
AdapterID for this Adapter.(Unique)
                                   maxArms 1.3.6.1.4.1.3582.4.1.4.1.4.1.2
Maximum arms per Virtual Drive supported for this Adapter.
                                   maxSpans 1.3.6.1.4.1.3582.4.1.4.1.4.1.3
Maximum spans per Virtual Drive supported for this Adapter.
                                   maxArrays 1.3.6.1.4.1.3582.4.1.4.1.4.1.4
Maximum no of arrays supported for this adapter.
                                   maxVDs 1.3.6.1.4.1.3582.4.1.4.1.4.1.5
Maximum number of Virtual Drive s supported for this adapter.
                                   hardwarePresent 1.3.6.1.4.1.3582.4.1.4.1.4.1.6
Supported Hardware on this adapter. bbu(1),alarm(2),nvram(3),uart(4),TPM(5),expander(6). For multiple hw support a space delimited list will appear.
                                   maxConcurrentCmds 1.3.6.1.4.1.3582.4.1.4.1.4.1.7
The maximum parallel commands supported on this adapter.
                                   maxSGECount 1.3.6.1.4.1.3582.4.1.4.1.4.1.8
The maximum Scatter Gather Element count allowed on this adapter.
                                   maxRequestSize 1.3.6.1.4.1.3582.4.1.4.1.4.1.9
The maximum data transfer size in sectors, on this adapter.
                                   maxLdsPerArray 1.3.6.1.4.1.3582.4.1.4.1.4.1.10
Max Lds per array in adapter
                                   partitionsInDDF 1.3.6.1.4.1.3582.4.1.4.1.4.1.11
Max LDs per Array in configuration
                                   allowSSDMixInLD 1.3.6.1.4.1.3582.4.1.4.1.4.1.12
allow SAS/SATA SSD mix within an LD. allow(1), not allow(0)
                                   allowMixSSDHDDInLD 1.3.6.1.4.1.3582.4.1.4.1.4.1.13
allow SSD/HDD mix within an LD.allow(1), not allow(0)
                           adapterOperationsSupportInfoTable 1.3.6.1.4.1.3582.4.1.4.1.5
A List of adapter Entries containing Information/Properties about the adapters on the Controller.
                               adapterOperationsSupportInfoEntry 1.3.6.1.4.1.3582.4.1.4.1.5.1
An Entry in the adapter table.
                                   adapterID 1.3.6.1.4.1.3582.4.1.4.1.5.1.1
AdapterID for this Adapter.(Unique)
                                   rbldRateSupported 1.3.6.1.4.1.3582.4.1.4.1.5.1.2
Rebuilding rate change support for this Adapter. Values: false(0),true(1)
                                   ccRateSupported 1.3.6.1.4.1.3582.4.1.4.1.5.1.3
Consistency Check rate change support for this Adapter. Values: false(0),true(1)
                                   bgiRateSupported 1.3.6.1.4.1.3582.4.1.4.1.5.1.4
Background initialization rate change support for this adapter. Values: false(0),true(1)
                                   reconRateSupported 1.3.6.1.4.1.3582.4.1.4.1.5.1.5
Reconstruction rate change support for this adapter. Values: false(0),true(1)
                                   patrolRateSupported 1.3.6.1.4.1.3582.4.1.4.1.5.1.6
Patrol read rate change support for this adapter. Values: false(0),true(1)
                                   alarmControlSupported 1.3.6.1.4.1.3582.4.1.4.1.5.1.7
Alarm control support for this adapter. Values: false(0),true(1)
                                   clusterSupported 1.3.6.1.4.1.3582.4.1.4.1.5.1.8
Cluster support for this adapter. Values: false(0),true(1)
                                   bbuSupported 1.3.6.1.4.1.3582.4.1.4.1.5.1.9
BBU support for this adapter. Values: false(0),true(1)
                                   spanningAllowedSupported 1.3.6.1.4.1.3582.4.1.4.1.5.1.10
Spanning support for this adapter. Values: false(0),true(1)
                                   dedicatedHotSparesSupported 1.3.6.1.4.1.3582.4.1.4.1.5.1.11
Dedicated HotSpares support for this adapter. Values: false(0),true(1)
                                   revertibleHotSparesSupported 1.3.6.1.4.1.3582.4.1.4.1.5.1.12
Revertible HotSpares support for this adapter. Values: false(0),true(1)
                                   foreignConfigImportSupported 1.3.6.1.4.1.3582.4.1.4.1.5.1.13
Support foreign config import on this adapter. Values: false(0),true(1)
                                   selfDiagnosticSupported 1.3.6.1.4.1.3582.4.1.4.1.5.1.14
Controller supports self diagnostic. Values: false(0),true(1)
                                   allowMixedRedundancyOnArraySupported 1.3.6.1.4.1.3582.4.1.4.1.5.1.15
Allow different Virtual Disk on the same array to have different redundancy levels. Values: false(0),true(1)
                                   abortCConErrorSupported 1.3.6.1.4.1.3582.4.1.4.1.5.1.16
Abort CC on detecting error is supported on this adapter. Values: No(0),Yes(1)
                                   securitySupported 1.3.6.1.4.1.3582.4.1.4.1.5.1.17
Displays the security support. if supported (1) , not supported (0)
                                   supportPIcontroller 1.3.6.1.4.1.3582.4.1.4.1.5.1.18
Displays the support PI. 1=LD SAS PI Type 0, 0=LD Not SAS PI Type 0
                           bbuInfo 1.3.6.1.4.1.3582.4.1.4.1.6
                               bbuNumber 1.3.6.1.4.1.3582.4.1.4.1.6.1
The present number of rows in the BBU Table.
                               bbuTable 1.3.6.1.4.1.3582.4.1.4.1.6.2
A List of BBU Entries containing Information/Properties about the BBU.
                                   bbuEntry 1.3.6.1.4.1.3582.4.1.4.1.6.2.1
An Entry in the BBU table.
                                       bbuID 1.3.6.1.4.1.3582.4.1.4.1.6.2.1.1
BBUID for this BBU.(Unique)
                                       batteryType 1.3.6.1.4.1.3582.4.1.4.1.6.2.1.2
BBU Type.
                                       nextLearnTime 1.3.6.1.4.1.3582.4.1.4.1.6.2.1.3
Time of next scheduled learn cycle (seconds past 1/1/2000)
                                       absStateOfCharge 1.3.6.1.4.1.3582.4.1.4.1.6.2.1.4
Predicted remaining capacity expressed as % of DesignCapacity() (0-100). Value of -1 means not supported
                                       fullChargeCapacity 1.3.6.1.4.1.3582.4.1.4.1.6.2.1.5
Predicted pack capacity when it is fully charged in joules
                                       averageEmptyTime 1.3.6.1.4.1.3582.4.1.4.1.6.2.1.6
One-minute rolling average of the predicted remaining battery life. Value of -1 means not supported
                                       cycleCount 1.3.6.1.4.1.3582.4.1.4.1.6.2.1.7
Number of charge cycles the battery has experienced. Value of -1 means not supported
                                       firmwareStatus 1.3.6.1.4.1.3582.4.1.4.1.6.2.1.8
Condition of battery in following order: packMissing(0/1) voltageLow(0/1) temperatureHigh(0/1) chargeActive(0/1) dischargeActive(0/1) learnCycleRequested(0/1) learnCycleActive(0/1) learnCycleFailed(0/1) learnCycleTimeout(0/1) i2cErrorsDetected(0/1) noSpace(0/1) predictiveFailure(0/1) premiumFeatureReqd(0/1) microcodeUpdateReqd(0/1) Only enabled(1) values will be shown
                                       voltage 1.3.6.1.4.1.3582.4.1.4.1.6.2.1.9
Accurate battery terminal voltage in mV, resolution of 1mV
                                       autoLearnPeriod 1.3.6.1.4.1.3582.4.1.4.1.6.2.1.10
Time (in seconds) between learn cycles (0 to disable auto learn)
                                       relStateOfCharge 1.3.6.1.4.1.3582.4.1.4.1.6.2.1.11
Predicted remaining capacity expressed as % of FullChargeCapacity() (0-100). Value of -1 means not supported
                                       capacityRemain 1.3.6.1.4.1.3582.4.1.4.1.6.2.1.12
Predicted charge or energy remaining in the battery in joules
                                       runTimeToEmpty 1.3.6.1.4.1.3582.4.1.4.1.6.2.1.13
Relative gain or loss in remaining life in response to change in power policy represent in minute. Value of -1 means not supported
                                       avgTimeToFull 1.3.6.1.4.1.3582.4.1.4.1.6.2.1.14
One-minute rolling average of predicted remaining time to full charge. Value of -1 means not supported
                                       errorMargin 1.3.6.1.4.1.3582.4.1.4.1.6.2.1.15
Expected margin of error (%) in charge calculation (2-100). Value of -1 means not supported
                                       temperature 1.3.6.1.4.1.3582.4.1.4.1.6.2.1.16
Battery temperature in degree Centigrade
                                       mfgName 1.3.6.1.4.1.3582.4.1.4.1.6.2.1.17
Battery manufacturers name
                                       deviceName 1.3.6.1.4.1.3582.4.1.4.1.6.2.1.18
Battery name
                                       serialNumber 1.3.6.1.4.1.3582.4.1.4.1.6.2.1.19
Battery serialNumber
                                       chargerStatus 1.3.6.1.4.1.3582.4.1.4.1.6.2.1.20
Battery charger status. Values: N/A(-1), off(0), complete(1), progress(2)
                                       adpID 1.3.6.1.4.1.3582.4.1.4.1.6.2.1.21
The adapter id where BBU is attached
                                       remainingCapAlarm 1.3.6.1.4.1.3582.4.1.4.1.6.2.1.22
Remaining capacity to alarm. Value of -1 means not supported
                                       remainingTimeAlarm 1.3.6.1.4.1.3582.4.1.4.1.6.2.1.23
Remaining time to alarm. Value of -1 means not supported
                                       bbu-current 1.3.6.1.4.1.3582.4.1.4.1.6.2.1.24
Current(In mA) being supplied (or accepted) through the battery terminals
                                       gasGaugeStatus 1.3.6.1.4.1.3582.4.1.4.1.6.2.1.25
Gas gauge status
                                       batteryReplacement 1.3.6.1.4.1.3582.4.1.4.1.6.2.1.27
This property denotes whether the Battery needs to be replaced or not.1 =battery needs to be replaced ,0 =battery needs not to be replaced
                                       bbuRetentiontime 1.3.6.1.4.1.3582.4.1.4.1.6.2.1.28
The total no. of hours the battery can support the current capacity reserve. Undefined(0),48 hours+(>48),the exact no of hours(<=48)
                                       bbuState 1.3.6.1.4.1.3582.4.1.4.1.6.2.1.29
This property gives the Information about BBU state. Operational = if BBU is working fine, Non-Operational = if BBU is not working fine
                                       memoryModuleFRU 1.3.6.1.4.1.3582.4.1.4.1.6.2.1.30
tmm FRU
                                       bbuFirmwareVersion 1.3.6.1.4.1.3582.4.1.4.1.6.2.1.31
Battery Firmware Version
                                       autoLearnMode 1.3.6.1.4.1.3582.4.1.4.1.6.2.1.32
Automatic Learn Mode
                                       chargingStatus 1.3.6.1.4.1.3582.4.1.4.1.6.2.1.33
Charging Status
                                       capacitance 1.3.6.1.4.1.3582.4.1.4.1.6.2.1.34
Capacitance
                           commonDeviceInfoTable 1.3.6.1.4.1.3582.4.1.4.1.7
A List of general Physical Disk info
                               commonDeviceInfoEntry 1.3.6.1.4.1.3582.4.1.4.1.7.1
An Entry in the CommonDeviceInfo table.
