LSI-MegaRAID-SAS-MIB: View SNMP OID List / Download MIB
VENDOR: LSI LOGIC
Home | MIB: LSI-MegaRAID-SAS-MIB | |||
---|---|---|---|---|
Download as: |
Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
|
|||
Object Name | OID | Type | Access | Info |
lsi | 1.3.6.1.4.1.3582 | |||
storageComponents | 1.3.6.1.4.1.3582.4 | |||
lsiRAIDServer | 1.3.6.1.4.1.3582.4.1 | |||
hostName | 1.3.6.1.4.1.3582.4.1.1 |
Name of the host system. |
||
hostOSInfo | 1.3.6.1.4.1.3582.4.1.2 |
Operating System description where SNMP agent is running. |
||
versionInfo | 1.3.6.1.4.1.3582.4.1.3 | |||
mibVersion | 1.3.6.1.4.1.3582.4.1.3.1 |
The MIB version no. (xx.yy) |
||
agentModuleName | 1.3.6.1.4.1.3582.4.1.3.2 |
The agent module name |
||
agentModuleVersion | 1.3.6.1.4.1.3582.4.1.3.3 |
The module version in xx.yy format. Where xx is the major version number and yy is the minor version number(without build information). |
||
releaseDate | 1.3.6.1.4.1.3582.4.1.3.4 |
Module Release Date |
||
megaRAID-SAS | 1.3.6.1.4.1.3582.4.1.4 | |||
adapter | 1.3.6.1.4.1.3582.4.1.4.1 | |||
adpNumber | 1.3.6.1.4.1.3582.4.1.4.1.1 |
The total no of SAS adapters present. |
||
adapterPropertiesTable | 1.3.6.1.4.1.3582.4.1.4.1.2 |
A List of adapter Entries containing Information/Properties about the adapters. |
||
1.3.6.1.4.1.3582.4.1.4.1.2.1 |
An Entry in the adapter table. |
|||
adapterID-APT | 1.3.6.1.4.1.3582.4.1.4.1.2.1.1 |
AdapterID for this Adapter.(Unique) |
||
rebuildRate | 1.3.6.1.4.1.3582.4.1.4.1.2.1.2 |
Rebuild rate on this Adapter. |
||
reconstructionRate | 1.3.6.1.4.1.3582.4.1.4.1.2.1.3 |
Reconstruction rate on this Adapter. |
||
alarmState | 1.3.6.1.4.1.3582.4.1.4.1.2.1.4 |
Alarm is enabled or disabled on this adapter. Values: disabled(0),enabled(1) |
||
cacheFlushInterval | 1.3.6.1.4.1.3582.4.1.4.1.2.1.5 |
Cache flush interval in seconds for this adapter. |
||
clusterState | 1.3.6.1.4.1.3582.4.1.4.1.2.1.6 |
Cluster is enabled or disabled on this adapter. Values: disabled(0),enabled(1) |
||
predFailPollInterval | 1.3.6.1.4.1.3582.4.1.4.1.2.1.7 |
Number of seconds between precdictive fail polls on this adapter. |
||
intThrottleCount | 1.3.6.1.4.1.3582.4.1.4.1.2.1.8 |
Interrupt throttle active count on this adapter. |
||
intThrottleTimeUs | 1.3.6.1.4.1.3582.4.1.4.1.2.1.9 |
Interrupt throttle completion hold time on this adapter. |
||
patrolReadRate | 1.3.6.1.4.1.3582.4.1.4.1.2.1.10 |
Patrol Read Rate for this adapter. |
||
bgiRate | 1.3.6.1.4.1.3582.4.1.4.1.2.1.11 |
Background initialization rate for this adapter. |
||
spinupDelay | 1.3.6.1.4.1.3582.4.1.4.1.2.1.12 |
Number of seconds to delay among spinup groups for this adapter. |
||
spinupDriveCount | 1.3.6.1.4.1.3582.4.1.4.1.2.1.13 |
Maximum number of drives to spin up at one time for this adapter. |
||
coercionMode | 1.3.6.1.4.1.3582.4.1.4.1.2.1.14 |
Drive capacity coercion mode. 0->None; 1->128MB; 2->1GB |
||
nvramSize | 1.3.6.1.4.1.3582.4.1.4.1.2.1.15 |
NVRAM size in KB for this adapter. |
||
memorySize | 1.3.6.1.4.1.3582.4.1.4.1.2.1.16 |
Memory size in MB for this adapter. |
||
flashSize | 1.3.6.1.4.1.3582.4.1.4.1.2.1.17 |
Flash size in MB for this adapter. |
||
vdPresentCount | 1.3.6.1.4.1.3582.4.1.4.1.2.1.18 |
Virtual devices present in this adapter. |
||
vdDegradedCount | 1.3.6.1.4.1.3582.4.1.4.1.2.1.19 |
Number of virtual devices in this adapter that are critical |
||
vdOfflineCount | 1.3.6.1.4.1.3582.4.1.4.1.2.1.20 |
Number of virtual devices in this adapter that are offline |
||
pdPresentCount | 1.3.6.1.4.1.3582.4.1.4.1.2.1.21 |
Physical devices present in this adapter. |
||
pdDiskPresentCount | 1.3.6.1.4.1.3582.4.1.4.1.2.1.22 |
Physical disk devices present in this adapter. |
||
pdDiskPredFailureCount | 1.3.6.1.4.1.3582.4.1.4.1.2.1.23 |
Number of disk devices in this adapter that are critical |
||
pdDiskFailedCount | 1.3.6.1.4.1.3582.4.1.4.1.2.1.24 |
Number of disk devices in this adapter that are failed |
||
ccRate | 1.3.6.1.4.1.3582.4.1.4.1.2.1.25 |
Consistency Check rate on this Adapter. |
||
compatibilityFlag | 1.3.6.1.4.1.3582.4.1.4.1.2.1.26 |
To inform compatibilities between Applications and FW. 0->incompatible; 1->compatible |
||
compatibilityInfo | 1.3.6.1.4.1.3582.4.1.4.1.2.1.27 |
Compatibility Information. Format->(Firmware Forward compatibility flag:Firmware Backward compatibility flag:Firmware version flag:Application Forward compatibility flag:Application Backward compatibility flag:Application version flag) |
||
abortCConError | 1.3.6.1.4.1.3582.4.1.4.1.2.1.28 |
Abort CC on detecting error is enabled or disabled on this adapter. Values: No(0),Yes(1),NA(2) |
||
copyBackState | 1.3.6.1.4.1.3582.4.1.4.1.2.1.29 |
CopyBack is enabled or disabled on this adapter.Values: disabled(0),enabled(1) |
||
multipathSupport | 1.3.6.1.4.1.3582.4.1.4.1.2.1.31 |
Multipath is supported or not supported on this adapter.Values: not supported(0),supported(1) |
||
ssdSMARTerEnabled | 1.3.6.1.4.1.3582.4.1.4.1.2.1.32 |
Copyback to SSD on SMART error. Values Enabled(0),Disabled(1) |
||
enableSpinDownUnconfigured | 1.3.6.1.4.1.3582.4.1.4.1.2.1.33 |
Spin Down Unconfigured Drives(1), Do Not Spin Down Unconfigured Drives(0) |
||
disableSpinDownHotSpare | 1.3.6.1.4.1.3582.4.1.4.1.2.1.34 |
Spin Down Hotspares(0), Do Not Spin Down Hotspares(1) |
||
spinDownTime | 1.3.6.1.4.1.3582.4.1.4.1.2.1.35 |
SpinDownTime in minutes |
||
spinupEnclDriveCount | 1.3.6.1.4.1.3582.4.1.4.1.2.1.36 |
Maximum number of drives that can be spin up in an enclosure |
||
spinupEnclDelay | 1.3.6.1.4.1.3582.4.1.4.1.2.1.37 |
Delay between drive spin up for drives within an enclosure |
||
defaultLdPSPolicy | 1.3.6.1.4.1.3582.4.1.4.1.2.1.38 |
power saving policy.values:controller default power saving policy=0, AUTO=1, MAX=2, Max with no cache=6, NONE=255 |
||
disableLdPSInterval | 1.3.6.1.4.1.3582.4.1.4.1.2.1.39 |
LD power savings are disabled for yy hours beginning at disableLdPSTime. |
||
disableLdPSTime | 1.3.6.1.4.1.3582.4.1.4.1.2.1.40 |
LD power savings shall be disabled at xx minutes from 12:00am. |
||
supportBreakMirror | 1.3.6.1.4.1.3582.4.1.4.1.2.1.41 |
1=Support break mirror operation,0=Do not Support break mirror operation |
||
temperatureROC | 1.3.6.1.4.1.3582.4.1.4.1.2.1.42 |
temperature of RAID On Chip in Celsius |
||
temperatureCtrl | 1.3.6.1.4.1.3582.4.1.4.1.2.1.43 |
temperature of controller in Celsius |
||
preventPIImport | 1.3.6.1.4.1.3582.4.1.4.1.2.1.44 |
1=Prevent import of SAS PI protected logical disks , 0=Not Prevent import of SAS PI protected logical disks |
||
enablePI | 1.3.6.1.4.1.3582.4.1.4.1.2.1.45 |
1 = Enable SAS PI for controller , 0 = Disable SAS PI for controller |
||
totalSpaceformetadata | 1.3.6.1.4.1.3582.4.1.4.1.2.1.46 |
Total Space used for MetaData |
||
useEmergencySpare | 1.3.6.1.4.1.3582.4.1.4.1.2.1.47 |
This field give the information about Emergency Spare possible Drive types(Uncongiured Good/Global Hotspare) |
||
useEmergencySparesforSMARTer | 1.3.6.1.4.1.3582.4.1.4.1.2.1.48 |
1 = Use Emergency spares for SMARTer ,0 = Not Use Emergency spares for SMARTer |
||
supportShieldState | 1.3.6.1.4.1.3582.4.1.4.1.2.1.49 |
1 =Support PD shield state ,0 = Not Support PD shield state |
||
writeCacheCapable | 1.3.6.1.4.1.3582.4.1.4.1.2.1.50 |
1 = SSC support write caching IOs ,0 = SSC not support write caching IOs |
||
totalCacheSize | 1.3.6.1.4.1.3582.4.1.4.1.2.1.51 |
This field give the information about total Size of currently configured SSC,in GB |
||
maximumCacheSize | 1.3.6.1.4.1.3582.4.1.4.1.2.1.52 |
This field give the information about maxmium Size of SSC that can yet be configured,in GB |
||
ctrlSasAddr | 1.3.6.1.4.1.3582.4.1.4.1.2.1.53 |
This field gives the controller SAS address |
||
domainId | 1.3.6.1.4.1.3582.4.1.4.1.2.1.54 |
This field gives the Domain ID |
||
peerControllerStatus | 1.3.6.1.4.1.3582.4.1.4.1.2.1.55 |
This field gives the Peer controller Status |
||
maximumControllerNodes | 1.3.6.1.4.1.3582.4.1.4.1.2.1.56 |
This field gives the HA nodes this FW supports |
||
incompatibilityDetails | 1.3.6.1.4.1.3582.4.1.4.1.2.1.57 |
This field gives the Incompatibility Details |
||
topologyType | 1.3.6.1.4.1.3582.4.1.4.1.2.1.58 |
This field gives the Topology Type |
||
supportOnlineFWUpdate | 1.3.6.1.4.1.3582.4.1.4.1.2.1.59 |
1 = Online firmware update is supported, 0 = Online firmware update is not supported |
||
supportFastPathWB | 1.3.6.1.4.1.3582.4.1.4.1.2.1.60 |
1 = Support Fast Path WB on Raptor Type Ld ,0 = Does not support Fast Path WB on Raptor Type Ld |
||
supportConfigAutoBalance | 1.3.6.1.4.1.3582.4.1.4.1.2.1.61 |
0 = no configuration auto balance support, 1 = configuration auto balance support is present |
||
maintenanceMode | 1.3.6.1.4.1.3582.4.1.4.1.2.1.62 |
1=FW supports maintenance mode |