                                   adapterID-CDIT 1.3.6.1.4.1.3582.4.1.4.1.7.1.1
Unique adapter ID
                                   forceOnline 1.3.6.1.4.1.3582.4.1.4.1.7.1.2
Physical drive force Online operation support. Values: notSupported(0), supported(1)
                                   forceOffline 1.3.6.1.4.1.3582.4.1.4.1.7.1.3
Physical drive force Offline operation support. Values: notSupported(0), supported(1)
                                   forceRebuild 1.3.6.1.4.1.3582.4.1.4.1.7.1.4
Physical drive force Rebuild operation support. Values: notSupported(0), supported(1)
                                   supportsSAS 1.3.6.1.4.1.3582.4.1.4.1.7.1.5
SAS physical drive support. Values: notSupported(0), supported(1)
                                   supportsSATA 1.3.6.1.4.1.3582.4.1.4.1.7.1.6
SATA physical drive support. Values: notSupported(0), supported(1)
                                   allowMixInEnclosure 1.3.6.1.4.1.3582.4.1.4.1.7.1.7
Mix InEnclosure support. Values: notSupported(0), supported(1)
                                   allowMixInVD 1.3.6.1.4.1.3582.4.1.4.1.7.1.8
MixInVIRTUALDRIVE support. Values: notSupported(0), supported(1)
                                   allowSataInCluster 1.3.6.1.4.1.3582.4.1.4.1.7.1.9
SataInCluster support. Values: notSupported(0), supported(1)
                                   setPowerStateForCfg 1.3.6.1.4.1.3582.4.1.4.1.7.1.10
FW requires application to set power state before configuration changes. Required(1), Not Required(0)
                           commonVirtualDeviceInfoTable 1.3.6.1.4.1.3582.4.1.4.1.8
A List of general Virtual Drive info
                               commonVirtualDeviceInfoEntry 1.3.6.1.4.1.3582.4.1.4.1.8.1
An Entry in the CommonVirtualDeviceInfo table.
                                   adapterID-CVDIT 1.3.6.1.4.1.3582.4.1.4.1.8.1.1
Unique adapter ID
                                   supportedReadPolicy 1.3.6.1.4.1.3582.4.1.4.1.8.1.2
Read policy support. Values: false(0),true(1)
                                   supportedWritePolicy 1.3.6.1.4.1.3582.4.1.4.1.8.1.3
Write policy support. Values: false(0),true(1)
                                   supportedIOPolicy 1.3.6.1.4.1.3582.4.1.4.1.8.1.4
IO policy support. Values: false(0),true(1)
                                   supportedAccessPolicy 1.3.6.1.4.1.3582.4.1.4.1.8.1.5
Access policy support. Values: false(0),true(1)
                                   supportedMinSize 1.3.6.1.4.1.3582.4.1.4.1.8.1.6
Minimum stripe size supported. 0(512B),1(1K),2(2K),3(4K),4(8K),5(16K),6(32),7(64K),8(128K) ... 11(1MB) etc
                                   supportedMaxSize 1.3.6.1.4.1.3582.4.1.4.1.8.1.7
Maximum stripe size supported. 0(512B),1(1K),2(2K),3(4K),4(8K),5(16K),6(32),7(64K),8(128K) ... 11(1MB) etc
                                   ldbbm 1.3.6.1.4.1.3582.4.1.4.1.8.1.8
1=LD bad block management is enabled, 0=LD bad block management is not enabled
                           adapterStatusSupportInfoTable 1.3.6.1.4.1.3582.4.1.4.1.9
A List of adapter Entries containing Information/Properties about the adapters on the Controller.
                               adapterStatusSupportInfoEntry 1.3.6.1.4.1.3582.4.1.4.1.9.1
An Entry in the adapter table.
                                   adapterID-ASSIT 1.3.6.1.4.1.3582.4.1.4.1.9.1.1
AdapterID for this Adapter.(Unique)
                                   lockKeyAssigned 1.3.6.1.4.1.3582.4.1.4.1.9.1.2
Lock key Assigned support for this Adapter. Values: false(0),true(1)
                                   lockKeyFailed 1.3.6.1.4.1.3582.4.1.4.1.9.1.3
lock Key Failed support for this Adapter. Values: false(0),true(1)
                                   lockKeyNotBackedup 1.3.6.1.4.1.3582.4.1.4.1.9.1.4
lock Key Not Backedup support for this Adapter. Values: false(0),true(1)
                                   biosNotDetected 1.3.6.1.4.1.3582.4.1.4.1.9.1.5
bios Not Detected support for this Adapter. Values: false(0),true(1)
                                   cacheIsPinned 1.3.6.1.4.1.3582.4.1.4.1.9.1.6
1=controller cache is pinned for missing or offline LDs
                           adapterLdOperationSupportInfoTable 1.3.6.1.4.1.3582.4.1.4.1.10
A List of adapter Entries containing Information/Properties about the adapters on the Controller.
                                 adapterLdOperationSupportInfoEntry 1.3.6.1.4.1.3582.4.1.4.1.10.1
An Entry in the adapter table.
                                     adapterID-ALSIT 1.3.6.1.4.1.3582.4.1.4.1.10.1.1
AdapterID for this Adapter.(Unique)
                                     allowCtrlEncryption 1.3.6.1.4.1.3582.4.1.4.1.10.1.2
if it is set (1) supports controller encryption
                       device 1.3.6.1.4.1.3582.4.1.4.2
                           physicalDriveInfo 1.3.6.1.4.1.3582.4.1.4.2.1
                               pdNumber 1.3.6.1.4.1.3582.4.1.4.2.1.1
The present number of rows in the physical drive table.
                               physicalDriveTable 1.3.6.1.4.1.3582.4.1.4.2.1.2
A List of physical drive Entries containing Information/Properties about the drives
                                   physicalDriveEntry 1.3.6.1.4.1.3582.4.1.4.2.1.2.1
An Entry in the Device Table.
                                       pdIndex 1.3.6.1.4.1.3582.4.1.4.2.1.2.1.1
The unique ID
                                       physDevID 1.3.6.1.4.1.3582.4.1.4.2.1.2.1.2
The Device ID
                                       oemSupported 1.3.6.1.4.1.3582.4.1.4.2.1.2.1.3
Is the drive supported by the OEM (OEM-specific checks). Values: notSupported(1), supported(0)
                                       scsiDevType 1.3.6.1.4.1.3582.4.1.4.2.1.2.1.4
Type of this Device. Values: disk(0),tape(1),printer(2),processor(3),cdrom(5),scanner(6),optical(7),enclosure(13),dvd(10),unknown(31)
                                       connectedAdapterPort 1.3.6.1.4.1.3582.4.1.4.2.1.2.1.5
Adapter port(s) to which the device is connected.
                                       deviceSpeed 1.3.6.1.4.1.3582.4.1.4.2.1.2.1.6
Maximum supported speed. Values: speed-unknown(0),speed-1p5G(1),speed-3G(2),speed-6G(3)
                                       mediaErrCount 1.3.6.1.4.1.3582.4.1.4.2.1.2.1.7
Error count of the device
                                       otherErrCount 1.3.6.1.4.1.3582.4.1.4.2.1.2.1.8
Other error count of the device
                                       predFailCount 1.3.6.1.4.1.3582.4.1.4.2.1.2.1.9
Predictive fail count of the device
                                       pdState 1.3.6.1.4.1.3582.4.1.4.2.1.2.1.10
Firmwares interpretation of drive state. Values: unconfigured-good(0),unconfigured-bad(1),hot-spare(2),offline(16),failed(17),rebuild(20),online(24),copyback(32),system(64),UNCONFIGURED-SHIELDED(128),HOTSPARE-SHIELDED(130),CONFIGURED-SHIELDED(144)
                                       disabledForRemoval 1.3.6.1.4.1.3582.4.1.4.2.1.2.1.11
If true, drive is ready for removal. Values: false(0),true(1)
                                       linkSpeed 1.3.6.1.4.1.3582.4.1.4.2.1.2.1.12
Negotiated link speed. Values: speed-unknown(0),speed-1p5G(1),speed-3G(2),speed-6G(3)
                                       pdSupportFlags 1.3.6.1.4.1.3582.4.1.4.2.1.2.1.13
1st Byte:forcedPDGUID(0/1),2nd Byte:inVD(0/1),3rd Byte:isGlobalSpare(0/1),4th Byte:isSpare(0/1),5th Byte:isForeign(0/1),6th Byte:intf(0-Unknown, 1-parallel SCSI, 2-SAS, 3-SATA, 4-FC).A comma delimited list will appear.
                                       sasAddr 1.3.6.1.4.1.3582.4.1.4.2.1.2.1.14
Device SAS addresses. Comma separeted for multiple address
                                       rawSize 1.3.6.1.4.1.3582.4.1.4.2.1.2.1.15
Size(MB) before COD and coercion
                                       nonCoercedSize 1.3.6.1.4.1.3582.4.1.4.2.1.2.1.16
Size(MB) after COD is reserved but before coercion
                                       coercedSize 1.3.6.1.4.1.3582.4.1.4.2.1.2.1.17
Size(MB) after COD is reserved and after coercion
                                       enclDeviceId 1.3.6.1.4.1.3582.4.1.4.2.1.2.1.18
Enclosures device Id (in decimal); if device is not within enclosure value is -1
                                       enclIndex 1.3.6.1.4.1.3582.4.1.4.2.1.2.1.19
Firmware internal enclosure index
                                       slotNumber 1.3.6.1.4.1.3582.4.1.4.2.1.2.1.20
Slot number of this drive, if the Physical Disk is part of an enclosure then -1
                                       operationProgress 1.3.6.1.4.1.3582.4.1.4.2.1.2.1.21
Operation progress in %. e.g. Rebuild progress is 10%
                                       adpID-PDT 1.3.6.1.4.1.3582.4.1.4.2.1.2.1.22
Controller id where this Physical Drive is attached
                                       operationSupport 1.3.6.1.4.1.3582.4.1.4.2.1.2.1.23
MakeOnline,MakeOffline,MakeFailed,MakeBad,MakeUncofigured, MakeSpare,RemoveSpare,replaceMissing,markMissing,startRebuild, stopRebuild,locate,pdclear,foreignImportNotAllowed,ForeignImportAllowed, startCopyBack,stopCopyBack,fwDownloadNotAllowed,fwDownloadAllowed,makeSystem
                                       pdVendorID 1.3.6.1.4.1.3582.4.1.4.2.1.2.1.24
Vendor ID
                                       pdProductID 1.3.6.1.4.1.3582.4.1.4.2.1.2.1.25
Product ID
                                       pdFwversion 1.3.6.1.4.1.3582.4.1.4.2.1.2.1.26
PD firmware version
                                       diskType 1.3.6.1.4.1.3582.4.1.4.2.1.2.1.27
Type of the disk : 0-Unknown, 1-parallel SCSI, 2-SAS, 3-SATA, 4-FC
                                       partnerDevId 1.3.6.1.4.1.3582.4.1.4.2.1.2.1.28
If drive is in an enclosure with dual paths,This is Partner Device ID. In all other cases INVALID(-1)
                                       mediatype 1.3.6.1.4.1.3582.4.1.4.2.1.2.1.29
Media Type HDD(0),SSD(1),Solid state flash module(2)
                                       powerState 1.3.6.1.4.1.3582.4.1.4.2.1.2.1.30
Power condition of the device. Values are device is active(0),device is stopped(1),device is transitioning between power states(255)
                                       secured 1.3.6.1.4.1.3582.4.1.4.2.1.2.1.31
1=drive is secured, 0=not secured
                                       locked 1.3.6.1.4.1.3582.4.1.4.2.1.2.1.32
1=drive is locked, 0=unlocked
                                       foreign 1.3.6.1.4.1.3582.4.1.4.2.1.2.1.33
1=drive is secured by a foreign lock key, 0=drive is not secured by a foreign lock key
                                       oemCertified 1.3.6.1.4.1.3582.4.1.4.2.1.2.1.34
Is the drive certified by the OEM (OEM-specific checks). Values: notCertified(1), Certified(0)
                                       foreignImportNotAllowed 1.3.6.1.4.1.3582.4.1.4.2.1.2.1.35
1=Drive is not allowed foreignImport operation, 0=Drive is allowed foreignImport operation
                                       pdTemperature 1.3.6.1.4.1.3582.4.1.4.2.1.2.1.36
Physical Drive temperature in Celsius
                                       pdSerialNumber 1.3.6.1.4.1.3582.4.1.4.2.1.2.1.37
Physical Drives serial number
                                       piEligible 1.3.6.1.4.1.3582.4.1.4.2.1.2.1.38
Protection Information eligibility.1=drive can be used for PD Enabled LD , 0=drive cant be used for PD Enabled LD
                                       piType 1.3.6.1.4.1.3582.4.1.4.2.1.2.1.39
SAS Protection Information Type .No SAS protection type used(0) ,SAS PI Type 1(1) ,SAS PI Type 2(2) ,SAS PI Type 3(3) ,Reserved SAS PI Type 4(4) ,Reserved SAS PI Type 5(5) ,Reserved SAS PI Type 6(6) ,Reserved SAS PI Type 7(7).
                                       piFormatted 1.3.6.1.4.1.3582.4.1.4.2.1.2.1.40
formatted for PI information. 1=drive is formatted for PI information, 0=no PI data.
                                       userDataBlockSize 1.3.6.1.4.1.3582.4.1.4.2.1.2.1.41
Number of bytes of user data in LBA
                                       commissionedSpare 1.3.6.1.4.1.3582.4.1.4.2.1.2.1.42
Yes = this PD is a commissioned spare, No = this PD is not a commissioned spare.
                                       emergencySpare 1.3.6.1.4.1.3582.4.1.4.2.1.2.1.43
Eligible = this PD is a emergency spare, Ineligible = this PD is not a emergency spare.
                                       shieldCounter 1.3.6.1.4.1.3582.4.1.4.2.1.2.1.44
How many times the shield diagnostics was run before it was marked failed
                                       shieldDiagCompletionTime 1.3.6.1.4.1.3582.4.1.4.2.1.2.1.45
Last successful Diagnostics completion time. 0 is N/A
                                       ineligibleForSSCD 1.3.6.1.4.1.3582.4.1.4.2.1.2.1.46
Whether PD cannot be used for an SSCD. PD can not be used for an SSCD(1), PD can be used for an SSCD(0)
                                       ineligibleForLd 1.3.6.1.4.1.3582.4.1.4.2.1.2.1.47
Whether PD cannot be used for a regular LD. PD can not be used for a regular LD(1), PD can be used for a regular LD(0)
                                       serviceable 1.3.6.1.4.1.3582.4.1.4.2.1.2.1.48
Whether PD is removeable for service. PD is removeable for service(1), PD is not removeable for service(0)
                       virtualDevice 1.3.6.1.4.1.3582.4.1.4.3
                           vdInfo 1.3.6.1.4.1.3582.4.1.4.3.1
                               vdNumbers 1.3.6.1.4.1.3582.4.1.4.3.1.1
The present number of rows in the virtualDrive table.
                               virtualDriveTable 1.3.6.1.4.1.3582.4.1.4.3.1.2
A List of Virtual Drives Entries containing Information/Properties about the virtualDrive.
                                   virtualDriveEntry 1.3.6.1.4.1.3582.4.1.4.3.1.2.1
An Entry in the virtualDrive Table.
                                       virtualDevID 1.3.6.1.4.1.3582.4.1.4.3.1.2.1.1
The unique Virtual Drives ID
                                       size 1.3.6.1.4.1.3582.4.1.4.3.1.2.1.2
Total size in MB of the drive
                                       clusterOwnerDeviceId 1.3.6.1.4.1.3582.4.1.4.3.1.2.1.3
VD owners device Id
                                       targetId 1.3.6.1.4.1.3582.4.1.4.3.1.2.1.4
Virtual Drive target id (i.e. 0 to 63)
                                       state 1.3.6.1.4.1.3582.4.1.4.3.1.2.1.5
The Device state: Values: offline(0),partially-degraded(1),degraded(2),optimal(3)
                                       name 1.3.6.1.4.1.3582.4.1.4.3.1.2.1.6
Virtual Drive name
                                       defaultCachePolicy 1.3.6.1.4.1.3582.4.1.4.3.1.2.1.7
Default cache policy settings. Values: WriteBack, WriteThrough, ReadAdaptive, ReadAhead, ReadAheadNone, Cached, Direct, Write Cache OK if Bad BBU, No Write Cache if Bad BBU.
                                       accessPolicy 1.3.6.1.4.1.3582.4.1.4.3.1.2.1.8
Access policy settings. Values: access-rw(0), access-read-only(2), access-blocked(3)
                                       diskCachePolicy 1.3.6.1.4.1.3582.4.1.4.3.1.2.1.9
Physical disk cache policy. Values: unchanged(0),enable(1),disable(2)
                                       bgiState 1.3.6.1.4.1.3582.4.1.4.3.1.2.1.10
Disable/Enable Back Groung Initialization on this Virtual Drive. Values: disable(1),enable(0)
                                       prl 1.3.6.1.4.1.3582.4.1.4.3.1.2.1.11
Primay raid level. Values: 0(RAID-0), 1(RAID-1), 3(RAID-3), 4(RAID-4), 5(RAID-5), 6(RAID-6),15(Single Disk or JBOD), 17(RAID-1E), 21(RAID-5E), 31(Concatenation),37(RAID-5EEE)
                                       rLQ 1.3.6.1.4.1.3582.4.1.4.3.1.2.1.12
Raid level qualifier
                                       sRL 1.3.6.1.4.1.3582.4.1.4.3.1.2.1.13
Secondary raid level. Values: 0(Stripped), 1(Mirrored), 2(Concatenated), 3(Spanned)
                                       stripeSize 1.3.6.1.4.1.3582.4.1.4.3.1.2.1.14
Stripe Size. 0(512B),1(1K),2(2K),3(4K),4(8K),5(16K),6(32),7(64K),8(128K) ... 11(1MB) etc
                                       numDrives 1.3.6.1.4.1.3582.4.1.4.3.1.2.1.15
Number of drivers per span
                                       spanDepth 1.3.6.1.4.1.3582.4.1.4.3.1.2.1.16
Number of spans. If only one array then it is considered as 1 span
                                       initState 1.3.6.1.4.1.3582.4.1.4.3.1.2.1.17
0=no init, 1=quick init, 2=full init
                                       vdOperationProgress 1.3.6.1.4.1.3582.4.1.4.3.1.2.1.18
Progress % for an operation / No operation in progress
                                       currentCachePolicy 1.3.6.1.4.1.3582.4.1.4.3.1.2.1.19
Cache policy settings. Values:WriteBack, WriteThrough, ReadAdaptive, ReadAhead, ReadAheadNone, Cached, Direct, Write Cache OK if Bad BBU, No Write Cache if Bad BBU.