||
disableLargeIO | 1.3.6.1.4.1.3582.4.1.4.1.2.1.63 |
0 = Large IO is supported, 1 = Large IO is unsupported |
||
adapterInfoTable | 1.3.6.1.4.1.3582.4.1.4.1.3 |
A List of adapter Entries containing Information/Properties about the adapters on the Controller. |
||
1.3.6.1.4.1.3582.4.1.4.1.3.1 |
An Entry in the adapterInfo table. |
|||
adapterID-AIT | 1.3.6.1.4.1.3582.4.1.4.1.3.1.1 |
AdapterID for this Adapter.(Unique) |
||
adapterVendorID | 1.3.6.1.4.1.3582.4.1.4.1.3.1.2 |
PCI Vendor ID for this Adapter. |
||
devID | 1.3.6.1.4.1.3582.4.1.4.1.3.1.3 |
PCI Device ID for this Adapter. |
||
subVendorID | 1.3.6.1.4.1.3582.4.1.4.1.3.1.4 |
PCI Sub-Vendor ID for this adapter. |
||
subDevID | 1.3.6.1.4.1.3582.4.1.4.1.3.1.5 |
PCI Sub-Device ID for this adapter. |
||
hostInterface | 1.3.6.1.4.1.3582.4.1.4.1.3.1.6 |
Host interface information for this adapter. Values: N/A(0),PCIX(1),PCIE(2),iSCSI(3),SAS-3G(4) |
||
hostInterfacePortCnt | 1.3.6.1.4.1.3582.4.1.4.1.3.1.7 |
Port Count on this adapter. |
||
hostInterfacePortAddr | 1.3.6.1.4.1.3582.4.1.4.1.3.1.8 |
Port address comma delimited |
||
devInterface | 1.3.6.1.4.1.3582.4.1.4.1.3.1.9 |
Multiple device interface support values separated by space. |
||
devInterfacePortCnt | 1.3.6.1.4.1.3582.4.1.4.1.3.1.10 |
Device Port Count on this adapter. |
||
devInterfacePortAddr | 1.3.6.1.4.1.3582.4.1.4.1.3.1.11 |
Device Port address comma delimited |
||
productName | 1.3.6.1.4.1.3582.4.1.4.1.3.1.12 |
Product name e.g. MegaRAID SAS-8E, MegaRAID SAS-4X, etc. |
||
serialNo | 1.3.6.1.4.1.3582.4.1.4.1.3.1.13 |
Controller serial number |
||
firmwareVersion | 1.3.6.1.4.1.3582.4.1.4.1.3.1.14 |
Firmware version Format->(Firmware Package Version:Version:Date:Time) |
||
driverVersion | 1.3.6.1.4.1.3582.4.1.4.1.3.1.15 |
Driver version Format->(Driver Name:Version) |
||
expanderFirmwareVersion | 1.3.6.1.4.1.3582.4.1.4.1.3.1.16 |
Expander firmware version - Not Available if expander is not present on the controller |
||
lockKeyBinding | 1.3.6.1.4.1.3582.4.1.4.1.3.1.17 |
Type of lock key binding. lock key is not bound(0),lock key bound to FW secret key(1), lock key bound to user(2), lock key bound to a TPM(3) |
||
maxDAPdCountSpinup60 | 1.3.6.1.4.1.3582.4.1.4.1.3.1.18 |
Maximum number of drives to spinup within 60 sec for direct attached drives |
||
adapterSupportInfoTable | 1.3.6.1.4.1.3582.4.1.4.1.4 |
A List of adapter Entries containing Information/Properties about the adapters on the Controller. |
||
1.3.6.1.4.1.3582.4.1.4.1.4.1 |
An Entry in the adapter table. |
|||
adapterID-ASIT | 1.3.6.1.4.1.3582.4.1.4.1.4.1.1 |
AdapterID for this Adapter.(Unique) |
||
maxArms | 1.3.6.1.4.1.3582.4.1.4.1.4.1.2 |
Maximum arms per Virtual Drive supported for this Adapter. |
||
maxSpans | 1.3.6.1.4.1.3582.4.1.4.1.4.1.3 |
Maximum spans per Virtual Drive supported for this Adapter. |
||
maxArrays | 1.3.6.1.4.1.3582.4.1.4.1.4.1.4 |
Maximum no of arrays supported for this adapter. |
||
maxVDs | 1.3.6.1.4.1.3582.4.1.4.1.4.1.5 |
Maximum number of Virtual Drive s supported for this adapter. |
||
hardwarePresent | 1.3.6.1.4.1.3582.4.1.4.1.4.1.6 |
Supported Hardware on this adapter. bbu(1),alarm(2),nvram(3),uart(4),TPM(5),expander(6). For multiple hw support a space delimited list will appear. |
||
maxConcurrentCmds | 1.3.6.1.4.1.3582.4.1.4.1.4.1.7 |
The maximum parallel commands supported on this adapter. |
||
maxSGECount | 1.3.6.1.4.1.3582.4.1.4.1.4.1.8 |
The maximum Scatter Gather Element count allowed on this adapter. |
||
maxRequestSize | 1.3.6.1.4.1.3582.4.1.4.1.4.1.9 |
The maximum data transfer size in sectors, on this adapter. |
||
maxLdsPerArray | 1.3.6.1.4.1.3582.4.1.4.1.4.1.10 |
Max Lds per array in adapter |
||
partitionsInDDF | 1.3.6.1.4.1.3582.4.1.4.1.4.1.11 |
Max LDs per Array in configuration |
||
allowSSDMixInLD | 1.3.6.1.4.1.3582.4.1.4.1.4.1.12 |
allow SAS/SATA SSD mix within an LD. allow(1), not allow(0) |
||
allowMixSSDHDDInLD | 1.3.6.1.4.1.3582.4.1.4.1.4.1.13 |
allow SSD/HDD mix within an LD.allow(1), not allow(0) |
||
adapterOperationsSupportInfoTable | 1.3.6.1.4.1.3582.4.1.4.1.5 |
A List of adapter Entries containing Information/Properties about the adapters on the Controller. |
||
1.3.6.1.4.1.3582.4.1.4.1.5.1 |
An Entry in the adapter table. |
|||
adapterID | 1.3.6.1.4.1.3582.4.1.4.1.5.1.1 |
AdapterID for this Adapter.(Unique) |
||
rbldRateSupported | 1.3.6.1.4.1.3582.4.1.4.1.5.1.2 |
Rebuilding rate change support for this Adapter. Values: false(0),true(1) |
||
ccRateSupported | 1.3.6.1.4.1.3582.4.1.4.1.5.1.3 |
Consistency Check rate change support for this Adapter. Values: false(0),true(1) |
||
bgiRateSupported | 1.3.6.1.4.1.3582.4.1.4.1.5.1.4 |
Background initialization rate change support for this adapter. Values: false(0),true(1) |
||
reconRateSupported | 1.3.6.1.4.1.3582.4.1.4.1.5.1.5 |
Reconstruction rate change support for this adapter. Values: false(0),true(1) |
||
patrolRateSupported | 1.3.6.1.4.1.3582.4.1.4.1.5.1.6 |
Patrol read rate change support for this adapter. Values: false(0),true(1) |
||
alarmControlSupported | 1.3.6.1.4.1.3582.4.1.4.1.5.1.7 |
Alarm control support for this adapter. Values: false(0),true(1) |
||
clusterSupported | 1.3.6.1.4.1.3582.4.1.4.1.5.1.8 |
Cluster support for this adapter. Values: false(0),true(1) |
||
bbuSupported | 1.3.6.1.4.1.3582.4.1.4.1.5.1.9 |
BBU support for this adapter. Values: false(0),true(1) |
||
spanningAllowedSupported | 1.3.6.1.4.1.3582.4.1.4.1.5.1.10 |
Spanning support for this adapter. Values: false(0),true(1) |
||
dedicatedHotSparesSupported | 1.3.6.1.4.1.3582.4.1.4.1.5.1.11 |
Dedicated HotSpares support for this adapter. Values: false(0),true(1) |
||
revertibleHotSparesSupported | 1.3.6.1.4.1.3582.4.1.4.1.5.1.12 |
Revertible HotSpares support for this adapter. Values: false(0),true(1) |
||
foreignConfigImportSupported | 1.3.6.1.4.1.3582.4.1.4.1.5.1.13 |
Support foreign config import on this adapter. Values: false(0),true(1) |
||
selfDiagnosticSupported | 1.3.6.1.4.1.3582.4.1.4.1.5.1.14 |
Controller supports self diagnostic. Values: false(0),true(1) |
||
allowMixedRedundancyOnArraySupported | 1.3.6.1.4.1.3582.4.1.4.1.5.1.15 |
Allow different Virtual Disk on the same array to have different redundancy levels. Values: false(0),true(1) |
||
abortCConErrorSupported | 1.3.6.1.4.1.3582.4.1.4.1.5.1.16 |
Abort CC on detecting error is supported on this adapter. Values: No(0),Yes(1) |
||
securitySupported | 1.3.6.1.4.1.3582.4.1.4.1.5.1.17 |
Displays the security support. if supported (1) , not supported (0) |
||
supportPIcontroller | 1.3.6.1.4.1.3582.4.1.4.1.5.1.18 |
Displays the support PI. 1=LD SAS PI Type 0, 0=LD Not SAS PI Type 0 |
||
bbuInfo | 1.3.6.1.4.1.3582.4.1.4.1.6 | |||
bbuNumber | 1.3.6.1.4.1.3582.4.1.4.1.6.1 |
The present number of rows in the BBU Table. |
||
bbuTable | 1.3.6.1.4.1.3582.4.1.4.1.6.2 |
A List of BBU Entries containing Information/Properties about the BBU. |
||
1.3.6.1.4.1.3582.4.1.4.1.6.2.1 |
An Entry in the BBU table. |
|||
bbuID | 1.3.6.1.4.1.3582.4.1.4.1.6.2.1.1 |
BBUID for this BBU.(Unique) |
||
batteryType | 1.3.6.1.4.1.3582.4.1.4.1.6.2.1.2 |
BBU Type. |
||
nextLearnTime | 1.3.6.1.4.1.3582.4.1.4.1.6.2.1.3 |
Time of next scheduled learn cycle (seconds past 1/1/2000) |
||
absStateOfCharge | 1.3.6.1.4.1.3582.4.1.4.1.6.2.1.4 |
Predicted remaining capacity expressed as % of DesignCapacity() (0-100). Value of -1 means not supported |
||
fullChargeCapacity | 1.3.6.1.4.1.3582.4.1.4.1.6.2.1.5 |
Predicted pack capacity when it is fully charged in joules |
||
averageEmptyTime | 1.3.6.1.4.1.3582.4.1.4.1.6.2.1.6 |
One-minute rolling average of the predicted remaining battery life. Value of -1 means not supported |
||
cycleCount | 1.3.6.1.4.1.3582.4.1.4.1.6.2.1.7 |
Number of charge cycles the battery has experienced. Value of -1 means not supported |
||
firmwareStatus | 1.3.6.1.4.1.3582.4.1.4.1.6.2.1.8 |
Condition of battery in following order: packMissing(0/1) voltageLow(0/1) temperatureHigh(0/1) chargeActive(0/1) dischargeActive(0/1) learnCycleRequested(0/1) learnCycleActive(0/1) learnCycleFailed(0/1) learnCycleTimeout(0/1) i2cErrorsDetected(0/1) noSpace(0/1) predictiveFailure(0/1) premiumFeatureReqd(0/1) microcodeUpdateReqd(0/1) Only enabled(1) values will be shown |
||
voltage | 1.3.6.1.4.1.3582.4.1.4.1.6.2.1.9 |
Accurate battery terminal voltage in mV, resolution of 1mV |
||
autoLearnPeriod | 1.3.6.1.4.1.3582.4.1.4.1.6.2.1.10 |
Time (in seconds) between learn cycles (0 to disable auto learn) |
||
relStateOfCharge | 1.3.6.1.4.1.3582.4.1.4.1.6.2.1.11 |
Predicted remaining capacity expressed as % of FullChargeCapacity() (0-100). Value of -1 means not supported |
||
capacityRemain | 1.3.6.1.4.1.3582.4.1.4.1.6.2.1.12 |