                                       adapterID-VDT 1.3.6.1.4.1.3582.4.1.4.3.1.2.1.20
Adapter ID
                                       encryptionType 1.3.6.1.4.1.3582.4.1.4.3.1.2.1.21
logical drive encryption type. Values No Encryption(0), FDE drive encryption(1), Controller-based encryption(2)
                                       vdOperationSupport 1.3.6.1.4.1.3582.4.1.4.3.1.2.1.22
startFGI,stopFGI,startCC,stopCC,startRecon,deleteLD
                                       badBlocksExist 1.3.6.1.4.1.3582.4.1.4.3.1.2.1.23
0 = LD bad block table is empty, 1 = LD bad block table is not empty
                                       defaultPSPolicy 1.3.6.1.4.1.3582.4.1.4.3.1.2.1.24
Power Savings policy set for this LD.Values:controller default power saving policy=0, AUTO=1, MAX=2, MAX with no cache=6, NONE=255
                                       currentPSPolicy 1.3.6.1.4.1.3582.4.1.4.3.1.2.1.25
Power Savings policy set for this LD.Values:controller default power saving policy=0, AUTO=1, MAX=2, MAX with no cache=6, NONE=255
                                       breakMirror 1.3.6.1.4.1.3582.4.1.4.3.1.2.1.26
Break Mirror Policy set for this LD.Values:1=break mirror is allowed, 0=break mirror not is allowed
                                       joinMirror 1.3.6.1.4.1.3582.4.1.4.3.1.2.1.27
Join Mirror policy set for this LD.Values:1=join mirror is allowed, 0=join mirror not is allowed
                                       mirrorPdInfo 1.3.6.1.4.1.3582.4.1.4.3.1.2.1.28
Mirror Info Property give the Information about mirror of PD and PD state respectively.
                                       vdPiType 1.3.6.1.4.1.3582.4.1.4.3.1.2.1.29
Information about logical drive protection type . No SAS protection type used(0) ,SAS PI Type 1(1) ,SAS PI Type 2(2) ,SAS PI Type 3(3) ,Reserved SAS PI Type 4(4) ,Reserved SAS PI Type 5(5) ,Reserved SAS PI Type 6(6) ,Reserved SAS PI Type 7(7) ,SAS PI Type 8(8).
                                       mirrorDataSize 1.3.6.1.4.1.3582.4.1.4.3.1.2.1.30
Total Space used for mirrorData or Parity information
                                       cacheCadeType 1.3.6.1.4.1.3582.4.1.4.3.1.2.1.31
0= Non-CacheCade VD, 1= CacheCade Type is Read & Write, 2= CacheCade Type is Read only, 3= R1-EC
                                       currentWritePolicy 1.3.6.1.4.1.3582.4.1.4.3.1.2.1.32
Current write policy settings. Values: WriteBack, WriteThrough, AlwaysWriteBack
                                       defaultWritePolicy 1.3.6.1.4.1.3582.4.1.4.3.1.2.1.33
Default write policy settings. Values: WriteBack, WriteThrough, AlwaysWriteBack
                                       associatedVD 1.3.6.1.4.1.3582.4.1.4.3.1.2.1.34
This property gives the Information about VD is Cached or VD is not cached.
                                       hostAccessPolicy 1.3.6.1.4.1.3582.4.1.4.3.1.2.1.35
This property gives the Host Access Policy
                                       guid 1.3.6.1.4.1.3582.4.1.4.3.1.2.1.36
This property gives the LD GUID.
                                       fastPathWBEnabled 1.3.6.1.4.1.3582.4.1.4.3.1.2.1.37
0= FastPathWB disabled, not a Raptor like LD, 1= FastPathWB enabled, Raptor like LD
                                       peerHasNoAccess 1.3.6.1.4.1.3582.4.1.4.3.1.2.1.38
Peer cant access this shared ld, not applicable for exclusive LD
                               vdSpanInfoTable 1.3.6.1.4.1.3582.4.1.4.3.1.3
A List of span Entries containing Information/Properties vd span.
                                   vdSpanInfoEntry 1.3.6.1.4.1.3582.4.1.4.3.1.3.1
An Entry in the vdSpan Table.
                                       spanID 1.3.6.1.4.1.3582.4.1.4.3.1.3.1.1
The unique Span ID
                                       vdID-VSIT 1.3.6.1.4.1.3582.4.1.4.3.1.3.1.2
The Virtual Device ID
                                       startBlock 1.3.6.1.4.1.3582.4.1.4.3.1.3.1.3
Span physical disk starting block
                                       numBlocks 1.3.6.1.4.1.3582.4.1.4.3.1.3.1.4
Span physical disk block count
                                       vdSpanArrayRef 1.3.6.1.4.1.3582.4.1.4.3.1.3.1.5
Array reference (index)
                                       adapterID-VSIT 1.3.6.1.4.1.3582.4.1.4.3.1.3.1.6
Adapter ID
                           arrayInfo 1.3.6.1.4.1.3582.4.1.4.3.4
                               arrayNumber 1.3.6.1.4.1.3582.4.1.4.3.4.1
The present number of rows in the array table.
                               arrayTable 1.3.6.1.4.1.3582.4.1.4.3.4.2
A List of array Entries containing Information/Properties about the arrays.
                                   arrayEntry 1.3.6.1.4.1.3582.4.1.4.3.4.2.1
An Entry in the array Table.
                                       arrayID 1.3.6.1.4.1.3582.4.1.4.3.4.2.1.1
The unique array ID
                                       arraySize 1.3.6.1.4.1.3582.4.1.4.3.4.2.1.2
Size in MB
                                       arrayNumDrives 1.3.6.1.4.1.3582.4.1.4.3.4.2.1.3
Number of drives for this array
                                       arrayRef 1.3.6.1.4.1.3582.4.1.4.3.4.2.1.4
Tag for the array
                                       pdList 1.3.6.1.4.1.3582.4.1.4.3.4.2.1.5
Space separated Physical Drive identification. e.g. {devID devID devID} etc
                                       adapterID-AT 1.3.6.1.4.1.3582.4.1.4.3.4.2.1.6
Adapter ID.
                           spareInfo 1.3.6.1.4.1.3582.4.1.4.3.5
                               spareDevNumber 1.3.6.1.4.1.3582.4.1.4.3.5.1
The present number of rows in the sparepool table.
                               spareTable 1.3.6.1.4.1.3582.4.1.4.3.5.2
A List of sparepool Entries containing Information/Properties about the spare drive
                                   spareEntry 1.3.6.1.4.1.3582.4.1.4.3.5.2.1
An Entry in the sparepool Table.
                                       spareID 1.3.6.1.4.1.3582.4.1.4.3.5.2.1.1
The unique Device ID
                                       deviceIdentification 1.3.6.1.4.1.3582.4.1.4.3.5.2.1.2
The unique Device ID
                                       spareType 1.3.6.1.4.1.3582.4.1.4.3.5.2.1.3
Spare type. isDedicated(0/1)isRevertible(0/1)isEnclAffinity(0/1). 1 implies particular feature is enable and 0 represent feature is disable.
                                       arrayCount 1.3.6.1.4.1.3582.4.1.4.3.5.2.1.4
The number of arrays to which the Physical Drive can be dedicated
                                       arrayIDs 1.3.6.1.4.1.3582.4.1.4.3.5.2.1.5
Comma separated array ids. e.g. 2,4,5 etc
                                       adapterID-ST 1.3.6.1.4.1.3582.4.1.4.3.5.2.1.6
Adapter ID.
                   enclosureInfo 1.3.6.1.4.1.3582.4.1.5
                       enclosureNumber 1.3.6.1.4.1.3582.4.1.5.1
The present number of rows in the enclosure table.
                       enclosureTable 1.3.6.1.4.1.3582.4.1.5.2
A List of Enclosure Entries containing Information/Properties about the enclosures in the system.
                           enclosureEntry 1.3.6.1.4.1.3582.4.1.5.2.1
An Entry in the enclosure table.
                               enclosureID 1.3.6.1.4.1.3582.4.1.5.2.1.1
EnclosureID for this enclosure.(Unique)
                               deviceId 1.3.6.1.4.1.3582.4.1.5.2.1.2
Enclosure device Id.
                               enclosureIndex 1.3.6.1.4.1.3582.4.1.5.2.1.3
Firmware internal enclosure index
                               slotCount 1.3.6.1.4.1.3582.4.1.5.2.1.4
Number of slots
                               psCount 1.3.6.1.4.1.3582.4.1.5.2.1.5
Number of power supplies
                               fanCount 1.3.6.1.4.1.3582.4.1.5.2.1.6
Number of fans
                               tempSensorCount 1.3.6.1.4.1.3582.4.1.5.2.1.7
Number of temperature sensors
                               alarmCount 1.3.6.1.4.1.3582.4.1.5.2.1.8
Number of alarms
                               simCount 1.3.6.1.4.1.3582.4.1.5.2.1.9
Number of SIM modules
                               isFault 1.3.6.1.4.1.3582.4.1.5.2.1.10
Enclosure has entered a FAULT state or not. Values: false(0),true(1)
                               pdCount 1.3.6.1.4.1.3582.4.1.5.2.1.11
Number of physical drives present
                               pdIds 1.3.6.1.4.1.3582.4.1.5.2.1.12
Physical drive deviceIds space separated.
                               adapterID-ET 1.3.6.1.4.1.3582.4.1.5.2.1.13
Adapter ID.
                               pdCountSpinup60 1.3.6.1.4.1.3582.4.1.5.2.1.14
Number of drives that can spun up in 60 sec.
                               enclosureType 1.3.6.1.4.1.3582.4.1.5.2.1.15
Information about type of enclosure : 0= UNKNOWN ,1= SAFTE ,2=SES ,3= SGPIO.
                               enclFirmwareVersion 1.3.6.1.4.1.3582.4.1.5.2.1.16
Information about enclosure FW Version
                               enclSerialNumber 1.3.6.1.4.1.3582.4.1.5.2.1.17
Enclosure Serial Number
                               vendorID 1.3.6.1.4.1.3582.4.1.5.2.1.18
Enclosure Vendor ID
                               productID 1.3.6.1.4.1.3582.4.1.5.2.1.19
Enclosure Product ID
                               eSMSerialNumber 1.3.6.1.4.1.3582.4.1.5.2.1.20
IBM Enclosure ESM Serial Number
                               eSMFRU 1.3.6.1.4.1.3582.4.1.5.2.1.21
Information about IBM Enclosure ESM FRU
                               enclosureZoningMode 1.3.6.1.4.1.3582.4.1.5.2.1.22
Enclosure IBM Zoning Mode
                               eSMFRUPartInfo 1.3.6.1.4.1.3582.4.1.5.2.1.23
Information about IBM Enclosure ESM FRU Part
                       enclosureFanTable 1.3.6.1.4.1.3582.4.1.5.3
A List of fan Entries containing Information/Properties about the enclosureFan.
                           enclosureFanEntry 1.3.6.1.4.1.3582.4.1.5.3.1
An Entry in the enclosureFan table.
                               fanID 1.3.6.1.4.1.3582.4.1.5.3.1.1
ID for this EnclosureFan.(Unique)
                               enclosureId 1.3.6.1.4.1.3582.4.1.5.3.1.2
Enclosure ID where the fan is attached
                               fanStatus 1.3.6.1.4.1.3582.4.1.5.3.1.3
status of the fan
                       enclosureSlotTable 1.3.6.1.4.1.3582.4.1.5.4
A List of slot Entries containing Information/Properties about the enclosure slots.
                           enclosureSlotEntry 1.3.6.1.4.1.3582.4.1.5.4.1
An Entry in the enclosureSlot table.
                               slotID 1.3.6.1.4.1.3582.4.1.5.4.1.1
ID for this slot.(Unique)
                               enclosureId-EST 1.3.6.1.4.1.3582.4.1.5.4.1.2
enclosure ID
                               slotStatus 1.3.6.1.4.1.3582.4.1.5.4.1.3
status of the device
                       enclosurePowerSupplyTable 1.3.6.1.4.1.3582.4.1.5.5
A List of powerSupply Entries containing Information/Properties about the enclosure powerSupply
                           enclosurePowerSupplyEntry 1.3.6.1.4.1.3582.4.1.5.5.1
An Entry in the powerSupply table.
                               powerSupplyID 1.3.6.1.4.1.3582.4.1.5.5.1.1
ID for this powerSupply.(Unique)
                               enclosureId-EPST 1.3.6.1.4.1.3582.4.1.5.5.1.2
Enclosure id for the powerSupply
                               powerSupplyStatus 1.3.6.1.4.1.3582.4.1.5.5.1.3
Status of the power Supply
                       enclosureTempSensorTable 1.3.6.1.4.1.3582.4.1.5.6
A List of TempSensor Entries containing Information/Properties about the enclosure TempSensor
                           enclosureTempSensorEntry 1.3.6.1.4.1.3582.4.1.5.6.1
An Entry in the adapter table.
                               tempSensorID 1.3.6.1.4.1.3582.4.1.5.6.1.1
ID for this TempSensor.(Unique)
                               enclosureId-ETST 1.3.6.1.4.1.3582.4.1.5.6.1.2
Enclosure id for this TempSensor
                               tempSensorStatus 1.3.6.1.4.1.3582.4.1.5.6.1.3
Status of the Temparature Sensor
                               enclosureTemperature 1.3.6.1.4.1.3582.4.1.5.6.1.4
Current temperature in degree Centigrade
                       enclosureAlarmTable 1.3.6.1.4.1.3582.4.1.5.7
A List of Alarm Entries containing Information/Properties about enclosure Alarms
                           enclosureAlarmEntry 1.3.6.1.4.1.3582.4.1.5.7.1
An Entry in the enclosureAlarm table.
                               alarmID 1.3.6.1.4.1.3582.4.1.5.7.1.1
ID for this Alarm.(Unique)
                               enclosureId-EAT 1.3.6.1.4.1.3582.4.1.5.7.1.2
Enclosure id where the Alarm is attached
                               alarmStatus 1.3.6.1.4.1.3582.4.1.5.7.1.3
Status of the alarm
                       enclosureSIMTable 1.3.6.1.4.1.3582.4.1.5.8
A List of SIM Entries containing Information/Properties about enclosure SIMs
                           enclosureSIMEntry 1.3.6.1.4.1.3582.4.1.5.8.1
An Entry in the enclosureSIM table.
                               simID 1.3.6.1.4.1.3582.4.1.5.8.1.1
ID for this SIM.(Unique)
                               enclosureId-ESIT 1.3.6.1.4.1.3582.4.1.5.8.1.2
Inclosure ID where the SIM is attached
                               simStatus 1.3.6.1.4.1.3582.4.1.5.8.1.3
Status of the SIM
                   adapterTraps 1.3.6.1.4.1.3582.4.1.6
                           adpAlarmStateEnabled 1.3.6.1.4.1.3582.4.1.6.0.8001
Alarm has been enabled by user for Adapter $1
                           adpBGIRateChanged 1.3.6.1.4.1.3582.4.1.6.0.8002
Background initialization rate changed to $1 for Adapter $2
                           adpCacheDiscarded 1.3.6.1.4.1.3582.4.1.6.0.8003
Controller $1 cache discarded due to memory/battery problems
                           adpCacheRebootCantRecover 1.3.6.1.4.1.3582.4.1.6.0.8004
Unable to recover cache data due to configuration mismatch for Adapter $1
                           adpCacheRebootRecover 1.3.6.1.4.1.3582.4.1.6.0.8005
Cache data recovered successfully for Adapter $1
                           adpCacheVersionMismatch 1.3.6.1.4.1.3582.4.1.6.0.8006
Controller cache discarded due to firmware version incompatibility for Adapter $1
                           adpCCRateChanged 1.3.6.1.4.1.3582.4.1.6.0.8007
Consistency Check rate changed to $1 for Adapter $2
                           adpFlashBadImage 1.3.6.1.4.1.3582.4.1.6.0.8008
Flash downloaded image corrupted for Adapter $1
                           adpFlashEraseError 1.3.6.1.4.1.3582.4.1.6.0.8009
Flash erase error for Adapter $1
                           adpFlashEraseTimeout 1.3.6.1.4.1.3582.4.1.6.0.8010
Flash timeout during erase for Adapter $1
                           adpFlashGeneralError 1.3.6.1.4.1.3582.4.1.6.0.8011
Flash error for Adapter $1
                           adpFlashImage 1.3.6.1.4.1.3582.4.1.6.0.8012
Flashing image: $1 for Adapter $2
                           adpFlashOK 1.3.6.1.4.1.3582.4.1.6.0.8013
Flash of new firmware image(s)complete for Adapter $1
                           adpFlashProgramError 1.3.6.1.4.1.3582.4.1.6.0.8014
Flash programming error for Adapter $1
                           adpFlashProgramTimeout 1.3.6.1.4.1.3582.4.1.6.0.8015
Flash timeout during programming for Adapter $1
                           adpLogCleared 1.3.6.1.4.1.3582.4.1.6.0.8016
Event log cleared for Adapter $1
                           adpLogWrapped 1.3.6.1.4.1.3582.4.1.6.0.8017
Event log wrapped for Adapter $1
                           adpPatrolReadComplete 1.3.6.1.4.1.3582.4.1.6.0.8018
Patrol Read complete for Adapter $1
                           adpPatrolReadPaused 1.3.6.1.4.1.3582.4.1.6.0.8019
Patrol Read paused for Adapter $1
                           adpPatrolReadResumed 1.3.6.1.4.1.3582.4.1.6.0.8020
Patrol Read resumed for Adapter $1
                           adpPatrolReadStarted 1.3.6.1.4.1.3582.4.1.6.0.8021
Patrol Read started for Adapter $1
                           adpShutdown 1.3.6.1.4.1.3582.4.1.6.0.8022
Shutdown command received for Adapter $1
                           adpHibernate 1.3.6.1.4.1.3582.4.1.6.0.8023
Hibernate command received for Adapter $1
                           adpCrash 1.3.6.1.4.1.3582.4.1.6.0.8024
Fatal error received for Adapter $1
                           adpRRChanged 1.3.6.1.4.1.3582.4.1.6.0.8025
Rebuild rate changed to $1 for Adapter $2
                           adpPRRateChanged 1.3.6.1.4.1.3582.4.1.6.0.8026
Patrol Read rate changed to $1 for Adapter $2
                           adpAlarmStateDisabled 1.3.6.1.4.1.3582.4.1.6.0.8027
Alarm has been disabled by user for Adapter $1
                           adpConfigCleared 1.3.6.1.4.1.3582.4.1.6.0.8028
Configuration cleared for Adapter $1
                           adpReconRateChanged 1.3.6.1.4.1.3582.4.1.6.0.8029
Reconstruction rate changed to $1 for Adapter $2
                           adpDefault 1.3.6.1.4.1.3582.4.1.6.0.8030
Factory defaults restored for Adapter $1
                           bbuPresent 1.3.6.1.4.1.3582.4.1.6.0.8031
Battery Present for Adapter $1
                           bbuNotPresent 1.3.6.1.4.1.3582.4.1.6.0.8032
Battery Not Present for Adapter $1
                           bbuNewBattery 1.3.6.1.4.1.3582.4.1.6.0.8033
New Battery Detected for Adapter $1
                           bbuReplaced 1.3.6.1.4.1.3582.4.1.6.0.8034
Battery has been replaced for Adapter $1
                           bbuTempHigh 1.3.6.1.4.1.3582.4.1.6.0.8035
Battery temperature is high for Adapter $1
                           bbuVoltageLow 1.3.6.1.4.1.3582.4.1.6.0.8036
Battery voltage low for Adapter $1
                           bbuCharging 1.3.6.1.4.1.3582.4.1.6.0.8037
Battery started charging for Adapter $1
                           bbuDisCharging 1.3.6.1.4.1.3582.4.1.6.0.8038
Battery is discharging for Adapter $1
                           bbuTempNormal 1.3.6.1.4.1.3582.4.1.6.0.8039
Battery temperature is normal for Adapter $1
                           bbuReplace 1.3.6.1.4.1.3582.4.1.6.0.8040
Battery needs replacement, SOH Bad for Adapter $1
                           bbuRelearnStarted 1.3.6.1.4.1.3582.4.1.6.0.8041
Battery relearn started for Adapter $1
                           bbuRelearnProgress 1.3.6.1.4.1.3582.4.1.6.0.8042
Battery relearn in progress for Adapter $1
                           bbuRelearnComplete 1.3.6.1.4.1.3582.4.1.6.0.8043
Battery relearn completed for Adapter $1
                           bbuRelearnTimeout 1.3.6.1.4.1.3582.4.1.6.0.8044
Battery relearn timed out for Adapter $1
                           bbuRelearnPending 1.3.6.1.4.1.3582.4.1.6.0.8045
Battery relearn pending: Battery is under charge for Adapter $1
                           bbuRelearnPostponed 1.3.6.1.4.1.3582.4.1.6.0.8046
Battery relearn postponed for Adapter $1
                           bbuRemoved 1.3.6.1.4.1.3582.4.1.6.0.8047
Battery removed for Adapter $1
                           bbuCapacityLow 1.3.6.1.4.1.3582.4.1.6.0.8048
Current capacity of the battery is below threshold for Adapter $1
                           bbuCapacityAbove 1.3.6.1.4.1.3582.4.1.6.0.8049
Current capacity of the battery is above threshold for Adapter $1
                           bbuFRU 1.3.6.1.4.1.3582.4.1.6.0.8050
Bbu FRU for Adapter $1 changed
                           revisionIdentifier 1.3.6.1.4.1.3582.4.1.6.0.8051
Revision Identifier for Adapter $1 changed