Predicted charge or energy remaining in the battery in joules |
||
runTimeToEmpty | 1.3.6.1.4.1.3582.4.1.4.1.6.2.1.13 |
Relative gain or loss in remaining life in response to change in power policy represent in minute. Value of -1 means not supported |
||
avgTimeToFull | 1.3.6.1.4.1.3582.4.1.4.1.6.2.1.14 |
One-minute rolling average of predicted remaining time to full charge. Value of -1 means not supported |
||
errorMargin | 1.3.6.1.4.1.3582.4.1.4.1.6.2.1.15 |
Expected margin of error (%) in charge calculation (2-100). Value of -1 means not supported |
||
temperature | 1.3.6.1.4.1.3582.4.1.4.1.6.2.1.16 |
Battery temperature in degree Centigrade |
||
mfgName | 1.3.6.1.4.1.3582.4.1.4.1.6.2.1.17 |
Battery manufacturers name |
||
deviceName | 1.3.6.1.4.1.3582.4.1.4.1.6.2.1.18 |
Battery name |
||
serialNumber | 1.3.6.1.4.1.3582.4.1.4.1.6.2.1.19 |
Battery serialNumber |
||
chargerStatus | 1.3.6.1.4.1.3582.4.1.4.1.6.2.1.20 |
Battery charger status. Values: N/A(-1), off(0), complete(1), progress(2) |
||
adpID | 1.3.6.1.4.1.3582.4.1.4.1.6.2.1.21 |
The adapter id where BBU is attached |
||
remainingCapAlarm | 1.3.6.1.4.1.3582.4.1.4.1.6.2.1.22 |
Remaining capacity to alarm. Value of -1 means not supported |
||
remainingTimeAlarm | 1.3.6.1.4.1.3582.4.1.4.1.6.2.1.23 |
Remaining time to alarm. Value of -1 means not supported |
||
bbu-current | 1.3.6.1.4.1.3582.4.1.4.1.6.2.1.24 |
Current(In mA) being supplied (or accepted) through the battery terminals |
||
gasGaugeStatus | 1.3.6.1.4.1.3582.4.1.4.1.6.2.1.25 |
Gas gauge status |
||
batteryReplacement | 1.3.6.1.4.1.3582.4.1.4.1.6.2.1.27 |
This property denotes whether the Battery needs to be replaced or not.1 =battery needs to be replaced ,0 =battery needs not to be replaced |
||
bbuRetentiontime | 1.3.6.1.4.1.3582.4.1.4.1.6.2.1.28 |
The total no. of hours the battery can support the current capacity reserve. Undefined(0),48 hours+(>48),the exact no of hours(<=48) |
||
bbuState | 1.3.6.1.4.1.3582.4.1.4.1.6.2.1.29 |
This property gives the Information about BBU state. Operational = if BBU is working fine, Non-Operational = if BBU is not working fine |
||
memoryModuleFRU | 1.3.6.1.4.1.3582.4.1.4.1.6.2.1.30 |
tmm FRU |
||
bbuFirmwareVersion | 1.3.6.1.4.1.3582.4.1.4.1.6.2.1.31 |
Battery Firmware Version |
||
autoLearnMode | 1.3.6.1.4.1.3582.4.1.4.1.6.2.1.32 |
Automatic Learn Mode |
||
chargingStatus | 1.3.6.1.4.1.3582.4.1.4.1.6.2.1.33 |
Charging Status |
||
capacitance | 1.3.6.1.4.1.3582.4.1.4.1.6.2.1.34 |
Capacitance |
||
commonDeviceInfoTable | 1.3.6.1.4.1.3582.4.1.4.1.7 |
A List of general Physical Disk info |
||
1.3.6.1.4.1.3582.4.1.4.1.7.1 |
An Entry in the CommonDeviceInfo table. |
|||
adapterID-CDIT | 1.3.6.1.4.1.3582.4.1.4.1.7.1.1 |
Unique adapter ID |
||
forceOnline | 1.3.6.1.4.1.3582.4.1.4.1.7.1.2 |
Physical drive force Online operation support. Values: notSupported(0), supported(1) |
||
forceOffline | 1.3.6.1.4.1.3582.4.1.4.1.7.1.3 |
Physical drive force Offline operation support. Values: notSupported(0), supported(1) |
||
forceRebuild | 1.3.6.1.4.1.3582.4.1.4.1.7.1.4 |
Physical drive force Rebuild operation support. Values: notSupported(0), supported(1) |
||
supportsSAS | 1.3.6.1.4.1.3582.4.1.4.1.7.1.5 |
SAS physical drive support. Values: notSupported(0), supported(1) |
||
supportsSATA | 1.3.6.1.4.1.3582.4.1.4.1.7.1.6 |
SATA physical drive support. Values: notSupported(0), supported(1) |
||
allowMixInEnclosure | 1.3.6.1.4.1.3582.4.1.4.1.7.1.7 |
Mix InEnclosure support. Values: notSupported(0), supported(1) |
||
allowMixInVD | 1.3.6.1.4.1.3582.4.1.4.1.7.1.8 |
MixInVIRTUALDRIVE support. Values: notSupported(0), supported(1) |
||
allowSataInCluster | 1.3.6.1.4.1.3582.4.1.4.1.7.1.9 |
SataInCluster support. Values: notSupported(0), supported(1) |
||
setPowerStateForCfg | 1.3.6.1.4.1.3582.4.1.4.1.7.1.10 |
FW requires application to set power state before configuration changes. Required(1), Not Required(0) |
||
commonVirtualDeviceInfoTable | 1.3.6.1.4.1.3582.4.1.4.1.8 |
A List of general Virtual Drive info |
||
1.3.6.1.4.1.3582.4.1.4.1.8.1 |
An Entry in the CommonVirtualDeviceInfo table. |
|||
adapterID-CVDIT | 1.3.6.1.4.1.3582.4.1.4.1.8.1.1 |
Unique adapter ID |
||
supportedReadPolicy | 1.3.6.1.4.1.3582.4.1.4.1.8.1.2 |
Read policy support. Values: false(0),true(1) |
||
supportedWritePolicy | 1.3.6.1.4.1.3582.4.1.4.1.8.1.3 |
Write policy support. Values: false(0),true(1) |
||
supportedIOPolicy | 1.3.6.1.4.1.3582.4.1.4.1.8.1.4 |
IO policy support. Values: false(0),true(1) |
||
supportedAccessPolicy | 1.3.6.1.4.1.3582.4.1.4.1.8.1.5 |
Access policy support. Values: false(0),true(1) |
||
supportedMinSize | 1.3.6.1.4.1.3582.4.1.4.1.8.1.6 |
Minimum stripe size supported. 0(512B),1(1K),2(2K),3(4K),4(8K),5(16K),6(32),7(64K),8(128K) ... 11(1MB) etc |
||
supportedMaxSize | 1.3.6.1.4.1.3582.4.1.4.1.8.1.7 |
Maximum stripe size supported. 0(512B),1(1K),2(2K),3(4K),4(8K),5(16K),6(32),7(64K),8(128K) ... 11(1MB) etc |
||
ldbbm | 1.3.6.1.4.1.3582.4.1.4.1.8.1.8 |
1=LD bad block management is enabled, 0=LD bad block management is not enabled |
||
adapterStatusSupportInfoTable | 1.3.6.1.4.1.3582.4.1.4.1.9 |
A List of adapter Entries containing Information/Properties about the adapters on the Controller. |
||
1.3.6.1.4.1.3582.4.1.4.1.9.1 |
An Entry in the adapter table. |
|||
adapterID-ASSIT | 1.3.6.1.4.1.3582.4.1.4.1.9.1.1 |
AdapterID for this Adapter.(Unique) |
||
lockKeyAssigned | 1.3.6.1.4.1.3582.4.1.4.1.9.1.2 |
Lock key Assigned support for this Adapter. Values: false(0),true(1) |
||
lockKeyFailed | 1.3.6.1.4.1.3582.4.1.4.1.9.1.3 |
lock Key Failed support for this Adapter. Values: false(0),true(1) |
||
lockKeyNotBackedup | 1.3.6.1.4.1.3582.4.1.4.1.9.1.4 |
lock Key Not Backedup support for this Adapter. Values: false(0),true(1) |
||
biosNotDetected | 1.3.6.1.4.1.3582.4.1.4.1.9.1.5 |
bios Not Detected support for this Adapter. Values: false(0),true(1) |
||
cacheIsPinned | 1.3.6.1.4.1.3582.4.1.4.1.9.1.6 |
1=controller cache is pinned for missing or offline LDs |
||
adapterLdOperationSupportInfoTable | 1.3.6.1.4.1.3582.4.1.4.1.10 |
A List of adapter Entries containing Information/Properties about the adapters on the Controller. |
||
1.3.6.1.4.1.3582.4.1.4.1.10.1 |
An Entry in the adapter table. |
|||
adapterID-ALSIT | 1.3.6.1.4.1.3582.4.1.4.1.10.1.1 |
AdapterID for this Adapter.(Unique) |
||
allowCtrlEncryption | 1.3.6.1.4.1.3582.4.1.4.1.10.1.2 |
if it is set (1) supports controller encryption |
||
device | 1.3.6.1.4.1.3582.4.1.4.2 | |||
physicalDriveInfo | 1.3.6.1.4.1.3582.4.1.4.2.1 | |||
pdNumber | 1.3.6.1.4.1.3582.4.1.4.2.1.1 |
The present number of rows in the physical drive table. |
||
physicalDriveTable | 1.3.6.1.4.1.3582.4.1.4.2.1.2 |
A List of physical drive Entries containing Information/Properties about the drives |
||
1.3.6.1.4.1.3582.4.1.4.2.1.2.1 |
An Entry in the Device Table. |
|||
pdIndex | 1.3.6.1.4.1.3582.4.1.4.2.1.2.1.1 |
The unique ID |
||
physDevID | 1.3.6.1.4.1.3582.4.1.4.2.1.2.1.2 |
The Device ID |
||
oemSupported | 1.3.6.1.4.1.3582.4.1.4.2.1.2.1.3 |
Is the drive supported by the OEM (OEM-specific checks). Values: notSupported(1), supported(0) |
||
scsiDevType | 1.3.6.1.4.1.3582.4.1.4.2.1.2.1.4 |
Type of this Device. Values: disk(0),tape(1),printer(2),processor(3),cdrom(5),scanner(6),optical(7),enclosure(13),dvd(10),unknown(31) |
||
connectedAdapterPort | 1.3.6.1.4.1.3582.4.1.4.2.1.2.1.5 |
Adapter port(s) to which the device is connected. |
||
deviceSpeed | 1.3.6.1.4.1.3582.4.1.4.2.1.2.1.6 |
Maximum supported speed. Values: speed-unknown(0),speed-1p5G(1),speed-3G(2),speed-6G(3) |
||
mediaErrCount | 1.3.6.1.4.1.3582.4.1.4.2.1.2.1.7 |
Error count of the device |
||
otherErrCount | 1.3.6.1.4.1.3582.4.1.4.2.1.2.1.8 |
Other error count of the device |
||
predFailCount | 1.3.6.1.4.1.3582.4.1.4.2.1.2.1.9 |
Predictive fail count of the device |
||
pdState | 1.3.6.1.4.1.3582.4.1.4.2.1.2.1.10 |
Firmwares interpretation of drive state. Values: unconfigured-good(0),unconfigured-bad(1),hot-spare(2),offline(16),failed(17),rebuild(20),online(24),copyback(32),system(64),UNCONFIGURED-SHIELDED(128),HOTSPARE-SHIELDED(130),CONFIGURED-SHIELDED(144) |
||
disabledForRemoval | 1.3.6.1.4.1.3582.4.1.4.2.1.2.1.11 |
If true, drive is ready for removal. Values: false(0),true(1) |
||
linkSpeed | 1.3.6.1.4.1.3582.4.1.4.2.1.2.1.12 |
Negotiated link speed. Values: speed-unknown(0),speed-1p5G(1),speed-3G(2),speed-6G(3) |
||
pdSupportFlags | 1.3.6.1.4.1.3582.4.1.4.2.1.2.1.13 |
1st Byte:forcedPDGUID(0/1),2nd Byte:inVD(0/1),3rd Byte:isGlobalSpare(0/1),4th Byte:isSpare(0/1),5th Byte:isForeign(0/1),6th Byte:intf(0-Unknown, 1-parallel SCSI, 2-SAS, 3-SATA, 4-FC).A comma delimited list will appear. |
||
sasAddr | 1.3.6.1.4.1.3582.4.1.4.2.1.2.1.14 |