                           adpLockKeyCreated 1.3.6.1.4.1.3582.4.1.6.0.8052
Drive security key created for Adapter $1
                           adpLockKeyBackedup 1.3.6.1.4.1.3582.4.1.6.0.8053
Drive security key backed up for Adapter $1
                           adpLockKeyVerifiedEscrow 1.3.6.1.4.1.3582.4.1.6.0.8054
Drive security key from escrow, verified for Adapter $1
                           adpLockKeyRekeyed 1.3.6.1.4.1.3582.4.1.6.0.8055
Drive security key changed for Adapter $1
                           adpLockKeyRekeyFailed 1.3.6.1.4.1.3582.4.1.6.0.8056
Drive security key, re-key operation failed for Adapter $1
                           adpLockKeyInvalid 1.3.6.1.4.1.3582.4.1.6.0.8057
Drive security key is invalid for Adapter $1
                           adpLockKeyDestroyed 1.3.6.1.4.1.3582.4.1.6.0.8058
Drive security key destroyed for Adapter $1
                           adpEscrowKeyInvalid 1.3.6.1.4.1.3582.4.1.6.0.8059
Drive security key from escrow is invalid for Adapter $1
                           adpLockKeyFailed 1.3.6.1.4.1.3582.4.1.6.0.8060
Drive security key failure, cannot access secured configuration for Adapter $1
                           bbuChargeDisabled 1.3.6.1.4.1.3582.4.1.6.0.8061
Battery charging was suspended due to high battery temperature on Adapter $1
                           bbuMicrocodeUpdated 1.3.6.1.4.1.3582.4.1.6.0.8062
Battery NVCache firmware update was successful on Adapter $1
                           bbuMicrocodeUpdateFailed 1.3.6.1.4.1.3582.4.1.6.0.8063
Battery NVCache firmware update failed on Adapter $1
                           haNodeJoin 1.3.6.1.4.1.3582.4.1.6.0.8064
Peer controller entered HA Domain at Adapter -$1
                           haNodeBreak 1.3.6.1.4.1.3582.4.1.6.0.8065
Peer controller exited HA Domain at Adapter -$1
                           haPeerIncompatible 1.3.6.1.4.1.3582.4.1.6.0.8066
Peer controller settings are incompatible
                           haCtrlpropIncompatible 1.3.6.1.4.1.3582.4.1.6.0.8067
Controller property mismatch detected with Peer controller
                           haFWVersionMismatch 1.3.6.1.4.1.3582.4.1.6.0.8068
FW version does not match Peer controller
                           haCacheMirrorOnline 1.3.6.1.4.1.3582.4.1.6.0.8069
Cache mirroring is online
                           haCacheMirrorOffline 1.3.6.1.4.1.3582.4.1.6.0.8070
Cache mirroring is offline
                           adpPropChanged 1.3.6.1.4.1.3582.4.1.6.0.8071
Controller properties changed for Adapter $1
                           adpResetNowStart 1.3.6.1.4.1.3582.4.1.6.0.8072
Controller reset requested by host for Adapter $1
                           adpResetNowDone 1.3.6.1.4.1.3582.4.1.6.0.8073
Controller reset requested by host, completed for Adapter $1
                       atAdpNumber 1.3.6.1.4.1.3582.4.1.6.1001
Adapter ID for which Trap is generated.
                       atAlarmState 1.3.6.1.4.1.3582.4.1.6.1002
Alarm disabled/enabled. Values: disabled(0),enabled(1)
                       atRate 1.3.6.1.4.1.3582.4.1.6.1003
BGI/Check Consistency/Rebuild/Patrol Read/Reconstruction Rate
                       atFlashImageName 1.3.6.1.4.1.3582.4.1.6.1004
Flash Image Name
                       atID 1.3.6.1.4.1.3582.4.1.6.1005
ID
                       clustCtrlpropReset 1.3.6.1.4.1.3582.4.1.6.1006
Resetting controller property
                   vdTraps 1.3.6.1.4.1.3582.4.1.7
                           vdtBGIAborted 1.3.6.1.4.1.3582.4.1.7.0.8101
BGI aborted on Adapter -$1 VD Target -$2 Remote VD -$3
                           vdtBGICompleted 1.3.6.1.4.1.3582.4.1.7.0.8102
BGI completed on Adapter -$1 VD Target -$2 Remote VD -$3
                           vdtBGIDoneWR 1.3.6.1.4.1.3582.4.1.7.0.8103
BGI completed with uncorrectable errors on Adapter -$1 VD Target -$2 Remote VD -$3
                           vdtBGIFailed 1.3.6.1.4.1.3582.4.1.7.0.8104
BGI failed on Adapter -$1 VD Target -$2 Remote VD -$3
                           vdtBGIStarted 1.3.6.1.4.1.3582.4.1.7.0.8105
BGI started on Adapter -$1 VD Target -$2 Remote VD -$3
                           vdtCCStarted 1.3.6.1.4.1.3582.4.1.7.0.8107
CC started on Adapter -$1 VD Target -$2 Remote VD -$3
                           vdtCCCompleted 1.3.6.1.4.1.3582.4.1.7.0.8108
CC completed on Adapter -$1 VD Target -$2 Remote VD -$3
                           vdtCCFailed 1.3.6.1.4.1.3582.4.1.7.0.8109
CC failed on Adapter -$1 VD Target -$2 Remote VD -$3
                           vdtCCAborted 1.3.6.1.4.1.3582.4.1.7.0.8110
CC aborted on Adapter -$1 VD Target -$2 Remote VD -$3
                           vdtCCCompCor 1.3.6.1.4.1.3582.4.1.7.0.8111
CC completed with correction on Adapter -$1 VD Target -$2 Remote VD -$3
                           vdtInitAborted 1.3.6.1.4.1.3582.4.1.7.0.8112
Initialization aborted on Adapter -$1 VD Target -$2 Remote VD -$3
                           vdtInitFailed 1.3.6.1.4.1.3582.4.1.7.0.8113
Initialization failed on Adapter -$1 VD Target -$2 Remote VD -$3
                           vdtInitCompleted 1.3.6.1.4.1.3582.4.1.7.0.8114
Initialization completed on Adapter -$1 VD Target -$2 Remote VD -$3
                           vdtInitFastStarted 1.3.6.1.4.1.3582.4.1.7.0.8115
Fast Initialization started on Adapter -$1 VD Target -$2 Remote VD -$3
                           vdtInitFullStarted 1.3.6.1.4.1.3582.4.1.7.0.8116
Full Initialization started on Adapter-$1 VD Target-$2 Remote VD -$3
                           vdtReconStarted 1.3.6.1.4.1.3582.4.1.7.0.8117
Reconstruction started on Adapter-$1 VD Target-$2 Remote VD -$3
                           vdtReconCompleted 1.3.6.1.4.1.3582.4.1.7.0.8118
Reconstruction completed on Adapter -$1 VD Target -$2 Remote VD -$3
                           vdtReconResumed 1.3.6.1.4.1.3582.4.1.7.0.8119
Reconstruction resumed on Adapter -$1 VD Target -$2 Remote VD -$3
                           vdtReconStopped 1.3.6.1.4.1.3582.4.1.7.0.8120
Reconstruction stopped on Adapter-$1 VD Target-$2 Remote VD -$3
                           vdtStateChange 1.3.6.1.4.1.3582.4.1.7.0.8121
VD state changed on Adapter -$1 VD Target -$2 from $3 to $4
                           vdtCreated 1.3.6.1.4.1.3582.4.1.7.0.8122
A new VD created on Adapter -$1 VD Target -$2 Remote VD -$3
                           vdtDeleted 1.3.6.1.4.1.3582.4.1.7.0.8123
A VD deleted on Adapter -$1 VD Target -$2 Remote VD -$3
                           vdtSecured 1.3.6.1.4.1.3582.4.1.7.0.8124
VD is now secured. Adapter -$1 VD Targt -$2 Remote VD -$3
                           vdtPartiallySecured 1.3.6.1.4.1.3582.4.1.7.0.8125
VD is partially secured. Adapter -$1 VD Targt -$2 Remote VD -$3
                           vdtBbmLogCleared 1.3.6.1.4.1.3582.4.1.7.0.8126
VD bad block table cleared on Adapter -$1 VD Targt -$2 Remote VD -$3
                           vdtERASEAborted 1.3.6.1.4.1.3582.4.1.7.0.8127
LD Erase aborted on aborted on Adapter -$1 VD Target -$2 Remote VD -$3
                           vdtERASECompleted 1.3.6.1.4.1.3582.4.1.7.0.8128
LD Erase completed on Adapter -$1 VD Target -$2 Remote VD -$3
                           vdtERASEFailed 1.3.6.1.4.1.3582.4.1.7.0.8129
LD Erase failed on Adapter -$1 VD Target -$2 Remote VD -$3
                           vdtERASEStarted 1.3.6.1.4.1.3582.4.1.7.0.8130
LD Erase started on Adapter -$1 VD Target -$2 Remote VD -$3
                           vdtSSCDISASSOCIATEStarted 1.3.6.1.4.1.3582.4.1.7.0.8131
CacheCade(TM) disassociate started on Adapter -$1 VD Target -$2 Remote VD -$3
                           vdtSSCDISASSOCIATECompleted 1.3.6.1.4.1.3582.4.1.7.0.8132
CacheCade(TM) disassociate completed on Adapter -$1 VD Target -$2 Remote VD -$3
                           vdtSSCDISASSOCIATEFailed 1.3.6.1.4.1.3582.4.1.7.0.8133
CacheCade(TM) disassociate failed on Adapter -$1 VD Target -$2 Remote VD -$3
                           vdtSSCDISASSOCIATEAborted 1.3.6.1.4.1.3582.4.1.7.0.8134
CacheCade(TM) disassociate aborted by user on Adapter -$1 VD Target -$2 Remote VD -$3
                           vdtACCESSBLOCKEDSSCOFFLINE 1.3.6.1.4.1.3582.4.1.7.0.8135
Access blocked as cached data in CacheCade(TM) is unavailable on Adapter -$1 VD Target -$2 Remote VD -$3
                           haLDIsRemote 1.3.6.1.4.1.3582.4.1.7.0.8136
Peer controller now manages LD on Adapter -$1 VD Target -$2 Remote VD -$3
                           haLDIsLocal 1.3.6.1.4.1.3582.4.1.7.0.8137
Local controller now manages VD on Adapter -$1 VD Target -$2 Remote VD -$3
                           haLDTargetIDConflict 1.3.6.1.4.1.3582.4.1.7.0.8138
Target ID conflict detected. VD on Adapter -$1 VD Target -$2 Remote VD -$3 access is restricted from Peer controller
                           haLDAccessShared 1.3.6.1.4.1.3582.4.1.7.0.8139
Shared access set for VD on Adapter -$1 VD Target -$2 Remote VD -$3
                           haLDAccessExclusive 1.3.6.1.4.1.3582.4.1.7.0.8140
Exclusive access set for VD on Adapter -$1 VD Target -$2 Remote VD -$3
                           haLDIncompatible 1.3.6.1.4.1.3582.4.1.7.0.8141
Adapter -$1 VD Target -$2 Remote VD -$3 is incompatible in the HA domain
                           vdAccessBlockedPeerUnavailable 1.3.6.1.4.1.3582.4.1.7.0.8142
Cached data from peer controller is unavailable. LD on Adapter -$1 VD Target -$2 Remote VD -$3 access policy is set to Blocked
                       vdNumber 1.3.6.1.4.1.3582.4.1.7.1101
vd Target ID for which Trap is generated.