Device SAS addresses. Comma separeted for multiple address |
||
rawSize | 1.3.6.1.4.1.3582.4.1.4.2.1.2.1.15 |
Size(MB) before COD and coercion |
||
nonCoercedSize | 1.3.6.1.4.1.3582.4.1.4.2.1.2.1.16 |
Size(MB) after COD is reserved but before coercion |
||
coercedSize | 1.3.6.1.4.1.3582.4.1.4.2.1.2.1.17 |
Size(MB) after COD is reserved and after coercion |
||
enclDeviceId | 1.3.6.1.4.1.3582.4.1.4.2.1.2.1.18 |
Enclosures device Id (in decimal); if device is not within enclosure value is -1 |
||
enclIndex | 1.3.6.1.4.1.3582.4.1.4.2.1.2.1.19 |
Firmware internal enclosure index |
||
slotNumber | 1.3.6.1.4.1.3582.4.1.4.2.1.2.1.20 |
Slot number of this drive, if the Physical Disk is part of an enclosure then -1 |
||
operationProgress | 1.3.6.1.4.1.3582.4.1.4.2.1.2.1.21 |
Operation progress in %. e.g. Rebuild progress is 10% |
||
adpID-PDT | 1.3.6.1.4.1.3582.4.1.4.2.1.2.1.22 |
Controller id where this Physical Drive is attached |
||
operationSupport | 1.3.6.1.4.1.3582.4.1.4.2.1.2.1.23 |
MakeOnline,MakeOffline,MakeFailed,MakeBad,MakeUncofigured, MakeSpare,RemoveSpare,replaceMissing,markMissing,startRebuild, stopRebuild,locate,pdclear,foreignImportNotAllowed,ForeignImportAllowed, startCopyBack,stopCopyBack,fwDownloadNotAllowed,fwDownloadAllowed,makeSystem |
||
pdVendorID | 1.3.6.1.4.1.3582.4.1.4.2.1.2.1.24 |
Vendor ID |
||
pdProductID | 1.3.6.1.4.1.3582.4.1.4.2.1.2.1.25 |
Product ID |
||
pdFwversion | 1.3.6.1.4.1.3582.4.1.4.2.1.2.1.26 |
PD firmware version |
||
diskType | 1.3.6.1.4.1.3582.4.1.4.2.1.2.1.27 |
Type of the disk : 0-Unknown, 1-parallel SCSI, 2-SAS, 3-SATA, 4-FC |
||
partnerDevId | 1.3.6.1.4.1.3582.4.1.4.2.1.2.1.28 |
If drive is in an enclosure with dual paths,This is Partner Device ID. In all other cases INVALID(-1) |
||
mediatype | 1.3.6.1.4.1.3582.4.1.4.2.1.2.1.29 |
Media Type HDD(0),SSD(1),Solid state flash module(2) |
||
powerState | 1.3.6.1.4.1.3582.4.1.4.2.1.2.1.30 |
Power condition of the device. Values are device is active(0),device is stopped(1),device is transitioning between power states(255) |
||
secured | 1.3.6.1.4.1.3582.4.1.4.2.1.2.1.31 |
1=drive is secured, 0=not secured |
||
locked | 1.3.6.1.4.1.3582.4.1.4.2.1.2.1.32 |
1=drive is locked, 0=unlocked |
||
foreign | 1.3.6.1.4.1.3582.4.1.4.2.1.2.1.33 |
1=drive is secured by a foreign lock key, 0=drive is not secured by a foreign lock key |
||
oemCertified | 1.3.6.1.4.1.3582.4.1.4.2.1.2.1.34 |
Is the drive certified by the OEM (OEM-specific checks). Values: notCertified(1), Certified(0) |
||
foreignImportNotAllowed | 1.3.6.1.4.1.3582.4.1.4.2.1.2.1.35 |
1=Drive is not allowed foreignImport operation, 0=Drive is allowed foreignImport operation |
||
pdTemperature | 1.3.6.1.4.1.3582.4.1.4.2.1.2.1.36 |
Physical Drive temperature in Celsius |
||
pdSerialNumber | 1.3.6.1.4.1.3582.4.1.4.2.1.2.1.37 |
Physical Drives serial number |
||
piEligible | 1.3.6.1.4.1.3582.4.1.4.2.1.2.1.38 |
Protection Information eligibility.1=drive can be used for PD Enabled LD , 0=drive cant be used for PD Enabled LD |
||
piType | 1.3.6.1.4.1.3582.4.1.4.2.1.2.1.39 |
SAS Protection Information Type .No SAS protection type used(0) ,SAS PI Type 1(1) ,SAS PI Type 2(2) ,SAS PI Type 3(3) ,Reserved SAS PI Type 4(4) ,Reserved SAS PI Type 5(5) ,Reserved SAS PI Type 6(6) ,Reserved SAS PI Type 7(7). |
||
piFormatted | 1.3.6.1.4.1.3582.4.1.4.2.1.2.1.40 |
formatted for PI information. 1=drive is formatted for PI information, 0=no PI data. |
||
userDataBlockSize | 1.3.6.1.4.1.3582.4.1.4.2.1.2.1.41 |
Number of bytes of user data in LBA |
||
commissionedSpare | 1.3.6.1.4.1.3582.4.1.4.2.1.2.1.42 |
Yes = this PD is a commissioned spare, No = this PD is not a commissioned spare. |
||
emergencySpare | 1.3.6.1.4.1.3582.4.1.4.2.1.2.1.43 |
Eligible = this PD is a emergency spare, Ineligible = this PD is not a emergency spare. |
||
shieldCounter | 1.3.6.1.4.1.3582.4.1.4.2.1.2.1.44 |
How many times the shield diagnostics was run before it was marked failed |
||
shieldDiagCompletionTime | 1.3.6.1.4.1.3582.4.1.4.2.1.2.1.45 |
Last successful Diagnostics completion time. 0 is N/A |
||
ineligibleForSSCD | 1.3.6.1.4.1.3582.4.1.4.2.1.2.1.46 |
Whether PD cannot be used for an SSCD. PD can not be used for an SSCD(1), PD can be used for an SSCD(0) |
||
ineligibleForLd | 1.3.6.1.4.1.3582.4.1.4.2.1.2.1.47 |
Whether PD cannot be used for a regular LD. PD can not be used for a regular LD(1), PD can be used for a regular LD(0) |
||
serviceable | 1.3.6.1.4.1.3582.4.1.4.2.1.2.1.48 |
Whether PD is removeable for service. PD is removeable for service(1), PD is not removeable for service(0) |
||
virtualDevice | 1.3.6.1.4.1.3582.4.1.4.3 | |||
vdInfo | 1.3.6.1.4.1.3582.4.1.4.3.1 | |||
vdNumbers | 1.3.6.1.4.1.3582.4.1.4.3.1.1 |
The present number of rows in the virtualDrive table. |
||
virtualDriveTable | 1.3.6.1.4.1.3582.4.1.4.3.1.2 |
A List of Virtual Drives Entries containing Information/Properties about the virtualDrive. |
||
1.3.6.1.4.1.3582.4.1.4.3.1.2.1 |
An Entry in the virtualDrive Table. |
|||
virtualDevID | 1.3.6.1.4.1.3582.4.1.4.3.1.2.1.1 |
The unique Virtual Drives ID |
||
size | 1.3.6.1.4.1.3582.4.1.4.3.1.2.1.2 |
Total size in MB of the drive |
||
clusterOwnerDeviceId | 1.3.6.1.4.1.3582.4.1.4.3.1.2.1.3 |
VD owners device Id |
||
targetId | 1.3.6.1.4.1.3582.4.1.4.3.1.2.1.4 |
Virtual Drive target id (i.e. 0 to 63) |
||
state | 1.3.6.1.4.1.3582.4.1.4.3.1.2.1.5 |
The Device state: Values: offline(0),partially-degraded(1),degraded(2),optimal(3) |
||
name | 1.3.6.1.4.1.3582.4.1.4.3.1.2.1.6 |
Virtual Drive name |
||
defaultCachePolicy | 1.3.6.1.4.1.3582.4.1.4.3.1.2.1.7 |
Default cache policy settings. Values: WriteBack, WriteThrough, ReadAdaptive, ReadAhead, ReadAheadNone, Cached, Direct, Write Cache OK if Bad BBU, No Write Cache if Bad BBU. |
||
accessPolicy | 1.3.6.1.4.1.3582.4.1.4.3.1.2.1.8 |
Access policy settings. Values: access-rw(0), access-read-only(2), access-blocked(3) |
||
diskCachePolicy | 1.3.6.1.4.1.3582.4.1.4.3.1.2.1.9 |
Physical disk cache policy. Values: unchanged(0),enable(1),disable(2) |
||
bgiState | 1.3.6.1.4.1.3582.4.1.4.3.1.2.1.10 |
Disable/Enable Back Groung Initialization on this Virtual Drive. Values: disable(1),enable(0) |
||
prl | 1.3.6.1.4.1.3582.4.1.4.3.1.2.1.11 |
Primay raid level. Values: 0(RAID-0), 1(RAID-1), 3(RAID-3), 4(RAID-4), 5(RAID-5), 6(RAID-6),15(Single Disk or JBOD), 17(RAID-1E), 21(RAID-5E), 31(Concatenation),37(RAID-5EEE) |
||
rLQ | 1.3.6.1.4.1.3582.4.1.4.3.1.2.1.12 |
Raid level qualifier |
||
sRL | 1.3.6.1.4.1.3582.4.1.4.3.1.2.1.13 |
Secondary raid level. Values: 0(Stripped), 1(Mirrored), 2(Concatenated), 3(Spanned) |
||
stripeSize | 1.3.6.1.4.1.3582.4.1.4.3.1.2.1.14 |
Stripe Size. 0(512B),1(1K),2(2K),3(4K),4(8K),5(16K),6(32),7(64K),8(128K) ... 11(1MB) etc |
||
numDrives | 1.3.6.1.4.1.3582.4.1.4.3.1.2.1.15 |
Number of drivers per span |
||
spanDepth | 1.3.6.1.4.1.3582.4.1.4.3.1.2.1.16 |
Number of spans. If only one array then it is considered as 1 span |
||
initState | 1.3.6.1.4.1.3582.4.1.4.3.1.2.1.17 |
0=no init, 1=quick init, 2=full init |
||
vdOperationProgress | 1.3.6.1.4.1.3582.4.1.4.3.1.2.1.18 |
Progress % for an operation / No operation in progress |
||
currentCachePolicy | 1.3.6.1.4.1.3582.4.1.4.3.1.2.1.19 |
Cache policy settings. Values:WriteBack, WriteThrough, ReadAdaptive, ReadAhead, ReadAheadNone, Cached, Direct, Write Cache OK if Bad BBU, No Write Cache if Bad BBU. |
||
adapterID-VDT | 1.3.6.1.4.1.3582.4.1.4.3.1.2.1.20 |
Adapter ID |
||
encryptionType | 1.3.6.1.4.1.3582.4.1.4.3.1.2.1.21 |
logical drive encryption type. Values No Encryption(0), FDE drive encryption(1), Controller-based encryption(2) |
||
vdOperationSupport | 1.3.6.1.4.1.3582.4.1.4.3.1.2.1.22 |
startFGI,stopFGI,startCC,stopCC,startRecon,deleteLD |
||
badBlocksExist | 1.3.6.1.4.1.3582.4.1.4.3.1.2.1.23 |
0 = LD bad block table is empty, 1 = LD bad block table is not empty |
||
defaultPSPolicy | 1.3.6.1.4.1.3582.4.1.4.3.1.2.1.24 |
Power Savings policy set for this LD.Values:controller default power saving policy=0, AUTO=1, MAX=2, MAX with no cache=6, NONE=255 |
||
currentPSPolicy | 1.3.6.1.4.1.3582.4.1.4.3.1.2.1.25 |
Power Savings policy set for this LD.Values:controller default power saving policy=0, AUTO=1, MAX=2, MAX with no cache=6, NONE=255 |
||
breakMirror | 1.3.6.1.4.1.3582.4.1.4.3.1.2.1.26 |
Break Mirror Policy set for this LD.Values:1=break mirror is allowed, 0=break mirror not is allowed |
||
joinMirror | 1.3.6.1.4.1.3582.4.1.4.3.1.2.1.27 |
Join Mirror policy set for this LD.Values:1=join mirror is allowed, 0=join mirror not is allowed |
||
mirrorPdInfo | 1.3.6.1.4.1.3582.4.1.4.3.1.2.1.28 |
Mirror Info Property give the Information about mirror of PD and PD state respectively. |
||
vdPiType | 1.3.6.1.4.1.3582.4.1.4.3.1.2.1.29 |