                       vdSeq 1.3.6.1.4.1.3582.4.1.7.1102
vd Sequence no for which Trap is generated.
                       vdProg 1.3.6.1.4.1.3582.4.1.7.1103
progress %
                       vdCachePolicyChangeReason 1.3.6.1.4.1.3582.4.1.7.1104
VD cache policy.
                       vdNewState 1.3.6.1.4.1.3582.4.1.7.1105
Virtual Drive state. Values are: offline(0),partially-degraded(1),degraded(2),optimal(3)
                       vdOldState 1.3.6.1.4.1.3582.4.1.7.1106
Virtual Drive state. Values are: offline(0),partially-degraded(1),degraded(2),optimal(3)
                       isRemote 1.3.6.1.4.1.3582.4.1.7.1107
HA cluster locale: 0=local, 1=remote (at peer)
                       vdOldAccessPolicy 1.3.6.1.4.1.3582.4.1.7.1108
Virtual Drive access policy. Values are: read/write(0), read-only(2), blocked(3), transport-ready(14), hidden(15)
                       vdNewAccessPolicy 1.3.6.1.4.1.3582.4.1.7.1109
Virtual Drive access policy. Values are: read/write(0), read-only(2), blocked(3), transport-ready(14), hidden(15)
                       vdOldAutoSnapshot 1.3.6.1.4.1.3582.4.1.7.1110
Virtual Drive auto snapshot. Values are: enabled(1), disabled(0)
                       vdNewAutoSnapshot 1.3.6.1.4.1.3582.4.1.7.1111
Virtual Drive auto snapshot. Values are: enabled(1), disabled(0)
                       vdOldcacheBypassIOSize 1.3.6.1.4.1.3582.4.1.7.1112
Virtual Drive cache bypass IO size. Values are: 64k(0), 128k(1), 256k(2)
                       vdNewcacheBypassIOSize 1.3.6.1.4.1.3582.4.1.7.1113
Virtual Drive cache bypass IO size. Values are: 64k(0), 128k(1), 256k(2)
                       vdOldcacheBypassMode 1.3.6.1.4.1.3582.4.1.7.1114
Virtual Drive cache bypass mode. Values are: intelligent(0), standard(1), custom_mode_1(2), custom_mode_2(3), custom_mode_3(4), reserved_mode_1(5), reserved_mode_2(6), disable(7)
                       vdNewcacheBypassMode 1.3.6.1.4.1.3582.4.1.7.1115
Virtual Drive cache bypass mode. Values are: intelligent(0), standard(1), custom_mode_1(2), custom_mode_2(3), custom_mode_3(4), reserved_mode_1(5), reserved_mode_2(6), disable(7)
                       vdOldcurrentCachePolicy 1.3.6.1.4.1.3582.4.1.7.1116
Virtual Drive current cache policy. Values are: write-back(1), write-adaptive(2), read-ahead(4), read-adaptive(8), write-cache-bad-bbu(16), allow-write-cache(32), allow-read-cache(64)
                       vdNewcurrentCachePolicy 1.3.6.1.4.1.3582.4.1.7.1117
Virtual Drive current cache policy. Values are: write-back(1), write-adaptive(2), read-ahead(4), read-adaptive(8), write-cache-bad-bbu(16), allow-write-cache(32), allow-read-cache(64)
                       vdOldcurrentPSPolicy 1.3.6.1.4.1.3582.4.1.7.1118
Virtual Drive current powersave policy. Values are: ctrl-default(0), auto(1), max(2), no-cache(4), t10(8), none(254), reserved(255)
                       vdNewcurrentPSPolicy 1.3.6.1.4.1.3582.4.1.7.1119
Virtual Drive current powersave policy. Values are: ctrl-default(0), auto(1), max(2), no-cache(4), t10(8), none(254), reserved(255)
                       vdOlddefaultCachePolicy 1.3.6.1.4.1.3582.4.1.7.1120
Virtual Drive default cache policy. Values are: write-back(1), write-adaptive(2), read-ahead(4), read-adaptive(8), write-cache-bad-bbu(16), allow-write-cache(32), allow-read-cache(64)
                       vdNewdefaultCachePolicy 1.3.6.1.4.1.3582.4.1.7.1121
Virtual Drive default cache policy. Values are: write-back(1), write-adaptive(2), read-ahead(4), read-adaptive(8), write-cache-bad-bbu(16), allow-write-cache(32), allow-read-cache(64)
                       vdOlddefaultPSPolicy 1.3.6.1.4.1.3582.4.1.7.1122
Virtual Drive default powersave policy. Values are: ctrl-default(0), auto(1), max(2), no-cache(4), t10(8), none(254), reserved(255)
                       vdNewdefaultPSPolicy 1.3.6.1.4.1.3582.4.1.7.1123
Virtual Drive default powersave policy. Values are: ctrl-default(0), auto(1), max(2), no-cache(4), t10(8), none(254), reserved(255)
                       vdOlddisableAutoDeleteOldestPIT 1.3.6.1.4.1.3582.4.1.7.1124
Virtual drive disable auto delete oldest pit. Values are: enabled(1), disabled(0)
                       vdNewdisableAutoDeleteOldestPIT 1.3.6.1.4.1.3582.4.1.7.1125
Virtual Drive disable auto delete oldest pit. Values are: enabled(1), disabled(0)
                       vdOlddiskCachePolicy 1.3.6.1.4.1.3582.4.1.7.1126
Virtual Drive disk cache policy. Values are: unchanged(0), enabled(1), disabled(2)
                       vdNewdiskCachePolicy 1.3.6.1.4.1.3582.4.1.7.1127
Virtual Drive disk cache policy. Values are: unchanged(0), enabled(1), disabled(2)
                       vdOldemulationType 1.3.6.1.4.1.3582.4.1.7.1128
Virtual Drive emulation type. Values are: default(0), disabled(1)
                       vdNewemulationType 1.3.6.1.4.1.3582.4.1.7.1129
Virtual Drive emulation type. Values are: default(0), disabled(1)
                       vdOldenabledAtomicityType 1.3.6.1.4.1.3582.4.1.7.1130
Virtual Drive enabled automicity type. Values are: disabled(0), write-all(1), write-t10(2)
                       vdNewenabledAtomicityType 1.3.6.1.4.1.3582.4.1.7.1131
Virtual Drive enabled automicity type. Values are: disabled(0), write-all(1), write-t10(2)
                       vdOldexclusiveAccess 1.3.6.1.4.1.3582.4.1.7.1132
Virtual Drive exclusive access. Values are: true(1), false(0)
                       vdNewexclusiveAccess 1.3.6.1.4.1.3582.4.1.7.1133
Virtual Drive exclusive access. Values are: true(1), false(0)
                       vdOldforceEmulation 1.3.6.1.4.1.3582.4.1.7.1134
Virtual Drive force emulation. Values are: set(1), not-set(0)
                       vdNewforceEmulation 1.3.6.1.4.1.3582.4.1.7.1135
Virtual Drive force emulation. Values are: set(1), not-set(0)
                       vdOldnoBGI 1.3.6.1.4.1.3582.4.1.7.1138
Virtual Drive set no BGI. Values are: 1(disabled), 0 (enabled)
                       vdNewnoBGI 1.3.6.1.4.1.3582.4.1.7.1139
Virtual Drive set no BGI. Values are: 1(disabled), 0 (enabled)
                       vdOldscsiUnmapEnabled 1.3.6.1.4.1.3582.4.1.7.1140
Virtual Drive SCSI unmap enabled. Values are: 0(disabled), 1(enabled)
                       vdNewscsiUnmapEnabled 1.3.6.1.4.1.3582.4.1.7.1141
Virtual Drive SCSI unmap enabled. Values are: 0(disabled), 1(enabled)
                       vdOldSSCWriteBuferMode 1.3.6.1.4.1.3582.4.1.7.1142
Virtual Drive SSC write buffer mode. Values are: 0(disabled), 1(enabled)
                       vdNewSSCWriteBuferMode 1.3.6.1.4.1.3582.4.1.7.1143
Virtual Drive SSC write buffer mode. Values are: 0(disabled), 1(enabled)
                   pdTraps 1.3.6.1.4.1.3582.4.1.8
                           pdtClearAborted 1.3.6.1.4.1.3582.4.1.8.0.8201
Physical Drive Clear aborted on Adapter -$1 Dev -$2 Enc -$3 Slot -$4
                           pdtClearFailed 1.3.6.1.4.1.3582.4.1.8.0.8202
Physical Drive Clear failed on Adapter -$1 Dev -$2 Enc -$3 Slot -$4
                           pdtClearStarted 1.3.6.1.4.1.3582.4.1.8.0.8203
Physical Drive Clear started on Adapter -$1 Dev -$2 Enc -$3 Slot -$4