Information about logical drive protection type . No SAS protection type used(0) ,SAS PI Type 1(1) ,SAS PI Type 2(2) ,SAS PI Type 3(3) ,Reserved SAS PI Type 4(4) ,Reserved SAS PI Type 5(5) ,Reserved SAS PI Type 6(6) ,Reserved SAS PI Type 7(7) ,SAS PI Type 8(8). |
||
mirrorDataSize | 1.3.6.1.4.1.3582.4.1.4.3.1.2.1.30 |
Total Space used for mirrorData or Parity information |
||
cacheCadeType | 1.3.6.1.4.1.3582.4.1.4.3.1.2.1.31 |
0= Non-CacheCade VD, 1= CacheCade Type is Read & Write, 2= CacheCade Type is Read only, 3= R1-EC |
||
currentWritePolicy | 1.3.6.1.4.1.3582.4.1.4.3.1.2.1.32 |
Current write policy settings. Values: WriteBack, WriteThrough, AlwaysWriteBack |
||
defaultWritePolicy | 1.3.6.1.4.1.3582.4.1.4.3.1.2.1.33 |
Default write policy settings. Values: WriteBack, WriteThrough, AlwaysWriteBack |
||
associatedVD | 1.3.6.1.4.1.3582.4.1.4.3.1.2.1.34 |
This property gives the Information about VD is Cached or VD is not cached. |
||
hostAccessPolicy | 1.3.6.1.4.1.3582.4.1.4.3.1.2.1.35 |
This property gives the Host Access Policy |
||
guid | 1.3.6.1.4.1.3582.4.1.4.3.1.2.1.36 |
This property gives the LD GUID. |
||
fastPathWBEnabled | 1.3.6.1.4.1.3582.4.1.4.3.1.2.1.37 |
0= FastPathWB disabled, not a Raptor like LD, 1= FastPathWB enabled, Raptor like LD |
||
peerHasNoAccess | 1.3.6.1.4.1.3582.4.1.4.3.1.2.1.38 |
Peer cant access this shared ld, not applicable for exclusive LD |
||
vdSpanInfoTable | 1.3.6.1.4.1.3582.4.1.4.3.1.3 |
A List of span Entries containing Information/Properties vd span. |
||
1.3.6.1.4.1.3582.4.1.4.3.1.3.1 |
An Entry in the vdSpan Table. |
|||
spanID | 1.3.6.1.4.1.3582.4.1.4.3.1.3.1.1 |
The unique Span ID |
||
vdID-VSIT | 1.3.6.1.4.1.3582.4.1.4.3.1.3.1.2 |
The Virtual Device ID |
||
startBlock | 1.3.6.1.4.1.3582.4.1.4.3.1.3.1.3 |
Span physical disk starting block |
||
numBlocks | 1.3.6.1.4.1.3582.4.1.4.3.1.3.1.4 |
Span physical disk block count |
||
vdSpanArrayRef | 1.3.6.1.4.1.3582.4.1.4.3.1.3.1.5 |
Array reference (index) |
||
adapterID-VSIT | 1.3.6.1.4.1.3582.4.1.4.3.1.3.1.6 |
Adapter ID |
||
arrayInfo | 1.3.6.1.4.1.3582.4.1.4.3.4 | |||
arrayNumber | 1.3.6.1.4.1.3582.4.1.4.3.4.1 |
The present number of rows in the array table. |
||
arrayTable | 1.3.6.1.4.1.3582.4.1.4.3.4.2 |
A List of array Entries containing Information/Properties about the arrays. |
||
1.3.6.1.4.1.3582.4.1.4.3.4.2.1 |
An Entry in the array Table. |
|||
arrayID | 1.3.6.1.4.1.3582.4.1.4.3.4.2.1.1 |
The unique array ID |
||
arraySize | 1.3.6.1.4.1.3582.4.1.4.3.4.2.1.2 |
Size in MB |
||
arrayNumDrives | 1.3.6.1.4.1.3582.4.1.4.3.4.2.1.3 |
Number of drives for this array |
||
arrayRef | 1.3.6.1.4.1.3582.4.1.4.3.4.2.1.4 |
Tag for the array |
||
pdList | 1.3.6.1.4.1.3582.4.1.4.3.4.2.1.5 |
Space separated Physical Drive identification. e.g. {devID devID devID} etc |
||
adapterID-AT | 1.3.6.1.4.1.3582.4.1.4.3.4.2.1.6 |
Adapter ID. |
||
spareInfo | 1.3.6.1.4.1.3582.4.1.4.3.5 | |||
spareDevNumber | 1.3.6.1.4.1.3582.4.1.4.3.5.1 |
The present number of rows in the sparepool table. |
||
spareTable | 1.3.6.1.4.1.3582.4.1.4.3.5.2 |
A List of sparepool Entries containing Information/Properties about the spare drive |
||
1.3.6.1.4.1.3582.4.1.4.3.5.2.1 |
An Entry in the sparepool Table. |
|||
spareID | 1.3.6.1.4.1.3582.4.1.4.3.5.2.1.1 |
The unique Device ID |
||
deviceIdentification | 1.3.6.1.4.1.3582.4.1.4.3.5.2.1.2 |
The unique Device ID |
||
spareType | 1.3.6.1.4.1.3582.4.1.4.3.5.2.1.3 |
Spare type. isDedicated(0/1)isRevertible(0/1)isEnclAffinity(0/1). 1 implies particular feature is enable and 0 represent feature is disable. |
||
arrayCount | 1.3.6.1.4.1.3582.4.1.4.3.5.2.1.4 |
The number of arrays to which the Physical Drive can be dedicated |
||
arrayIDs | 1.3.6.1.4.1.3582.4.1.4.3.5.2.1.5 |
Comma separated array ids. e.g. 2,4,5 etc |
||
adapterID-ST | 1.3.6.1.4.1.3582.4.1.4.3.5.2.1.6 |
Adapter ID. |
||
enclosureInfo | 1.3.6.1.4.1.3582.4.1.5 | |||
enclosureNumber | 1.3.6.1.4.1.3582.4.1.5.1 |
The present number of rows in the enclosure table. |
||
enclosureTable | 1.3.6.1.4.1.3582.4.1.5.2 |
A List of Enclosure Entries containing Information/Properties about the enclosures in the system. |
||
1.3.6.1.4.1.3582.4.1.5.2.1 |
An Entry in the enclosure table. |
|||
enclosureID | 1.3.6.1.4.1.3582.4.1.5.2.1.1 |
EnclosureID for this enclosure.(Unique) |
||
deviceId | 1.3.6.1.4.1.3582.4.1.5.2.1.2 |
Enclosure device Id. |
||
enclosureIndex | 1.3.6.1.4.1.3582.4.1.5.2.1.3 |
Firmware internal enclosure index |
||
slotCount | 1.3.6.1.4.1.3582.4.1.5.2.1.4 |
Number of slots |
||
psCount | 1.3.6.1.4.1.3582.4.1.5.2.1.5 |
Number of power supplies |
||
fanCount | 1.3.6.1.4.1.3582.4.1.5.2.1.6 |
Number of fans |
||
tempSensorCount | 1.3.6.1.4.1.3582.4.1.5.2.1.7 |
Number of temperature sensors |
||
alarmCount | 1.3.6.1.4.1.3582.4.1.5.2.1.8 |
Number of alarms |
||
simCount | 1.3.6.1.4.1.3582.4.1.5.2.1.9 |
Number of SIM modules |
||
isFault | 1.3.6.1.4.1.3582.4.1.5.2.1.10 |
Enclosure has entered a FAULT state or not. Values: false(0),true(1) |
||
pdCount | 1.3.6.1.4.1.3582.4.1.5.2.1.11 |
Number of physical drives present |
||
pdIds | 1.3.6.1.4.1.3582.4.1.5.2.1.12 |
Physical drive deviceIds space separated. |
||
adapterID-ET | 1.3.6.1.4.1.3582.4.1.5.2.1.13 |
Adapter ID. |
||
pdCountSpinup60 | 1.3.6.1.4.1.3582.4.1.5.2.1.14 |
Number of drives that can spun up in 60 sec. |
||
enclosureType | 1.3.6.1.4.1.3582.4.1.5.2.1.15 |
Information about type of enclosure : 0= UNKNOWN ,1= SAFTE ,2=SES ,3= SGPIO. |
||
enclFirmwareVersion | 1.3.6.1.4.1.3582.4.1.5.2.1.16 |
Information about enclosure FW Version |
||
enclSerialNumber | 1.3.6.1.4.1.3582.4.1.5.2.1.17 |
Enclosure Serial Number |
||
vendorID | 1.3.6.1.4.1.3582.4.1.5.2.1.18 |
Enclosure Vendor ID |
||
productID | 1.3.6.1.4.1.3582.4.1.5.2.1.19 |
Enclosure Product ID |
||
eSMSerialNumber | 1.3.6.1.4.1.3582.4.1.5.2.1.20 |
IBM Enclosure ESM Serial Number |
||
eSMFRU | 1.3.6.1.4.1.3582.4.1.5.2.1.21 |
Information about IBM Enclosure ESM FRU |
||
enclosureZoningMode | 1.3.6.1.4.1.3582.4.1.5.2.1.22 |
Enclosure IBM Zoning Mode |
||
eSMFRUPartInfo | 1.3.6.1.4.1.3582.4.1.5.2.1.23 |
Information about IBM Enclosure ESM FRU Part |
||
enclosureFanTable | 1.3.6.1.4.1.3582.4.1.5.3 |
A List of fan Entries containing Information/Properties about the enclosureFan. |
||
1.3.6.1.4.1.3582.4.1.5.3.1 |
An Entry in the enclosureFan table. |
|||
fanID | 1.3.6.1.4.1.3582.4.1.5.3.1.1 |
ID for this EnclosureFan.(Unique) |
||
enclosureId | 1.3.6.1.4.1.3582.4.1.5.3.1.2 |
Enclosure ID where the fan is attached |
||
fanStatus | 1.3.6.1.4.1.3582.4.1.5.3.1.3 |
status of the fan |
||
enclosureSlotTable | 1.3.6.1.4.1.3582.4.1.5.4 |
A List of slot Entries containing Information/Properties about the enclosure slots. |
||
1.3.6.1.4.1.3582.4.1.5.4.1 |
An Entry in the enclosureSlot table. |
|||
slotID | 1.3.6.1.4.1.3582.4.1.5.4.1.1 |
ID for this slot.(Unique) |
||
enclosureId-EST | 1.3.6.1.4.1.3582.4.1.5.4.1.2 |
enclosure ID |
||
slotStatus | 1.3.6.1.4.1.3582.4.1.5.4.1.3 |
status of the device |
||
enclosurePowerSupplyTable | 1.3.6.1.4.1.3582.4.1.5.5 |
A List of powerSupply Entries containing Information/Properties about the enclosure powerSupply |
||
1.3.6.1.4.1.3582.4.1.5.5.1 |
An Entry in the powerSupply table. |
|||
powerSupplyID | 1.3.6.1.4.1.3582.4.1.5.5.1.1 |
ID for this powerSupply.(Unique) |
||
enclosureId-EPST | 1.3.6.1.4.1.3582.4.1.5.5.1.2 |
Enclosure id for the powerSupply |
||
powerSupplyStatus | 1.3.6.1.4.1.3582.4.1.5.5.1.3 |
Status of the power Supply |
||
enclosureTempSensorTable | 1.3.6.1.4.1.3582.4.1.5.6 |
A List of TempSensor Entries containing Information/Properties about the enclosure TempSensor |
||
1.3.6.1.4.1.3582.4.1.5.6.1 |
An Entry in the adapter table. |
|||
tempSensorID | 1.3.6.1.4.1.3582.4.1.5.6.1.1 |
ID for this TempSensor.(Unique) |
||
enclosureId-ETST | 1.3.6.1.4.1.3582.4.1.5.6.1.2 |
Enclosure id for this TempSensor |
||
tempSensorStatus | 1.3.6.1.4.1.3582.4.1.5.6.1.3 |
Status of the Temparature Sensor |
||
enclosureTemperature | 1.3.6.1.4.1.3582.4.1.5.6.1.4 |
Current temperature in degree Centigrade |
||
enclosureAlarmTable | 1.3.6.1.4.1.3582.4.1.5.7 |
A List of Alarm Entries containing Information/Properties about enclosure Alarms |
||
1.3.6.1.4.1.3582.4.1.5.7.1 |
An Entry in the enclosureAlarm table. |
|||
alarmID | 1.3.6.1.4.1.3582.4.1.5.7.1.1 |
ID for this Alarm.(Unique) |
||
enclosureId-EAT | 1.3.6.1.4.1.3582.4.1.5.7.1.2 |
Enclosure id where the Alarm is attached |
||
alarmStatus | 1.3.6.1.4.1.3582.4.1.5.7.1.3 |
Status of the alarm |
||
enclosureSIMTable | 1.3.6.1.4.1.3582.4.1.5.8 |
A List of SIM Entries containing Information/Properties about enclosure SIMs |
||
1.3.6.1.4.1.3582.4.1.5.8.1 |
An Entry in the enclosureSIM table. |
|||