                           pdtClearCompleted 1.3.6.1.4.1.3582.4.1.8.0.8204
Physical Drive Clear completed on Adapter -$1 Dev -$2 Enc -$3 Slot -$4
                           pdtError 1.3.6.1.4.1.3582.4.1.8.0.8205
Error occurred on Adapter -$1 Dev -$2 Enc -$3 Slot -$4
                           pdtFormatStart 1.3.6.1.4.1.3582.4.1.8.0.8206
Physical Drive format started on Adapter -$1 Dev -$2 Enc -$3 Slot -$4
                           pdtFormatCompleted 1.3.6.1.4.1.3582.4.1.8.0.8207
Physical Drive format completed on Adapter -$1 Dev -$2 Enc -$3 Slot -$4
                           pdtInserted 1.3.6.1.4.1.3582.4.1.8.0.8208
PD inserted on Adapter -$1 Dev -$2 Enc -$3 Slot -$4
                           pdtRblAborted 1.3.6.1.4.1.3582.4.1.8.0.8209
Rebuild aborted on Adapter -$1 Dev -$2 Enc -$3 Slot -$4
                           pdtRblCompleted 1.3.6.1.4.1.3582.4.1.8.0.8210
Rebuild completed on Adapter -$1 Dev -$2 Enc -$3 Slot -$4
                           pdtRblFailedBS 1.3.6.1.4.1.3582.4.1.8.0.8211
Rebuild failed(bad source) on Adapter -$1 Dev -$2 Enc -$3 Slot -$4
                           pdtRblFailedBT 1.3.6.1.4.1.3582.4.1.8.0.8212
Rebuild failed(bad target) on Adapter -$1 Dev -$2 Enc -$3 Slot -$4
                           pdtRblStart 1.3.6.1.4.1.3582.4.1.8.0.8213
Rebuild started on Adapter -$1 Dev -$2 Enc -$3 Slot -$4
                           pdtRblResumed 1.3.6.1.4.1.3582.4.1.8.0.8214
Rebuild resumed on Adapter -$1 Dev -$2 Enc -$3 Slot -$4
                           pdtRblStartA 1.3.6.1.4.1.3582.4.1.8.0.8215
Rebuild started(auto) on Adapter -$1 Dev -$2 Enc -$3 Slot -$4
                           pdtRemoved 1.3.6.1.4.1.3582.4.1.8.0.8216
Physical Drive removed on Adapter -$1 Dev -$2 Enc -$3 Slot -$4
                           pdtStateChange 1.3.6.1.4.1.3582.4.1.8.0.8217
PD state changed on Adapter -$1 Dev -$2 Enc -$3 Slot -$4 from $5 to $6
                           pdtRedundantPathBroken 1.3.6.1.4.1.3582.4.1.8.0.8218
Redundant Path Broken For Physical Drive on Adapter -$1 Dev -$2 Enc -$3 Slot -$4 EncDevId -$5 pdSAS -$6
                           pdtRedundantPathRestored 1.3.6.1.4.1.3582.4.1.8.0.8219
Redundant Path Restored For Physical Drive on Adapter -$1 Dev -$2 Enc -$3 Slot -$4 EncDevId -$5 pdSAS -$6
                           pdtRedundantEnclModuleInserted 1.3.6.1.4.1.3582.4.1.8.0.8220
Redundant Encl Modul Inserted on Adapter -$1 Dev -$2 Enc -$3 Slot -$4 EncDevId -$5 pdSAS -$6 pdpath -$7
                           pdtRedundantEnclModuleRemoved 1.3.6.1.4.1.3582.4.1.8.0.8221
Redundant Encl Modul Removed on Adapter -$1 Dev -$2 Enc -$3 Slot -$4 EncDevId -$5 pdSAS -$6 pdpath -$7
                           pdtFRU 1.3.6.1.4.1.3582.4.1.8.0.8222
FRU changed on Adapter -$1 Dev -$2 Enc -$3 Slot -$4 EncDevId -$5 -FRU $6
                           pdtSecured 1.3.6.1.4.1.3582.4.1.8.0.8223
PD security activated on Adapter -$1 Dev -$2 Enc -$3 Slot -$4
                           pdtUnsecured 1.3.6.1.4.1.3582.4.1.8.0.8224
PD security disabled on Adapter -$1 Dev -$2 Enc -$3 Slot -$4
                           pdtReprovisioned 1.3.6.1.4.1.3582.4.1.8.0.8225
PD is reprovisioned on Adapter -$1 Dev -$2 Enc -$3 Slot -$4
                           pdtLockKeyRekeyed 1.3.6.1.4.1.3582.4.1.8.0.8226
PD security key changed on Adapter -$1 Dev -$2 Enc -$3 Slot -$4
                           pdtSecurityFailure 1.3.6.1.4.1.3582.4.1.8.0.8227
Security subsystem problems detected on Adapter -$1 Dev -$2 Enc -$3 Slot -$4
                           pdtPowerStateChange 1.3.6.1.4.1.3582.4.1.8.0.8228
Power State Change on Adapter -$1 Dev -$2 Enc -$3 Slot -$4 NewPowerState -$5
                           pdtNotSupported 1.3.6.1.4.1.3582.4.1.8.0.8229
PD Not Supported on Adapter -$1 Dev -$2 Enc -$3 Slot -$4
                           pdtNotCertified 1.3.6.1.4.1.3582.4.1.8.0.8230
PD Not Certified on Adapter -$1 Dev -$2 Enc -$3 Slot -$4
                           pdtERASEAborted 1.3.6.1.4.1.3582.4.1.8.0.8231
PD Erase aborted on Adapter -$1 Dev -$2 Enc -$3 Slot -$4
                           pdtERASECompleted 1.3.6.1.4.1.3582.4.1.8.0.8232
PD Erase completed on Adapter -$1 Dev -$2 Enc -$3 Slot -$4
                           pdtERASEStarted 1.3.6.1.4.1.3582.4.1.8.0.8233
PD Erase started on Adapter -$1 Dev -$2 Enc -$3 Slot -$4
                           pdtERASEFailed 1.3.6.1.4.1.3582.4.1.8.0.8234
PD Erase Failed on Adapter -$1 Dev -$2 Enc -$3 Slot -$4
                           haPDIsRemote 1.3.6.1.4.1.3582.4.1.8.0.8235
Peer controller now manages PD on Adapter -$1 Dev -$2 Enc -$3 Slot -$4
                           haPDIsLocal 1.3.6.1.4.1.3582.4.1.8.0.8236
Local controller now manages PD on Adapter -$1 Dev -$2 Enc -$3 Slot -$4
                       pdID 1.3.6.1.4.1.3582.4.1.8.1201
Device ID for which Trap is generated.
                       pdEncIndex 1.3.6.1.4.1.3582.4.1.8.1202
Enclosure index(0 means not within an enclosure) for which Trap is generated.
                       pdSlotNo 1.3.6.1.4.1.3582.4.1.8.1203
Slot no for the enclosure
                       pdNewState 1.3.6.1.4.1.3582.4.1.8.1204
Physical Drive state. Values are: unconfigured-good(0),unconfigured-bad(1),hot-spare(2),offline(16),failed(17),rebuild(20),online(24),copyback(32),system(64)
                       pdOldState 1.3.6.1.4.1.3582.4.1.8.1205
Physical Drive state. Values are: unconfigured-good(0),unconfigured-bad(1),hot-spare(2),offline(16),failed(17),rebuild(20),online(24),copyback(32),system(64)
                       pdEnclDeviceId 1.3.6.1.4.1.3582.4.1.8.1206
Enclosure Device ID for which Trap is generated.
                       pdSASAdd 1.3.6.1.4.1.3582.4.1.8.1207
Device SAS addresses. Comma separeted for multiple address.
                       pdPath 1.3.6.1.4.1.3582.4.1.8.1208
PD path.
                       pdFRU 1.3.6.1.4.1.3582.4.1.8.1209
PD FRU for which trap is generated.
                       pdNewPowerState 1.3.6.1.4.1.3582.4.1.8.1210
New Power Status Of the Device.Values are device is active(0),device is stopped(1),device is transitioning between power states(255)
                   enclTraps 1.3.6.1.4.1.3582.4.1.9
                           widePortLinkLost 1.3.6.1.4.1.3582.4.1.9.0.8330
Link lost on SAS wide port on Adapter -$1 port -$2 PHY -$3
                           widePortLinkRestored 1.3.6.1.4.1.3582.4.1.9.0.8331
Link Restored on SAS wide port on Adapter -$1 port -$2 PHY -$3
                       atPort 1.3.6.1.4.1.3582.4.1.9.1301
Prot no.
                       onPHY 1.3.6.1.4.1.3582.4.1.9.1302
PHY no
                   pciTraps 1.3.6.1.4.1.3582.4.1.10
                             haHwIncompatible 1.3.6.1.4.1.3582.4.1.10.0.8501
Peer Controller hardware is incompatible
                         pciVendorId 1.3.6.1.4.1.3582.4.1.10.1501
PCI VendorID
                         pciDeviceId 1.3.6.1.4.1.3582.4.1.10.1502
PCI Device ID
                         pciSubVendorId 1.3.6.1.4.1.3582.4.1.10.1503
PCI SubVendorID
                         pciSubDeviceId 1.3.6.1.4.1.3582.4.1.10.1504
PCI SubDeviceID
                   copyrightInfo 1.3.6.1.4.1.3582.4.1.11
                         copyright 1.3.6.1.4.1.3582.4.1.11.1
LSI Corporation