simID | 1.3.6.1.4.1.3582.4.1.5.8.1.1 |
ID for this SIM.(Unique) |
||
enclosureId-ESIT | 1.3.6.1.4.1.3582.4.1.5.8.1.2 |
Inclosure ID where the SIM is attached |
||
simStatus | 1.3.6.1.4.1.3582.4.1.5.8.1.3 |
Status of the SIM |
||
adapterTraps | 1.3.6.1.4.1.3582.4.1.6 | |||
adpAlarmStateEnabled | 1.3.6.1.4.1.3582.4.1.6.0.8001 |
Alarm has been enabled by user for Adapter $1 |
||
adpBGIRateChanged | 1.3.6.1.4.1.3582.4.1.6.0.8002 |
Background initialization rate changed to $1 for Adapter $2 |
||
adpCacheDiscarded | 1.3.6.1.4.1.3582.4.1.6.0.8003 |
Controller $1 cache discarded due to memory/battery problems |
||
adpCacheRebootCantRecover | 1.3.6.1.4.1.3582.4.1.6.0.8004 |
Unable to recover cache data due to configuration mismatch for Adapter $1 |
||
adpCacheRebootRecover | 1.3.6.1.4.1.3582.4.1.6.0.8005 |
Cache data recovered successfully for Adapter $1 |
||
adpCacheVersionMismatch | 1.3.6.1.4.1.3582.4.1.6.0.8006 |
Controller cache discarded due to firmware version incompatibility for Adapter $1 |
||
adpCCRateChanged | 1.3.6.1.4.1.3582.4.1.6.0.8007 |
Consistency Check rate changed to $1 for Adapter $2 |
||
adpFlashBadImage | 1.3.6.1.4.1.3582.4.1.6.0.8008 |
Flash downloaded image corrupted for Adapter $1 |
||
adpFlashEraseError | 1.3.6.1.4.1.3582.4.1.6.0.8009 |
Flash erase error for Adapter $1 |
||
adpFlashEraseTimeout | 1.3.6.1.4.1.3582.4.1.6.0.8010 |
Flash timeout during erase for Adapter $1 |
||
adpFlashGeneralError | 1.3.6.1.4.1.3582.4.1.6.0.8011 |
Flash error for Adapter $1 |
||
adpFlashImage | 1.3.6.1.4.1.3582.4.1.6.0.8012 |
Flashing image: $1 for Adapter $2 |
||
adpFlashOK | 1.3.6.1.4.1.3582.4.1.6.0.8013 |
Flash of new firmware image(s)complete for Adapter $1 |
||
adpFlashProgramError | 1.3.6.1.4.1.3582.4.1.6.0.8014 |
Flash programming error for Adapter $1 |
||
adpFlashProgramTimeout | 1.3.6.1.4.1.3582.4.1.6.0.8015 |
Flash timeout during programming for Adapter $1 |
||
adpLogCleared | 1.3.6.1.4.1.3582.4.1.6.0.8016 |
Event log cleared for Adapter $1 |
||
adpLogWrapped | 1.3.6.1.4.1.3582.4.1.6.0.8017 |
Event log wrapped for Adapter $1 |
||
adpPatrolReadComplete | 1.3.6.1.4.1.3582.4.1.6.0.8018 |
Patrol Read complete for Adapter $1 |
||
adpPatrolReadPaused | 1.3.6.1.4.1.3582.4.1.6.0.8019 |
Patrol Read paused for Adapter $1 |
||
adpPatrolReadResumed | 1.3.6.1.4.1.3582.4.1.6.0.8020 |
Patrol Read resumed for Adapter $1 |
||
adpPatrolReadStarted | 1.3.6.1.4.1.3582.4.1.6.0.8021 |
Patrol Read started for Adapter $1 |
||
adpShutdown | 1.3.6.1.4.1.3582.4.1.6.0.8022 |
Shutdown command received for Adapter $1 |
||
adpHibernate | 1.3.6.1.4.1.3582.4.1.6.0.8023 |
Hibernate command received for Adapter $1 |
||
adpCrash | 1.3.6.1.4.1.3582.4.1.6.0.8024 |
Fatal error received for Adapter $1 |
||
adpRRChanged | 1.3.6.1.4.1.3582.4.1.6.0.8025 |
Rebuild rate changed to $1 for Adapter $2 |
||
adpPRRateChanged | 1.3.6.1.4.1.3582.4.1.6.0.8026 |
Patrol Read rate changed to $1 for Adapter $2 |
||
adpAlarmStateDisabled | 1.3.6.1.4.1.3582.4.1.6.0.8027 |
Alarm has been disabled by user for Adapter $1 |
||
adpConfigCleared | 1.3.6.1.4.1.3582.4.1.6.0.8028 |
Configuration cleared for Adapter $1 |
||
adpReconRateChanged | 1.3.6.1.4.1.3582.4.1.6.0.8029 |
Reconstruction rate changed to $1 for Adapter $2 |
||
adpDefault | 1.3.6.1.4.1.3582.4.1.6.0.8030 |
Factory defaults restored for Adapter $1 |
||
bbuPresent | 1.3.6.1.4.1.3582.4.1.6.0.8031 |
Battery Present for Adapter $1 |
||
bbuNotPresent | 1.3.6.1.4.1.3582.4.1.6.0.8032 |
Battery Not Present for Adapter $1 |
||
bbuNewBattery | 1.3.6.1.4.1.3582.4.1.6.0.8033 |
New Battery Detected for Adapter $1 |
||
bbuReplaced | 1.3.6.1.4.1.3582.4.1.6.0.8034 |
Battery has been replaced for Adapter $1 |
||
bbuTempHigh | 1.3.6.1.4.1.3582.4.1.6.0.8035 |
Battery temperature is high for Adapter $1 |
||
bbuVoltageLow | 1.3.6.1.4.1.3582.4.1.6.0.8036 |
Battery voltage low for Adapter $1 |
||
bbuCharging | 1.3.6.1.4.1.3582.4.1.6.0.8037 |
Battery started charging for Adapter $1 |
||
bbuDisCharging | 1.3.6.1.4.1.3582.4.1.6.0.8038 |
Battery is discharging for Adapter $1 |
||
bbuTempNormal | 1.3.6.1.4.1.3582.4.1.6.0.8039 |
Battery temperature is normal for Adapter $1 |
||
bbuReplace | 1.3.6.1.4.1.3582.4.1.6.0.8040 |
Battery needs replacement, SOH Bad for Adapter $1 |
||
bbuRelearnStarted | 1.3.6.1.4.1.3582.4.1.6.0.8041 |
Battery relearn started for Adapter $1 |
||
bbuRelearnProgress | 1.3.6.1.4.1.3582.4.1.6.0.8042 |
Battery relearn in progress for Adapter $1 |
||
bbuRelearnComplete | 1.3.6.1.4.1.3582.4.1.6.0.8043 |
Battery relearn completed for Adapter $1 |
||
bbuRelearnTimeout | 1.3.6.1.4.1.3582.4.1.6.0.8044 |
Battery relearn timed out for Adapter $1 |
||
bbuRelearnPending | 1.3.6.1.4.1.3582.4.1.6.0.8045 |
Battery relearn pending: Battery is under charge for Adapter $1 |
||
bbuRelearnPostponed | 1.3.6.1.4.1.3582.4.1.6.0.8046 |
Battery relearn postponed for Adapter $1 |
||
bbuRemoved | 1.3.6.1.4.1.3582.4.1.6.0.8047 |
Battery removed for Adapter $1 |
||
bbuCapacityLow | 1.3.6.1.4.1.3582.4.1.6.0.8048 |
Current capacity of the battery is below threshold for Adapter $1 |
||
bbuCapacityAbove | 1.3.6.1.4.1.3582.4.1.6.0.8049 |
Current capacity of the battery is above threshold for Adapter $1 |
||
bbuFRU | 1.3.6.1.4.1.3582.4.1.6.0.8050 |
Bbu FRU for Adapter $1 changed |
||
revisionIdentifier | 1.3.6.1.4.1.3582.4.1.6.0.8051 |
Revision Identifier for Adapter $1 changed |
||
adpLockKeyCreated | 1.3.6.1.4.1.3582.4.1.6.0.8052 |
Drive security key created for Adapter $1 |
||
adpLockKeyBackedup | 1.3.6.1.4.1.3582.4.1.6.0.8053 |
Drive security key backed up for Adapter $1 |
||
adpLockKeyVerifiedEscrow | 1.3.6.1.4.1.3582.4.1.6.0.8054 |
Drive security key from escrow, verified for Adapter $1 |
||
adpLockKeyRekeyed | 1.3.6.1.4.1.3582.4.1.6.0.8055 |
Drive security key changed for Adapter $1 |
||
adpLockKeyRekeyFailed | 1.3.6.1.4.1.3582.4.1.6.0.8056 |
Drive security key, re-key operation failed for Adapter $1 |
||
adpLockKeyInvalid | 1.3.6.1.4.1.3582.4.1.6.0.8057 |
Drive security key is invalid for Adapter $1 |
||
adpLockKeyDestroyed | 1.3.6.1.4.1.3582.4.1.6.0.8058 |
Drive security key destroyed for Adapter $1 |
||
adpEscrowKeyInvalid | 1.3.6.1.4.1.3582.4.1.6.0.8059 |
Drive security key from escrow is invalid for Adapter $1 |
||
adpLockKeyFailed | 1.3.6.1.4.1.3582.4.1.6.0.8060 |
Drive security key failure, cannot access secured configuration for Adapter $1 |
||
bbuChargeDisabled | 1.3.6.1.4.1.3582.4.1.6.0.8061 |
Battery charging was suspended due to high battery temperature on Adapter $1 |
||
bbuMicrocodeUpdated | 1.3.6.1.4.1.3582.4.1.6.0.8062 |
Battery NVCache firmware update was successful on Adapter $1 |
||
bbuMicrocodeUpdateFailed | 1.3.6.1.4.1.3582.4.1.6.0.8063 |
Battery NVCache firmware update failed on Adapter $1 |
||
haNodeJoin | 1.3.6.1.4.1.3582.4.1.6.0.8064 |
Peer controller entered HA Domain at Adapter -$1 |
||
haNodeBreak | 1.3.6.1.4.1.3582.4.1.6.0.8065 |
Peer controller exited HA Domain at Adapter -$1 |
||
haPeerIncompatible | 1.3.6.1.4.1.3582.4.1.6.0.8066 |
Peer controller settings are incompatible |
||
haCtrlpropIncompatible | 1.3.6.1.4.1.3582.4.1.6.0.8067 |
Controller property mismatch detected with Peer controller |
||
haFWVersionMismatch | 1.3.6.1.4.1.3582.4.1.6.0.8068 |
FW version does not match Peer controller |
||
haCacheMirrorOnline | 1.3.6.1.4.1.3582.4.1.6.0.8069 |
Cache mirroring is online |
||
haCacheMirrorOffline | 1.3.6.1.4.1.3582.4.1.6.0.8070 |
Cache mirroring is offline |
||
adpPropChanged | 1.3.6.1.4.1.3582.4.1.6.0.8071 |
Controller properties changed for Adapter $1 |
||
adpResetNowStart | 1.3.6.1.4.1.3582.4.1.6.0.8072 |
Controller reset requested by host for Adapter $1 |
||
adpResetNowDone | 1.3.6.1.4.1.3582.4.1.6.0.8073 |
Controller reset requested by host, completed for Adapter $1 |
||
atAdpNumber | 1.3.6.1.4.1.3582.4.1.6.1001 |
Adapter ID for which Trap is generated. |
||
atAlarmState | 1.3.6.1.4.1.3582.4.1.6.1002 |
Alarm disabled/enabled. Values: disabled(0),enabled(1) |
||
atRate | 1.3.6.1.4.1.3582.4.1.6.1003 |
BGI/Check Consistency/Rebuild/Patrol Read/Reconstruction Rate |
||
atFlashImageName | 1.3.6.1.4.1.3582.4.1.6.1004 |
Flash Image Name |
||
atID | 1.3.6.1.4.1.3582.4.1.6.1005 |
ID |
||
clustCtrlpropReset | 1.3.6.1.4.1.3582.4.1.6.1006 |
Resetting controller property |
||
vdTraps | 1.3.6.1.4.1.3582.4.1.7 | |||
vdtBGIAborted | 1.3.6.1.4.1.3582.4.1.7.0.8101 |
BGI aborted on Adapter -$1 VD Target -$2 Remote VD -$3 |
||
vdtBGICompleted | 1.3.6.1.4.1.3582.4.1.7.0.8102 |
BGI completed on Adapter -$1 VD Target -$2 Remote VD -$3 |
||
vdtBGIDoneWR | 1.3.6.1.4.1.3582.4.1.7.0.8103 |
BGI completed with uncorrectable errors on Adapter -$1 VD Target -$2 Remote VD -$3 |
||
vdtBGIFailed | 1.3.6.1.4.1.3582.4.1.7.0.8104 |
BGI failed on Adapter -$1 VD Target -$2 Remote VD -$3 |
||
vdtBGIStarted | 1.3.6.1.4.1.3582.4.1.7.0.8105 |
BGI started on Adapter -$1 VD Target -$2 Remote VD -$3 |
||
vdtCCStarted | 1.3.6.1.4.1.3582.4.1.7.0.8107 |
CC started on Adapter -$1 VD Target -$2 Remote VD -$3 |
||
vdtCCCompleted | 1.3.6.1.4.1.3582.4.1.7.0.8108 |
CC completed on Adapter -$1 VD Target -$2 Remote VD -$3 |
||
vdtCCFailed | 1.3.6.1.4.1.3582.4.1.7.0.8109 |
CC failed on Adapter -$1 VD Target -$2 Remote VD -$3 |
||
vdtCCAborted | 1.3.6.1.4.1.3582.4.1.7.0.8110 |
CC aborted on Adapter -$1 VD Target -$2 Remote VD -$3 |
||
vdtCCCompCor | 1.3.6.1.4.1.3582.4.1.7.0.8111 |
CC completed with correction on Adapter -$1 VD Target -$2 Remote VD -$3 |
||
vdtInitAborted | 1.3.6.1.4.1.3582.4.1.7.0.8112 |
Initialization aborted on Adapter -$1 VD Target -$2 Remote VD -$3 |
||
vdtInitFailed | 1.3.6.1.4.1.3582.4.1.7.0.8113 |
Initialization failed on Adapter -$1 VD Target -$2 Remote VD -$3 |
||
vdtInitCompleted | 1.3.6.1.4.1.3582.4.1.7.0.8114 |
Initialization completed on Adapter -$1 VD Target -$2 Remote VD -$3 |
||
vdtInitFastStarted | 1.3.6.1.4.1.3582.4.1.7.0.8115 |
Fast Initialization started on Adapter -$1 VD Target -$2 Remote VD -$3 |
||
vdtInitFullStarted | 1.3.6.1.4.1.3582.4.1.7.0.8116 |
Full Initialization started on Adapter-$1 VD Target-$2 Remote VD -$3 |
||
vdtReconStarted | 1.3.6.1.4.1.3582.4.1.7.0.8117 |
Reconstruction started on Adapter-$1 VD Target-$2 Remote VD -$3 |
||
vdtReconCompleted | 1.3.6.1.4.1.3582.4.1.7.0.8118 |
Reconstruction completed on Adapter -$1 VD Target -$2 Remote VD -$3 |
||
vdtReconResumed | 1.3.6.1.4.1.3582.4.1.7.0.8119 |
Reconstruction resumed on Adapter -$1 VD Target -$2 Remote VD -$3 |
||
vdtReconStopped | 1.3.6.1.4.1.3582.4.1.7.0.8120 |
Reconstruction stopped on Adapter-$1 VD Target-$2 Remote VD -$3 |
||
vdtStateChange | 1.3.6.1.4.1.3582.4.1.7.0.8121 |
VD state changed on Adapter -$1 VD Target -$2 from $3 to $4 |
||
vdtCreated | 1.3.6.1.4.1.3582.4.1.7.0.8122 |
A new VD created on Adapter -$1 VD Target -$2 Remote VD -$3 |
||
vdtDeleted | 1.3.6.1.4.1.3582.4.1.7.0.8123 |
A VD deleted on Adapter -$1 VD Target -$2 Remote VD -$3 |
||
vdtSecured | 1.3.6.1.4.1.3582.4.1.7.0.8124 |
VD is now secured. Adapter -$1 VD Targt -$2 Remote VD -$3 |
||
vdtPartiallySecured | 1.3.6.1.4.1.3582.4.1.7.0.8125 |
VD is partially secured. Adapter -$1 VD Targt -$2 Remote VD -$3 |
||
vdtBbmLogCleared | 1.3.6.1.4.1.3582.4.1.7.0.8126 |
VD bad block table cleared on Adapter -$1 VD Targt -$2 Remote VD -$3 |
||
vdtERASEAborted | 1.3.6.1.4.1.3582.4.1.7.0.8127 |
LD Erase aborted on aborted on Adapter -$1 VD Target -$2 Remote VD -$3 |
||
vdtERASECompleted | 1.3.6.1.4.1.3582.4.1.7.0.8128 |
LD Erase completed on Adapter -$1 VD Target -$2 Remote VD -$3 |
||
vdtERASEFailed | 1.3.6.1.4.1.3582.4.1.7.0.8129 |
LD Erase failed on Adapter -$1 VD Target -$2 Remote VD -$3 |
||
vdtERASEStarted | 1.3.6.1.4.1.3582.4.1.7.0.8130 |
LD Erase started on Adapter -$1 VD Target -$2 Remote VD -$3 |
||
vdtSSCDISASSOCIATEStarted | 1.3.6.1.4.1.3582.4.1.7.0.8131 |
CacheCade(TM) disassociate started on Adapter -$1 VD Target -$2 Remote VD -$3 |
||
vdtSSCDISASSOCIATECompleted | 1.3.6.1.4.1.3582.4.1.7.0.8132 |
CacheCade(TM) disassociate completed on Adapter -$1 VD Target -$2 Remote VD -$3 |
||
vdtSSCDISASSOCIATEFailed | 1.3.6.1.4.1.3582.4.1.7.0.8133 |
CacheCade(TM) disassociate failed on Adapter -$1 VD Target -$2 Remote VD -$3 |
||
vdtSSCDISASSOCIATEAborted | 1.3.6.1.4.1.3582.4.1.7.0.8134 |
CacheCade(TM) disassociate aborted by user on Adapter -$1 VD Target -$2 Remote VD -$3 |
||
vdtACCESSBLOCKEDSSCOFFLINE | 1.3.6.1.4.1.3582.4.1.7.0.8135 |
Access blocked as cached data in CacheCade(TM) is unavailable on Adapter -$1 VD Target -$2 Remote VD -$3 |
||
haLDIsRemote | 1.3.6.1.4.1.3582.4.1.7.0.8136 |
Peer controller now manages LD on Adapter -$1 VD Target -$2 Remote VD -$3 |
||
haLDIsLocal | 1.3.6.1.4.1.3582.4.1.7.0.8137 |
Local controller now manages VD on Adapter -$1 VD Target -$2 Remote VD -$3 |
||
haLDTargetIDConflict | 1.3.6.1.4.1.3582.4.1.7.0.8138 |
Target ID conflict detected. VD on Adapter -$1 VD Target -$2 Remote VD -$3 access is restricted from Peer controller |
||
haLDAccessShared | 1.3.6.1.4.1.3582.4.1.7.0.8139 |
Shared access set for VD on Adapter -$1 VD Target -$2 Remote VD -$3 |
||
haLDAccessExclusive | 1.3.6.1.4.1.3582.4.1.7.0.8140 |
Exclusive access set for VD on Adapter -$1 VD Target -$2 Remote VD -$3 |
||
haLDIncompatible | 1.3.6.1.4.1.3582.4.1.7.0.8141 |
Adapter -$1 VD Target -$2 Remote VD -$3 is incompatible in the HA domain |
||
vdAccessBlockedPeerUnavailable | 1.3.6.1.4.1.3582.4.1.7.0.8142 |
Cached data from peer controller is unavailable. LD on Adapter -$1 VD Target -$2 Remote VD -$3 access policy is set to Blocked |
||
vdNumber | 1.3.6.1.4.1.3582.4.1.7.1101 |
vd Target ID for which Trap is generated. |
||
vdSeq | 1.3.6.1.4.1.3582.4.1.7.1102 |
vd Sequence no for which Trap is generated. |
||
vdProg | 1.3.6.1.4.1.3582.4.1.7.1103 |
progress % |
||
vdCachePolicyChangeReason | 1.3.6.1.4.1.3582.4.1.7.1104 |
VD cache policy. |
||
vdNewState | 1.3.6.1.4.1.3582.4.1.7.1105 |
Virtual Drive state. Values are: offline(0),partially-degraded(1),degraded(2),optimal(3) |
||
vdOldState | 1.3.6.1.4.1.3582.4.1.7.1106 |
Virtual Drive state. Values are: offline(0),partially-degraded(1),degraded(2),optimal(3) |
||
isRemote | 1.3.6.1.4.1.3582.4.1.7.1107 |
HA cluster locale: 0=local, 1=remote (at peer) |
||
vdOldAccessPolicy | 1.3.6.1.4.1.3582.4.1.7.1108 |
Virtual Drive access policy. Values are: read/write(0), read-only(2), blocked(3), transport-ready(14), hidden(15) |
||
vdNewAccessPolicy | 1.3.6.1.4.1.3582.4.1.7.1109 |
Virtual Drive access policy. Values are: read/write(0), read-only(2), blocked(3), transport-ready(14), hidden(15) |
||
vdOldAutoSnapshot | 1.3.6.1.4.1.3582.4.1.7.1110 |
Virtual Drive auto snapshot. Values are: enabled(1), disabled(0) |
||
vdNewAutoSnapshot | 1.3.6.1.4.1.3582.4.1.7.1111 |
Virtual Drive auto snapshot. Values are: enabled(1), disabled(0) |
||
vdOldcacheBypassIOSize | 1.3.6.1.4.1.3582.4.1.7.1112 |
Virtual Drive cache bypass IO size. Values are: 64k(0), 128k(1), 256k(2) |
||
vdNewcacheBypassIOSize | 1.3.6.1.4.1.3582.4.1.7.1113 |
Virtual Drive cache bypass IO size. Values are: 64k(0), 128k(1), 256k(2) |
||
vdOldcacheBypassMode | 1.3.6.1.4.1.3582.4.1.7.1114 |
Virtual Drive cache bypass mode. Values are: intelligent(0), standard(1), custom_mode_1(2), custom_mode_2(3), custom_mode_3(4), reserved_mode_1(5), reserved_mode_2(6), disable(7) |
||
vdNewcacheBypassMode | 1.3.6.1.4.1.3582.4.1.7.1115 |
Virtual Drive cache bypass mode. Values are: intelligent(0), standard(1), custom_mode_1(2), custom_mode_2(3), custom_mode_3(4), reserved_mode_1(5), reserved_mode_2(6), disable(7) |
||
vdOldcurrentCachePolicy | 1.3.6.1.4.1.3582.4.1.7.1116 |
Virtual Drive current cache policy. Values are: write-back(1), write-adaptive(2), read-ahead(4), read-adaptive(8), write-cache-bad-bbu(16), allow-write-cache(32), allow-read-cache(64) |
||
vdNewcurrentCachePolicy | 1.3.6.1.4.1.3582.4.1.7.1117 |
Virtual Drive current cache policy. Values are: write-back(1), write-adaptive(2), read-ahead(4), read-adaptive(8), write-cache-bad-bbu(16), allow-write-cache(32), allow-read-cache(64) |
||
vdOldcurrentPSPolicy | 1.3.6.1.4.1.3582.4.1.7.1118 |
Virtual Drive current powersave policy. Values are: ctrl-default(0), auto(1), max(2), no-cache(4), t10(8), none(254), reserved(255) |
||
vdNewcurrentPSPolicy | 1.3.6.1.4.1.3582.4.1.7.1119 |
Virtual Drive current powersave policy. Values are: ctrl-default(0), auto(1), max(2), no-cache(4), t10(8), none(254), reserved(255) |
||
vdOlddefaultCachePolicy | 1.3.6.1.4.1.3582.4.1.7.1120 |
Virtual Drive default cache policy. Values are: write-back(1), write-adaptive(2), read-ahead(4), read-adaptive(8), write-cache-bad-bbu(16), allow-write-cache(32), allow-read-cache(64) |
||
vdNewdefaultCachePolicy | 1.3.6.1.4.1.3582.4.1.7.1121 |
Virtual Drive default cache policy. Values are: write-back(1), write-adaptive(2), read-ahead(4), read-adaptive(8), write-cache-bad-bbu(16), allow-write-cache(32), allow-read-cache(64) |
||
vdOlddefaultPSPolicy | 1.3.6.1.4.1.3582.4.1.7.1122 |
Virtual Drive default powersave policy. Values are: ctrl-default(0), auto(1), max(2), no-cache(4), t10(8), none(254), reserved(255) |
||
vdNewdefaultPSPolicy | 1.3.6.1.4.1.3582.4.1.7.1123 |
Virtual Drive default powersave policy. Values are: ctrl-default(0), auto(1), max(2), no-cache(4), t10(8), none(254), reserved(255) |
||
vdOlddisableAutoDeleteOldestPIT | 1.3.6.1.4.1.3582.4.1.7.1124 |
Virtual drive disable auto delete oldest pit. Values are: enabled(1), disabled(0) |
||
vdNewdisableAutoDeleteOldestPIT | 1.3.6.1.4.1.3582.4.1.7.1125 |
Virtual Drive disable auto delete oldest pit. Values are: enabled(1), disabled(0) |
||
vdOlddiskCachePolicy | 1.3.6.1.4.1.3582.4.1.7.1126 |
Virtual Drive disk cache policy. Values are: unchanged(0), enabled(1), disabled(2) |
||
vdNewdiskCachePolicy | 1.3.6.1.4.1.3582.4.1.7.1127 |
Virtual Drive disk cache policy. Values are: unchanged(0), enabled(1), disabled(2) |
||
vdOldemulationType | 1.3.6.1.4.1.3582.4.1.7.1128 |
Virtual Drive emulation type. Values are: default(0), disabled(1) |
||
vdNewemulationType | 1.3.6.1.4.1.3582.4.1.7.1129 |
Virtual Drive emulation type. Values are: default(0), disabled(1) |
||
vdOldenabledAtomicityType | 1.3.6.1.4.1.3582.4.1.7.1130 |
Virtual Drive enabled automicity type. Values are: disabled(0), write-all(1), write-t10(2) |
||
vdNewenabledAtomicityType | 1.3.6.1.4.1.3582.4.1.7.1131 |
Virtual Drive enabled automicity type. Values are: disabled(0), write-all(1), write-t10(2) |
||
vdOldexclusiveAccess | 1.3.6.1.4.1.3582.4.1.7.1132 |
Virtual Drive exclusive access. Values are: true(1), false(0) |
||
vdNewexclusiveAccess | 1.3.6.1.4.1.3582.4.1.7.1133 |
Virtual Drive exclusive access. Values are: true(1), false(0) |
||
vdOldforceEmulation | 1.3.6.1.4.1.3582.4.1.7.1134 |
Virtual Drive force emulation. Values are: set(1), not-set(0) |
||
vdNewforceEmulation | 1.3.6.1.4.1.3582.4.1.7.1135 |
Virtual Drive force emulation. Values are: set(1), not-set(0) |
||
vdOldnoBGI | 1.3.6.1.4.1.3582.4.1.7.1138 |
Virtual Drive set no BGI. Values are: 1(disabled), 0 (enabled) |
||
vdNewnoBGI | 1.3.6.1.4.1.3582.4.1.7.1139 |
Virtual Drive set no BGI. Values are: 1(disabled), 0 (enabled) |
||
vdOldscsiUnmapEnabled | 1.3.6.1.4.1.3582.4.1.7.1140 |
Virtual Drive SCSI unmap enabled. Values are: 0(disabled), 1(enabled) |
||
vdNewscsiUnmapEnabled | 1.3.6.1.4.1.3582.4.1.7.1141 |
Virtual Drive SCSI unmap enabled. Values are: 0(disabled), 1(enabled) |
||
vdOldSSCWriteBuferMode | 1.3.6.1.4.1.3582.4.1.7.1142 |
Virtual Drive SSC write buffer mode. Values are: 0(disabled), 1(enabled) |
||
vdNewSSCWriteBuferMode | 1.3.6.1.4.1.3582.4.1.7.1143 |
Virtual Drive SSC write buffer mode. Values are: 0(disabled), 1(enabled) |
||
pdTraps | 1.3.6.1.4.1.3582.4.1.8 | |||
pdtClearAborted | 1.3.6.1.4.1.3582.4.1.8.0.8201 |
Physical Drive Clear aborted on Adapter -$1 Dev -$2 Enc -$3 Slot -$4 |
||
pdtClearFailed | 1.3.6.1.4.1.3582.4.1.8.0.8202 |
Physical Drive Clear failed on Adapter -$1 Dev -$2 Enc -$3 Slot -$4 |
||
pdtClearStarted | 1.3.6.1.4.1.3582.4.1.8.0.8203 |
Physical Drive Clear started on Adapter -$1 Dev -$2 Enc -$3 Slot -$4 |
||
pdtClearCompleted | 1.3.6.1.4.1.3582.4.1.8.0.8204 |
Physical Drive Clear completed on Adapter -$1 Dev -$2 Enc -$3 Slot -$4 |
||
pdtError | 1.3.6.1.4.1.3582.4.1.8.0.8205 |
Error occurred on Adapter -$1 Dev -$2 Enc -$3 Slot -$4 |
||
pdtFormatStart | 1.3.6.1.4.1.3582.4.1.8.0.8206 |
Physical Drive format started on Adapter -$1 Dev -$2 Enc -$3 Slot -$4 |
||
pdtFormatCompleted | 1.3.6.1.4.1.3582.4.1.8.0.8207 |
Physical Drive format completed on Adapter -$1 Dev -$2 Enc -$3 Slot -$4 |
||
pdtInserted | 1.3.6.1.4.1.3582.4.1.8.0.8208 |
PD inserted on Adapter -$1 Dev -$2 Enc -$3 Slot -$4 |
||
pdtRblAborted | 1.3.6.1.4.1.3582.4.1.8.0.8209 |
Rebuild aborted on Adapter -$1 Dev -$2 Enc -$3 Slot -$4 |
||
pdtRblCompleted | 1.3.6.1.4.1.3582.4.1.8.0.8210 |
Rebuild completed on Adapter -$1 Dev -$2 Enc -$3 Slot -$4 |
||
pdtRblFailedBS | 1.3.6.1.4.1.3582.4.1.8.0.8211 |
Rebuild failed(bad source) on Adapter -$1 Dev -$2 Enc -$3 Slot -$4 |
||
pdtRblFailedBT | 1.3.6.1.4.1.3582.4.1.8.0.8212 |
Rebuild failed(bad target) on Adapter -$1 Dev -$2 Enc -$3 Slot -$4 |
||
pdtRblStart | 1.3.6.1.4.1.3582.4.1.8.0.8213 |
Rebuild started on Adapter -$1 Dev -$2 Enc -$3 Slot -$4 |
||
pdtRblResumed | 1.3.6.1.4.1.3582.4.1.8.0.8214 |
Rebuild resumed on Adapter -$1 Dev -$2 Enc -$3 Slot -$4 |
||
pdtRblStartA | 1.3.6.1.4.1.3582.4.1.8.0.8215 |
Rebuild started(auto) on Adapter -$1 Dev -$2 Enc -$3 Slot -$4 |
||
pdtRemoved | 1.3.6.1.4.1.3582.4.1.8.0.8216 |
Physical Drive removed on Adapter -$1 Dev -$2 Enc -$3 Slot -$4 |
||
pdtStateChange | 1.3.6.1.4.1.3582.4.1.8.0.8217 |
PD state changed on Adapter -$1 Dev -$2 Enc -$3 Slot -$4 from $5 to $6 |
||
pdtRedundantPathBroken | 1.3.6.1.4.1.3582.4.1.8.0.8218 |
Redundant Path Broken For Physical Drive on Adapter -$1 Dev -$2 Enc -$3 Slot -$4 EncDevId -$5 pdSAS -$6 |
||
pdtRedundantPathRestored | 1.3.6.1.4.1.3582.4.1.8.0.8219 |
Redundant Path Restored For Physical Drive on Adapter -$1 Dev -$2 Enc -$3 Slot -$4 EncDevId -$5 pdSAS -$6 |
||
pdtRedundantEnclModuleInserted | 1.3.6.1.4.1.3582.4.1.8.0.8220 |
Redundant Encl Modul Inserted on Adapter -$1 Dev -$2 Enc -$3 Slot -$4 EncDevId -$5 pdSAS -$6 pdpath -$7 |
||
pdtRedundantEnclModuleRemoved | 1.3.6.1.4.1.3582.4.1.8.0.8221 |
Redundant Encl Modul Removed on Adapter -$1 Dev -$2 Enc -$3 Slot -$4 EncDevId -$5 pdSAS -$6 pdpath -$7 |
||
pdtFRU | 1.3.6.1.4.1.3582.4.1.8.0.8222 |
FRU changed on Adapter -$1 Dev -$2 Enc -$3 Slot -$4 EncDevId -$5 -FRU $6 |
||
pdtSecured | 1.3.6.1.4.1.3582.4.1.8.0.8223 |
PD security activated on Adapter -$1 Dev -$2 Enc -$3 Slot -$4 |
||
pdtUnsecured | 1.3.6.1.4.1.3582.4.1.8.0.8224 |
PD security disabled on Adapter -$1 Dev -$2 Enc -$3 Slot -$4 |
||
pdtReprovisioned | 1.3.6.1.4.1.3582.4.1.8.0.8225 |
PD is reprovisioned on Adapter -$1 Dev -$2 Enc -$3 Slot -$4 |
||
pdtLockKeyRekeyed | 1.3.6.1.4.1.3582.4.1.8.0.8226 |
PD security key changed on Adapter -$1 Dev -$2 Enc -$3 Slot -$4 |
||
pdtSecurityFailure | 1.3.6.1.4.1.3582.4.1.8.0.8227 |
Security subsystem problems detected on Adapter -$1 Dev -$2 Enc -$3 Slot -$4 |
||
pdtPowerStateChange | 1.3.6.1.4.1.3582.4.1.8.0.8228 |
Power State Change on Adapter -$1 Dev -$2 Enc -$3 Slot -$4 NewPowerState -$5 |
||
pdtNotSupported | 1.3.6.1.4.1.3582.4.1.8.0.8229 |
PD Not Supported on Adapter -$1 Dev -$2 Enc -$3 Slot -$4 |
||
pdtNotCertified | 1.3.6.1.4.1.3582.4.1.8.0.8230 |
PD Not Certified on Adapter -$1 Dev -$2 Enc -$3 Slot -$4 |
||
pdtERASEAborted | 1.3.6.1.4.1.3582.4.1.8.0.8231 |
PD Erase aborted on Adapter -$1 Dev -$2 Enc -$3 Slot -$4 |
||
pdtERASECompleted | 1.3.6.1.4.1.3582.4.1.8.0.8232 |
PD Erase completed on Adapter -$1 Dev -$2 Enc -$3 Slot -$4 |
||
pdtERASEStarted | 1.3.6.1.4.1.3582.4.1.8.0.8233 |
PD Erase started on Adapter -$1 Dev -$2 Enc -$3 Slot -$4 |
||
pdtERASEFailed | 1.3.6.1.4.1.3582.4.1.8.0.8234 |
PD Erase Failed on Adapter -$1 Dev -$2 Enc -$3 Slot -$4 |
||
haPDIsRemote | 1.3.6.1.4.1.3582.4.1.8.0.8235 |
Peer controller now manages PD on Adapter -$1 Dev -$2 Enc -$3 Slot -$4 |
||
haPDIsLocal | 1.3.6.1.4.1.3582.4.1.8.0.8236 |
Local controller now manages PD on Adapter -$1 Dev -$2 Enc -$3 Slot -$4 |
||
pdID | 1.3.6.1.4.1.3582.4.1.8.1201 |
Device ID for which Trap is generated. |
||
pdEncIndex | 1.3.6.1.4.1.3582.4.1.8.1202 |
Enclosure index(0 means not within an enclosure) for which Trap is generated. |
||
pdSlotNo | 1.3.6.1.4.1.3582.4.1.8.1203 |
Slot no for the enclosure |
||
pdNewState | 1.3.6.1.4.1.3582.4.1.8.1204 |
Physical Drive state. Values are: unconfigured-good(0),unconfigured-bad(1),hot-spare(2),offline(16),failed(17),rebuild(20),online(24),copyback(32),system(64) |
||
pdOldState | 1.3.6.1.4.1.3582.4.1.8.1205 |
Physical Drive state. Values are: unconfigured-good(0),unconfigured-bad(1),hot-spare(2),offline(16),failed(17),rebuild(20),online(24),copyback(32),system(64) |
||
pdEnclDeviceId | 1.3.6.1.4.1.3582.4.1.8.1206 |
Enclosure Device ID for which Trap is generated. |
||
pdSASAdd | 1.3.6.1.4.1.3582.4.1.8.1207 |
Device SAS addresses. Comma separeted for multiple address. |
||
pdPath | 1.3.6.1.4.1.3582.4.1.8.1208 |
PD path. |
||
pdFRU | 1.3.6.1.4.1.3582.4.1.8.1209 |
PD FRU for which trap is generated. |
||
pdNewPowerState | 1.3.6.1.4.1.3582.4.1.8.1210 |
New Power Status Of the Device.Values are device is active(0),device is stopped(1),device is transitioning between power states(255) |
||
enclTraps | 1.3.6.1.4.1.3582.4.1.9 | |||
widePortLinkLost | 1.3.6.1.4.1.3582.4.1.9.0.8330 |
Link lost on SAS wide port on Adapter -$1 port -$2 PHY -$3 |
||
widePortLinkRestored | 1.3.6.1.4.1.3582.4.1.9.0.8331 |
Link Restored on SAS wide port on Adapter -$1 port -$2 PHY -$3 |
||
atPort | 1.3.6.1.4.1.3582.4.1.9.1301 |
Prot no. |
||
onPHY | 1.3.6.1.4.1.3582.4.1.9.1302 |
PHY no |
||
pciTraps | 1.3.6.1.4.1.3582.4.1.10 | |||
haHwIncompatible | 1.3.6.1.4.1.3582.4.1.10.0.8501 |
Peer Controller hardware is incompatible |
||
pciVendorId | 1.3.6.1.4.1.3582.4.1.10.1501 |
PCI VendorID |
||
pciDeviceId | 1.3.6.1.4.1.3582.4.1.10.1502 |
PCI Device ID |
||
pciSubVendorId | 1.3.6.1.4.1.3582.4.1.10.1503 |
PCI SubVendorID |
||
pciSubDeviceId | 1.3.6.1.4.1.3582.4.1.10.1504 |
PCI SubDeviceID |
||
copyrightInfo | 1.3.6.1.4.1.3582.4.1.11 | |||
copyright | 1.3.6.1.4.1.3582.4.1.11.1 |
LSI Corporation |